Toyota C-HR+

Climate parameters

The Toyota C-HR+ has 16 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Adjusted ambient temperature CHR_ADJUSTED_AMBIENT_TConfirmed

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 0 to 7 of the reply, 8 bits.

0x5A = 90 → (90 × 81.6 ÷ 255 − 30.8) = -2 °C

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Adjusted ambient temperature CHR_ADJUSTED_AMBIENT_TConfirmed

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 0 to 7 of the reply, 8 bits.

0x5A = 90 → (90 × 81.6 ÷ 255 − 30.8) = -2 °C

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Air inlet damper actual pulse CHR_AIR_INLET_DAMPER_ACTUAL_PULSEConfirmed

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 8 to 15 of the reply, 8 bits.

0x5C = 92 → 92

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Air inlet damper target pulse CHR_AIR_INLET_DAMPER_TARGET_PULSEConfirmed

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 0 to 7 of the reply, 8 bits.

0x5C = 92 → 92

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Air outlet servo actual pulse, driver CHR_AIR_OUTLET_SERVO_ACTU_PULSE_DConfirmed

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 8 to 15 of the reply, 8 bits.

0x80 = 128 → 128

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Air outlet servo pulse, driver CHR_AIR_OUTLET_SERVO_PULSE_DConfirmed

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 0 to 7 of the reply, 8 bits.

0x80 = 128 → 128

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Ambient air temperature CHR_AAT_7C4Confirmed

  • Request21 22
  • Service 21PID 22
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 0 to 7 of the reply, 8 bits.

0x3C = 60 → (60 × 89.25 ÷ 255 − 23.3) = -2.3 °C

Formula
(val × 89.25 ÷ 255 − 23.3)
Range
-23.3 to 65.95 °C
Unit
°C

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Ambient temperature CHR_AMBIENT_TConfirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 Toyota C-HR+.

Bits 0 to 7 of the reply, 8 bits.

0x3F = 63 → (63 − 40) = 23 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019.

Blower motor speed level CHR_BLOWER_MOTOR_SPEED_LEVELConfirmed

  • Request21 3C
  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Cabin temperature CHR_CABIN_TConfirmed

  • Request21 21
  • Service 21PID 21
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 0 to 7 of the reply, 8 bits.

0x4D = 77 → (77 × 63.75 ÷ 255 − 6.5) = 12.75 °C

Formula
(val × 63.75 ÷ 255 − 6.5)
Range
-6.5 to 57.25 °C
Unit
°C

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Communication with air conditioner CHR_COMM_WITH_AIR_CONDITIONER

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Communication with HV CHR_COMMUNICATION_WITH_HV

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Communication with valvematic CHR_COMM_WITH_VALVEMATIC_COMM

  • Request21 24
  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Evaporator fin thermistor CHR_EVAP_FIN_THERMISTORConfirmed

  • Request21 4B
  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 0 to 7 of the reply, 8 bits.

0x51 = 81 → (81 × 89.25 ÷ 255 − 29.7) = -1.35 °C

Formula
(val × 89.25 ÷ 255 − 29.7)
Range
-29.7 to 59.55 °C
Unit
°C

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Evaporator target temperature CHR_EVAP_TARGET_TConfirmed

  • Request21 4C
  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 0 to 15 of the reply, 16 bits.

0x8064 = 32868 → (32868 ÷ 100 − 327.68) = 1

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67
Unit
Number

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.

Set temperature, driver side CHR_T_DRIVER

  • Request21 29
  • Service 21PID 29
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2019, 2024.

Solar sensor, driver side CHR_SOLAR_DRIVERConfirmed

  • Request21 24
  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2016 to 2018, 2020 to 2026

Example reply from a 2019 Toyota C-HR+.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 2016 to 2018, 2020 to 2023, 2025 to 2026. Not supported for 2024.