Engine parameters
The Škoda Superb has 1,060 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C clutch SKODA_CLIMATE_A_C_CLCH
- Request
22 48 2B - Service 22
DID 482B - Module
746 → 7B0 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
A/C compressor load SKODA_CLIMATE_A_C_COMP_LOAD
- Request
22 26 04 - Service 22
DID 2604 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 N·m
- Unit
- N·m
In testing for 2001 to 2026.
A/C compressor torque SKODA_A_C_COMPRESSOR_TORQUE
- Request
22 10 1A - Service 22
DID 101A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
A/C compressor torque SKODA_A_C_COMPRESSOR_TORQUE_V2
- Request
22 10 1A - Service 22
DID 101A - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
A/C refrigerant pressure SKODA_A_C_REFRIGERANT_PRES
- Request
22 10 17 - Service 22
DID 1017 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2001 to 2026.
A/C refrigerant pressure SKODA_A_C_REFRIGERANT_PRES_V2
- Request
22 10 17 - Service 22
DID 1017 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2001 to 2026.
Actual turbo boost SKODA_ACT_TURBO_BOOST
- Request
22 11 F0 - Service 22
DID 11F0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 2 bar
- Unit
- bar
In testing for 2001 to 2026.
Adaptation of loss torque SKODA_ADPT_LOSS_TQ
- Request
22 29 29 - Service 22
DID 2929 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Adaptation of throttle valve SKODA_ADPT_THROTTLE_VLV
- Request
22 29 2B - Service 22
DID 292B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Adaptation val.cylinder1 fast diagnosis SKODA_ADPT_VAL_CYL1_FAST
- Request
22 3F 45 - Service 22
DID 3F45 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2001 to 2026.
Adaptation val.cylinder1 slow diagnosis SKODA_ADPT_VAL_CYL1_SLOW
- Request
22 3F 41 - Service 22
DID 3F41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2001 to 2026.
Adaptation val.cylinder2 fast diagnosis SKODA_ADPT_VAL_CYL2_FAST
- Request
22 3F 48 - Service 22
DID 3F48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2001 to 2026.
Adaptation val.cylinder2 slow diagnosis SKODA_ADPT_VAL_CYL2_SLOW
- Request
22 3F 44 - Service 22
DID 3F44 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2001 to 2026.
Adaptation val.cylinder3 fast diagnosis SKODA_ADPT_VAL_CYL3_FAST
- Request
22 3F 46 - Service 22
DID 3F46 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2001 to 2026.
Adaptation val.cylinder3 slow diagnosis SKODA_ADPT_VAL_CYL3_SLOW
- Request
22 3F 42 - Service 22
DID 3F42 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2001 to 2026.
Adaptation val.cylinder4 fast diagnosis SKODA_ADPT_VAL_CYL4_FAST
- Request
22 3F 47 - Service 22
DID 3F47 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2001 to 2026.
Adaptation val.cylinder4 slow diagnosis SKODA_ADPT_VAL_CYL4_SLOW
- Request
22 3F 43 - Service 22
DID 3F43 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53
- Unit
- Number
In testing for 2001 to 2026.
Adaptive mode SKODA_ADAPTIVE_MODE
- Request
22 10 11 - Service 22
DID 1011 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Air conditioning compressor pressure SKODA_AC_COMP_P
- Request
22 10 17 - Service 22
DID 1017 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070
- Unit
- Raw value
In testing for 2001 to 2026.
Air conditioning compressor pressure, linear raw value SKODA_AC_COMP_P_LINEAR_RAW
- Request
22 15 C7 - Service 22
DID 15C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070
- Unit
- Raw value
In testing for 2001 to 2026.
Air conditioning compressor refrigerant pressure SKODA_AC_COMP_REFRIGERANT_P
- Request
22 10 48 - Service 22
DID 1048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2001 to 2026.
Air conditioning compressor torque SKODA_AC_COMP_TQ
- Request
22 10 4B - Service 22
DID 104B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Air conditioning compressor torque SKODA_AC_COMP_TQ_V2
- Request
22 10 23 - Service 22
DID 1023 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Air conditioning compressor torque SKODA_AC_COMP_TQ_V4
- Request
22 20 17 - Service 22
DID 2017 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Air conditioning refrigerant pressure SKODA_AC_REFRIGERANT_P
- Request
22 41 2A - Service 22
DID 412A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2001 to 2026.
Air filling SKODA_AIR_FILLING
- Request
22 12 1C - Service 22
DID 121C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 11719 ÷ 500000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Air intake vacuum SKODA_AIR_VAC
- Request
22 18 16 - Service 22
DID 1816 - Module
713 → 77D - Every
5 s - Testing
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- 0 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Air leakage SKODA_AIR_LEAKAGE
- Request
22 11 B8 - Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2001 to 2026.
Air mass SKODA_AIR_MASS
- Request
22 13 CD - Service 22
DID 13CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047
- Unit
- Raw value
In testing for 2001 to 2026.
