Toyota Venza Hybrid

Connectable parameters

The Toyota Venza Hybrid has 6 Connectables, parameters that Pelican can monitor automatically.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

State of charge VENZAHYBRID_SOC

Pelican can show this parameter as the state of charge.

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module7D2
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

State of charge

State of charge VENZAHYBRID_SOC

Pelican can show this parameter as the state of charge.

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module7D2
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Fuel tank level

Fuel remaining VENZAHYBRID_FLV

Pelican can show this parameter as the fuel tank level.

  • Request22 10 22
  • Service 22DID 1022
  • Module7C0
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 L
Unit
L

Front left tire pressure

Front left tire pressure VENZAHYBRID_TP_2

Pelican can show this parameter as the front left tire pressure.

  • Request22 10 05
  • Service 22DID 1005
  • Module750 → 758
  • Every5 s

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 4.125 − 5.6969697)
Range
0 to 56.8 psi
Unit
psi

Front right tire pressure

Front right tire pressure VENZAHYBRID_TP_1

Pelican can show this parameter as the front right tire pressure.

  • Request22 10 05
  • Service 22DID 1005
  • Module750 → 758
  • Every5 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 4.125 − 5.6969697)
Range
0 to 56.8 psi
Unit
psi

Rear left tire pressure

Rear left tire pressure VENZAHYBRID_TP_4

Pelican can show this parameter as the rear left tire pressure.

  • Request22 10 05
  • Service 22DID 1005
  • Module750 → 758
  • Every5 s

Bits 56 to 63 of the reply, 8 bits.

Formula
(val ÷ 4.125 − 5.6969697)
Range
0 to 56.8 psi
Unit
psi

Rear right tire pressure

Rear right tire pressure VENZAHYBRID_TP_3

Pelican can show this parameter as the rear right tire pressure.

  • Request22 10 05
  • Service 22DID 1005
  • Module750 → 758
  • Every5 s

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 4.125 − 5.6969697)
Range
0 to 56.8 psi
Unit
psi

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.