Engine parameters
The Cadillac CT4 has 365 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
1-2 shift error CADILLAC_1_2_SHIFT_ERROR
- Request
22 19 97 - Service 22
DID 1997 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
1-2 shift error CADILLAC_1_2_SHIFT_ERROR_V2
- Request
22 19 97 - Service 22
DID 1997 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
1-2 shift time CADILLAC_1_2_SHIFT_TIME
- Request
22 19 93 - Service 22
DID 1993 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
1-2 shift time CADILLAC_1_2_SHIFT_TIME_V2
- Request
22 19 93 - Service 22
DID 1993 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
2-3 shift error CADILLAC_2_3_SHIFT_ERROR
- Request
22 19 98 - Service 22
DID 1998 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
2-3 shift error CADILLAC_2_3_SHIFT_ERROR_V2
- Request
22 19 98 - Service 22
DID 1998 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
2-3 shift time CADILLAC_2_3_SHIFT_TIME
- Request
22 19 94 - Service 22
DID 1994 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
2-3 shift time CADILLAC_2_3_SHIFT_TIME_V2
- Request
22 19 94 - Service 22
DID 1994 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
3-4 shift error CADILLAC_3_4_SHIFT_ERROR
- Request
22 19 99 - Service 22
DID 1999 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
3-4 shift error CADILLAC_3_4_SHIFT_ERROR_V2
- Request
22 19 99 - Service 22
DID 1999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
3-4 shift time CADILLAC_3_4_SHIFT_TIME
- Request
22 19 95 - Service 22
DID 1995 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
3-4 shift time CADILLAC_3_4_SHIFT_TIME_V2
- Request
22 19 95 - Service 22
DID 1995 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
14V auxiliary power module enable command CADILLAC_14V_APM_ENABLE
- Request
22 1C 39 - Service 22
DID 1C39 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 128)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2020 to 2026.
14V power available CADILLAC_14V_POWER_AVAILABLE
- Request
22 41 B0 - Service 22
DID 41B0 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 W
- Unit
- W
In testing for 2020 to 2026.
14V power module set point CADILLAC_14V_POWER_MODULE
- Request
22 1C 38 - Service 22
DID 1C38 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
14V power module set point voltage CADILLAC_14V_POWER_MODULE_V
- Request
22 1C 47 - Service 22
DID 1C47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2020 to 2026.
A/C low side pressure CADILLAC_AC_LOW_SIDE
- Request
22 15 63 - Service 22
DID 1563 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Active grille cold temperature mode CADILLAC_ACTIVE_GRILLE_COLD_T
- Request
22 23 9B - Service 22
DID 239B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Active grille shutter position CADILLAC_ACTIVE_GRILLE_SHUTTER_POS
- Request
22 23 66 - Service 22
DID 2366 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Active grille shutter position command CADILLAC_ACTIVE_GRILLE
- Request
22 23 64 - Service 22
DID 2364 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Air conditioning high side pressure CADILLAC_AC_HIGH_SIDE_P
- Request
22 15 64 - Service 22
DID 1564 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2.02)- Range
- 0 to 515.1 psi
- Unit
- psi
In testing for 2020 to 2026.
Air conditioning high side pressure CADILLAC_AC_HIGH_SIDE_P_V2
- Request
22 15 64 - Service 22
DID 1564 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2.02)- Range
- 0 to 515.1 psi
- Unit
- psi
In testing for 2020 to 2026.
Air filter life remaining CADILLAC_AIRFILT_LIFEConfirmed
- Request
22 36 A7 - Service 22
DID 36A7 - Module
DA11 → 2AF111 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2020 to 2022, 2024 to 2026.
Air filter life remaining CADILLAC_AIRFILT_LIFE_V2
- Request
22 36 A7 - Service 22
DID 36A7 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2023. Supported for 2021.
Air temperature filtered CADILLAC_AIR_TEMP_FILTERED
- Request
22 80 1F - Service 22
DID 801F - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Air temperature unfiltered CADILLAC_AIR_TEMP_UNFILTERED
- Request
22 80 1E - Service 22
DID 801E - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Air/fuel ratio, commanded CADILLAC_AIR_FUEL_RAT_CMD
- Request
22 11 9E - Service 22
DID 119E - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5
- Unit
- Number
In testing for 2020 to 2026.
Air/fuel ratio, commanded CADILLAC_AIR_FUEL_RAT_CMD_V2
- Request
22 11 9E - Service 22
DID 119E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5
- Unit
- Number
In testing for 2020 to 2026.
Ambient air temperature 2 CADILLAC_AIR_TEMP_AMBIENT_2
- Request
22 23 2C - Service 22
DID 232C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
ATF temperature CADILLAC_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 19 40 - Service 22
DID 1940 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Axle torque driver requested CADILLAC_AXLE_TQ_DRIVER_REQ
- Request
22 24 34 - Service 22
DID 2434 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 22534)- Range
- -22534 to 43001 N·m
- Unit
- N·m
In testing for 2020 to 2026.
Axle torque driver requested CADILLAC_AXLE_TQ_DRIVER_REQ_V2
- Request
22 24 34 - Service 22
DID 2434 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 22534)- Range
- -22534 to 43001 N·m
- Unit
- N·m
In testing for 2020 to 2026.
Axle torque driver requested CADILLAC_AXLE_TQ_DRIVER_REQ_V3
- Request
22 24 34 - Service 22
DID 2434 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 22534)- Range
- -22534 to 43001 N·m
- Unit
- N·m
In testing for 2020 to 2026.
Balance rate, cylinder 1 CADILLAC_BALANCE_RATE_CYL_1
- Request
22 16 2F - Service 22
DID 162F - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 1 CADILLAC_BALANCE_RATE_CYL_1_V2
- Request
22 16 2F - Service 22
DID 162F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 2 CADILLAC_BALANCE_RATE_CYL_2
- Request
22 16 30 - Service 22
DID 1630 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 2 CADILLAC_BALANCE_RATE_CYL_2_V2
- Request
22 16 30 - Service 22
DID 1630 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 3 CADILLAC_BALANCE_RATE_CYL_3
- Request
22 16 31 - Service 22
DID 1631 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 3 CADILLAC_BALANCE_RATE_CYL_3_V2
- Request
22 16 31 - Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 4 CADILLAC_BALANCE_RATE_CYL_4
- Request
22 16 32 - Service 22
DID 1632 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 4 CADILLAC_BALANCE_RATE_CYL_4_V2
- Request
22 16 32 - Service 22
DID 1632 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 5 CADILLAC_BALANCE_RATE_CYL_5
- Request
22 16 33 - Service 22
DID 1633 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 5 CADILLAC_BALANCE_RATE_CYL_5_V2
- Request
22 16 33 - Service 22
DID 1633 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 6 CADILLAC_BALANCE_RATE_CYL_6
- Request
22 16 34 - Service 22
DID 1634 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 6 CADILLAC_BALANCE_RATE_CYL_6_V2
- Request
22 16 34 - Service 22
DID 1634 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 7 CADILLAC_BALANCE_RATE_CYL_7
- Request
22 16 35 - Service 22
DID 1635 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 7 CADILLAC_BALANCE_RATE_CYL_7_V2
- Request
22 16 35 - Service 22
DID 1635 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 8 CADILLAC_BALANCE_RATE_CYL_8
- Request
22 16 36 - Service 22
DID 1636 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Balance rate, cylinder 8 CADILLAC_BALANCE_RATE_CYL_8_V2
- Request
22 16 36 - Service 22
DID 1636 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 2020 to 2026.
