Audi S5

Climate parameters

The Audi S5 has 20 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor torque, requested S5_AC_COMP_TConfirmed

  • Request22 10 02
  • Service 22DID 1002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 10) = 0 N·m

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor power, actual S5_AC_CMPR_PWR_ACT

  • Request22 08 00
  • Service 22DID 0800
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

A/C compressor torque, requested S5_AC_COMP_TConfirmed

  • Request22 10 02
  • Service 22DID 1002
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 10) = 0 N·m

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

A/C refrigerant pressure, sensor 1 S5_AC_REFRIG_P_SENS1

  • Request22 4E EF
  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 88 ÷ 10000)
Range
0 to 576.708 bar
Unit
bar

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

A/C refrigerant temperature, sensor 1 S5_AC_REFRIG_T_SENS1

  • Request22 4E EF
  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 10 ÷ 100 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

A/C refrigerant temperature, sensor 1 interior S5_AC_REFRIG_T_SENS1_INT

  • Request22 4E EF
  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 10 ÷ 100 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Air conditioning compressor power consumption S5_PQ35_AC_COMP_PWR

  • Request22 27 D6
  • Service 22DID 27D6
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 25)
Range
0 to 10.2 kW
Unit
kW

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Air conditioning compressor shutdown requirement S5_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENT

  • Request22 38 1A
  • Service 22DID 381A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2015, 2018 to 2026. Not supported for 2016 to 2017.

Air conditioning compressor torque S5_PQ35_AC_COMP_TRQ

  • Request22 10 4B
  • Service 22DID 104B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2007 to 2015, 2018 to 2023, 2025 to 2026. Not supported for 2016 to 2017, 2024.

Ambient air temperature S5_AAT_7E0_7E0

  • Request22 F4 46
  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2026.

Ambient temperature S5_AAT_V2Confirmed

  • Request22 10 04
  • Service 22DID 1004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2023, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 128) = 0 °C

Formula
(val ÷ 128)
Range
-255 to 255 °C
Unit
°C

Confirmed for 2017, 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016, 2023.

Barometric pressure S5_BARO

  • Request22 F4 33
  • Service 22DID F433
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2007 to 2026.

Cabin humidity S5_CABIN_HUMIDITY

  • Request22 27 C4
  • Service 22DID 27C4
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

CO2 content interior S5_CABIN_CO2

  • Request22 42 DB
  • Service 22DID 42DB
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100)
Range
0 to 25500
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Outside humidity S5_HVAC_OUTSIDE_HUM

  • Request22 27 C3
  • Service 22DID 27C3
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Outside temperature S5_AATConfirmed

  • Request22 26 09
  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing for 2007 to 2016, 2018 to 2022, 2025 to 2026

Example reply from a 2024 Audi S5.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x003C = 60 → (60 ÷ 10) = 6 °C

Formula
(val ÷ 10)
Range
-3276.8 to 100 °C
Unit
°C

Confirmed for 2017, 2023 to 2024. In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016.

Recirculation flap actual position S5_MQB_RECIRC_FLAP_ACT

  • Request22 26 1E
  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Recirculation flap fresh air threshold S5_MQB_RECIRC_FLAP_FRESH_THR

  • Request22 26 20
  • Service 22DID 2620
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Recirculation flap target position S5_MQB_RECIRC_FLAP_TRG

  • Request22 26 1F
  • Service 22DID 261F
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Recirculation flap threshold S5_MQB_RECIRC_FLAP_THR

  • Request22 26 21
  • Service 22DID 2621
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2015, 2018 to 2022, 2025 to 2026. Not supported for 2016 to 2017, 2023 to 2024.

Windshield temperature S5_WINDSHIELD_T

  • Request22 27 C4
  • Service 22DID 27C4
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.576 − 38.8)
Range
-38.8 to 108.08 °C
Unit
°C

In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.