Toyota GR Supra

Engine parameters

The Toyota GR Supra has 28 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine oil temperature SUPRA_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 DA 25
  • Service 22DID DA25
  • Module6F1 → 618
  • Every30 s
  • Testing for 1988 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0030 = 48 → (48 − 48) = 0 °C

Formula
(val − 48)
Range
-49 to 250 °C
Unit
°C

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1988 to 2002, 2023 to 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Barometric pressure SUPRA_BARO

  • Request22 42 01
  • Service 22DID 4201
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 256)
Range
0 to 255.99 kPa
Unit
kPa

In testing for 1988 to 2002, 2020 to 2026.

Boost pressure SUPRA_BOOST_P

  • Request22 42 05
  • Service 22DID 4205
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511.99 kPa
Unit
kPa

In testing for 1988 to 2002, 2020 to 2026.

Boost pressure, set point SUPRA_BOOST_P_SET

  • Request22 4A B0
  • Service 22DID 4AB0
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 256)
Range
0 to 255.99 kPa
Unit
kPa

In testing for 1988 to 2002, 2020 to 2026.

Catalyst temperature SUPRA_CAT_T

  • Request22 58 2F
  • Service 22DID 582F
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.15)
Range
-273.15 to 6280 °C
Unit
°C

In testing for 1988 to 2002, 2020 to 2026.

Crank torque SUPRA_CRANK_TQ

  • Request22 58 BA
  • Service 22DID 58BA
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 N·m
Unit
N·m

In testing for 1988 to 2002, 2020 to 2026.

Engine load SUPRA_LOAD

  • Request22 58 13
  • Service 22DID 5813
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 %
Unit
%

In testing for 1988 to 2002, 2020 to 2026.

Engine load 2 SUPRA_LOAD_2

  • Request22 4A 4B
  • Service 22DID 4A4B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2002, 2020 to 2026.

Engine load, target SUPRA_LOAD_TGT

  • Request22 48 0C
  • Service 22DID 480C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 3 ÷ 128)
Range
0 to 1535 %
Unit
%

In testing for 1988 to 2002, 2020 to 2026.

Engine oil pressure SUPRA_EOPConfirmed

  • Request22 58 6F
  • Service 22DID 586F
  • Module6F1 → 612
  • Every30 s
  • Testing for 1988 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 15 of the reply, 16 bits.

0x0382 = 898 → (898 ÷ 1000) = 0.898 bar

Formula
(val ÷ 1000)
Range
0 to 65.535 bar
Unit
bar

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1988 to 2002, 2023 to 2024.

Engine oil temperature SUPRA_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 DA 25
  • Service 22DID DA25
  • Module6F1 → 618
  • Every30 s
  • Testing for 1988 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0030 = 48 → (48 − 48) = 0 °C

Formula
(val − 48)
Range
-49 to 250 °C
Unit
°C

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1988 to 2002, 2023 to 2024.

Engine oil temperature SUPRA_EOT_DME

Pelican can show this parameter as the engine oil temperature.

  • Request22 44 08
  • Service 22DID 4408
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.15)
Range
-273.15 to 6280 °C
Unit
°C

In testing for 1988 to 2002, 2020 to 2026.

Ignition angle SUPRA_IGN_ANGLE

  • Request22 59 FA
  • Service 22DID 59FA
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 1988 to 2002, 2020 to 2026.

Ignition timing, cylinder 1 SUPRA_IGN_TIMING_1

  • Request22 4A 49
  • Service 22DID 4A49
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 1988 to 2002, 2020 to 2026.

Ignition timing, cylinder 2 SUPRA_IGN_TIMING_2

  • Request22 4A 4A
  • Service 22DID 4A4A
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 1988 to 2002, 2020 to 2026.

Ignition timing, cylinder 3 SUPRA_IGN_TIMING_3

  • Request22 4A 4C
  • Service 22DID 4A4C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 1988 to 2002, 2020 to 2026.

Ignition timing, cylinder 4 SUPRA_IGN_TIMING_4

  • Request22 4A 4D
  • Service 22DID 4A4D
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 1988 to 2002, 2020 to 2026.

Intake air temperature SUPRA_IAT_DME

  • Request22 58 0F
  • Service 22DID 580F
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 1988 to 2002, 2020 to 2026.

Intake manifold pressure SUPRA_MAP

  • Request22 4A 2D
  • Service 22DID 4A2D
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511.99 kPa
Unit
kPa

In testing for 1988 to 2002, 2020 to 2026.

Kickdown SUPRA_KICKDOWNConfirmed

  • Request22 DA 1F
  • Service 22DID DA1F
  • Module6F1 → 618
  • Every1 s
  • Testing for 1988 to 2002, 2023 to 2024

Example reply from a 2026 Toyota GR Supra.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 100
Unit
Number

Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1988 to 2002, 2023 to 2024.

Lambda SUPRA_LAMBDA

  • Request22 58 89
  • Service 22DID 5889
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 16 ÷ 65535)
Range
0 to 16
Unit
Number

In testing for 1988 to 2002, 2020 to 2026.

Lambda 2 SUPRA_LAMBDA_2

  • Request22 58 2C
  • Service 22DID 582C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.99
Unit
Number

In testing for 1988 to 2002, 2020 to 2026.

Oil level SUPRA_OIL_LEVEL

  • Request22 44 2C
  • Service 22DID 442C
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2002, 2020 to 2026.

Rev limiter SUPRA_REV_LIMIT

  • Request22 4A 2E
  • Service 22DID 4A2E
  • Module6F1 → 612
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1988 to 2002, 2020 to 2026.

Time in d SUPRA_TIME_D

  • Request22 DA 37
  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Time in m SUPRA_TIME_M

  • Request22 DA 37
  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Time in s SUPRA_TIME_S

  • Request22 DA 37
  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Transmission fluid temperature SUPRA_ATF_TEMP

  • Request22 DA 12
  • Service 22DID DA12
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Variable geometry turbocharger calibration angle SUPRA_VGT_CAL_ANGLE

  • Request22 DF E7
  • Service 22DID DFE7
  • Module6F1 → 619
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 156.25 ÷ 10000)
Range
0 to 1000 °
Unit
°

In testing for 1988 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.