Battery parameters
The Volvo V70 has 353 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery state of charge VOLVO_12V_BAT_ST_CHG
- Request
22 49 46 - Service 22
DID 4946 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1024 ÷ 15625)- Range
- 0 to 4294 %
- Unit
- %
In testing for 1997 to 2016.
12V system voltage, hd VOLVO_EQA_AUX_V_HD
Pelican can show this parameter as the starter battery voltage.
- Request
22 02 01 - Service 22
DID 0201 - Module
624 → 5A4 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 10000)- Range
- 0 to 100 V
- Unit
- V
In testing for 1997 to 2016.
All-wheel drive coupling module voltage VOLVO_MECU_V
- Request
22 DD 02 - Service 22
DID DD02 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 V
- Unit
- V
In testing for 1997 to 2016.
Alternator charge voltage request VOLVO_ALTERNATOR_CHG_V_REQ
- Request
22 41 1D - Service 22
DID 411D - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997 to 2016.
Auxiliary battery current VOLVO_AUXILIARY_BAT
- Request
22 41 12 - Service 22
DID 4112 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 127)- Range
- -127 to 128 A
- Unit
- A
In testing for 1997 to 2016.
Auxiliary battery temperature VOLVO_AUXILIARY_BAT_T
- Request
22 40 D3 - Service 22
DID 40D3 - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1997 to 2016.
Auxiliary battery voltage VOLVO_AUXILIARY_BAT_V
- Request
22 41 7E - Service 22
DID 417E - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997 to 2016.
Auxiliary battery voltage VOLVO_EQA_AUX_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 20 05 - Service 22
DID 2005 - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25.9 ÷ 255)- Range
- 0 to 25.9 V
- Unit
- V
In testing for 1997 to 2016.
Average static low range battery current VOLVO_AVG_STATIC_LOW_RANGE
- Request
22 40 25 - Service 22
DID 4025 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 511)- Range
- -511 to 65024 mA
- Unit
- mA
In testing for 1997 to 2016.
Battery age condition VOLVO_ED_BAT_AGE
- Request
22 63 08 - Service 22
DID 6308 - Module
7E5 → 7ED - Every
600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1997 to 2016.
Battery charge balance, ah VOLVO_BAT_CHG_BALANCE_AH
- Request
22 41 A5 - Service 22
DID 41A5 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1997 to 2016.
Battery charge, amps VOLVO_BAT_CHG_AMPS
- Request
22 40 90 - Service 22
DID 4090 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 511.7)- Range
- -511 to 3584 A
- Unit
- A
In testing for 1997 to 2016.
Battery current VOLVO_BAT_CURRENT
- Request
22 40 90 - Service 22
DID 4090 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 512)- Range
- -512 to 3583 A
- Unit
- A
In testing for 1997 to 2016.
Battery heater on VOLVO_ED_HEATER_ON
- Request
22 D3 02 - Service 22
DID D302 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1997 to 2016.
Battery module 1 temperature VOLVO_ED_MOD_T1
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
Battery module 2 temperature VOLVO_ED_MOD_T2
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
Battery module 3 temperature VOLVO_ED_MOD_T3
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
Battery module 4 temperature VOLVO_ED_MOD_T4
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
Battery module 5 temperature VOLVO_ED_MOD_T5
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
Battery module 6 temperature VOLVO_ED_MOD_T6
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
Battery module 7 temperature VOLVO_ED_MOD_T7
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
Battery module 8 temperature VOLVO_ED_MOD_T8
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
Battery module 9 temperature VOLVO_ED_MOD_T9
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
Battery operating mode VOLVO_EV_MODE
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 7
- Unit
- Number
In testing for 1997 to 2016.
Battery operation time since battery monitoring sensor reset, days VOLVO_BAT_OPERATION_TIME
- Request
22 40 27 - Service 22
DID 4027 - Module
726 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1997 to 2016.
Battery relay VOLVO_BAT_RELAY
- Request
22 D9 53 - Service 22
DID D953 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2016.
Battery state of charge VOLVO_BAT_ST_CHG
- Request
22 40 28 - Service 22
DID 4028 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 1997 to 2016.
Battery state of charge VOLVO_BAT_ST_CHG_726
- Request
22 40 28 - Service 22
DID 4028 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1997 to 2016.
Battery temperature VOLVO_BAT_T
- Request
22 40 29 - Service 22
DID 4029 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2016.
Battery voltage VOLVO_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 CD - Service 22
DID 40CD - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 + 5)- Range
- 0 to 1643 V
- Unit
- V
In testing for 1997 to 2016.
