Volvo S70

Engine parameters

The Volvo S70 has 255 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

- pedal position sensor VOLVO_PEDAL_POS_SENS

  • Request22 2B 35
  • Service 22DID 2B35
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 25)
Range
0 to 2621 mm
Unit
mm

In testing for 1996 to 2000.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

- pedal position sensor VOLVO_PEDAL_POS_SENS

  • Request22 2B 35
  • Service 22DID 2B35
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 25)
Range
0 to 2621 mm
Unit
mm

In testing for 1996 to 2000.

Accelerator pedal position VOLVO_M3_APP_ECM

  • Request22 F4 49
  • Service 22DID F449
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1996 to 2000.

Actual power VOLVO_ACT_POWER

  • Request22 4A 88
  • Service 22DID 4A88
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kW
Unit
kW

In testing for 1996 to 2000.

Adaptive cruise target vehicle VOLVO_ACC_TARGETVEHICLE

  • Request22 DA 12
  • Service 22DID DA12
  • Module720
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 1996 to 2000.

Adaptive cruise time gap VOLVO_ACC_TIMEGAP

  • Request22 DA 11
  • Service 22DID DA11
  • Module720
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 2 + 0.5)
Range
0 to 128 s
Unit
s

In testing for 1996 to 2000.

Air conditioning compressor module A current VOLVO_AC_COMP_MODULE

  • Request22 03 31
  • Service 22DID 0331
  • ModuleD016 → 1EC04E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 A
Unit
A

In testing for 1996 to 2000.

Air conditioning compressor module a status VOLVO_AC_COMP_MODULE_STAT

  • Request22 03 2F
  • Service 22DID 032F
  • ModuleD016 → 1EC04E80
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Air conditioning pressure VOLVO_AC_P

  • Request22 EE 34
  • Service 22DID EE34
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 2)
Range
-65536 to 65534 kPa
Unit
kPa

In testing for 1996 to 2000.

Air conditioning pressure VOLVO_AC_P_V2

  • Request22 D9 00
  • Service 22DID D900
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kPa
Unit
kPa

In testing for 1996 to 2000.

Air conditioning relay VOLVO_AC_RELAY

  • Request22 D9 09
  • Service 22DID D909
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Air distribution damper motor wanted position VOLVO_AIR_DISTRIBUTION

  • Request22 D9 04
  • Service 22DID D904
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 1996 to 2000.

Air distribution damper motor, actual position VOLVO_AIR_DISTRIBUTION_ACT

  • Request22 D9 09
  • Service 22DID D909
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 1996 to 2000.

Air flow/cycle, mg/s VOLVO_AIR_FLOW_CYCLE_MG_S

  • Request22 D9 16
  • Service 22DID D916
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Number

In testing for 1996 to 2000.

Air mass, desired VOLVO_AIR_MASS_DES

  • Request22 D9 1F
  • Service 22DID D91F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Raw value

In testing for 1996 to 2000.

Air quality sensor status VOLVO_AIR_QUALITY_SENS

  • Request22 DC F9
  • Service 22DID DCF9
  • Module733
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

All-wheel drive coupling current VOLVO_HALDEX_CURRENT

  • Request22 19 45
  • Service 22DID 1945
  • Module795
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

All-wheel drive coupling current VOLVO_HALDEX_CURRENT_795

  • Request22 19 46
  • Service 22DID 1946
  • Module795
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

All-wheel drive coupling module temperature sensor 1 VOLVO_HALDEX_ECU_T_SENS_1

  • Request22 D1 16
  • Service 22DID D116
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 1996 to 2000.

All-wheel drive coupling module temperature sensor 2 VOLVO_HALDEX_ECU_T_SENS_2

  • Request22 D9 00
  • Service 22DID D900
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 1996 to 2000.

All-wheel drive coupling oil temperature VOLVO_HALDEX_OIL_T

  • Request22 FD 04
  • Service 22DID FD04
  • Module795
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 60)
Range
-60 to 195 °C
Unit
°C

In testing for 1996 to 2000.

All-wheel drive coupling pressure VOLVO_HALDEX_P

  • Request22 19 44
  • Service 22DID 1944
  • Module795
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Raw value

In testing for 1996 to 2000.

All-wheel drive coupling rear axle torque VOLVO_HALDEX_REAR_AXLE_TQ

  • Request22 D9 30
  • Service 22DID D930
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1996 to 2000.

All-wheel drive coupling rear axle torque, requested VOLVO_HALDEX_REAR_AXLE_TQ_REQ

  • Request22 D9 53
  • Service 22DID D953
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1996 to 2000.

Alternator control mode VOLVO_ALTERNATOR_CTRL_MODE

  • Request22 40 D1
  • Service 22DID 40D1
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Alternator, amps VOLVO_ALTERNATOR_AMPS

  • Request22 D9 24
  • Service 22DID D924
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 A
Unit
A

In testing for 1996 to 2000.

Automatic alignment offset VOLVO_AUTOMATIC_ALIGNMENT

  • Request22 A2 20
  • Service 22DID A220
  • Module764
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 1996 to 2000.

Average charging time left VOLVO_AVG_CHG_TIME_LEFT

  • Request22 EE B6
  • Service 22DID EEB6
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 1996 to 2000.

Battery management sensor reliable VOLVO_BAT_MANAGEMENT_SENS

  • Request22 41 A7
  • Service 22DID 41A7
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Bonnet closed VOLVO_BONNET_CLOSED

  • Request22 C1 54
  • Service 22DID C154
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Boost air pressure after turbocharger VOLVO_BOOST_AIR_P_AFTER

  • Request22 03 3E
  • Service 22DID 033E
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 kPa
Unit
kPa

In testing for 1996 to 2000.

