Engine parameters
The Toyota GR Supra has 28 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Barometric pressure SUPRA_BARO
- Request
22 42 01 - Service 22
DID 4201 - Module
6F1 → 612 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256)- Range
- 0 to 255.99 kPa
- Unit
- kPa
In testing for 1988 to 2002, 2020 to 2026.
Boost pressure SUPRA_BOOST_P
- Request
22 42 05 - Service 22
DID 4205 - Module
6F1 → 612 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511.99 kPa
- Unit
- kPa
In testing for 1988 to 2002, 2020 to 2026.
Boost pressure, set point SUPRA_BOOST_P_SET
- Request
22 4A B0 - Service 22
DID 4AB0 - Module
6F1 → 612 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256)- Range
- 0 to 255.99 kPa
- Unit
- kPa
In testing for 1988 to 2002, 2020 to 2026.
Catalyst temperature SUPRA_CAT_T
- Request
22 58 2F - Service 22
DID 582F - Module
6F1 → 612 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.15)- Range
- -273.15 to 6280 °C
- Unit
- °C
In testing for 1988 to 2002, 2020 to 2026.
Crank torque SUPRA_CRANK_TQ
- Request
22 58 BA - Service 22
DID 58BA - Module
6F1 → 612 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 N·m
- Unit
- N·m
In testing for 1988 to 2002, 2020 to 2026.
Engine load SUPRA_LOAD
- Request
22 58 13 - Service 22
DID 5813 - Module
6F1 → 612 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 %
- Unit
- %
In testing for 1988 to 2002, 2020 to 2026.
Engine load 2 SUPRA_LOAD_2
- Request
22 4A 4B - Service 22
DID 4A4B - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2002, 2020 to 2026.
Engine load, target SUPRA_LOAD_TGT
- Request
22 48 0C - Service 22
DID 480C - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 3 ÷ 128)- Range
- 0 to 1535 %
- Unit
- %
In testing for 1988 to 2002, 2020 to 2026.
Engine oil pressure SUPRA_EOPConfirmed
- Request
22 58 6F - Service 22
DID 586F - Module
6F1 → 612 - Every
30 s - Testing for 1988 to 2002, 2023 to 2024
Example reply from a 2026 Toyota GR Supra.
Bits 0 to 15 of the reply, 16 bits.
0x0382 = 898 → (898 ÷ 1000) = 0.898 bar
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 bar
- Unit
- bar
Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1988 to 2002, 2023 to 2024.
Engine oil temperature SUPRA_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 DA 25 - Service 22
DID DA25 - Module
6F1 → 618 - Every
30 s - Testing for 1988 to 2002, 2023 to 2024
Example reply from a 2026 Toyota GR Supra.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0030 = 48 → (48 − 48) = 0 °C
- Formula
(val − 48)- Range
- -49 to 250 °C
- Unit
- °C
Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1988 to 2002, 2023 to 2024.
Engine oil temperature SUPRA_EOT_DME
Pelican can show this parameter as the engine oil temperature.
- Request
22 44 08 - Service 22
DID 4408 - Module
6F1 → 612 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.15)- Range
- -273.15 to 6280 °C
- Unit
- °C
In testing for 1988 to 2002, 2020 to 2026.
Ignition angle SUPRA_IGN_ANGLE
- Request
22 59 FA - Service 22
DID 59FA - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 1988 to 2002, 2020 to 2026.
Ignition timing, cylinder 1 SUPRA_IGN_TIMING_1
- Request
22 4A 49 - Service 22
DID 4A49 - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
In testing for 1988 to 2002, 2020 to 2026.
Ignition timing, cylinder 2 SUPRA_IGN_TIMING_2
- Request
22 4A 4A - Service 22
DID 4A4A - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
In testing for 1988 to 2002, 2020 to 2026.
Ignition timing, cylinder 3 SUPRA_IGN_TIMING_3
- Request
22 4A 4C - Service 22
DID 4A4C - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
In testing for 1988 to 2002, 2020 to 2026.
Ignition timing, cylinder 4 SUPRA_IGN_TIMING_4
- Request
22 4A 4D - Service 22
DID 4A4D - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
In testing for 1988 to 2002, 2020 to 2026.
Intake air temperature SUPRA_IAT_DME
- Request
22 58 0F - Service 22
DID 580F - Module
6F1 → 612 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 1988 to 2002, 2020 to 2026.
Intake manifold pressure SUPRA_MAP
- Request
22 4A 2D - Service 22
DID 4A2D - Module
6F1 → 612 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511.99 kPa
- Unit
- kPa
In testing for 1988 to 2002, 2020 to 2026.
Kickdown SUPRA_KICKDOWNConfirmed
- Request
22 DA 1F - Service 22
DID DA1F - Module
6F1 → 618 - Every
1 s - Testing for 1988 to 2002, 2023 to 2024
Example reply from a 2026 Toyota GR Supra.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 100
- Unit
- Number
Confirmed for 2020 to 2022, 2025 to 2026. In testing for 1988 to 2002, 2023 to 2024.
Lambda SUPRA_LAMBDA
- Request
22 58 89 - Service 22
DID 5889 - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 16 ÷ 65535)- Range
- 0 to 16
- Unit
- Number
In testing for 1988 to 2002, 2020 to 2026.
Lambda 2 SUPRA_LAMBDA_2
- Request
22 58 2C - Service 22
DID 582C - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.99
- Unit
- Number
In testing for 1988 to 2002, 2020 to 2026.
Oil level SUPRA_OIL_LEVEL
- Request
22 44 2C - Service 22
DID 442C - Module
6F1 → 612 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2002, 2020 to 2026.
Rev limiter SUPRA_REV_LIMIT
- Request
22 4A 2E - Service 22
DID 4A2E - Module
6F1 → 612 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 1988 to 2002, 2020 to 2026.
Time in d SUPRA_TIME_D
- Request
22 DA 37 - Service 22
DID DA37 - Module
6F1 → 618 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.
Time in m SUPRA_TIME_M
- Request
22 DA 37 - Service 22
DID DA37 - Module
6F1 → 618 - Every
30 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.
Time in s SUPRA_TIME_S
- Request
22 DA 37 - Service 22
DID DA37 - Module
6F1 → 618 - Every
30 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.
Transmission fluid temperature SUPRA_ATF_TEMP
- Request
22 DA 12 - Service 22
DID DA12 - Module
6F1 → 618 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.
Variable geometry turbocharger calibration angle SUPRA_VGT_CAL_ANGLE
- Request
22 DF E7 - Service 22
DID DFE7 - Module
6F1 → 619 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 156.25 ÷ 10000)- Range
- 0 to 1000 °
- Unit
- °
In testing for 1988 to 2002, 2023 to 2024. Not supported for 2020 to 2022, 2025 to 2026.