Battery voltage VOLVO_BAT_V_726
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 2A - Service 22
DID 402A - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20 + 6)- Range
- 0 to 18.75 V
- Unit
- V
In testing for 1997 to 2016.
Boost pressure after turbocharger VOLVO_BOOST_P_AFTER
- Request
22 03 3E - Service 22
DID 033E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 131 − 0.053435)- Range
- -0.0534 to 500 kPa
- Unit
- kPa
In testing for 1997 to 2016.
Capacity loss VOLVO_CAP_LOSS
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1997 to 2016.
Cell capacity, average VOLVO_ED_CAP_AS_AVG
- Request
22 03 10 - Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 1997 to 2016.
Cell capacity, maximum VOLVO_ED_CAP_AS_MAX
- Request
22 03 10 - Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 1997 to 2016.
Cell capacity, minimum VOLVO_ED_CAP_AS_MIN
- Request
22 03 10 - Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 1997 to 2016.
Cell voltage reference, average VOLVO_ED_ADC_V_AVG
- Request
22 02 07 - Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 1997 to 2016.
Cell voltage reference, maximum VOLVO_ED_ADC_V_MAX
- Request
22 02 07 - Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val + 1500)- Range
- 1500 to 67035 mV
- Unit
- mV
In testing for 1997 to 2016.
Cell voltage reference, minimum VOLVO_ED_ADC_V_MIN
- Request
22 02 07 - Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val + 1500)- Range
- 1500 to 67035 mV
- Unit
- mV
In testing for 1997 to 2016.
Charge air pressure VOLVO_CHG_AIR_P
- Request
22 EE 3E - Service 22
DID EE3E - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.007812)- Range
- 0 to 511 kPa
- Unit
- kPa
In testing for 1997 to 2016.
Charge power limit VOLVO_CHG_POWER_LIM
- Request
22 48 9C - Service 22
DID 489C - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val × 4 ÷ 15625)- Range
- 0 to 4294 kW
- Unit
- kW
In testing for 1997 to 2016.
Charger 12V output voltage VOLVO_ED_OBL_LV
- Request
22 02 26 - Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997 to 2016.
Charger cable current VOLVO_CHARGER_CABLE
- Request
22 EE 8D - Service 22
DID EE8D - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 410)- Range
- -410 to 6143 A
- Unit
- A
In testing for 1997 to 2016.
Charger cooling plate temperature VOLVO_ED_OBL_PLATE_T
- Request
22 02 23 - Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2016.
Charger current set point VOLVO_ED_OBL_A_SET
- Request
22 02 2A - Service 22
DID 022A - Module
61A → 483 - Every
60 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 1997 to 2016.
Charger HV output current VOLVO_ED_OBL_HV_A
- Request
22 02 25 - Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 204.7 A
- Unit
- A
In testing for 1997 to 2016.
Charger HV output voltage VOLVO_ED_OBL_HV
- Request
22 02 26 - Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 819 V
- Unit
- V
In testing for 1997 to 2016.
Charger mains current VOLVO_ED_OBL_MAINS_A
- Request
22 02 25 - Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 204.7 A
- Unit
- A
In testing for 1997 to 2016.
Charger mains current, phase 1 VOLVO_OBL_A1
- Request
22 73 03 - Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 5990.4 A
- Unit
- A
In testing for 1997 to 2016.
Charger mains current, phase 2 VOLVO_OBL_A2
- Request
22 73 03 - Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 5990.4 A
- Unit
- A
In testing for 1997 to 2016.
Charger mains voltage VOLVO_ED_OBL_MAINS_V
- Request
22 02 26 - Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 819 V
- Unit
- V
In testing for 1997 to 2016.
Charger mains voltage VOLVO_OBL_V
- Request
22 73 03 - Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 5990.4 V
- Unit
- V
In testing for 1997 to 2016.
Charger power 1 VOLVO_OBL_P1
- Request
22 73 03 - Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 2000)- Range
- 0 to 29.952 kW
- Unit
- kW
In testing for 1997 to 2016.
Charger power 2 VOLVO_OBL_P2
- Request
22 73 03 - Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 2000)- Range
- 0 to 29.952 kW
- Unit
- kW
In testing for 1997 to 2016.
Charger temperature VOLVO_ED_OBL_T
- Request
22 02 23 - Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2016.
Charging cable current code VOLVO_ED_OBL_CABLE_A
- Request
22 02 25 - Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 1997 to 2016.
Charging plug detected VOLVO_PLUG
Pelican can show this parameter as the plug state.
- Request
22 33 9D - Service 22
DID 339D - Module
7E4 → 7EC - Every
5 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1997 to 2016.
