Boosting converter temperature, lower SIENNA_BOOSTING_CONV_T_LO
- Request
22 10 A7 - Service 22
DID 10A7 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Boosting converter temperature, upper SIENNA_BOOSTING_CONV_T_HI
- Request
22 10 A7 - Service 22
DID 10A7 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2026.
Current gear SIENNA_GEAR_V2
- Request
21 DA - Service 21
PID DA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2011, 2015 to 2016, 2019, 2021 to 2023, 2025 to 2026. Not supported for 2012 to 2014, 2017 to 2018, 2020, 2024.
DC-DC converter output current SIENNA_DC_DC_CONV_OUTPUT
- Request
22 11 1C - Service 22
DID 111C - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25 ÷ 32)- Range
- 0 to 199 A
- Unit
- A
In testing for 2022 to 2026.
Gear SIENNA_GEAR
- Request
21 85 - Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 20
- Unit
- Number
In testing for 1998 to 2010, 2015 to 2016, 2021, 2023, 2025 to 2026. Not supported for 2011 to 2014, 2017 to 2020, 2022, 2024.
Gear SIENNA_GEAR_700Confirmed
- Request
22 16 21 - Service 22
DID 1621 - Module
700 → 708 - Every
1 s - Testing for 1998 to 2016, 2019, 2021 to 2026
Example reply from a 2020 Toyota Sienna.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017 to 2018, 2020. In testing for 1998 to 2011, 2015 to 2016, 2019, 2021 to 2023, 2025 to 2026. Not supported for 2012 to 2014, 2024.
Lock up state SIENNA_AT_LOCK_UP_STATEConfirmed
- Request
22 16 20 - Service 22
DID 1620 - Module
700 → 708 - Every
1 s - Testing for 1998 to 2016, 2019, 2021 to 2026
Example reply from a 2020 Toyota Sienna.
Bit 7 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017 to 2018, 2020. In testing for 1998 to 2011, 2015 to 2016, 2019, 2021 to 2023, 2025 to 2026. Not supported for 2012 to 2014, 2024.
Torque converter and TE1 on SIENNA_TQ_CONV_TE1_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1998 to 2026.
Torque converter lock-up SIENNA_TQC_LOCKUP
Engages a clutch inside the torque converter to create a direct connection between the engine and transmission, reducing slippage and improving efficiency.
- Request
21 85 - Service 21
PID 85 - Module
7E0 → 7E8 - Every
400 ms - Testing
Bit 8 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2010, 2015 to 2016, 2021, 2023, 2025 to 2026. Not supported for 2011 to 2014, 2017 to 2020, 2022, 2024.
Transmission fluid post-converter temperature, variant 3 SIENNA_TRANS_FLUID_POST_T_3
- Request
22 16 28 - Service 22
DID 1628 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1998 to 2016, 2019 to 2026. Not supported for 2017 to 2018.
Transmission fluid temperature, pan var.3 SIENNA_ATF_T_PAN_V3Confirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 16 27 - Service 22
DID 1627 - Module
700 → 708 - Every
5 s - Testing for 1998 to 2016, 2019, 2021 to 2026
Example reply from a 2020 Toyota Sienna.
Bits 0 to 15 of the reply, 16 bits.
0x50A0 = 20640 → (20640 ÷ 256 − 40) = 40.625 °C
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017 to 2018, 2020. In testing for 1998 to 2011, 2015 to 2016, 2019, 2021 to 2023, 2025 to 2026. Not supported for 2012 to 2014, 2024.
Transmission fluid temperature, variant 5 SIENNA_ATF_T_V_5
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1998 to 2026.
Transmission fluid temperature, variant 8 SIENNA_ATF_T_V_8
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1998 to 2026.
Transmission fluid temperature, variant 14 SIENNA_ATF_T_V_14
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 1998 to 2026.
Transmission fluid temperature, variant 21 SIENNA_ATF_T_V_21
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2026.
Transmission oil pressure calibration, complete SIENNA_TRANS_OIL_PRESS
- Request
21 83 - Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1998 to 2026.
Transmission shift state ratio SIENNA_TRANS_SHIFT_ST_RAT
- Request
22 16 22 - Service 22
DID 1622 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5333 ÷ 21845000)- Range
- 0 to 15.999
- Unit
- Number
In testing for 1998 to 2016, 2019 to 2026. Not supported for 2017 to 2018.
Transmission shift state ratio SIENNA_TRANS_SHIFT_ST_RAT_701
- Request
22 16 22 - Service 22
DID 1622 - Module
701 → 709 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5333 ÷ 21845000)- Range
- 0 to 15.999
- Unit
- Number
In testing for 1998 to 2016, 2019 to 2026. Not supported for 2017 to 2018.
Transmission temperature, pan SIENNA_ATF_PAN_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 82 - Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2010, 2015 to 2016, 2021, 2023, 2025 to 2026. Not supported for 2011 to 2014, 2017 to 2020, 2022, 2024.
Transmission temperature, torque converter SIENNA_ATF_TQC_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 82 - Service 21
PID 82 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2010, 2015 to 2016, 2021, 2023, 2025 to 2026. Not supported for 2011 to 2014, 2017 to 2020, 2022, 2024.