Suzuki SX4

Light parameters

The Suzuki SX4 has 7 light parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Stop light SUZUKI_STOP_LIGHT_SWITCHConfirmed

  • Request21 25
  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2010 Suzuki SX4.

Bit 5 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2010. In testing for 2006 to 2009, 2011 to 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Check engine SW SUZUKI_CHECK_ENGINE_LIGHT

  • Request21 12
  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2009, 2011 to 2025. Not supported for 2010.

Hazard switch history SUZUKI_HAZARD_SWITCH_HISTORY

  • Request21 BC
  • Service 21PID BC
  • Module7B0
  • Every1 s
  • Testing

Bit 2 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0INCOMPLETEIncomplete
1COMPLETEComplete

In testing for 2006 to 2009, 2011 to 2025. Not supported for 2010.

Oil pressure switch SUZUKI_EOP_LIGHT

  • Request21 12
  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2009, 2011 to 2025. Not supported for 2010.

P-seatbelt buckle SW SUZUKI_P_SEATBELT_BUCKLE_LIGHT

  • Request21 12
  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2009, 2011 to 2025. Not supported for 2010.

Rheostat SUZUKI_RHEOSTAT

Higher values are brighter

  • Request21 68
  • Service 21PID 68
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2009, 2011 to 2025. Not supported for 2010.

Stop light SUZUKI_STOP_LIGHT_SWITCHConfirmed

  • Request21 25
  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2010 Suzuki SX4.

Bit 5 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2010. In testing for 2006 to 2009, 2011 to 2025.

Tail cancel SW SUZUKI_TAIL_CANCEL_LIGHT

  • Request21 12
  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2009, 2011 to 2025. Not supported for 2010.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.