Barometric pressure CADILLAC_BAROMETRIC_P_V8
- Request
22 11 9D - Service 22
DID 119D - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Barometric pressure, alternate CADILLAC_BAROMETRIC_P_V6
- Request
22 12 51 - Service 22
DID 1251 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Barometric pressure, V6 CADILLAC_BAROMETRIC_P_V6_V2
- Request
22 12 51 - Service 22
DID 1251 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Barometric pressure, V8 CADILLAC_BAROMETRIC_P_V8_V2
- Request
22 11 9D - Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Battery 5V reference voltage CADILLAC_BAT_5V_REFERENCE_V_1
- Request
22 40 D3 - Service 22
DID 40D3 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 13107 + 5)- Range
- 0 to 7.49 V
- Unit
- V
In testing for 2020 to 2026.
Battery cell average voltage CADILLAC_BAT_CELL_AVG_V
- Request
22 C2 18 - Service 22
DID C218 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2026.
Battery cell average voltage 2 CADILLAC_BAT_CELL_AVG_V_2
- Request
22 44 B9 - Service 22
DID 44B9 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8000)- Range
- 0 to 8.19 V
- Unit
- V
In testing for 2020 to 2026.
Battery cell maximum voltage CADILLAC_BAT_CELL_MAX_V
- Request
22 43 2B - Service 22
DID 432B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 3 ÷ 5000)- Range
- 0 to 39.32 V
- Unit
- V
In testing for 2020 to 2026.
Battery cell minimum voltage CADILLAC_BAT_CELL_MIN_V
- Request
22 43 29 - Service 22
DID 4329 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 3 ÷ 5000)- Range
- 0 to 39.32 V
- Unit
- V
In testing for 2020 to 2026.
Battery coolant pump speed CADILLAC_BAT_CLT_PMP_SPD
- Request
22 43 5A - Service 22
DID 435A - Module
7E4 → 7EC - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2020 to 2026.
Battery coolant pump, commanded CADILLAC_BAT_CLT_PMP_CMD
- Request
22 43 59 - Service 22
DID 4359 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery coolant temperature CADILLAC_BAT_CLT_TEMP
- Request
22 41 A4 - Service 22
DID 41A4 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery heater power, commanded CADILLAC_BAT_HEATER_COMMAND_W
- Request
22 41 B5 - Service 22
DID 41B5 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
In testing for 2020 to 2026.
Battery heater power, measured CADILLAC_BAT_HEATER_MEAS_W
- Request
22 41 B6 - Service 22
DID 41B6 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
In testing for 2020 to 2026.
Battery heater, commanded CADILLAC_BAT_HEATER_COMMAND
- Request
22 43 9E - Service 22
DID 439E - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery pack capacity, raw CADILLAC_BAT_PACK_CAP_AH_RAW_2017_2018
- Request
22 41 A3 - Service 22
DID 41A3 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 Ah
- Unit
- Ah
In testing for 2020 to 2026.
Battery pack capacity, raw CADILLAC_BAT_PACK_CAP_AH_RAW_2019
- Request
22 45 F9 - Service 22
DID 45F9 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 Ah
- Unit
- Ah
In testing for 2020 to 2026.
Battery pack coolant level switch CADILLAC_BAT_PACK_CLT_LEVEL
- Request
22 44 2C - Service 22
DID 442C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2026.
Battery pack coolest module CADILLAC_BAT_PACK_TEMP_MIN_MODULE
- Request
22 43 4C - Service 22
DID 434C - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Battery pack current HD CADILLAC_BAT_PACK_CURRENT_HD
- Request
22 40 D4 - Service 22
DID 40D4 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638 to 1638 A
- Unit
- A
In testing for 2020 to 2026.
Battery pack hottest module CADILLAC_BAT_PACK_TEMP_MAX_MODULE
- Request
22 43 4B - Service 22
DID 434B - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Battery pack maximum temperature CADILLAC_BAT_PACK_TEMP_MAX
- Request
22 43 49 - Service 22
DID 4349 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack maximum temperature, alternate CADILLAC_BAT_PACK_TEMP_MAX_ALT
- Request
22 24 16 - Service 22
DID 2416 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack maximum voltage CADILLAC_BAT_PACK_MAX_V
- Request
22 43 3C - Service 22
DID 433C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13 ÷ 25)- Range
- 0 to 34078 V
- Unit
- V
In testing for 2020 to 2026.
Battery pack minimum state of charge limit CADILLAC_BAT_PACK_MIN_ST_CHG
- Request
22 43 3F - Service 22
DID 433F - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery pack minimum temperature CADILLAC_BAT_PACK_TEMP_MIN
- Request
22 43 4A - Service 22
DID 434A - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack minimum temperature, alternate CADILLAC_BAT_PACK_TEMP_MIN_ALT
- Request
22 24 17 - Service 22
DID 2417 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack minimum voltage CADILLAC_BAT_PACK_MIN_V
- Request
22 43 3B - Service 22
DID 433B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13 ÷ 25)- Range
- 0 to 34078 V
- Unit
- V
In testing for 2020 to 2026.
Battery pack resistance CADILLAC_BAT_PACK_RES
- Request
22 40 E9 - Service 22
DID 40E9 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 Ω
- Unit
- Ω
In testing for 2020 to 2026.
Battery pack state of charge raw LD 2 CADILLAC_BAT_PACK_ST_CHG_RAW_2
- Request
22 24 11 - Service 22
DID 2411 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery pack state of charge raw LD 3 CADILLAC_BAT_PACK_ST_CHG_RAW_3
- Request
22 43 2F - Service 22
DID 432F - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery pack state of charge variation CADILLAC_BAT_PACK_ST_CHG
- Request
22 43 5F - Service 22
DID 435F - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Battery pack temperature 1 CADILLAC_BAT_PACK_TEMP_1
- Request
22 40 D7 - Service 22
DID 40D7 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack temperature 2 CADILLAC_BAT_PACK_TEMP_2
- Request
22 40 D9 - Service 22
DID 40D9 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack temperature 3 CADILLAC_BAT_PACK_TEMP_3
- Request
22 40 DB - Service 22
DID 40DB - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack temperature 4 CADILLAC_BAT_PACK_TEMP_4
- Request
22 40 DD - Service 22
DID 40DD - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack temperature 5 CADILLAC_BAT_PACK_TEMP_5
- Request
22 40 DF - Service 22
DID 40DF - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack temperature 6 CADILLAC_BAT_PACK_TEMP_6
- Request
22 40 E1 - Service 22
DID 40E1 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Battery pack terminal voltage LD CADILLAC_BAT_PACK_TERMINAL_V
- Request
22 82 A3 - Service 22
DID 82A3 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 2020 to 2026.
Battery pack voltage LD CADILLAC_BAT_PACK_V_LD
- Request
22 43 2D - Service 22
DID 432D - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13 ÷ 25)- Range
- 0 to 34078 V
- Unit
- V
In testing for 2020 to 2026.
Battery thermal conditioning inactive time CADILLAC_BAT_THERMAL
- Request
22 24 AC - Service 22
DID 24AC - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070 s
- Unit
- s
In testing for 2020 to 2026.
Battery thermal conditioning inactive time CADILLAC_BAT_THERMAL_V2
- Request
22 24 AC - Service 22
DID 24AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070 s
- Unit
- s
In testing for 2020 to 2026.
