Toyota Innova

Electrical parameters

The Toyota Innova has 6 electrical parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery charge, total TOYOTA_12V_AH_IN

  • Request22 15 E8
  • Service 22DID 15E8
  • Module7D2 → 7DA
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2004 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery charge, total TOYOTA_12V_AH_IN

  • Request22 15 E8
  • Service 22DID 15E8
  • Module7D2 → 7DA
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2004 to 2026.

12V battery discharge, total TOYOTA_12V_AH_OUT

  • Request22 15 E8
  • Service 22DID 15E8
  • Module7D2 → 7DA
  • Every60 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2004 to 2026.

12V battery full charge capacity TOYOTA_12V_CAP

  • Request22 15 E5
  • Service 22DID 15E5
  • Module7D2 → 7DA
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 Ah
Unit
Ah

In testing for 2004 to 2026.

B+ battery voltage TOYOTA_BATTERY_VOLTAGE

  • Request22 10 21
  • Service 22DID 1021
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 20 V
Unit
V

In testing for 2004 to 2026.

B+ battery voltage TOYOTA_BATTERY_VOLTAGE_7C0

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 21
  • Service 22DID 1021
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 20 V
Unit
V

In testing for 2004 to 2026.

Electric load feedback TOYOTA_ELEC_LOAD_FB

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
(val × 10 ÷ 8192 − 40)
Range
-40 to 39.99
Unit
Number

In testing for 2004 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.