Audi SQ7

Battery parameters

The Audi SQ7 has 14 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Control module voltage SQ7_VPWRConfirmed

  • Request22 F4 42
  • Service 22DID F442
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2016, 2018 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 15 of the reply, 16 bits.

0x2990 = 10640 → (10640 ÷ 1000) = 10.64 V

Formula
(val ÷ 1000)
Range
0 to 65 V
Unit
V

Confirmed for 2017, 2023. In testing for 2016, 2018 to 2022, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Control module voltage SQ7_VPWRConfirmed

  • Request22 F4 42
  • Service 22DID F442
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2016, 2018 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 15 of the reply, 16 bits.

0x2990 = 10640 → (10640 ÷ 1000) = 10.64 V

Formula
(val ÷ 1000)
Range
0 to 65 V
Unit
V

Confirmed for 2017, 2023. In testing for 2016, 2018 to 2022, 2024 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2023. Supported for 2017.

Maximum charge current SQ7_MAX_CHA_CUR_2Confirmed

  • Request22 11 59
  • Service 22DID 1159
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
-3200 to 3200 A
Unit
A

Confirmed for 2023. In testing for 2016 to 2022, 2024 to 2026.

Maximum discharge current SQ7_MAX_DCHA_CUR_2

  • Request22 11 58
  • Service 22DID 1158
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3200 to 3200 A
Unit
A

In testing for 2016 to 2022, 2024 to 2026. Not supported for 2023.

Start/stop battery charge SQ7_SSB_AHConfirmed

  • Request22 2A 0F
  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 2016, 2018 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 7 of the reply, 8 bits.

0x0D = 13 → 13 Ah

Formula
val
Range
0 to 255 Ah
Unit
Ah

Confirmed for 2017, 2023. In testing for 2016, 2018 to 2022, 2024 to 2026.

Start/stop battery current SQ7_SSB_CConfirmed

  • Request22 2A 09
  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing for 2016 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 31 of the reply, 32 bits. The value is signed.

0x00000047 = 71 → (71 ÷ 1000) = 0.071 A

Formula
(val ÷ 1000)
Range
0 to 100 A
Unit
A

Confirmed for 2023. In testing for 2016 to 2022, 2024 to 2026.

Start/stop battery resistance SQ7_SSB_RConfirmed

  • Request22 2A 0E
  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2016, 2018 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 7 of the reply, 8 bits.

0x10 = 16 → (16 × 2 ÷ 10) = 3.2 mΩ

Formula
(val × 2 ÷ 10)
Range
0 to 100 mΩ
Unit
mΩ

Confirmed for 2017, 2023. In testing for 2016, 2018 to 2022, 2024 to 2026.

Start/stop battery sensor temperature SQ7_SSB_SENSOR_TConfirmed

  • Request22 2A 0A
  • Service 22DID 2A0A
  • Module710
  • Every30 s
  • Testing for 2016 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 7 of the reply, 8 bits.

0x40 = 64 → (64 − 40) = 24 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2016, 2018 to 2022, 2024 to 2026. Not supported for 2017.

Start/stop battery sensor temperature SQ7_SSB_TConfirmed

  • Request22 2A 0B
  • Service 22DID 2A0B
  • Module710 → 77A
  • Every1 s
  • Testing for 2016, 2018 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 7 of the reply, 8 bits.

0x3F = 63 → (63 − 40) = 23 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017, 2023. In testing for 2016, 2018 to 2022, 2024 to 2026.

Start/stop battery target voltage SQ7_SSB_VTConfirmed

  • Request22 2A 00
  • Service 22DID 2A00
  • Module710 → 77A
  • Every1 s
  • Testing for 2016 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 10 + 10.6) = 10.6 V

Formula
(val ÷ 10 + 10.6)
Range
0 to 36.1 V
Unit
V

Confirmed for 2023. In testing for 2016 to 2022, 2024 to 2026.

Start/stop battery total charge SQ7_SSB_TOTAL_CHARGE

  • Request22 2A 61
  • Service 22DID 2A61
  • Module710
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 100 Ah
Unit
Ah

In testing for 2016 to 2022, 2024 to 2026. Not supported for 2023.

Start/stop battery total discharge SQ7_SSB_TOTAL_DISCHARGE

  • Request22 2A 61
  • Service 22DID 2A61
  • Module710
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 100 Ah
Unit
Ah

In testing for 2016 to 2022, 2024 to 2026. Not supported for 2023.

Start/stop battery voltage SQ7_SSB_VConfirmed

  • Request22 2A 07
  • Service 22DID 2A07
  • Module710 → 77A
  • Every1 s
  • Testing for 2016, 2018 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 15 of the reply, 16 bits.

0x1A80 = 6784 → (6784 ÷ 1000 + 4) = 10.784 V

Formula
(val ÷ 1000 + 4)
Range
4 to 69.53 V
Unit
V

Confirmed for 2017, 2023. In testing for 2016, 2018 to 2022, 2024 to 2026.

Start/stop battery voltage (at rest) SQ7_SSB_V_RESTConfirmed

  • Request22 2A 10
  • Service 22DID 2A10
  • Module710 → 77A
  • Every1 s
  • Testing for 2016, 2018 to 2022, 2024 to 2026

Example reply from a 2023 Audi SQ7.

Bits 0 to 7 of the reply, 8 bits.

0x1F = 31 → (31 × 54 ÷ 255 + 9) = 15.564706 V

Formula
(val × 54 ÷ 255 + 9)
Range
9 to 63 V
Unit
V

Confirmed for 2017, 2023. In testing for 2016, 2018 to 2022, 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.