Boost pressure, actual CADILLAC_BP_ACT
- Request
22 20 E3 - Service 22
DID 20E3 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 2020 to 2022, 2024 to 2026. Not supported for 2023.
Boost pressure, desired CADILLAC_BP_DES
- Request
22 32 8A - Service 22
DID 328A - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Boost pressure: actual CADILLAC_BP_ACT_V2
- Request
22 20 E3 - Service 22
DID 20E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Boost pressure: desired CADILLAC_BP_DES_V2
- Request
22 32 8A - Service 22
DID 328A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Brake pressure CADILLAC_BPConfirmed
- Request
22 4A 7C - Service 22
DID 4A7C - Module
DA28 → 2AF128 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 100 − 1000)- Range
- -13800 to 11700 kPa
- Unit
- kPa
Confirmed for 2023. In testing for 2020 to 2022, 2024 to 2026.
Cabin A/C compressor command CADILLAC_CABIN_AC_COMP
- Request
22 45 1F - Service 22
DID 451F - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 1)- Range
- -1 to 254
- Unit
- Number
In testing for 2020 to 2026.
Cabin A/C compressor power consumption CADILLAC_CABIN_AC_COMP_POWER
- Request
22 82 B7 - Service 22
DID 82B7 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
In testing for 2020 to 2026.
Cabin A/C compressor speed CADILLAC_CABIN_AC_COMP_SPD
- Request
22 82 B5 - Service 22
DID 82B5 - Module
7E4 → 7EC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2020 to 2026.
Cabin A/C compressor speed commanded CADILLAC_CABIN_AC_COMP_SPD_CMD
- Request
22 82 B4 - Service 22
DID 82B4 - Module
7E4 → 7EC - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2020 to 2026.
Cabin A/C high side sensor pressure CADILLAC_CABIN_AC_HIGH_SIDE_P
- Request
22 15 64 - Service 22
DID 1564 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Cabin A/C high side sensor voltage CADILLAC_CABIN_AC_HIGH_SIDE_V
- Request
22 11 44 - Service 22
DID 1144 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2020 to 2026.
Cabin A/C low side sensor pressure CADILLAC_CABIN_AC_LOW_SIDE_P
- Request
22 82 B2 - Service 22
DID 82B2 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 13647 ÷ 5000)- Range
- 0 to 695 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Cabin A/C low side sensor voltage CADILLAC_CABIN_AC_LOW_SIDE_V
- Request
22 82 B3 - Service 22
DID 82B3 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2020 to 2026.
Cabin A/C power, commanded CADILLAC_CABIN_AC_COMMAND_W
- Request
22 41 B1 - Service 22
DID 41B1 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
In testing for 2020 to 2026.
Cabin A/C power, measured CADILLAC_CABIN_AC_MEAS_W
- Request
22 41 B2 - Service 22
DID 41B2 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
In testing for 2020 to 2026.
Cabin blower motor speed request CADILLAC_CABIN_BLOWER_MOTOR
- Request
22 45 1E - Service 22
DID 451E - Module
7E4 → 7EC - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Cabin heater coolant control solenoid valve command CADILLAC_CABIN_HEATER_CLT
- Request
22 43 B0 - Service 22
DID 43B0 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Cabin heater power, commanded CADILLAC_CABIN_HEATER_COMMAND_W
- Request
22 41 B3 - Service 22
DID 41B3 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 W
- Unit
- W
In testing for 2020 to 2026.
Cabin heater power, measured CADILLAC_CABIN_HEATER_MEAS_W
- Request
22 41 B4 - Service 22
DID 41B4 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 W
- Unit
- W
In testing for 2020 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. Supported for 2021.
Calculated engine oil pressure CADILLAC_EOP_CALC
- Request
22 1C 1B - Service 22
DID 1C1B - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Calculated engine oil pressure CADILLAC_EOP_CALC_V2
- Request
22 1C 1B - Service 22
DID 1C1B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Calculated engine oil temperature CADILLAC_EOT_CALC
Pelican can show this parameter as the engine oil temperature.
- Request
22 11 54 - Service 22
DID 1154 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Calculated engine oil temperature CADILLAC_EOT_CALC_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 11 54 - Service 22
DID 1154 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Charger AC control pilot CADILLAC_CHARGER_AC_CTRL
- Request
22 45 46 - Service 22
DID 4546 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Charger AC control pilot voltage CADILLAC_CHARGER_AC_CTRL_V
- Request
22 45 45 - Service 22
DID 4545 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 V
- Unit
- V
In testing for 2020 to 2026.
Charger AC current requested CADILLAC_CHARGER_AC_CURRENT
- Request
22 45 33 - Service 22
DID 4533 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 10)- Range
- 0 to 76.5 A
- Unit
- A
In testing for 2020 to 2026.
Charger AC input status duty cycle CADILLAC_CHARGER_AC_INPUT
- Request
22 45 2D - Service 22
DID 452D - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Charger DC output status duty cycle CADILLAC_CHARGER_DC_OUTPUT
- Request
22 45 2E - Service 22
DID 452E - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Charger DC port current CADILLAC_CHARGER_DC_PORT_CURRENT
- Request
22 44 24 - Service 22
DID 4424 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128 − 256)- Range
- -256 to 255 A
- Unit
- A
In testing for 2020 to 2026.
Charger DC port current requested CADILLAC_CHARGER_DC_PORT_CURRENT_REQ
- Request
22 44 45 - Service 22
DID 4445 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128 − 256)- Range
- -256 to 255 A
- Unit
- A
In testing for 2020 to 2026.
Charger DC port negative isolation CADILLAC_CHARGER_DC_PORT_NEGATIVE
- Request
22 44 23 - Service 22
DID 4423 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 2020 to 2026.
Charger DC port positive isolation CADILLAC_CHARGER_DC_PORT
- Request
22 44 23 - Service 22
DID 4423 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 2020 to 2026.
Charger DC port temperature CADILLAC_CHARGER_DC_PORT_T
- Request
22 44 25 - Service 22
DID 4425 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Charger last charge AC energy CADILLAC_CHARGER_LAST_CHG_AC_2017_2018
- Request
22 43 7D - Service 22
DID 437D - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 kWh
- Unit
- kWh
In testing for 2020 to 2026.
Charger last charge HV energy output CADILLAC_CHARGER_LAST_CHG_HV
- Request
22 43 7F - Service 22
DID 437F - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 kWh
- Unit
- kWh
In testing for 2020 to 2026.
Charger port lock actuator position signal CADILLAC_CHARGER_PORT_LOCK
- Request
22 44 5D - Service 22
DID 445D - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2026.
Charger power input available CADILLAC_CHARGER_BAT_CHARGER
- Request
22 43 76 - Service 22
DID 4376 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
In testing for 2020 to 2026.
Charger power output available CADILLAC_CHARGER_POWER_OUTPUT
- Request
22 43 75 - Service 22
DID 4375 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
In testing for 2020 to 2026.
Charger proximity detection circuit voltage CADILLAC_CHARGER_PROXIMITY_V
- Request
22 43 BB - Service 22
DID 43BB - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2026.
Charger system efficiency, active test CADILLAC_CHARGER_SYSTEM_EFFICIENCY_ACTIVE
- Request
22 45 65 - Service 22
DID 4565 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25 ÷ 32)- Range
- 0 to 199 %
- Unit
- %
In testing for 2020 to 2026.
