Volvo XC60

Climate parameters

The Volvo XC60 has 14 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Ambient air temperature AATConfirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2012, 2017, 2020 to 2021, 2024 to 2026. Supported for 1997, 2015 to 2016, 2018 to 2019, 2022 to 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2012, 2017, 2020 to 2021, 2024 to 2026. Supported for 1997, 2015 to 2016, 2018 to 2019, 2022 to 2023.

Auxiliary water pump duty cycle XC60_AUXILIARY_WATER_PMP

  • Request22 43 36
  • Service 22DID 4336
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Evaporator temperature XC60_EVAPORATOR_T

  • Request22 98 4F
  • Service 22DID 984F
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Evaporator temperature v.2 XC60_EVAPORATOR_T_V_2

  • Request22 98 20
  • Service 22DID 9820
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 16 ÷ 5)
Range
-409 to 406 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Fuel-operated heater, inlet water temperature XC60_FOH_INLET_WATER_T

  • Request22 43 BE
  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Fuel-operated heater, outlet water temperature XC60_FOH_OUTLET_WATER_T

  • Request22 43 BE
  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Heater core temperature XC60_HEAT_EXCHANGER_T

  • Request22 98 50
  • Service 22DID 9850
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Heater core temperature, variant 2 XC60_HEAT_EXCHANGER_T_V_2

  • Request22 43 37
  • Service 22DID 4337
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 16 ÷ 5)
Range
-409 to 406 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High-voltage coolant heater coolant inlet temperature XC60_HVCH_CLT_INLET_T

  • Request22 43 44
  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High-voltage coolant heater coolant outlet temperature XC60_HVCH_CLT_OUTLET_T

  • Request22 43 44
  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High-voltage coolant heater current consumption XC60_HVCH_CURRENT_CONS

  • Request22 43 45
  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 A
Unit
A

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High-voltage coolant heater power consumption XC60_HVCH_POWER_CONS

  • Request22 43 45
  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val × 20)
Range
0 to 1310700 W
Unit
W

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

High-voltage coolant heater required power consumption XC60_HVCH_REQUIRED_POWER

  • Request22 43 45
  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val × 20)
Range
0 to 1310700 W
Unit
W

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Interior temperature XC60_INTERIOR_T

  • Request22 98 43
  • Service 22DID 9843
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4 ÷ 5 − 60)
Range
-60 to 144 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2026. Not supported for 2020.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.