Boost air temperature VOLVO_BOOST_AIR_T

  • Request22 03 41
  • Service 22DID 0341
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 8 − 40)
Range
-40 to 119 °C
Unit
°C

In testing for 1996 to 2000.

Boost air temperature VOLVO_BOOST_AIR_T_7E0

  • Request22 03 41
  • Service 22DID 0341
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 8 − 40)
Range
-40 to 119 °C
Unit
°C

In testing for 1996 to 2000.

Boost pressure VOLVO_BOOST_P

  • Request22 D9 41
  • Service 22DID D941
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 kPa
Unit
kPa

In testing for 1996 to 2000.

Boost pressure, desired value VOLVO_BOOST_P_DES

  • Request22 D9 E4
  • Service 22DID D9E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 kPa
Unit
kPa

In testing for 1996 to 2000.

Boot lid sensor VOLVO_BOOT_LID_SENS

  • Request22 C1 50
  • Service 22DID C150
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 64)
Range
0 to 3.98
Unit
Number

In testing for 1996 to 2000.

Burning time, hours VOLVO_BURNING_TIME_HOURS

  • Request22 9A 0B
  • Service 22DID 9A0B
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1996 to 2000.

Burning time, minutes VOLVO_BURNING_TIME_MINUTES

  • Request22 9A 0B
  • Service 22DID 9A0B
  • Module7E3
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Calculated load VOLVO_CALC_LOAD

Pelican can show this parameter as the engine load.

  • Request22 F4 04
  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1996 to 2000.

Central lock VOLVO_CENTRAL_LOCK

  • Request22 C2 59
  • Service 22DID C259
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127
Unit
Number

In testing for 1996 to 2000.

Charging VOLVO_CHG_MS_CAN

  • Request22 D9 01
  • Service 22DID D901
  • Module791
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 1)
Range
-1 to 254
Unit
Number

In testing for 1996 to 2000.

Charging state VOLVO_CHG_ST

  • Request22 EE 1D
  • Service 22DID EE1D
  • ModuleD016 → 1EC68E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Cold zone count VOLVO_CEM_COLD_ZONE

  • Request22 D9 FE
  • Service 22DID D9FE
  • Module733
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Combustion air fan VOLVO_COMBUSTION_AIR_FAN

  • Request22 9A 06
  • Service 22DID 9A06
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Compressor inlet sensor pressure VOLVO_COMP_INLET_SENS_P

  • Request22 03 03
  • Service 22DID 0303
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 1996 to 2000.

Compressor inlet sensor temperature VOLVO_COMP_INLET_SENS_T

  • Request22 EE 36
  • Service 22DID EE36
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 1996 to 2000.

Compressor inlet sensor temperature VOLVO_COMP_INLET_SENS_T_D016

  • Request22 03 03
  • Service 22DID 0303
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100 − 40)
Range
-40 to 615 °C
Unit
°C

In testing for 1996 to 2000.

Compressor outlet sensor pressure VOLVO_COMP_OUTLET_SENS_P

  • Request22 03 29
  • Service 22DID 0329
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 1996 to 2000.

Compressor outlet sensor temperature VOLVO_COMP_OUTLET_SENS_T

  • Request22 EE 38
  • Service 22DID EE38
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 1996 to 2000.

Compressor outlet sensor temperature VOLVO_COMP_OUTLET_SENS_T_D016

  • Request22 03 29
  • Service 22DID 0329
  • ModuleD016 → 1EC04E80
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100 − 40)
Range
-40 to 615 °C
Unit
°C

In testing for 1996 to 2000.

Control module power supply VOLVO_CTRL_MODULE_POWER

  • Request22 D1 11
  • Service 22DID D111
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1996 to 2000.

Control module temperature VOLVO_CTRL_MODULE_T

  • Request22 D9 B8
  • Service 22DID D9B8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 8 − 40)
Range
-40 to 119 °C
Unit
°C

In testing for 1996 to 2000.

Coolant pump current VOLVO_ED_PUMP_A

  • Request22 23 09
  • Service 22DID 2309
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 A
Unit
A

In testing for 1996 to 2000.

Coolant pump relay VOLVO_CLT_PMP_RELAY

  • Request22 D9 5B
  • Service 22DID D95B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Coolant pump speed VOLVO_ED_PUMP_DUTY

  • Request22 D0 32
  • Service 22DID D032
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1996 to 2000.

Coolant pump temperature VOLVO_ED_PUMP_T

  • Request22 23 0A
  • Service 22DID 230A
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1996 to 2000.

Coolant pump voltage VOLVO_ED_PUMP_V

  • Request22 23 08
  • Service 22DID 2308
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1996 to 2000.

Coolant temperature VOLVO_ED_COOLANT_T

  • Request22 20 47
  • Service 22DID 2047
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8)
Range
0 to 8191.875 °C
Unit
°C

In testing for 1996 to 2000.

Cooling fan speed VOLVO_ED_FAN_DUTY

  • Request22 D0 41
  • Service 22DID D041
  • Module7E5 → 7ED
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1996 to 2000.