Charger system efficiency, active test status CADILLAC_CHARGER_SYSTEM_EFFICIENCY
- Request
22 45 64 - Service 22
DID 4564 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Charger system efficiency, passive test CADILLAC_CHARGER_SYSTEM_EFFICIENCY_PASSIVE
- Request
22 45 66 - Service 22
DID 4566 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 40 ÷ 51)- Range
- 0 to 200 %
- Unit
- %
In testing for 2020 to 2026.
Charger system HV interlock circuit CADILLAC_CHARGER_SYSTEM_HV_INTERLOCK
- Request
22 45 58 - Service 22
DID 4558 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Charger system HV interlock circuit status CADILLAC_CHARGER_SYSTEM_HV
- Request
22 45 59 - Service 22
DID 4559 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Charger system inactive time CADILLAC_CHARGER_SYSTEM
- Request
22 24 AB - Service 22
DID 24AB - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070 s
- Unit
- s
In testing for 2020 to 2026.
Charger total power output available CADILLAC_CHARGER_TOT_POWER
- Request
22 41 AF - Service 22
DID 41AF - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
In testing for 2020 to 2026.
Charging limit ? CADILLAC_CHG_LIM
- Request
22 41 B7 - Service 22
DID 41B7 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 W
- Unit
- W
In testing for 2020 to 2026.
Clock day of week CADILLAC_CLOCK_DOW
- Request
22 44 16 - Service 22
DID 4416 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2023. Supported for 2021.
Contactor commands CADILLAC_CONTACTOR_COMMANDS
- Request
22 43 0E - Service 22
DID 430E - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Contactor open reason history 1 CADILLAC_CONTACTOR_OPEN_1
- Request
22 24 8C - Service 22
DID 248C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Contactor open reason history 2 CADILLAC_CONTACTOR_OPEN_2
- Request
22 24 8D - Service 22
DID 248D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Contactor open reason history 3 CADILLAC_CONTACTOR_OPEN_3
- Request
22 24 8E - Service 22
DID 248E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Contactor open reason history 4 CADILLAC_CONTACTOR_OPEN_4
- Request
22 24 8F - Service 22
DID 248F - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Contactor open reason history 5 CADILLAC_CONTACTOR_OPEN_5
- Request
22 24 90 - Service 22
DID 2490 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Contactor open reason history 6 CADILLAC_CONTACTOR_OPEN_6
- Request
22 24 91 - Service 22
DID 2491 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Contactor open reason history 7 CADILLAC_CONTACTOR_OPEN_7
- Request
22 24 92 - Service 22
DID 2492 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Contactor open reason history 8 CADILLAC_CONTACTOR_OPEN_8
- Request
22 24 93 - Service 22
DID 2493 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Cooling fan command CADILLAC_COOLING_FAN_CMD
- Request
22 38 12 - Service 22
DID 3812 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Cooling fan command CADILLAC_COOLING_FAN_CMD_V2
- Request
22 38 12 - Service 22
DID 3812 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Cooling fan motor command CADILLAC_COOLING_FAN_MOTOR_CMD
- Request
22 13 AF - Service 22
DID 13AF - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Cooling fan motor command CADILLAC_COOLING_FAN_MOTOR_CMD_V2
- Request
22 13 AF - Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Cooling fan, radiator motor, commanded CADILLAC_COOLING_FAN_RADIATOR_CMD
- Request
22 13 AF - Service 22
DID 13AF - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Cruise control status CADILLAC_CRUISE_CTRL_STAT
- Request
22 20 67 - Service 22
DID 2067 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Diesel particulate filter, average filter inlet temperature during regeneration CADILLAC_DPF_AVG_FLT_INLET_T_DURING_REGEN
- Request
22 20 F8 - Service 22
DID 20F8 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 s
- Unit
- s
In testing for 2020 to 2026.
Diesel particulate filter, average regeneration duration CADILLAC_DPF_AVG_REGEN_DURATION
- Request
22 20 F9 - Service 22
DID 20F9 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2040 ÷ 65535)- Range
- 0 to 2040 s
- Unit
- s
In testing for 2020 to 2026.
Diesel particulate filter, calculated flow resistance [kpa/(l/s)] CADILLAC_DPF_CALCULATED_FLOW_RESISTANCE_KPA_L_S
- Request
22 20 F5 - Service 22
DID 20F5 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 100)- Range
- 0 to 2.55
- Unit
- Number
In testing for 2020 to 2026.
Diesel particulate filter, corrected pressure CADILLAC_DPF_CORRECTED_PRES
- Request
22 34 D9 - Service 22
DID 34D9 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100 ÷ 10000)- Range
- -327.68 to 327.67 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Diesel particulate filter, engine run time since last regeneration CADILLAC_DPF_ENGINE_RUN_TIME_SINCE_LAST_REGEN_MIN
- Request
22 20 F3 - Service 22
DID 20F3 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8 ÷ 60)- Range
- 0 to 8738 min
- Unit
- min
In testing for 2020 to 2026.
Diesel particulate filter, exhaust gas temperature 1 CADILLAC_DPF_EGT_1
- Request
22 30 3A - Service 22
DID 303A - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Diesel particulate filter, exhaust gas temperature 2 CADILLAC_DPF_EGT_2
- Request
22 30 3B - Service 22
DID 303B - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Diesel particulate filter, exhaust gas temperature 3 CADILLAC_DPF_EGT_3
- Request
22 30 A9 - Service 22
DID 30A9 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Diesel particulate filter, exhaust gas temperature 4 CADILLAC_DPF_EGT_4
- Request
22 00 78 - Service 22
DID 0078 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Diesel particulate filter, exhaust gas temperature 5 CADILLAC_DPF_EGT_5
- Request
22 30 AB - Service 22
DID 30AB - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Diesel particulate filter, number of completed regenerations CADILLAC_DPF_NUMBER_OF_COMPLETED_REGENS
- Request
22 30 4B - Service 22
DID 304B - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Diesel particulate filter, pressure CADILLAC_DPF_PRES
- Request
22 34 D8 - Service 22
DID 34D8 - Module
DA11 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100 ÷ 10000)- Range
- -327.68 to 327.67 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Diesel particulate filter, pressure sensor CADILLAC_DPF_PRES_SNS
- Request
22 30 35 - Service 22
DID 3035 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Diesel particulate filter, regeneration reason CADILLAC_DPF_REGEN_REASON
- Request
22 30 3E - Service 22
DID 303E - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Diesel particulate filter, regeneration status CADILLAC_DPF_REGEN_STS
- Request
22 33 75 - Service 22
DID 3375 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Electronics coolant pump speed CADILLAC_ELECTRONICS_CLT_PMP
- Request
22 43 58 - Service 22
DID 4358 - Module
7E4 → 7EC - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 2020 to 2026.
Electronics coolant pump, commanded CADILLAC_ELECTRONICS_CLT_PMP_CMD
- Request
22 43 57 - Service 22
DID 4357 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Electronics coolant temperature CADILLAC_ELECTRONICS_CLT_TEMP
- Request
22 1C 43 - Service 22
DID 1C43 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023. Supported for 2021.