Charging socket lock VOLVO_CHG_SOCKET_LOCKED
- Request
22 EE 8C - Service 22
DID EE8C - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | UNLOCKED | Unlocked |
2 | LOCKED | Locked |
In testing for 1997 to 2016.
Charging socket temperature VOLVO_ED_OBL_SOCKET_T
- Request
22 02 23 - Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2016.
Control module supply voltage VOLVO_ENG_CTRL_MODULE_SUP_V
- Request
22 F4 42 - Service 22
DID F442 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 1997 to 2016.
Control module voltage VOLVO_CTRL_MODULE_V_MS_CAN
- Request
22 D9 04 - Service 22
DID D904 - Module
784 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1997 to 2016.
DC charger current VOLVO_DC_CHARGER_CURRENT
- Request
22 EE 16 - Service 22
DID EE16 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 1997 to 2016.
DC charger voltage VOLVO_DC_CHARGER_V
- Request
22 EE 17 - Service 22
DID EE17 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 1997 to 2016.
DC converter requested voltage VOLVO_EQA_CNVRTR_REQ_V
- Request
22 60 71 - Service 22
DID 6071 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 250 ÷ 10000)- Range
- 0 to 100 V
- Unit
- V
In testing for 1997 to 2016.
Discharge power limit VOLVO_DCHG_POWER_LIM
- Request
22 48 9E - Service 22
DID 489E - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val × 4 ÷ 15625)- Range
- 0 to 4294 kW
- Unit
- kW
In testing for 1997 to 2016.
Estimated capacity VOLVO_CAP_EST
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 360)- Range
- 0 to 182.0416 Ah
- Unit
- Ah
In testing for 1997 to 2016.
External temperature sensor, HV battery cooling module VOLVO_EXTERNAL_T_SENS
- Request
22 EE 46 - Service 22
DID EE46 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1997 to 2016.
Front camera voltage supply VOLVO_FRONT_CAMERA_V_SUP
- Request
22 99 69 - Service 22
DID 9969 - Module
764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 20.4 V
- Unit
- V
In testing for 1997 to 2016.
Fuse DC charging voltage VOLVO_FUSE_DC_CHG_V
- Request
22 49 8B - Service 22
DID 498B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 1997 to 2016.
High voltage battery - voltage at IEM fuse VOLVO_HVBAT_V_IEM_FUSE
- Request
22 48 59 - Service 22
DID 4859 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 1997 to 2016.
High voltage battery - voltage at IHFA fuse VOLVO_HVBAT_V_IHFA_FUSE
- Request
22 48 58 - Service 22
DID 4858 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 1997 to 2016.
High voltage battery cell voltage sum VOLVO_HVBAT_CELL_VOLTAGES
- Request
22 49 7C - Service 22
DID 497C - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1997 to 2016.
High voltage battery contactor voltage VOLVO_HVBAT_CONTACTOR_V
- Request
22 48 57 - Service 22
DID 4857 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 1997 to 2016.
High voltage battery coolant inlet temperature VOLVO_HVBAT_CLT_INLET_T
- Request
22 48 04 - Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 1997 to 2016.
High voltage battery coolant outlet temperature VOLVO_HVBAT_CLT_OUTLET_T
- Request
22 49 90 - Service 22
DID 4990 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 1997 to 2016.
High voltage battery current VOLVO_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 48 02 - Service 22
DID 4802 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 A
- Unit
- A
In testing for 1997 to 2016.
High voltage battery negative contactor voltage VOLVO_HVBAT_NEGATIVE_V
- Request
22 4A 58 - Service 22
DID 4A58 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 V
- Unit
- V
In testing for 1997 to 2016.
High voltage battery state of charge VOLVO_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131 %
- Unit
- %
In testing for 1997 to 2016.
High voltage battery state of health VOLVO_HVBAT_ST_HEALTH
Pelican can show this parameter as the state of health.
- Request
22 49 6D - Service 22
DID 496D - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100)- Range
- 0 to 42949672 %
- Unit
- %
In testing for 1997 to 2016.
High voltage battery voltage VOLVO_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 48 03 - Service 22
DID 4803 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1997 to 2016.
High voltage battery, average temperature VOLVO_HVBAT_AVG_T
- Request
22 49 1B - Service 22
DID 491B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 1997 to 2016.
High voltage battery, coolant pump speed, actual VOLVO_HVBAT_CLT_PMP_SPD_ACT
- Request
22 48 67 - Service 22
DID 4867 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 1997 to 2016.
High voltage battery, coolant pump speed, requested VOLVO_HVBAT_CLT_PMP_SPD
- Request
22 48 66 - Service 22
DID 4866 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 1997 to 2016.