Counter VOLVO_CNT_MS_CAN

  • Request22 9A 0D
  • Service 22DID 9A0D
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Cylinder 1 misfire VOLVO_MIS_1

  • Request22 F6 A2
  • Service 22DID F6A2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Cylinder 1 misfire average VOLVO_MIS_AVG_1

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Cylinder 2 misfire VOLVO_MIS_2_V2

  • Request22 F6 A3
  • Service 22DID F6A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Cylinder 2 misfire average VOLVO_MIS_AVG_2

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Cylinder 3 misfire VOLVO_MIS_3_V2

  • Request22 F6 A4
  • Service 22DID F6A4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Cylinder 3 misfire average VOLVO_MIS_AVG_3

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Cylinder 4 misfire VOLVO_MIS_4

  • Request22 F6 A5
  • Service 22DID F6A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Cylinder 4 misfire average VOLVO_MIS_AVG_4

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Cylinder 5 misfire average VOLVO_MIS_AVG_5

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Cylinder 6 misfire average VOLVO_MIS_AVG_6

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Cylinder 7 misfire average VOLVO_MIS_AVG_7

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Cylinder 8 misfire average VOLVO_MIS_AVG_8

  • Request22 DA B6
  • Service 22DID DAB6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Days since last service VOLVO_DAYS_SINCE_SERVICE

  • Request22 D9 03
  • Service 22DID D903
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1996 to 2000.

Defroster damper motor wanted position VOLVO_DEFROSTER_DAMPER

  • Request22 D9 00
  • Service 22DID D900
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 1996 to 2000.

Defroster damper motor, actual position VOLVO_DEFROSTER_DAMPER_ACT

  • Request22 D9 05
  • Service 22DID D905
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 1996 to 2000.

Diesel particulate filter additive pump VOLVO_M3_ADM_ADDITIVE_PMP

  • Request22 D9 04
  • Service 22DID D904
  • Module7C0
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2000.

Diesel particulate filter pressure VOLVO_DPF_P

  • Request22 DA C8
  • Service 22DID DAC8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 1996 to 2000.

Diesel particulate filter soot VOLVO_DPF_SOOT

  • Request22 D9 F2
  • Service 22DID D9F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655
Unit
Raw value

In testing for 1996 to 2000.

Diesel particulate filter temperature VOLVO_DPF_T

  • Request22 D9 F9
  • Service 22DID D9F9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 1996 to 2000.

Dipped beam VOLVO_DIPPED_BEAM

  • Request22 71 51
  • Service 22DID 7151
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Display illumination intensity VOLVO_LCD_ILUMINATION

  • Request22 DB 01
  • Service 22DID DB01
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1996 to 2000.

Display temperature VOLVO_DISPLAY_T_MS_CAN

  • Request22 D9 06
  • Service 22DID D906
  • Module784
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Number

In testing for 1996 to 2000.

Distance to next service VOLVO_EQA_SERVICE_DIST

  • Request22 65 04
  • Service 22DID 6504
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 1996 to 2000.

Downtime VOLVO_DOWNTIME

  • Request22 EE D6
  • Service 22DID EED6
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5
Unit
Raw value

In testing for 1996 to 2000.

Electric drivetrain coolant temperature, IEM inlet VOLVO_ELEC_DRIVETRAIN_ECT

  • Request22 98 5E
  • Service 22DID 985E
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val − 40)
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 1996 to 2000.

Electric drivetrain coolant temperature, IEM outlet VOLVO_ELEC_DRIVETRAIN_ECT_IEM

  • Request22 98 5E
  • Service 22DID 985E
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
(val − 40)
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 1996 to 2000.

Electric drivetrain coolant temperature, IHFA inlet VOLVO_ELEC_DRIVETRAIN_ECT_IHFA

  • Request22 98 5E
  • Service 22DID 985E
  • ModuleD016 → 1ED24E80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val − 40)
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 1996 to 2000.

Electric drivetrain coolant temperature, IHFA outlet VOLVO_ELEC_DRIVETRAIN_ECT_IHFA_OUTLET

  • Request22 98 5E
  • Service 22DID 985E
  • ModuleD016 → 1ED24E80
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
(val − 40)
Range
-2147483688 to 2147483607 °C
Unit
°C

In testing for 1996 to 2000.

Electric front axle drive torque VOLVO_ELECTRICAL_FRONT

  • Request22 49 D4
  • Service 22DID 49D4
  • ModuleD016 → 1ED24E80
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val − 1024)
Range
-2147484672 to 2147482623 N·m
Unit
N·m

In testing for 1996 to 2000.

Electric rear axle drive calculated torque VOLVO_ERAD_CALC_TQ

  • Request22 EF 12
  • Service 22DID EF12
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 4 − 8188)
Range
-8188 to 253952 N·m
Unit
N·m

In testing for 1996 to 2000.

Electric rear axle drive motor winding temperature sensor 1 VOLVO_ERAD_MOTOR_WINDING_T_1

  • Request22 4A 00
  • Service 22DID 4A00
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364 °C
Unit
°C

In testing for 1996 to 2000.

Electric rear axle drive motor winding temperature sensor 2 VOLVO_ERAD_MOTOR_WINDING_T_2

  • Request22 4A 01
  • Service 22DID 4A01
  • ModuleD016 → 1EC6EE80
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364 °C
Unit
°C

In testing for 1996 to 2000.

Engine coolant fan VOLVO_ENG_CLT_FAN

  • Request22 EE 6F
  • Service 22DID EE6F
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 1996 to 2000.

Engine oil pressure VOLVO_EOP

  • Request22 EE 37
  • Service 22DID EE37
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 1996 to 2000.

Engine oil pressure VOLVO_EOP_V2

  • Request22 EF 4E
  • Service 22DID EF4E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 kPa
Unit
kPa

In testing for 1996 to 2000.

Engine oil temperature VOLVO_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 EE 58
  • Service 22DID EE58
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 1996 to 2000.