Engine oil absolute pressure CADILLAC_EOP_ABS
- Request
22 23 44 - Service 22
DID 2344 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Engine oil absolute pressure CADILLAC_EOP_ABS_2
- Request
22 23 44 - Service 22
DID 2344 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Engine oil life remaining CADILLAC_EO_LIFE_REMAINING
- Request
22 4D C0 - Service 22
DID 4DC0 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Engine oil life remaining CADILLAC_EO_LIFE_REMAINING_V2
- Request
22 4D C0 - Service 22
DID 4DC0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Engine oil pressure CADILLAC_EOP
- Request
22 14 70 - Service 22
DID 1470 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Engine oil pressure CADILLAC_EOP_ACTConfirmed
- Request
22 23 45 - Service 22
DID 2345 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 kPa
- Unit
- kPa
Confirmed for 2023. In testing for 2020 to 2022, 2024 to 2026.
Engine oil pressure CADILLAC_EOP_DA11
- Request
22 14 70 - Service 22
DID 1470 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Engine oil pressure CADILLAC_EOP_V2
- Request
22 23 45 - Service 22
DID 2345 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Engine oil pressure 2 CADILLAC_EOP_2
Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.
- Request
22 11 5C - Service 22
DID 115C - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 5 − 21.6)- Range
- -21.6 to 131.39 psi
- Unit
- psi
In testing for 2020 to 2026.
Engine oil pressure 2 CADILLAC_EOP_2_V2
Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.
- Request
22 11 5C - Service 22
DID 115C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 5 − 21.6)- Range
- -21.6 to 131.39 psi
- Unit
- psi
In testing for 2020 to 2026.
Engine oil pressure control solenoid valve command CADILLAC_EOP_CTRL_SOLENOID_VALVE_CMD
- Request
22 33 18 - Service 22
DID 3318 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020 to 2026.
Engine oil pressure control solenoid valve command CADILLAC_EOP_CTRL_SOLENOID_VALVE_CMD_V2
- Request
22 33 18 - Service 22
DID 3318 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020 to 2026.
Engine oil pressure, actual CADILLAC_EOP_ACT_V2
- Request
22 23 45 - Service 22
DID 2345 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Engine oil pressure, desired CADILLAC_EOP_DES
- Request
22 37 A7 - Service 22
DID 37A7 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Engine oil temperature CADILLAC_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 00 5C - Service 22
DID 005C - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023. In testing for 2020 to 2022, 2024 to 2026.
Engine oil temperature CADILLAC_EOT_2
- Request
22 15 3E - Service 22
DID 153E - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- 0 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Engine oil temperature CADILLAC_EOT_ALT
Pelican can show this parameter as the engine oil temperature.
- Request
22 15 3E - Service 22
DID 153E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- 0 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Engine oil temperature CADILLAC_EOT_DA11
- Request
22 15 3E - Service 22
DID 153E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- 0 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Engine oil temperature CADILLAC_EOT_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 15 3E - Service 22
DID 153E - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- 0 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Engine oil temperature CADILLAC_EOT_V3
Pelican can show this parameter as the engine oil temperature.
- Request
22 00 5C - Service 22
DID 005C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Engine oil temperature 2 CADILLAC_EOT_2_V2
- Request
22 15 3E - Service 22
DID 153E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Engine torque CADILLAC_ENG_TQ
- Request
22 19 DE - Service 22
DID 19DE - Module
DA11 → 2AF111 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2020 to 2026.
Engine torque CADILLAC_ENG_TQ_2
- Request
22 20 3F - Service 22
DID 203F - Module
DA11 → 2AF111 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 N·m
- Unit
- N·m
In testing for 2020 to 2026.
Engine torque CADILLAC_ENG_TQ_7E0
- Request
22 20 3F - Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 N·m
- Unit
- N·m
In testing for 2020 to 2026.
Engine torque CADILLAC_ENG_TQ_V2
- Request
22 19 DE - Service 22
DID 19DE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2020 to 2026.
EV trip this drive cycle CADILLAC_EV_TRIP_THIS_DRIVE
- Request
22 24 87 - Service 22
DID 2487 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 km
- Unit
- km
In testing for 2020 to 2026.
Evaporative emissions purge CADILLAC_EVAPORATIVE
- Request
22 11 70 - Service 22
DID 1170 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Evaporative emissions purge CADILLAC_EVAPORATIVE_V2
- Request
22 11 70 - Service 22
DID 1170 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Exhaust gas recirculation duty cycle CADILLAC_EGR_DUTY
- Request
22 11 71 - Service 22
DID 1171 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Exhaust gas recirculation duty cycle CADILLAC_EGR_DUTY_V2
- Request
22 11 71 - Service 22
DID 1171 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Exhaust gas recirculation voltage CADILLAC_EGR_V
- Request
22 11 4B - Service 22
DID 114B - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2026.
Exhaust gas recirculation voltage CADILLAC_EGR_V_V2
- Request
22 11 4B - Service 22
DID 114B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2026.
H2 electronics temperature CADILLAC_H2_ELECTRONICS_T
- Request
22 1C 43 - Service 22
DID 1C43 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Heated oxygen sensor CADILLAC_HEATED_OXYGEN_SENS
- Request
22 11 45 - Service 22
DID 1145 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mV
- Unit
- mV
In testing for 2020 to 2026.
Heated oxygen sensor CADILLAC_HEATED_OXYGEN_SENS_V2
- Request
22 11 45 - Service 22
DID 1145 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mV
- Unit
- mV
In testing for 2020 to 2026.
High voltage actively tested vehicle isolation resistance CADILLAC_HIGH_V_ACTIVELY
- Request
22 41 EC - Service 22
DID 41EC - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 Ω
- Unit
- Ω
In testing for 2020 to 2026.
High voltage circuit, hybrid powertrain control module CADILLAC_HIGH_V_CIRCUIT_HPCM
- Request
22 1C 24 - Service 22
DID 1C24 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2020 to 2026.
High voltage current CADILLAC_HIGH_V_CURRENT
- Request
22 43 56 - Service 22
DID 4356 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × -40 ÷ 267)- Range
- -4908 to 4909 A
- Unit
- A
In testing for 2020 to 2026.
High voltage current HD CADILLAC_HIGH_V_CURRENT_HD
- Request
22 24 14 - Service 22
DID 2414 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638 to 1638 A
- Unit
- A
In testing for 2020 to 2026.
High voltage current HD CADILLAC_HIGH_V_CURRENT_HD_V2
- Request
22 43 56 - Service 22
DID 4356 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × -500 ÷ 3333)- Range
- -4915 to 4915 A
- Unit
- A
In testing for 2020 to 2026.
High voltage inverter voltage HD CADILLAC_HIGH_V_INVERTER_V_HD
- Request
22 41 C4 - Service 22
DID 41C4 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40)- Range
- 0 to 1638 V
- Unit
- V
In testing for 2020 to 2026.
High voltage inverter voltage LD CADILLAC_HIGH_V_INVERTER_V_LD
- Request
22 41 DA - Service 22
DID 41DA - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13 ÷ 25)- Range
- 0 to 34078 V
- Unit
- V
In testing for 2020 to 2026.
High voltage isolation test resistance CADILLAC_HIGH_V_ISOLATION
- Request
22 43 A6 - Service 22
DID 43A6 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375 kΩ
- Unit
- kΩ
In testing for 2020 to 2026.
High voltage MG voltage CADILLAC_HIGH_V_MG_V
- Request
22 28 85 - Service 22
DID 2885 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2020 to 2026.