High voltage battery, high-voltage coolant heater fuse voltage VOLVO_HVBAT_HVCH_FUSE_V
- Request
22 48 0A - Service 22
DID 480A - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1997 to 2016.
High voltage battery, IEM fuse voltage VOLVO_HVBAT_IEM_FUSE_V
- Request
22 48 08 - Service 22
DID 4808 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1997 to 2016.
High voltage battery, IGM fuse voltage VOLVO_HVBAT_IGM_FUSE_V
- Request
22 48 09 - Service 22
DID 4809 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1997 to 2016.
High voltage battery, inlet coolant temperature VOLVO_HVBAT_INLET_ECT
- Request
22 48 04 - Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1997 to 2016.
High voltage battery, max temperature VOLVO_HVBAT_MAX_T
- Request
22 49 45 - Service 22
DID 4945 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 1997 to 2016.
High voltage battery, OBC fuse voltage VOLVO_HVBAT_OBC_FUSE_V
- Request
22 48 0B - Service 22
DID 480B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1997 to 2016.
High voltage system voltage VOLVO_HIGH_V_SYSTEM_V
- Request
22 98 5C - Service 22
DID 985C - Module
D016 → 1EC6EE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 V
- Unit
- V
In testing for 1997 to 2016.
High voltage system voltage VOLVO_HIGH_V_SYSTEM_V_D016
- Request
22 98 5C - Service 22
DID 985C - Module
D016 → 1ED24E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 V
- Unit
- V
In testing for 1997 to 2016.
Highest cell voltage VOLVO_CELL_V_MAX
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
HV battery amperage VOLVO_EQA_HV_A
- Request
22 60 53 - Service 22
DID 6053 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- 0 to 100 A
- Unit
- A
In testing for 1997 to 2016.
HV battery available energy VOLVO_HV_E
- Request
22 32 0C - Service 22
DID 320C - Module
7E4 → 7EC - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327.675 kWh
- Unit
- kWh
In testing for 1997 to 2016.
HV battery coolant temperature VOLVO_EQA_HV_COOLANT_T
- Request
22 25 26 - Service 22
DID 2526 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1250 ÷ 10000)- Range
- 0 to 100 °C
- Unit
- °C
In testing for 1997 to 2016.
HV battery current VOLVO_ED_HV_A
- Request
22 02 03 - Service 22
DID 0203 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.9687 A
- Unit
- A
In testing for 1997 to 2016.
HV battery current VOLVO_HV_A
Pelican can show this parameter as the traction battery current.
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
(val × -1 ÷ 32)- Range
- -1023.9687 to 1024 A
- Unit
- A
In testing for 1997 to 2016.
HV battery open-circuit voltage VOLVO_OCV
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 1997 to 2016.
HV battery state of charge VOLVO_EQA_HV_SOC
Pelican can show this parameter as the state of charge.
- Request
22 60 50 - Service 22
DID 6050 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 1997 to 2016.
HV battery temperature VOLVO_ED_HV_T
- Request
22 02 01 - Service 22
DID 0201 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
HV battery temperature, average VOLVO_HV_T_AVG
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
HV battery temperature, maximum VOLVO_HV_T_MAX
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
HV battery temperature, minimum VOLVO_HV_T_MIN
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 1997 to 2016.
HV battery voltage VOLVO_ED_HV_V
- Request
22 02 04 - Service 22
DID 0204 - Module
7E7 → 7EF - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 1997 to 2016.
HV battery voltage VOLVO_EQA_HV_V
- Request
22 60 75 - Service 22
DID 6075 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 25 ÷ 1000)- Range
- 0 to 100 V
- Unit
- V
In testing for 1997 to 2016.
HV battery voltage VOLVO_HV_V
Pelican can show this parameter as the traction battery voltage.
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 1997 to 2016.
HV contactor cycles remaining VOLVO_ED_CONT_LEFT
- Request
22 03 0B - Service 22
DID 030B - Module
7E7 → 7EF - Every
600 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215
- Unit
- Number
In testing for 1997 to 2016.
HV contactor cycles remaining VOLVO_HV_CONT_LEFT
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1997 to 2016.
HV contactor cycles, maximum VOLVO_ED_CONT_MAX
- Request
22 03 0C - Service 22
DID 030C - Module
7E7 → 7EF - Every
600 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215
- Unit
- Number
In testing for 1997 to 2016.
HV contactor cycles, maximum VOLVO_HV_CONT_MAX
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1997 to 2016.
HV contactor state VOLVO_ED_CONTACTOR
- Request
22 D0 00 - Service 22
DID D000 - Module
7E7 → 7EF - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2016.