Engine oil temperature VOLVO_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 D9 DC
  • Service 22DID D9DC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 1996 to 2000.

Engine time since last service VOLVO_ENG_TIME_SINCE

  • Request22 63 0E
  • Service 22DID 630E
  • Module720
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1996 to 2000.

Engine torque VOLVO_ENG_TQ

  • Request22 DA 89
  • Service 22DID DA89
  • ModuleD016 → 1EC64E80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 512)
Range
-512 to 6041 N·m
Unit
N·m

In testing for 1996 to 2000.

ERAD calculated torque VOLVO_ERAD_CALC_TQ_D016

  • Request22 EE 09
  • Service 22DID EE09
  • ModuleD016 → 1EC6EE80
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 4 − 8188)
Range
-8188 to 253952 N·m
Unit
N·m

In testing for 1996 to 2000.

Evaporator temperature VOLVO_EVAPORATOR_T_MS_CAN

  • Request22 D9 98
  • Service 22DID D998
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 100)
Range
-100 to 923 °C
Unit
°C

In testing for 1996 to 2000.

Exhaust gas recirculation bypass valve VOLVO_EGR_BYPASS_VLV

  • Request22 EE 7F
  • Service 22DID EE7F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1996 to 2000.

Exhaust gas recirculation cooler bypass actuator position VOLVO_EGR_COOLER_BYPASS

  • Request22 DA D2
  • Service 22DID DAD2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 1996 to 2000.

Exhaust gas recirculation valve position sensor VOLVO_EGR_VLV_POS_SENS

  • Request22 DA AD
  • Service 22DID DAAD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 1996 to 2000.

Exhaust gas recirculation valve, commanded position VOLVO_EGR_VLV_CMD_POS

  • Request22 DC 01
  • Service 22DID DC01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 1996 to 2000.

Exhaust gas recirculation valve, commanded position II VOLVO_EGR_VLV_CMD_POS_II

  • Request22 D9 6D
  • Service 22DID D96D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 1996 to 2000.

Fan VOLVO_FAN

  • Request22 DC 02
  • Service 22DID DC02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 1996 to 2000.

Front axle sensor VOLVO_FRONT_AXLE_SENS

  • Request22 3B 71
  • Service 22DID 3B71
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.37 V
Unit
V

In testing for 1996 to 2000.

Front oxygen sensor heating VOLVO_FRONT_OXYGEN_SENS

  • Request22 DA 59
  • Service 22DID DA59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 ms
Unit
ms

In testing for 1996 to 2000.

Glow plug pulse ratio VOLVO_GLOW_PLUG_RAT_MS_CAN

  • Request22 9A 04
  • Service 22DID 9A04
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1996 to 2000.

Glow plugs VOLVO_GLOW_PLUGS

  • Request22 D9 A0
  • Service 22DID D9A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 1996 to 2000.

Grill shutter open VOLVO_GRILL_SHUTTER_OPEN

  • Request22 07 07
  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1996 to 2000.

High beam VOLVO_HIGH_BEAM

  • Request22 71 51
  • Service 22DID 7151
  • Module726
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

High voltage coolant heater A, inlet temperature VOLVO_HIGH_V_CLT_HEATER_T

  • Request22 03 2B
  • Service 22DID 032B
  • ModuleD016 → 1EC04E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 40)
Range
-40 to 615 °C
Unit
°C

In testing for 1996 to 2000.

High voltage coolant heater A, outlet temperature VOLVO_HIGH_V_CLT_HEATER_OUTLET_T

  • Request22 03 2B
  • Service 22DID 032B
  • ModuleD016 → 1EC04E80
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100 − 40)
Range
-40 to 615 °C
Unit
°C

In testing for 1996 to 2000.

High voltage ED coolant temperature 2 VOLVO_HIGH_V_ED_ECT_2

  • Request22 EF 73
  • Service 22DID EF73
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 1996 to 2000.

High voltage motor coolant pump VOLVO_HIGH_V_MOTOR_CLT_PMP

  • Request22 EF 71
  • Service 22DID EF71
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 rpm
Unit
rpm

In testing for 1996 to 2000.

High voltage system current VOLVO_HIGH_V_SYSTEM

  • Request22 EF 13
  • Service 22DID EF13
  • ModuleD016 → 1EC6EE80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 250)
Range
-250 to 260 A
Unit
A

In testing for 1996 to 2000.

High voltage system current VOLVO_HIGH_V_SYSTEM_CURRENT

  • Request22 98 61
  • Service 22DID 9861
  • ModuleD016 → 1ED24E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 + 40)
Range
-3236 to 3316 A
Unit
A

In testing for 1996 to 2000.

High voltage system current VOLVO_HIGH_V_SYSTEM_V2

  • Request22 98 61
  • Service 22DID 9861
  • ModuleD016 → 1EC6EE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 + 40)
Range
-3236 to 3316 A
Unit
A

In testing for 1996 to 2000.

Ignition angle before top dead center VOLVO_IGN_ANG_BTDC

  • Request22 F4 0E
  • Service 22DID F40E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5
Unit
Number

In testing for 1996 to 2000.

In car temperature VOLVO_CAR_T

  • Request22 DD 04
  • Service 22DID DD04
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2000.

In car temperature VOLVO_CAR_T_MS_CAN_7E3

  • Request22 DD 04
  • Service 22DID DD04
  • Module7E3
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2000.

In-car temperature VOLVO_CAR_T_720

  • Request22 DD 04
  • Service 22DID DD04
  • Module720
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2000.