High voltage system interlock circuit CADILLAC_HIGH_V_SYSTEM
- Request
22 43 10 - Service 22
DID 4310 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
High voltage system interlock circuit status CADILLAC_HIGH_V_SYSTEM_INTERLOCK
- Request
22 43 11 - Service 22
DID 4311 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Highest voltage cell number CADILLAC_BAT_CELL_MAX
- Request
22 43 2C - Service 22
DID 432C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Idle air control position CADILLAC_IDLE_AIR_CTRL_POS
- Request
22 11 72 - Service 22
DID 1172 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Idle air control position CADILLAC_IDLE_AIR_CTRL_POS_V2
- Request
22 11 72 - Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Ignition input on/off/start CADILLAC_IGN_INPUT_ON_OFF
- Request
22 20 D0 - Service 22
DID 20D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Ignition input on/off/start CADILLAC_IGN_INPUT_ON_OFF_V2
- Request
22 20 D0 - Service 22
DID 20D0 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Ignition power mode CADILLAC_IGN_POWER_MODE
- Request
22 20 7E - Service 22
DID 207E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Ignition power mode CADILLAC_IGN_POWER_MODE_V2
- Request
22 20 7E - Service 22
DID 207E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Ignition power mode, battery energy control module CADILLAC_IGN_POWER_MODE_BECM
- Request
22 80 02 - Service 22
DID 8002 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Ignition voltage CADILLAC_IGN_V
- Request
22 11 41 - Service 22
DID 1141 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2020 to 2026.
Ignition voltage CADILLAC_IGN_V_V2
- Request
22 11 41 - Service 22
DID 1141 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2020 to 2026.
Injector duty cycle bank 1 CADILLAC_INJECTOR_DUTY_CYCLE_BANK_1
- Request
22 12 C3 - Service 22
DID 12C3 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 150 ÷ 10000)- Range
- 0 to 983.025 ms
- Unit
- ms
In testing for 2020 to 2026.
Injector duty cycle bank 1 CADILLAC_INJECTOR_DUTY_CYCLE_BANK_1_V2
- Request
22 12 C3 - Service 22
DID 12C3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 150 ÷ 10000)- Range
- 0 to 983.025 ms
- Unit
- ms
In testing for 2020 to 2026.
Injector duty cycle bank 2 CADILLAC_INJECTOR_DUTY_CYCLE_BANK_2
- Request
22 12 C4 - Service 22
DID 12C4 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 150 ÷ 10000)- Range
- 0 to 983.025 ms
- Unit
- ms
In testing for 2020 to 2026.
Injector duty cycle bank 2 CADILLAC_INJECTOR_DUTY_CYCLE_BANK_2_V2
- Request
22 12 C4 - Service 22
DID 12C4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 150 ÷ 10000)- Range
- 0 to 983.025 ms
- Unit
- ms
In testing for 2020 to 2026.
Injector pulse width, cylinder 1 CADILLAC_INJ_WIDTH_CYL_1
- Request
22 11 93 - Service 22
DID 1193 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 65.535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Injector pulse width, cylinder 1 CADILLAC_INJ_WIDTH_CYL_1_V2
- Request
22 11 93 - Service 22
DID 1193 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 65.535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Injector pulse width, cylinder 7 CADILLAC_INJ_WIDTH_CYL_7
- Request
22 11 99 - Service 22
DID 1199 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 65.535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Injector pulse width, cylinder 8 CADILLAC_INJ_WIDTH_CYL_8
- Request
22 12 9A - Service 22
DID 129A - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 65.535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Injector pulse width, cylinder 8 CADILLAC_INJ_WIDTH_CYL_8_V2
- Request
22 12 9A - Service 22
DID 129A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 65.535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2020 to 2026.
Intake air temperature 2 CADILLAC_IAT_2
- Request
22 15 38 - Service 22
DID 1538 - Module
DA11 → 2AF111 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Intake air temperature 2 CADILLAC_IAT_2_V2
- Request
22 15 38 - Service 22
DID 1538 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Internal mode switch 1 CADILLAC_INTERNAL_MODE_SWITCH_1
- Request
22 33 C3 - Service 22
DID 33C3 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Internal mode switch 2 CADILLAC_INTERNAL_MODE_SWITCH_2
- Request
22 33 C4 - Service 22
DID 33C4 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Internal mode switch 3 CADILLAC_INTERNAL_MODE_SWITCH_3
- Request
22 33 C5 - Service 22
DID 33C5 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Internal mode switch 4 CADILLAC_INTERNAL_MODE_SWITCH_4
- Request
22 33 C6 - Service 22
DID 33C6 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Internal mode switch 5 CADILLAC_INTERNAL_MODE_SWITCH_5
- Request
22 33 C7 - Service 22
DID 33C7 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Internal mode switch 6 CADILLAC_INTERNAL_MODE_SWITCH_6
- Request
22 33 C8 - Service 22
DID 33C8 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Internal mode switch 7 CADILLAC_INTERNAL_MODE_SWITCH_7
- Request
22 33 C9 - Service 22
DID 33C9 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Internal mode switch 8 CADILLAC_INTERNAL_MODE_SWITCH_8
- Request
22 33 CA - Service 22
DID 33CA - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Internal mode switch 9 CADILLAC_INTERNAL_MODE_SWITCH_9
- Request
22 33 CB - Service 22
DID 33CB - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Internal mode switch 10 CADILLAC_INTERNAL_MODE_SWITCH_10
- Request
22 33 CC - Service 22
DID 33CC - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Internal mode switch 11 CADILLAC_INTERNAL_MODE_SWITCH_11
- Request
22 33 CD - Service 22
DID 33CD - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Knock retard CADILLAC_KNOCK_RETARD
- Request
22 11 A6 - Service 22
DID 11A6 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 22 ÷ 100)- Range
- 0 to 56.1 °
- Unit
- °
In testing for 2020 to 2026.
Knock retard CADILLAC_KNOCK_RETARD_V2
- Request
22 11 A6 - Service 22
DID 11A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 22 ÷ 100)- Range
- 0 to 56.1 °
- Unit
- °
In testing for 2020 to 2026.
Knock retard, alternate CADILLAC_KNOCK_RETARD_ALT
- Request
22 12 5D - Service 22
DID 125D - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °
- Unit
- °
In testing for 2020 to 2026.
Knock retard, alternate CADILLAC_KNOCK_RETARD_ALT_V2
- Request
22 12 5D - Service 22
DID 125D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °
- Unit
- °
In testing for 2020 to 2026.
Knock sensor active counter CADILLAC_KNOCK_SENS_ACTIVE
- Request
22 12 5E - Service 22
DID 125E - Module
DA11 → 2AF111 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Knock sensor active counter CADILLAC_KNOCK_SENS_ACTIVE_V2
- Request
22 12 5E - Service 22
DID 125E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Last shift time CADILLAC_LAST_SHIFT_TIME
- Request
22 19 92 - Service 22
DID 1992 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
Last shift time CADILLAC_LAST_SHIFT_TIME_V2
- Request
22 19 92 - Service 22
DID 1992 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2020 to 2026.
Lowest voltage cell number CADILLAC_BAT_CELL_MIN
- Request
22 43 2A - Service 22
DID 432A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Mass airflow sensor CADILLAC_MAFConfirmed
Pelican can show this parameter as the mass air flow.
- Request
22 00 10 - Service 22
DID 0010 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2023. In testing for 2020 to 2022, 2024 to 2026.
Mass airflow sensor CADILLAC_MAF_7E0
- Request
22 00 10 - Service 22
DID 0010 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 2020 to 2026.
Mass airflow sensor CADILLAC_MAF_DA11
- Request
22 00 10 - Service 22
DID 0010 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 2020 to 2026.