HV contactor state VOLVO_HV_CONTACTOR
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 3
- Unit
- Number
In testing for 1997 to 2016.
HV DC fault code VOLVO_ED_DC_FAULT
- Request
22 02 09 - Service 22
DID 0209 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2016.
HV isolation resistance VOLVO_ED_ISO
- Request
22 02 09 - Service 22
DID 0209 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65534 kΩ
- Unit
- kΩ
In testing for 1997 to 2016.
HV link voltage VOLVO_HV_LINK_V
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 1997 to 2016.
HV plug interlock closed VOLVO_HV_INTERLOCK_PLUG
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1997 to 2016.
Initial capacity VOLVO_CAP_INIT
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 360)- Range
- 0 to 182.0416 Ah
- Unit
- Ah
In testing for 1997 to 2016.
Leakage current, 10 kilohertz VOLVO_LEAK_HF10
- Request
22 50 66 - Service 22
DID 5066 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1997 to 2016.
Leakage DC current VOLVO_LEAK_DC
- Request
22 50 65 - Service 22
DID 5065 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1997 to 2016.
Leakage diagnostic code VOLVO_LEAK_DIAG
- Request
22 50 64 - Service 22
DID 5064 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2016.
Leakage high-frequency current VOLVO_LEAK_HF
- Request
22 50 67 - Service 22
DID 5067 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1997 to 2016.
Leakage low-frequency current VOLVO_LEAK_LF
- Request
22 50 68 - Service 22
DID 5068 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1997 to 2016.
Lowest cell voltage VOLVO_CELL_V_MIN
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Main charger current VOLVO_MAIN_CHARGER_CURRENT
- Request
22 EE 15 - Service 22
DID EE15 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 1997 to 2016.
Main charger voltage VOLVO_MAIN_CHARGER_V
- Request
22 EE 1C - Service 22
DID EE1C - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 1997 to 2016.
Mains active power VOLVO_MAINS_P
- Request
22 50 4A - Service 22
DID 504A - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 20)- Range
- -20 to 45.5349 kW
- Unit
- kW
In testing for 1997 to 2016.
Mains current limit VOLVO_MAINS_A_LIMIT
- Request
22 50 70 - Service 22
DID 5070 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1997 to 2016.
Mains current, phase 2 VOLVO_MAINS_A_2
- Request
22 50 3A - Service 22
DID 503A - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 200)- Range
- -200 to 3895.9375 A
- Unit
- A
In testing for 1997 to 2016.
Mains current, phase 3 VOLVO_MAINS_A_3
- Request
22 50 3B - Service 22
DID 503B - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 200)- Range
- -200 to 3895.9375 A
- Unit
- A
In testing for 1997 to 2016.
Mains frequency VOLVO_MAINS_HZ
- Request
22 50 49 - Service 22
DID 5049 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128 + 10)- Range
- 10 to 521.9921 Hz
- Unit
- Hz
In testing for 1997 to 2016.
Mains ground resistance VOLVO_MAINS_GND_R
- Request
22 50 62 - Service 22
DID 5062 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 1997 to 2016.
Mains voltage, phases 1-2 VOLVO_MAINS_V_12
- Request
22 50 3F - Service 22
DID 503F - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 1997 to 2016.
Mains voltage, phases 2-3 VOLVO_MAINS_V_23
- Request
22 50 41 - Service 22
DID 5041 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 1997 to 2016.
Mains voltage, phases 3-1 VOLVO_MAINS_V_31
- Request
22 50 42 - Service 22
DID 5042 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 1997 to 2016.
Module voltage VOLVO_MODULE_V
- Request
22 D1 11 - Service 22
DID D111 - Module
D016 → 1EC70E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997 to 2016.
Open-circuit voltage state VOLVO_OCV_STATE
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
val- Range
- 0 to 4
- Unit
- Number
In testing for 1997 to 2016.
Real state of charge, maximum VOLVO_SOC_REAL_MAX
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1997 to 2016.
Real state of charge, minimum VOLVO_SOC_REAL_MIN
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1997 to 2016.
Secondary battery charge time VOLVO_SECONDARY_BAT_CHG
- Request
22 EE D3 - Service 22
DID EED3 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1997 to 2016.
Secondary battery needed charge time VOLVO_SECONDARY_BAT_NEEDED
- Request
22 EE D5 - Service 22
DID EED5 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1997 to 2016.
Secondary battery relay VOLVO_SECONDARY_BAT_RELAY
- Request
22 41 9C - Service 22
DID 419C - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2016.
Secondary battery temperature VOLVO_SECONDARY_BAT_T_25_C
- Request
22 EE D2 - Service 22
DID EED2 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2016.
Secondary battery voltage VOLVO_SECONDARY_BAT_V
- Request
22 41 7E - Service 22
DID 417E - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997 to 2016.
Secondary battery voltage average value VOLVO_SECONDARY_BAT_V_AVG
- Request
22 EE D7 - Service 22
DID EED7 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997 to 2016.
Secondary battery voltage latest stored VOLVO_SECONDARY_BAT_V_LATEST
- Request
22 EE D4 - Service 22
DID EED4 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997 to 2016.
Service interlock closed VOLVO_HV_INTERLOCK_SVC
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1997 to 2016.
Servo supply voltage VOLVO_SERVO_SUP_V
- Request
22 41 3D - Service 22
DID 413D - Module
730 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997 to 2016.
Start/stop battery relay VOLVO_START_STOP_BAT_RELAY
- Request
22 EF 51 - Service 22
DID EF51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2016.
Start/stop secondary battery relay VOLVO_START_STOP_SECONDARY
- Request
22 EF 52 - Service 22
DID EF52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2016.
State of charge VOLVO_SOC
- Request
22 40 28 - Service 22
DID 4028 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 1997 to 2001, 2003, 2005 to 2006, 2008 to 2016. Not supported for 2002, 2004, 2007.
State of charge VOLVO_SOC_V2
Pelican can show this parameter as the state of charge.
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1997 to 2016.
State of charge recalibration state VOLVO_SOC_RECAL
- Request
21 25 - Service 21
PID 25 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 3
- Unit
- Number
In testing for 1997 to 2016.
State of charge, displayed VOLVO_SOC_DISPLAY
- Request
21 25 - Service 21
PID 25 - Module
79B → 7BB - Every
60 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 1997 to 2016.
State of health VOLVO_SOH
Pelican can show this parameter as the state of health.
- Request
21 61 - Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 %
- Unit
- %
In testing for 1997 to 2016.
State of health, raw VOLVO_ED_SOH
- Request
22 03 10 - Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2016.
Sum of cell voltages VOLVO_HV_CELL_SUM_V
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 1997 to 2016.
Supercharger clutch, requested position VOLVO_SUPERCHARGER_CLU_REQ
- Request
22 EE 84 - Service 22
DID EE84 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2016.
Time with HV off VOLVO_ED_HV_OFF_TIME
- Request
22 03 10 - Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 s
- Unit
- s
In testing for 1997 to 2016.
Transmission control module supply voltage VOLVO_MECU_SUP_V
- Request
22 DD 02 - Service 22
DID DD02 - Module
7E1 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 V
- Unit
- V
In testing for 1997 to 2016.
Usable capacity, full VOLVO_CAP_FULL
- Request
21 61 - Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 360)- Range
- -91.0222 to 91.0194 Ah
- Unit
- Ah
In testing for 1997 to 2016.
Voltage supply VOLVO_V_SUP
- Request
22 D9 01 - Service 22
DID D901 - Module
737 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 20.4 V
- Unit
- V
In testing for 1997 to 2016.
Voltage supply VOLVO_V_SUP_764
- Request
22 D1 12 - Service 22
DID D112 - Module
764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 20.4 V
- Unit
- V
In testing for 1997 to 2016.
Voltage supply VOLVO_V_SUP_MS_CAN
- Request
22 D1 11 - Service 22
DID D111 - Module
791 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1997 to 2016.
Voltage/power sensitive loads connected VOLVO_V_POWER_SENSITIVE
- Request
22 EE A2 - Service 22
DID EEA2 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1997 to 2016.