In-car temperature VOLVO_CAR_T_MS_CAN

  • Request22 9A 1B
  • Service 22DID 9A1B
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 100)
Range
-100 to 923 °C
Unit
°C

In testing for 1996 to 2000.

Infotainment ring optical fiber test VOLVO_MOST_OPTICAL_FIBRE

  • Request22 83 1F
  • Service 22DID 831F
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Input torque calculated VOLVO_INPUT_TQ_CALC

  • Request22 D9 62
  • Service 22DID D962
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 8 − 16376)
Range
-16376 to 507904 N·m
Unit
N·m

In testing for 1996 to 2000.

Input torque, requested VOLVO_INPUT_TQ_REQ

  • Request22 D9 56
  • Service 22DID D956
  • Module795
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 8 − 16376)
Range
-16376 to 507904 N·m
Unit
N·m

In testing for 1996 to 2000.

Intake air temperature, manifold sensor VOLVO_TMAP_IAT

  • Request22 D9 AB
  • Service 22DID D9AB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.14)
Range
-3549 to 3003 °C
Unit
°C

In testing for 1996 to 2000.

Lateral angle VOLVO_LATERAL_ANG

  • Request22 2B 0C
  • Service 22DID 2B0C
  • Module760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °
Unit
°

In testing for 1996 to 2000.

Leading A/T VOLVO_LEADING_T

  • Request22 1E 2F
  • Service 22DID 1E2F
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1996 to 2000.

Left seat heater VOLVO_LEFT_SEAT_HEATER_MS

  • Request22 9A 21
  • Service 22DID 9A21
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1996 to 2000.

Left temperature damper motor wanted position VOLVO_LEFT_T_DAMPER_MOTOR

  • Request22 D9 02
  • Service 22DID D902
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 1996 to 2000.

Left temperature damper motor, actual position VOLVO_LEFT_T_DAMPER_MOTOR_ACT

  • Request22 D9 07
  • Service 22DID D907
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 1996 to 2000.

Load VOLVO_LOAD

  • Request22 F4 43
  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 25700 %
Unit
%

In testing for 1996 to 2000.

M3 APP, CAN VOLVO_M3_APP_CAN

  • Request22 F4 4A
  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1996 to 2000.

M3 diff.press. VOLVO_M3_DIFF_PRESS

  • Request22 D9 F3
  • Service 22DID D9F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1996 to 2000.

M3 DPF soot VOLVO_M3_DPF_SOOT

  • Request22 D9 F2
  • Service 22DID D9F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.55 g
Unit
g

In testing for 1996 to 2000.

M3 EGR DC VOLVO_M3_EGR_DC

  • Request22 D9 6C
  • Service 22DID D96C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 1996 to 2000.

M3 IAT, butterfly VOLVO_M3_IAT_BUTTERFLY

  • Request22 F4 0F
  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2000.

M3 IAT, MAF VOLVO_M3_IAT_MAF

  • Request22 D9 1C
  • Service 22DID D91C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 °C
Unit
°C

In testing for 1996 to 2000.

Misfire catalytic damage total - petrol VOLVO_MIS_CATALYTIC_DAMAGE

  • Request22 DA 03
  • Service 22DID DA03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Misfires, cylinder 2 VOLVO_MIS_2

  • Request22 EF 71
  • Service 22DID EF71
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Misfires, cylinder 3 VOLVO_MIS_3

  • Request22 EF 71
  • Service 22DID EF71
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Module current VOLVO_MODULE_CURRENT

  • Request22 19 46
  • Service 22DID 1946
  • ModuleD016 → 1EC70E80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Months since last service VOLVO_MONTHS_SINCE_SERVICE

  • Request22 63 0E
  • Service 22DID 630E
  • Module720
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 120)
Range
0 to 546
Unit
Number

In testing for 1996 to 2000.

MOST lock VOLVO_MOST_LOCK_MS_CAN

  • Request22 DB 16
  • Service 22DID DB16
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

MOST network number of modules VOLVO_MOST_NETWORK_NUM

  • Request22 83 35
  • Service 22DID 8335
  • Module784
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Motor hours since last service VOLVO_MOTOR_HOURS_SINCE

  • Request22 D9 03
  • Service 22DID D903
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 1996 to 2000.

Navigation altitude VOLVO_SENSUS_CONNECT_GPS

  • Request22 80 12
  • Service 22DID 8012
  • Module784
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 180)
Range
0 to 364 °
Unit
°

In testing for 1996 to 2000.

Navigation fix VOLVO_SENSUS_CONNECT_GPS_FIX_MS

  • Request22 80 12
  • Service 22DID 8012
  • Module784
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 1996 to 2000.

Navigation heading VOLVO_SENSUS_CONNECT_GPS_HEADING

  • Request22 80 12
  • Service 22DID 8012
  • Module784
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 1996 to 2000.

Navigation number of satellites VOLVO_SENSUS_CONNECT_GPS_NUM

  • Request22 80 35
  • Service 22DID 8035
  • Module784
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

On-board charger module temperature VOLVO_OBC_T

  • Request22 EE 19
  • Service 22DID EE19
  • ModuleD016 → 1EC68E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 1996 to 2000.

Operating state VOLVO_OP_ST_MS_CAN

  • Request22 9A 08
  • Service 22DID 9A08
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Outdoor temperature, BCM VOLVO_OUTDOOR_T_BCM

  • Request22 DD 05
  • Service 22DID DD05
  • Module760
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2000.

Outside heat exchanger outlet sensor pressure VOLVO_OUTSIDE_HEAT_P

  • Request22 EE 48
  • Service 22DID EE48
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val
Range
-2147483648 to 2147483647
Unit
Raw value

In testing for 1996 to 2000.

