Climate parameters
The Audi e-tron has 6 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
Outside humidity ETRON_HVAC_OUTSIDE_HUMConfirmed
- Request
22 27 C3 - Service 22
DID 27C3 - Module
746 → 7B0 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024
Example reply from a 2026 Audi e-tron.
Bits 56 to 63 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2) = 0 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022, 2026. In testing for 2020, 2023 to 2024. Not supported for 2019, 2021.
Outside temperature ETRON_PTC_OUTSIDE_TConfirmed
- Request
22 26 09 - Service 22
DID 2609 - Module
742 → 7AC - Every
1 s - Testing for 2020, 2023 to 2024
Example reply from a 2026 Audi e-tron.
Bits 0 to 7 of the reply, 8 bits.
0x80 = 128 → (128 ÷ 2 − 50) = 14 °C
- Formula
(val ÷ 2 − 50)- Range
- -50 to 77.5 °C
- Unit
- °C
Confirmed for 2019, 2021 to 2022, 2026. In testing for 2020, 2023 to 2024.
Outside temperature ETRON_TRON_AATConfirmed
- Request
22 26 09 - Service 22
DID 2609 - Module
746 → 7B0 - Every
5 s - Testing for 2019 to 2021, 2023 to 2024
Example reply from a 2026 Audi e-tron.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x008C = 140 → (140 ÷ 10) = 14 °C
- Formula
(val ÷ 10)- Range
- -3276.8 to 100 °C
- Unit
- °C
Confirmed for 2022, 2026. In testing for 2020, 2023 to 2024. Not supported for 2019, 2021.
Climate › Heater
Heater current ETRON_PTC_HTR_IConfirmed
- Request
22 47 5F - Service 22
DID 475F - Module
742 → 7AC - Every
1 s - Testing for 2020 to 2021, 2023 to 2024
Example reply from a 2026 Audi e-tron.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 4) = 0 A
- Formula
(val ÷ 4)- Range
- 0 to 63.74 A
- Unit
- A
Confirmed for 2019, 2022, 2026. In testing for 2020, 2023 to 2024. Not supported for 2021.
Heater fluid temperature #1 ETRON_PTC_HTR_FLUID_T1Confirmed
- Request
22 47 5F - Service 22
DID 475F - Module
742 → 7AC - Every
1 s - Testing for 2020 to 2021, 2023 to 2024
Example reply from a 2026 Audi e-tron.
Bits 64 to 71 of the reply, 8 bits.
0x4D = 77 → (77 − 50) = 27 °C
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2019, 2022, 2026. In testing for 2020, 2023 to 2024. Not supported for 2021.
Heater fluid temperature #2 ETRON_PTC_HTR_FLUID_T2Confirmed
- Request
22 47 5F - Service 22
DID 475F - Module
742 → 7AC - Every
1 s - Testing for 2020 to 2021, 2023 to 2024
Example reply from a 2026 Audi e-tron.
Bits 72 to 79 of the reply, 8 bits.
0x4D = 77 → (77 − 50) = 27 °C
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2019, 2022, 2026. In testing for 2020, 2023 to 2024. Not supported for 2021.