Battery › Cells
Cell 1 voltage VOLVO_CELL_V1
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 1 voltage VOLVO_ED_CELL_V1
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 2 voltage VOLVO_CELL_V2
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 2 voltage VOLVO_ED_CELL_V2
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 3 voltage VOLVO_CELL_V3
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 3 voltage VOLVO_ED_CELL_V3
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 4 voltage VOLVO_CELL_V4
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 4 voltage VOLVO_ED_CELL_V4
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 5 voltage VOLVO_CELL_V5
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 5 voltage VOLVO_ED_CELL_V5
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 6 voltage VOLVO_CELL_V6
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 6 voltage VOLVO_ED_CELL_V6
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 7 voltage VOLVO_CELL_V7
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 7 voltage VOLVO_ED_CELL_V7
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 8 voltage VOLVO_CELL_V8
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 8 voltage VOLVO_ED_CELL_V8
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 9 voltage VOLVO_CELL_V9
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 9 voltage VOLVO_ED_CELL_V9
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 10 voltage VOLVO_CELL_V10
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 10 voltage VOLVO_ED_CELL_V10
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 11 voltage VOLVO_CELL_V11
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 11 voltage VOLVO_ED_CELL_V11
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 12 voltage VOLVO_CELL_V12
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 12 voltage VOLVO_ED_CELL_V12
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 13 voltage VOLVO_CELL_V13
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 13 voltage VOLVO_ED_CELL_V13
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 14 voltage VOLVO_CELL_V14
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 14 voltage VOLVO_ED_CELL_V14
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 15 voltage VOLVO_CELL_V15
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 15 voltage VOLVO_ED_CELL_V15
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 16 voltage VOLVO_CELL_V16
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 16 voltage VOLVO_ED_CELL_V16
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 17 voltage VOLVO_CELL_V17
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 17 voltage VOLVO_ED_CELL_V17
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 18 voltage VOLVO_CELL_V18
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 18 voltage VOLVO_ED_CELL_V18
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 19 voltage VOLVO_CELL_V19
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 19 voltage VOLVO_ED_CELL_V19
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 20 voltage VOLVO_CELL_V20
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 20 voltage VOLVO_ED_CELL_V20
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 21 voltage VOLVO_CELL_V21
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 21 voltage VOLVO_ED_CELL_V21
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 22 voltage VOLVO_CELL_V22
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 22 voltage VOLVO_ED_CELL_V22
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 23 voltage VOLVO_CELL_V23
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 23 voltage VOLVO_ED_CELL_V23
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 24 voltage VOLVO_CELL_V24
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 24 voltage VOLVO_ED_CELL_V24
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 25 voltage VOLVO_CELL_V25
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 25 voltage VOLVO_ED_CELL_V25
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 26 voltage VOLVO_CELL_V26
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 26 voltage VOLVO_ED_CELL_V26
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 27 voltage VOLVO_CELL_V27
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 27 voltage VOLVO_ED_CELL_V27
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 28 voltage VOLVO_CELL_V28
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 28 voltage VOLVO_ED_CELL_V28
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 29 voltage VOLVO_CELL_V29
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 29 voltage VOLVO_ED_CELL_V29
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 30 voltage VOLVO_CELL_V30
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 30 voltage VOLVO_ED_CELL_V30
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 31 voltage VOLVO_CELL_V31
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 31 voltage VOLVO_ED_CELL_V31
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 32 voltage VOLVO_CELL_V32
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 32 voltage VOLVO_ED_CELL_V32
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 33 voltage VOLVO_CELL_V33
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 33 voltage VOLVO_ED_CELL_V33
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 34 voltage VOLVO_CELL_V34
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 34 voltage VOLVO_ED_CELL_V34
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 35 voltage VOLVO_CELL_V35
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 35 voltage VOLVO_ED_CELL_V35
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 36 voltage VOLVO_CELL_V36
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 36 voltage VOLVO_ED_CELL_V36
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 37 voltage VOLVO_CELL_V37
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 37 voltage VOLVO_ED_CELL_V37
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 38 voltage VOLVO_CELL_V38
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 38 voltage VOLVO_ED_CELL_V38
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 39 voltage VOLVO_CELL_V39
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 39 voltage VOLVO_ED_CELL_V39
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 40 voltage VOLVO_CELL_V40
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 40 voltage VOLVO_ED_CELL_V40
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 41 voltage VOLVO_CELL_V41
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 41 voltage VOLVO_ED_CELL_V41
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 42 voltage VOLVO_CELL_V42
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 42 voltage VOLVO_ED_CELL_V42
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 43 voltage VOLVO_CELL_V43
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 43 voltage VOLVO_ED_CELL_V43
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 44 voltage VOLVO_CELL_V44
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 44 voltage VOLVO_ED_CELL_V44
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 45 voltage VOLVO_CELL_V45
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 45 voltage VOLVO_ED_CELL_V45
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 46 voltage VOLVO_CELL_V46
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 46 voltage VOLVO_ED_CELL_V46
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 47 voltage VOLVO_CELL_V47
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 47 voltage VOLVO_ED_CELL_V47
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 48 voltage VOLVO_CELL_V48