Outside heat exchanger outlet sensor temperature VOLVO_OUTSIDE_HEAT_T

  • Request22 EE 47
  • Service 22DID EE47
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 1996 to 2000.

Parking heater counter VOLVO_PARKING_HEATER_CNT

  • Request22 9A 0E
  • Service 22DID 9A0E
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Parking lights VOLVO_PARKING_LIGHTS

  • Request22 71 51
  • Service 22DID 7151
  • Module726
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Passenger airbag activated VOLVO_PASSENGER_AIRBAG_ACTIVATED

  • Request22 5B 29
  • Service 22DID 5B29
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Passenger airbag cutoff switch VOLVO_PASSENGER_AIRBAG

  • Request22 5B 28
  • Service 22DID 5B28
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127
Unit
Number

In testing for 1996 to 2000.

Passenger airbag OFF lamp VOLVO_PASSENGER_AIRBAG_OFF

  • Request22 61 A5
  • Service 22DID 61A5
  • Module737
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 32)
Range
0 to 7.96
Unit
Number

In testing for 1996 to 2000.

Power mode VOLVO_POWER_MODE

  • Request22 DD 06
  • Service 22DID DD06
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 192)
Range
-192 to 63
Unit
Number

In testing for 1996 to 2000.

Power mode VOLVO_POWER_MODE_MS_CAN

  • Request22 DD 07
  • Service 22DID DD07
  • Module784
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 99)
Range
-99 to 156
Unit
Number

In testing for 1996 to 2000.

Power mode VOLVO_POWER_MODE_MS_CAN_7E3

  • Request22 DD 06
  • Service 22DID DD06
  • Module7E3
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Quiescent current average VOLVO_QUIESCENT_CURRENT

  • Request22 40 25
  • Service 22DID 4025
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 1000)
Range
-1000 to 31767 mA
Unit
mA

In testing for 1996 to 2000.

Rear axle sensor VOLVO_REAR_AXLE_SENS

  • Request22 3B 73
  • Service 22DID 3B73
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.37 V
Unit
V

In testing for 1996 to 2000.

Rear defroster automatic VOLVO_REAR_DEFROSTER

  • Request22 D9 18
  • Service 22DID D918
  • Module733
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Rear left seat heater VOLVO_RL_SEAT_HEATER_MS

  • Request22 9A 23
  • Service 22DID 9A23
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1996 to 2000.

Rear oxygen sensor heating VOLVO_REAR_OXYGEN_SENS

  • Request22 DB 77
  • Service 22DID DB77
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 ms
Unit
ms

In testing for 1996 to 2000.

Rear right seat heater VOLVO_RR_SEAT_HEATER_MS

  • Request22 9A 24
  • Service 22DID 9A24
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1996 to 2000.

Recirculation damper motor wanted position VOLVO_RECIRCULATION_DAMPER

  • Request22 D9 01
  • Service 22DID D901
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 1996 to 2000.

Recirculation damper motor, actual position VOLVO_RECIRCULATION_DAMPER_ACT

  • Request22 D9 06
  • Service 22DID D906
  • Module733
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 1996 to 2000.

Remote key VOLVO_REMOTE_KEY

  • Request22 41 2D
  • Service 22DID 412D
  • Module726
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Right seat heater VOLVO_RIGHT_SEAT_HEATER_MS

  • Request22 9A 22
  • Service 22DID 9A22
  • Module733
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 1996 to 2000.

Right temperature damper motor wanted position VOLVO_RIGHT_T_DAMPER_MOTOR

  • Request22 D9 03
  • Service 22DID D903
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 1996 to 2000.

Right temperature damper motor, actual position VOLVO_RIGHT_T_DAMPER_MOTOR_ACT

  • Request22 D9 08
  • Service 22DID D908
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 1996 to 2000.

Running time, hours VOLVO_RUNNING_TIME_HOURS

  • Request22 9A 0C
  • Service 22DID 9A0C
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1996 to 2000.

Running time, minutes VOLVO_RUNNING_TIME_MINUTES

  • Request22 9A 0C
  • Service 22DID 9A0C
  • Module7E3
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Seat buckle driver locked VOLVO_SEAT_BUCKLE_DRIVER

  • Request22 5B 19
  • Service 22DID 5B19
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127
Unit
Number

In testing for 1996 to 2000.

Seat buckle passenger locked VOLVO_SEAT_BUCKLE

  • Request22 5B 1A
  • Service 22DID 5B1A
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127
Unit
Number

In testing for 1996 to 2000.

Seat buckle rear center locked VOLVO_SEAT_BUCKLE_REAR

  • Request22 5B 47
  • Service 22DID 5B47
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Seat buckle rear left locked VOLVO_SEAT_BUCKLE_RL

  • Request22 5B 46
  • Service 22DID 5B46
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Seat buckle rear right locked VOLVO_SEAT_BUCKLE_RR

  • Request22 5B 48
  • Service 22DID 5B48
  • Module737
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Servo control module temperature VOLVO_SERVO_CTRL_MODULE_T

  • Request22 D1 1C
  • Service 22DID D11C
  • Module730
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2000.

Servo pump engine power consumption VOLVO_SERVO_PMP_ENG_POWER

  • Request22 41 39
  • Service 22DID 4139
  • Module730
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 A
Unit
A

In testing for 1996 to 2000.

Slave A/T VOLVO_SLAVE_T

  • Request22 1E 1B
  • Service 22DID 1E1B
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1996 to 2000.

