Fuel parameters
The Volvo V60 has 27 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Request
01 9E - Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2020. Supported for 2019.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Request
01 5E - Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3212.75 L/h
- Unit
- L/h
Confirmed for 2023. Supported for 2019 to 2022.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2020. Supported for 2019.
Fuel filter heater VOLVO_FUEL_FLT_HEATER
- Request
22 DC 14 - Service 22
DID DC14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Fuel filter heater VOLVO_FUEL_FLT_HEATER_7E0
- Request
22 DB 35 - Service 22
DID DB35 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Fuel heater fan adjustment VOLVO_FUEL_HEATER_FAN_ADJ
- Request
22 9A 03 - Service 22
DID 9A03 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2010 to 2026.
Fuel high pressure VOLVO_FUEL_HIGH_P
- Request
22 EE 4F - Service 22
DID EE4F - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000)- Range
- 0 to 32.76
- Unit
- Raw value
In testing for 2010 to 2026.
Fuel level 1 of 2 VOLVO_DIM_FLI_1_2
- Request
22 61 D1 - Service 22
DID 61D1 - Module
720 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 L
- Unit
- L
In testing for 2010 to 2026.
Fuel level 2 of 2 ejector side saddle tank VOLVO_DIM_FLI_2_2_EJECTOR
- Request
22 61 D0 - Service 22
DID 61D0 - Module
720 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 L
- Unit
- L
In testing for 2010 to 2026.
Fuel level damped VOLVO_DIM_FLI_DAMPED
- Request
22 EE 11 - Service 22
DID EE11 - Module
720 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 L
- Unit
- L
In testing for 2010 to 2026.
Fuel level damped VOLVO_FLI_DAMPED
- Request
22 EE 12 - Service 22
DID EE12 - Module
720 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 L
- Unit
- L
In testing for 2010 to 2026.
Fuel level input VOLVO_FLI_INPUT
Pelican can show this parameter as the fuel tank level.
- Request
22 F4 2F - Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Fuel level sensor VOLVO_FLI_SENS
- Request
22 41 17 - Service 22
DID 4117 - Module
726 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 20459)- Range
- 0 to 320 V
- Unit
- V
In testing for 2010 to 2026.
Fuel level sensor ejector side saddle tank VOLVO_FLI_SENS_EJECTOR
- Request
22 41 18 - Service 22
DID 4118 - Module
726 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 20459)- Range
- 0 to 320 V
- Unit
- V
In testing for 2010 to 2026.
Fuel low pressure VOLVO_FUEL_LOW_P
- Request
22 EE 57 - Service 22
DID EE57 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Fuel pressure VOLVO_FUEL_P
- Request
22 F4 23 - Service 22
DID F423 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100)- Range
- 0 to 6553500
- Unit
- Raw value
In testing for 2010 to 2026.
Fuel pressure VOLVO_FUEL_P_DA10
- Request
22 F4 0A - Service 22
DID F40A - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Fuel pressure nominal value VOLVO_FUEL_P_NOMINAL
- Request
22 D9 FF - Service 22
DID D9FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100)- Range
- 0 to 6553500
- Unit
- Raw value
In testing for 2010 to 2026.
Fuel pressure regulator valve current VOLVO_FUEL_P_REGULATOR_VLV
- Request
22 D9 EE - Service 22
DID D9EE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2010 to 2026.
Fuel pump low pressure side duty cycle VOLVO_FUEL_PMP_LOW_P_SIDE
- Request
22 EF 59 - Service 22
DID EF59 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2010 to 2026.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2020. Supported for 2019, 2021 to 2024.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2020. Supported for 2019, 2021 to 2024.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2015, 2020, 2023. Supported for 2019, 2021 to 2022, 2024.
Fuel temperature VOLVO_FUEL_T
- Request
22 D9 9C - Service 22
DID D99C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2026.
Fuel volume control valve VOLVO_FUEL_VOLUME_CTRL_VLV
- Request
22 DA D5 - Service 22
DID DAD5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2010 to 2026.
Fuel volume control valve VOLVO_FUEL_VOLUME_CTRL_VLV_7E0
- Request
22 DC 13 - Service 22
DID DC13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2010 to 2026.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2020. Supported for 2019.