Mass airflow sensor CADILLAC_MAF_V2
Pelican can show this parameter as the mass air flow.
- Request
22 00 10 - Service 22
DID 0010 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 2020 to 2026.
MIL cause CADILLAC_MIL_CAUSE
- Request
22 13 5F - Service 22
DID 135F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
MIL status CADILLAC_MIL_STAT
- Request
22 20 20 - Service 22
DID 2020 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Misfire current, cylinder 7 CADILLAC_MIS_CURRENT_7
- Request
22 11 EC - Service 22
DID 11EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Misfire current, cylinder 8 CADILLAC_MIS_CURRENT_8
- Request
22 11 ED - Service 22
DID 11ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 1 CADILLAC_MIS_HISTORY_1
- Request
22 12 01 - Service 22
DID 1201 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 1 CADILLAC_MIS_HISTORY_1_V2
- Request
22 12 01 - Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 2 CADILLAC_MIS_HISTORY_2
- Request
22 12 02 - Service 22
DID 1202 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 2 CADILLAC_MIS_HISTORY_2_V2
- Request
22 12 02 - Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 3 CADILLAC_MIS_HISTORY_3
- Request
22 12 03 - Service 22
DID 1203 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 3 CADILLAC_MIS_HISTORY_3_V2
- Request
22 12 03 - Service 22
DID 1203 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 4 CADILLAC_MIS_HISTORY_4
- Request
22 12 04 - Service 22
DID 1204 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 4 CADILLAC_MIS_HISTORY_4_V2
- Request
22 12 04 - Service 22
DID 1204 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 5 CADILLAC_MIS_HISTORY_5
- Request
22 11 F8 - Service 22
DID 11F8 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 5 CADILLAC_MIS_HISTORY_5_V2
- Request
22 11 F8 - Service 22
DID 11F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 6 CADILLAC_MIS_HISTORY_6
- Request
22 11 F9 - Service 22
DID 11F9 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 6 CADILLAC_MIS_HISTORY_6_V2
- Request
22 11 F9 - Service 22
DID 11F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 7 CADILLAC_MIS_HISTORY_7
- Request
22 11 FA - Service 22
DID 11FA - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 7 CADILLAC_MIS_HISTORY_7_V2
- Request
22 11 FA - Service 22
DID 11FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 8 CADILLAC_MIS_HISTORY_8
- Request
22 11 FB - Service 22
DID 11FB - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfire history, cylinder 8 CADILLAC_MIS_HISTORY_8_V2
- Request
22 11 FB - Service 22
DID 11FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2020 to 2026.
Misfires, current, cylinder 1 CADILLAC_MISFIRES_C1_CUR
- Request
22 12 06 - Service 22
DID 1206 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Misfires, current, cylinder 1 CADILLAC_MISFIRES_C1_CUR_V2
- Request
22 12 06 - Service 22
DID 1206 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Misfires, current, cylinder 2 CADILLAC_MISFIRES_C2_CUR
- Request
22 12 05 - Service 22
DID 1205 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Misfires, current, cylinder 2 CADILLAC_MISFIRES_C2_CUR_V2
- Request
22 12 05 - Service 22
DID 1205 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Misfires, current, cylinder 3 CADILLAC_MISFIRES_C3_CUR
- Request
22 12 07 - Service 22
DID 1207 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Misfires, current, cylinder 3 CADILLAC_MISFIRES_C3_CUR_V2
- Request
22 12 07 - Service 22
DID 1207 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Misfires, current, cylinder 4 CADILLAC_MISFIRES_C4_CUR
- Request
22 12 08 - Service 22
DID 1208 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Misfires, current, cylinder 4 CADILLAC_MISFIRES_C4_CUR_V2
- Request
22 12 08 - Service 22
DID 1208 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Misfires, current, cylinder 5 CADILLAC_MISFIRES_C5_CUR
- Request
22 11 EA - Service 22
DID 11EA - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Misfires, current, cylinder 5 CADILLAC_MISFIRES_C5_CUR_V2
- Request
22 11 EA - Service 22
DID 11EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Misfires, current, cylinder 6 CADILLAC_MISFIRES_C6_CUR
- Request
22 11 EB - Service 22
DID 11EB - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Misfires, current, cylinder 6 CADILLAC_MISFIRES_C6_CUR_V2
- Request
22 11 EB - Service 22
DID 11EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Misfires, current, cylinder 7 CADILLAC_MISFIRES_C7_CUR
- Request
22 11 EC - Service 22
DID 11EC - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Misfires, current, cylinder 8 CADILLAC_MISFIRES_C8_CUR
- Request
22 11 ED - Service 22
DID 11ED - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Motor control module negative supply isolation voltage CADILLAC_MOTOR_CTRL_MODULE_NEGATIVE_V
- Request
22 44 1A - Service 22
DID 441A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13 ÷ 100)- Range
- 0 to 8519 V
- Unit
- V
In testing for 2020 to 2026.
Motor control module positive supply isolation voltage CADILLAC_MOTOR_CTRL_MODULE_V
- Request
22 44 19 - Service 22
DID 4419 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13 ÷ 100)- Range
- 0 to 8519 V
- Unit
- V
In testing for 2020 to 2026.
Motor controller negative isolation voltage CADILLAC_MOTOR_CONTROLLER_ISOLATION_V
- Request
22 28 D0 - Service 22
DID 28D0 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2020 to 2026.
Motor controller positive isolation voltage CADILLAC_MOTOR_CONTROLLER_V
- Request
22 28 CF - Service 22
DID 28CF - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2020 to 2026.
Motor inverter active CADILLAC_MOTOR_INVERTER
- Request
22 28 81 - Service 22
DID 2881 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Motor inverter temperature sensor 1 CADILLAC_MOTOR_INVERTER_T_1
- Request
22 1C 26 - Service 22
DID 1C26 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Motor inverter temperature sensor 2 CADILLAC_MOTOR_INVERTER_T_2
- Request
22 1C 28 - Service 22
DID 1C28 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Motor inverter temperature sensor 3 CADILLAC_MOTOR_INVERTER_T_3
- Request
22 1C 2A - Service 22
DID 1C2A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Motor phase U current CADILLAC_MOTOR_PHASE_U
- Request
22 28 DE - Service 22
DID 28DE - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 25)- Range
- -1310 to 1310 A
- Unit
- A
In testing for 2020 to 2026.
Motor phase V current CADILLAC_MOTOR_PHASE_V
- Request
22 28 E1 - Service 22
DID 28E1 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 25)- Range
- -1310 to 1310 A
- Unit
- A
In testing for 2020 to 2026.
Motor phase W current CADILLAC_MOTOR_PHASE_W
- Request
22 28 E4 - Service 22
DID 28E4 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 25)- Range
- -1310 to 1310 A
- Unit
- A
In testing for 2020 to 2026.
Motor position sensor offset learn status CADILLAC_MOTOR_POS_SENS
- Request
22 28 CD - Service 22
DID 28CD - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Motor temperature CADILLAC_MOTOR_T
- Request
22 28 CB - Service 22
DID 28CB - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Motor-generator A current CADILLAC_MGA_CURRENT
- Request
22 28 83 - Service 22
DID 2883 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2020 to 2026.
Motor-generator B current CADILLAC_MGB_CURRENT
- Request
22 28 84 - Service 22
DID 2884 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2020 to 2026.