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 48 voltage VOLVO_ED_CELL_V48
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 49 voltage VOLVO_CELL_V49
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 49 voltage VOLVO_ED_CELL_V49
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 50 voltage VOLVO_CELL_V50
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 50 voltage VOLVO_ED_CELL_V50
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 51 voltage VOLVO_CELL_V51
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 51 voltage VOLVO_ED_CELL_V51
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 52 voltage VOLVO_CELL_V52
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 52 voltage VOLVO_ED_CELL_V52
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 53 voltage VOLVO_CELL_V53
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 53 voltage VOLVO_ED_CELL_V53
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 54 voltage VOLVO_CELL_V54
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 54 voltage VOLVO_ED_CELL_V54
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 55 voltage VOLVO_CELL_V55
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 55 voltage VOLVO_ED_CELL_V55
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 56 voltage VOLVO_CELL_V56
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 56 voltage VOLVO_ED_CELL_V56
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 57 voltage VOLVO_CELL_V57
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 57 voltage VOLVO_ED_CELL_V57
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 58 voltage VOLVO_CELL_V58
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 58 voltage VOLVO_ED_CELL_V58
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 59 voltage VOLVO_CELL_V59
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 59 voltage VOLVO_ED_CELL_V59
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 60 voltage VOLVO_CELL_V60
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 60 voltage VOLVO_ED_CELL_V60
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 61 voltage VOLVO_CELL_V61
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 61 voltage VOLVO_ED_CELL_V61
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 62 voltage VOLVO_CELL_V62
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 62 voltage VOLVO_ED_CELL_V62
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 63 voltage VOLVO_CELL_V63
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 63 voltage VOLVO_ED_CELL_V63
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 64 voltage VOLVO_CELL_V64
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 64 voltage VOLVO_ED_CELL_V64
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 65 voltage VOLVO_CELL_V65
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 65 voltage VOLVO_ED_CELL_V65
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 66 voltage VOLVO_CELL_V66
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 66 voltage VOLVO_ED_CELL_V66
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 67 voltage VOLVO_CELL_V67
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 67 voltage VOLVO_ED_CELL_V67
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 68 voltage VOLVO_CELL_V68
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 68 voltage VOLVO_ED_CELL_V68
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 69 voltage VOLVO_CELL_V69
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 69 voltage VOLVO_ED_CELL_V69
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 70 voltage VOLVO_CELL_V70
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 70 voltage VOLVO_ED_CELL_V70
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 71 voltage VOLVO_CELL_V71
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 71 voltage VOLVO_ED_CELL_V71
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 72 voltage VOLVO_CELL_V72
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 72 voltage VOLVO_ED_CELL_V72
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 73 voltage VOLVO_CELL_V73
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 73 voltage VOLVO_ED_CELL_V73
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 74 voltage VOLVO_CELL_V74
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 74 voltage VOLVO_ED_CELL_V74
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 75 voltage VOLVO_CELL_V75
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 75 voltage VOLVO_ED_CELL_V75
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 76 voltage VOLVO_CELL_V76
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 76 voltage VOLVO_ED_CELL_V76
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 77 voltage VOLVO_CELL_V77
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 77 voltage VOLVO_ED_CELL_V77
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 78 voltage VOLVO_CELL_V78
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 78 voltage VOLVO_ED_CELL_V78
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 79 voltage VOLVO_CELL_V79
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 79 voltage VOLVO_ED_CELL_V79
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 80 voltage VOLVO_CELL_V80
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 80 voltage VOLVO_ED_CELL_V80
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 81 voltage VOLVO_CELL_V81
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 81 voltage VOLVO_ED_CELL_V81
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 82 voltage VOLVO_CELL_V82
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 82 voltage VOLVO_ED_CELL_V82
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 83 voltage VOLVO_CELL_V83
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 83 voltage VOLVO_ED_CELL_V83
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 84 voltage VOLVO_CELL_V84
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 84 voltage VOLVO_ED_CELL_V84
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 85 voltage VOLVO_CELL_V85
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 85 voltage VOLVO_ED_CELL_V85
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 86 voltage VOLVO_CELL_V86
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 86 voltage VOLVO_ED_CELL_V86
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 87 voltage VOLVO_CELL_V87
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 87 voltage VOLVO_ED_CELL_V87
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 88 voltage VOLVO_CELL_V88
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 88 voltage VOLVO_ED_CELL_V88
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 89 voltage VOLVO_CELL_V89
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 89 voltage VOLVO_ED_CELL_V89
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 90 voltage VOLVO_CELL_V90
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 90 voltage VOLVO_ED_CELL_V90
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 91 voltage VOLVO_CELL_V91
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 91 voltage VOLVO_ED_CELL_V91
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 92 voltage VOLVO_CELL_V92
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 92 voltage VOLVO_ED_CELL_V92
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 93 voltage VOLVO_CELL_V93
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 93 voltage VOLVO_ED_CELL_V93
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1997 to 2016.
Cell 94 voltage VOLVO_CELL_V94
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 95 voltage VOLVO_CELL_V95
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.
Cell 96 voltage VOLVO_CELL_V96
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 1997 to 2016.