SLC1 current VOLVO_SLC1_CURRENT

  • Request22 D9 0C
  • Service 22DID D90C
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

SLC2 current VOLVO_SLC2_CURRENT

  • Request22 D9 0F
  • Service 22DID D90F
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

SLC3 current VOLVO_SLC3_CURRENT

  • Request22 D9 10
  • Service 22DID D910
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Starter relay VOLVO_STARTER_RELAY

  • Request22 D9 50
  • Service 22DID D950
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Starter relay 1 VOLVO_STARTER_RELAY_1

  • Request22 DA 12
  • Service 22DID DA12
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Starter relay 2 VOLVO_STARTER_RELAY_2

  • Request22 EE EB
  • Service 22DID EEEB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Steering angle, actual value VOLVO_STEER_ANG_ACT

  • Request22 33 02
  • Service 22DID 3302
  • Module760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Raw value

In testing for 1996 to 2000.

Steering shaft torque VOLVO_STEER_SHFT_TQ

  • Request22 33 0C
  • Service 22DID 330C
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10 − 12.7)
Range
-12.7 to 12.8 N·m
Unit
N·m

In testing for 1996 to 2000.

Supplementary heater counter VOLVO_SUPPLEMENTARY_HEATER

  • Request22 9A 0F
  • Service 22DID 9A0F
  • Module7E3
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

System relay VOLVO_SYSTEM_RELAY

  • Request22 D9 4F
  • Service 22DID D94F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Tailgate closing motor VOLVO_TAILGATE_CLOSING

  • Request22 D9 08
  • Service 22DID D908
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Tailgate hall sensor signal VOLVO_TAILGATE_HALL_SENS

  • Request22 D9 04
  • Service 22DID D904
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Tailgate handle button VOLVO_TAILGATE_HANDLE

  • Request22 D9 00
  • Service 22DID D900
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Tailgate motor protection VOLVO_TAILGATE_MOTOR

  • Request22 EE 04
  • Service 22DID EE04
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Tailgate opening motor VOLVO_TAILGATE_OPENING

  • Request22 D9 07
  • Service 22DID D907
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Tailgate opening position VOLVO_TAILGATE_OPENING_POS

  • Request22 D9 09
  • Service 22DID D909
  • Module775
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1996 to 2000.

Tailgate power supply VOLVO_TAILGATE_POWER_SUP

  • Request22 D1 11
  • Service 22DID D111
  • Module775
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1996 to 2000.

Tailgate switch 1-2 VOLVO_TAILGATE_SWITCH_1_2

  • Request22 D9 01
  • Service 22DID D901
  • Module775
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Temperature left setting VOLVO_T_LEFT_SETTING_MS

  • Request22 D9 30
  • Service 22DID D930
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 °C
Unit
°C

In testing for 1996 to 2000.

Temperature right setting VOLVO_T_RIGHT_SETTING_MS

  • Request22 D9 31
  • Service 22DID D931
  • Module733
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 °C
Unit
°C

In testing for 1996 to 2000.

Throttle absolute position VOLVO_THROTTLE_ABS_POS

Pelican can show this parameter as the throttle position.

  • Request22 F4 11
  • Service 22DID F411
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1996 to 2000.

Time since engine start VOLVO_TIME_SINCE_ENG_START

  • Request22 F4 1F
  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 1996 to 2000.

Torque converter lock-up solenoid VOLVO_LOCK_UP_SOLENOID_SLU_7E1

  • Request22 DA 4C
  • Service 22DID DA4C
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Torque converter lock-up solenoid current VOLVO_LOCK_UP_SOLENOID_SLU_CURRENT

  • Request22 1E 47
  • Service 22DID 1E47
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Torque converter lock-up solenoid current, requested VOLVO_LOCK_UP_SOLENOID_SLU

  • Request22 1E 41
  • Service 22DID 1E41
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Torque converter lock-up solenoid, requested VOLVO_LOCK_UP_SOLENOID_SLU_REQ

  • Request22 DA 4B
  • Service 22DID DA4B
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Torque from engine VOLVO_TQ_ENG

  • Request22 E5 01
  • Service 22DID E501
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1996 to 2000.

Total engine running time at last service VOLVO_TOT_ENG_RUNNING_TIME

  • Request22 61 CC
  • Service 22DID 61CC
  • Module720
  • Every30 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 1996 to 2000.

Total months at last service VOLVO_TOT_MONTHS_LAST

  • Request22 61 CC
  • Service 22DID 61CC
  • Module720
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val × 6)
Range
0 to 393210
Unit
Raw value

In testing for 1996 to 2000.

Traction control switch indicator VOLVO_DTSC_SWITCH

  • Request22 2B 05
  • Service 22DID 2B05
  • Module760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 64 − 1)
Range
-1 to 2.98
Unit
Number

In testing for 1996 to 2000.