One pedal disengage history 1 CADILLAC_ONE_PEDAL_DISENGAGE_1
- Request
22 36 EE - Service 22
DID 36EE - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal disengage history 2 CADILLAC_ONE_PEDAL_DISENGAGE_2
- Request
22 36 EF - Service 22
DID 36EF - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal disengage history 3 CADILLAC_ONE_PEDAL_DISENGAGE_3
- Request
22 36 F0 - Service 22
DID 36F0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal disengage history 4 CADILLAC_ONE_PEDAL_DISENGAGE_4
- Request
22 36 F1 - Service 22
DID 36F1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal disengage history 5 CADILLAC_ONE_PEDAL_DISENGAGE_5
- Request
22 36 F2 - Service 22
DID 36F2 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal disengage history 6 CADILLAC_ONE_PEDAL_DISENGAGE_6
- Request
22 36 F3 - Service 22
DID 36F3 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal disengage history 7 CADILLAC_ONE_PEDAL_DISENGAGE_7
- Request
22 36 F4 - Service 22
DID 36F4 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal disengage history 8 CADILLAC_ONE_PEDAL_DISENGAGE_8
- Request
22 36 F5 - Service 22
DID 36F5 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal driving inhibit history 1 CADILLAC_ONE_PEDAL_DRIVING_1
- Request
22 36 F6 - Service 22
DID 36F6 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal driving inhibit history 2 CADILLAC_ONE_PEDAL_DRIVING_2
- Request
22 36 F7 - Service 22
DID 36F7 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal driving inhibit history 3 CADILLAC_ONE_PEDAL_DRIVING_3
- Request
22 36 F8 - Service 22
DID 36F8 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal driving inhibit history 4 CADILLAC_ONE_PEDAL_DRIVING_4
- Request
22 36 F9 - Service 22
DID 36F9 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal driving inhibit history 5 CADILLAC_ONE_PEDAL_DRIVING_5
- Request
22 36 FA - Service 22
DID 36FA - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal driving inhibit history 6 CADILLAC_ONE_PEDAL_DRIVING_6
- Request
22 36 FB - Service 22
DID 36FB - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal driving inhibit history 7 CADILLAC_ONE_PEDAL_DRIVING_7
- Request
22 36 FC - Service 22
DID 36FC - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
One pedal driving inhibit history 8 CADILLAC_ONE_PEDAL_DRIVING_8
- Request
22 36 FD - Service 22
DID 36FD - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Outside air temperature CADILLAC_AAT
- Request
22 11 61 - Service 22
DID 1161 - Module
DA11 → 2AF111 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Outside air temperature CADILLAC_AAT_V2
- Request
22 11 61 - Service 22
DID 1161 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Particulate filter pressure CADILLAC_DPF_PRESSConfirmed
- Request
22 34 D8 - Service 22
DID 34D8 - Module
DA11 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 kPa
- Unit
- kPa
Confirmed for 2023. In testing for 2020 to 2022, 2024 to 2026.
Particulate matter sensor soot accumulation CADILLAC_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION
- Request
22 36 35 - Service 22
DID 3635 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Particulate matter sensor soot accumulation CADILLAC_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION_V2
- Request
22 36 35 - Service 22
DID 3635 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Particulate matter sensor temperature CADILLAC_PARTICULATE_MATTER_SNS_T
- Request
22 33 72 - Service 22
DID 3372 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 10000)- Range
- 0 to 6553.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Particulate matter sensor temperature CADILLAC_PARTICULATE_MATTER_SNS_T_V2
- Request
22 33 72 - Service 22
DID 3372 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 10000)- Range
- 0 to 6553.5 °C
- Unit
- °C
In testing for 2020 to 2026.
Pressure control solenoid current, actual CADILLAC_P_CTRL_SOLENOID_ACT
- Request
22 19 9E - Service 22
DID 199E - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2020 to 2026.
Pressure control solenoid current, actual CADILLAC_P_CTRL_SOLENOID_ACT_V2
- Request
22 19 9E - Service 22
DID 199E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2020 to 2026.
Pressure control solenoid current, reference CADILLAC_P_CTRL_SOLENOID
- Request
22 19 9F - Service 22
DID 199F - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2020 to 2026.
Pressure control solenoid current, reference CADILLAC_P_CTRL_SOLENOID_V2
- Request
22 19 9F - Service 22
DID 199F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2020 to 2026.
Regen braking axle torque predicted CADILLAC_REGEN_BRAKING_AXLE_TQ
- Request
22 24 2B - Service 22
DID 242B - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Regen braking axle torque request CADILLAC_REGEN_BRAKING_AXLE
- Request
22 24 26 - Service 22
DID 2426 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Remaining oil life CADILLAC_REMAINING_OIL_LIFE
- Request
22 11 9F - Service 22
DID 119F - Module
DA11 → 2AF111 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2020 to 2026.
Remaining oil life CADILLAC_REMAINING_OIL_LIFE_V2
- Request
22 11 9F - Service 22
DID 119F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2020 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2023. Supported for 2021.
Throttle position calculated CADILLAC_THROTTLE_POS_CALC
- Request
22 28 10 - Service 22
DID 2810 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Throttle position calculated CADILLAC_THROTTLE_POS_CALC_V2
- Request
22 28 10 - Service 22
DID 2810 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Total knock retard CADILLAC_TOTAL_KNOCK_RETARD
- Request
22 12 D9 - Service 22
DID 12D9 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 45 ÷ 100)- Range
- 0 to 114.75 °
- Unit
- °
In testing for 2020 to 2026.
Total knock retard CADILLAC_TOTAL_KNOCK_RETARD_V2
- Request
22 12 D9 - Service 22
DID 12D9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 45 ÷ 100)- Range
- 0 to 114.75 °
- Unit
- °
In testing for 2020 to 2026.
Total misfire CADILLAC_TOTAL_MISFIRE
- Request
22 12 00 - Service 22
DID 1200 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Total misfire CADILLAC_TOTAL_MISFIRE_V2
- Request
22 12 00 - Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Transmission fluid temperature, variant 1 CADILLAC_ATF_T_VAR_1
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 19 40 - Service 22
DID 1940 - Module
DA11 → 2AF111 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Transmission fluid temperature, variant 1 CADILLAC_ATF_T_VAR_1_V2
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 19 40 - Service 22
DID 1940 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Transmission fluid temperature, variant 3 CADILLAC_ATF_T_VAR_3
- Request
22 19 40 - Service 22
DID 1940 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Transmission fluid temperature, variant 5 CADILLAC_ATF_T_VAR_5
- Request
22 19 40 - Service 22
DID 1940 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Transmission fluid temperature, variant 6 CADILLAC_ATF_T_VAR_6
- Request
22 28 0D - Service 22
DID 280D - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Transmission fluid temperature, variant 6 CADILLAC_ATF_T_VAR_8
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 28 0D - Service 22
DID 280D - Module
DA18 → 2AF118 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Transmission fluid temperature, variant 7 CADILLAC_ATF_T_VAR_7
- Request
22 28 0D - Service 22
DID 280D - Module
7E3 → 7EB - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Transmission fluid temperature, variant 8 CADILLAC_ATF_T_VAR_8_V2
- Request
22 28 0D - Service 22
DID 280D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Vent temperature CADILLAC_VENT_T
- Request
22 82 B2 - Service 22
DID 82B2 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 8 − 10)- Range
- -10 to 21.87 °C
- Unit
- °C
In testing for 2020 to 2026.
Engine › OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2023. Supported for 2021.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2023. Supported for 2021.