Climate parameters
The Suzuki Jimny has 30 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
Adjusted ambient temperature SUZUKI_ADJUSTED_AMBIENT_T
- Request
21 3D - Service 21
PID 3D - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 81.6 ÷ 255 − 30.8)- Range
- -30.8 to 50.8 °C
- Unit
- °C
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Air conditioner feedback SUZUKI_AC_FB
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
(val × 10 ÷ 8192 − 40)- Range
- -40 to 39.99
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
Air conditioning inverter gate SUZUKI_AC_GATE
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 67 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2026.
Air conditioning power consumption SUZUKI_AC_PWR
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 kW
- Unit
- kW
In testing for 1988 to 2026.
Air conditioning requested SUZUKI_AC_REQ
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2026.
Air inlet damper actual pulse SUZUKI_AIR_INLET_DAMPER_ACTUAL_PULSE
- Request
21 44 - Service 21
PID 44 - Module
7C4 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Air inlet damper target pulse SUZUKI_AIR_INLET_DAMPER_TARGET_PULSE
- Request
21 44 - Service 21
PID 44 - Module
7C4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Air outlet servo actual pulse, driver SUZUKI_AIR_OUTLET_SERVO_ACTU_PULSE_D
- Request
21 43 - Service 21
PID 43 - Module
7C4 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Air outlet servo pulse, driver SUZUKI_AIR_OUTLET_SERVO_PULSE_D
- Request
21 43 - Service 21
PID 43 - Module
7C4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Ambient air temperature SUZUKI_AAT_7C4
- Request
21 22 - Service 21
PID 22 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 89.25 ÷ 255 − 23.3)- Range
- -23.3 to 65.95 °C
- Unit
- °C
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Ambient temperature SUZUKI_AMBIENT_T
- Request
22 1F 46 - Service 22
DID 1F46 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2008, 2010 to 2022, 2024, 2026. Not supported for 2009, 2023, 2025.
Ambient temperature for A/C SUZUKI_AC_AMB_T
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2024, 2026. Not supported for 2025.
Ambient temperature, climate SUZUKI_AAT_7C4_V2
- Request
22 10 02 - Service 22
DID 1002 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2026.
Blower level SUZUKI_BLOWER
- Request
22 28 01 - Service 22
DID 2801 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 7
- Unit
- Number
In testing for 1988 to 2026.
Blower motor speed level SUZUKI_BLOWER_MOTOR_SPEED_LEVEL
- Request
21 3C - Service 21
PID 3C - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Cabin mode active while parked SUZUKI_MY_ROOM
- Request
22 16 92 - Service 22
DID 1692 - Module
745 → 74D - Every
10 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 1988 to 2026.
Cabin temperature SUZUKI_CABIN_T
- Request
21 21 - Service 21
PID 21 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 63.75 ÷ 255 − 6.5)- Range
- -6.5 to 57.25 °C
- Unit
- °C
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Cabin temperature SUZUKI_CABIN_T_V2
- Request
22 10 01 - Service 22
DID 1001 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 1988 to 2026.
Climate control engine run requested SUZUKI_HVAC_REQ
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
250 ms - Testing
Bit 12 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2026.
Climate power SUZUKI_HVAC_P
- Request
22 10 6E - Service 22
DID 106E - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 kW
- Unit
- kW
In testing for 1988 to 2026.
Climate power, charging control SUZUKI_HVAC_P_745
- Request
22 10 6E - Service 22
DID 106E - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 kW
- Unit
- kW
In testing for 1988 to 2026.
Climate set point code SUZUKI_HVAC_SET_RAW
- Request
22 10 36 - Service 22
DID 1036 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2026.
Communication with air conditioner SUZUKI_COMM_WITH_AIR_CONDITIONER
- Request
21 24 - Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Communication with HV SUZUKI_COMMUNICATION_WITH_HV
- Request
21 24 - Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2024, 2026. Not supported for 2025.
Communication with valvematic SUZUKI_COMM_WITH_VALVEMATIC_COMM
- Request
21 24 - Service 21
PID 24 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2024, 2026. Not supported for 2025.
Electric heater power count SUZUKI_HEATER_RAW
- Request
22 10 86 - Service 22
DID 1086 - Module
7C4 → 7CC - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2026.
Evaporator fin thermistor SUZUKI_EVAP_FIN_THERMISTOR
- Request
21 4B - Service 21
PID 4B - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 89.25 ÷ 255 − 29.7)- Range
- -29.7 to 59.55 °C
- Unit
- °C
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Evaporator target temperature SUZUKI_EVAP_TARGET_T
- Request
21 4C - Service 21
PID 4C - Module
7C4 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67
- Unit
- Number
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Set temperature, driver side SUZUKI_T_DRIVER
- Request
21 29 - Service 21
PID 29 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.
Solar sensor, driver side SUZUKI_SOLAR_DRIVER
- Request
21 24 - Service 21
PID 24 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2022, 2024, 2026. Not supported for 2023, 2025.