Transmission fixed lock-up VOLVO_FIXED_LOCK_UP

  • Request22 1E 24
  • Service 22DID 1E24
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Transmission kickdown VOLVO_KICKDOWN

  • Request22 DC E4
  • Service 22DID DCE4
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Transmission line pressure solenoid current VOLVO_LINEAR_P_SOLENOID_SLT

  • Request22 1E 40
  • Service 22DID 1E40
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission line pressure solenoid current VOLVO_LINEAR_P_SOLENOID_SLT_CURRENT

  • Request22 DA 4A
  • Service 22DID DA4A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission line pressure solenoid current, requested VOLVO_LINEAR_P_SOLENOID

  • Request22 1E 1E
  • Service 22DID 1E1E
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission line pressure solenoid current, requested VOLVO_LINEAR_P_SOLENOID_SLT_REQ

  • Request22 DA 49
  • Service 22DID DA49
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SL1 current VOLVO_LINEAR_P_SOLENOID_SL1

  • Request22 DA 4E
  • Service 22DID DA4E
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SL1, requested, current VOLVO_LINEAR_P_SOLENOID_SL1_REQ

  • Request22 DA 4D
  • Service 22DID DA4D
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SL2 current VOLVO_LINEAR_P_SOLENOID_SL2

  • Request22 DA 50
  • Service 22DID DA50
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SL2, requested, current VOLVO_LINEAR_P_SOLENOID_SL2_REQ

  • Request22 DA 4F
  • Service 22DID DA4F
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SL3 current VOLVO_LINEAR_P_SOLENOID_SL3

  • Request22 DA 52
  • Service 22DID DA52
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SL3, requested, current VOLVO_LINEAR_P_SOLENOID_SL3_REQ

  • Request22 DA 51
  • Service 22DID DA51
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SLB1, requested, current VOLVO_LINEAR_P_SOLENOID_SLB1_REQ

  • Request22 1E 45
  • Service 22DID 1E45
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SLC1 current VOLVO_LINEAR_P_SOLENOID_SLC1

  • Request22 1E 48
  • Service 22DID 1E48
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SLC1, requested, current VOLVO_LINEAR_P_SOLENOID_SLC1_REQ

  • Request22 1E 42
  • Service 22DID 1E42
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SLC2 current VOLVO_LINEAR_P_SOLENOID_SLC2

  • Request22 1E 49
  • Service 22DID 1E49
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SLC2, requested, current VOLVO_LINEAR_P_SOLENOID_SLC2_REQ

  • Request22 1E 43
  • Service 22DID 1E43
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SLC3 current VOLVO_LINEAR_P_SOLENOID_SLC3

  • Request22 1E 4A
  • Service 22DID 1E4A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission linear pressure solenoid SLC3, requested, current VOLVO_LINEAR_P_SOLENOID_SLC3_REQ

  • Request22 1E 44
  • Service 22DID 1E44
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1996 to 2000.

Transmission lock-up function VOLVO_LOCK_UP_FUNCTION

  • Request22 DA 3C
  • Service 22DID DA3C
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 3 − 0.333333)
Range
-0.333 to 84.66
Unit
Number

In testing for 1996 to 2000.

Transmission selector VOLVO_SELECTOR

  • Request22 DC EA
  • Service 22DID DCEA
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127
Unit
Number

In testing for 1996 to 2000.

Transmission solenoid S1 status VOLVO_SOLENOID_S1_STAT

  • Request22 DD 89
  • Service 22DID DD89
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Transmission solenoid S2 status VOLVO_SOLENOID_S2_STAT

  • Request22 DD 8A
  • Service 22DID DD8A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1996 to 2000.

Transmission start lock - start approved VOLVO_START_LOCK_START

  • Request22 DF 08
  • Service 22DID DF08
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 255)
Range
0 to 1
Unit
Number

In testing for 1996 to 2000.

Transmission torque VOLVO_TQ

  • Request22 DD 8D
  • Service 22DID DD8D
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 1996 to 2000.

Transmission torque limiting VOLVO_TQ_LIMITING

  • Request22 DC F0
  • Service 22DID DCF0
  • Module7E1
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 N·m
Unit
N·m

In testing for 1996 to 2000.

Trip 1 VOLVO_TRIP_1

  • Request22 D9 36
  • Service 22DID D936
  • Module720
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 km
Unit
km

In testing for 1996 to 2000.

Trip 2 VOLVO_TRIP_2

  • Request22 D9 37
  • Service 22DID D937
  • Module720
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 km
Unit
km

In testing for 1996 to 2000.

Turbo bypass valve opened VOLVO_TURBO_BYPASS_VLV

  • Request22 D9 EE
  • Service 22DID D9EE
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1996 to 2000.

Turbo control valve wastegate VOLVO_TURBO_CTRL_VLV_WASTEGATE

  • Request22 DC 10
  • Service 22DID DC10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 8191)
Range
0 to 800 %
Unit
%

In testing for 1996 to 2000.

Turbo control valve, bypass or variable nozzle VOLVO_TURBO_CTRL_VLV

  • Request22 DC 00
  • Service 22DID DC00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 8191)
Range
0 to 800 %
Unit
%

In testing for 1996 to 2000.

Twilight sensor VOLVO_TWILIGHT_SENS

  • Request22 41 2A
  • Service 22DID 412A
  • Module726
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 1996 to 2000.

Wastegate position VOLVO_WASTEGATE_POS

  • Request22 DC 80
  • Service 22DID DC80
  • ModuleD016 → 1EC60E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1996 to 2000.

Water cooled condenser outlet sensor temperature VOLVO_WATER_COOLED_T

  • Request22 EE 40
  • Service 22DID EE40
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 1996 to 2000.

Water temperature VOLVO_WATER_T_MS_CAN

  • Request22 F4 05
  • Service 22DID F405
  • Module7E3
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1996 to 2000.

Yaw rate sensor offset VOLVO_YAW_RATE_SENS_OFFSET

  • Request22 EE 03
  • Service 22DID EE03
  • Module760
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 3500)
Range
0 to 18.72
Unit
Raw value

In testing for 1996 to 2000.

Yaw rate signal VOLVO_YAW_RATE_SIG

  • Request22 2B 0B
  • Service 22DID 2B0B
  • Module760
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5)
Range
-6553 to 6553
Unit
Raw value

In testing for 1996 to 2000.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc