Toyota Land Cruiser Hybrid

Climate parameters

The Toyota Land Cruiser Hybrid has 19 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Ambient temperature LCH_AMBIENT_TConfirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every1 s
  • Testing for 2015 to 2024, 2026

Example reply from a 2025 Toyota Land Cruiser Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x3C = 60 → (60 − 40) = 20 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. In testing for 2015 to 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Adjusted ambient temperature LCH_ADJUSTED_AMBIENT_T

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

In testing for 2015 to 2024, 2026. Not supported for 2025.

Air conditioning inverter gate LCH_AC_GATE

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 67 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2024, 2026. Not supported for 2025.

Air conditioning power consumption LCH_AC_PWR

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 kW
Unit
kW

In testing for 2015 to 2024, 2026. Not supported for 2025.

Air conditioning requested LCH_AC_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2024, 2026. Not supported for 2025.

Air inlet damper actual pulse LCH_AIR_INLET_DAMPER_ACTUAL_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2024, 2026. Not supported for 2025.

Air inlet damper target pulse LCH_AIR_INLET_DAMPER_TARGET_PULSE

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2024, 2026. Not supported for 2025.

Air outlet servo actual pulse, driver LCH_AIR_OUTLET_SERVO_ACTU_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2024, 2026. Not supported for 2025.

Air outlet servo pulse, driver LCH_AIR_OUTLET_SERVO_PULSE_D

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2024, 2026. Not supported for 2025.

Ambient air temperature LCH_AAT_7C4

  • Request21 22
  • Service 21PID 22
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 23.3)
Range
-23.3 to 65.95 °C
Unit
°C

In testing for 2015 to 2024, 2026. Not supported for 2025.

Ambient temperature LCH_AMBIENT_TConfirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every1 s
  • Testing for 2015 to 2024, 2026

Example reply from a 2025 Toyota Land Cruiser Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x3C = 60 → (60 − 40) = 20 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. In testing for 2015 to 2024, 2026.

Blower motor speed level LCH_BLOWER_MOTOR_SPEED_LEVEL

  • Request21 3C
  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2024, 2026. Not supported for 2025.

Cabin temperature LCH_CABIN_T

  • Request21 21
  • Service 21PID 21
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 63.75 ÷ 255 − 6.5)
Range
-6.5 to 57.25 °C
Unit
°C

In testing for 2015 to 2024, 2026. Not supported for 2025.

Climate control engine run requested LCH_HVAC_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2024, 2026. Not supported for 2025.

Communication with air conditioner LCH_COMM_WITH_AIR_CONDITIONER

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2024, 2026. Not supported for 2025.

Communication with HV LCH_COMMUNICATION_WITH_HV

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2024, 2026. Not supported for 2025.

Communication with valvematic LCH_COMM_WITH_VALVEMATIC_COMM

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2015 to 2024, 2026. Not supported for 2025.

Evaporator fin thermistor LCH_EVAP_FIN_THERMISTOR

  • Request21 4B
  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 − 29.7)
Range
-29.7 to 59.55 °C
Unit
°C

In testing for 2015 to 2024, 2026. Not supported for 2025.

Set temperature, driver side LCH_T_DRIVER

  • Request21 29
  • Service 21PID 29
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2015 to 2024, 2026. Not supported for 2025.

Solar sensor, driver side LCH_SOLAR_DRIVER

  • Request21 24
  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2024, 2026. Not supported for 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.