Air mass meter 1 SKODA_MQB_AIR_MASS_1
- Request
22 10 24 - Service 22
DID 1024 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2001 to 2026.
Air mass, actual value, mg/stroke SKODA_AIR_MASS_ACT_MG
- Request
22 29 D1 - Service 22
DID 29D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Air mass, specified value SKODA_AIR_MASS_SPEC
- Request
22 10 4C - Service 22
DID 104C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2001 to 2026.
Air pollution level SKODA_CLIMATE_AIR_POLUTION_LVL
- Request
22 26 ED - Service 22
DID 26ED - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -12.8 to 12.7
- Unit
- Number
In testing for 2001 to 2026.
All-wheel drive temperature SKODA_PQ35_HAL_T
- Request
22 2B F1 - Service 22
DID 2BF1 - Module
70F → 779 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 100 − 227.67)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2001 to 2026.
All-wheel-drive pump current SKODA_AWD_PMP_CURRENT
- Request
22 2B 0D - Service 22
DID 2B0D - Module
71D → 787 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9563 ÷ 25500 − 47.63)- Range
- -47.63 to 47.9999 A
- Unit
- A
In testing for 2001 to 2026.
Alternator load SKODA_ALTERNATOR_LOAD
- Request
22 10 24 - Service 22
DID 1024 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 W
- Unit
- W
In testing for 2001 to 2026.
Ambient air pressure SKODA_AMBIENT_AIR_P
- Request
22 15 09 - Service 22
DID 1509 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 39 ÷ 1000)- Range
- 0 to 2555.8649
- Unit
- Raw value
In testing for 2001 to 2026.
Ambient air temperature SKODA_DASH_AMBIENT_AIR_T
- Request
22 10 14 - Service 22
DID 1014 - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.5 − 50)- Range
- -50 to 77.5 °C
- Unit
- °C
In testing for 2001 to 2026.
Ambient air temperature, v1 SKODA_AAT_V1
- Request
22 14 F8 - Service 22
DID 14F8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.18 − 460)- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2001 to 2026.
Ambient temperature SKODA_AAT_7E0
- Request
22 11 23 - Service 22
DID 1123 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Ambient temperature SKODA_AAT_7E0_2
- Request
22 10 00 - Service 22
DID 1000 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2001 to 2026.
Analysis-39 driving recorder total time SKODA_ANALYSIS_39_DRIVING
- Request
22 10 AF - Service 22
DID 10AF - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 5)- Range
- 0 to 858993459 s
- Unit
- s
In testing for 2001 to 2026.
Analysis, clutch 1, maximum temperature SKODA_ANALYSIS_CLU_1_MAX_T
- Request
22 10 64 - Service 22
DID 1064 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2001 to 2026.
Analysis, clutch 2, maximum temperature SKODA_ANALYSIS_CLU_2_MAX_T
- Request
22 10 79 - Service 22
DID 1079 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2001 to 2026.
Automatic engine starts counter SKODA_AUTOMATIC_ENG_STARTS
- Request
22 29 99 - Service 22
DID 2999 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Automatic transmission fluid temperature, lifetime max SKODA_ATF_MAX
- Request
22 70 4F - Service 22
DID 704F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
Automatic transmission fluid temperature, variant 2 SKODA_MQB_TCM_ATF_T_VAR_2_DSG_S_TRONIC
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 21 04 - Service 22
DID 2104 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
Aux. hydraulic pump internal temperature SKODA_AUX_HYDRAULIC_PMP_T
- Request
22 51 A6 - Service 22
DID 51A6 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
Aux. hydraulic pump, current SKODA_AUX_HYDRAULIC_PMP
- Request
22 4E 76 - Service 22
DID 4E76 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 A
- Unit
- A
In testing for 2001 to 2026.
Average ignition timing angle delay adjustment SKODA_AVG_IGN_TIM_ANG
- Request
22 29 49 - Service 22
DID 2949 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2001 to 2026.
Avg. injection time SKODA_AVG_INJ_TIME
- Request
22 12 8C - Service 22
DID 128C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 2500)- Range
- 0 to 1717986 ms
- Unit
- ms
In testing for 2001 to 2026.
Avg. injection time SKODA_AVG_INJ_TIME_7E0
- Request
22 20 03 - Service 22
DID 2003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25 ms
- Unit
- ms
In testing for 2001 to 2026.
Barometric pressure SKODA_BAROMETRIC_P
- Request
22 15 09 - Service 22
DID 1509 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 kPa
- Unit
- kPa
In testing for 2001 to 2026.
Basic correction factor:, cylinder 1, filtered SKODA_BASIC_CORR_FACTOR_1
- Request
22 17 1A - Service 22
DID 171A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 65535000)- Range
- 0 to 7.999
- Unit
- Number
In testing for 2001 to 2026.
Basic correction factor:, cylinder 2, filtered SKODA_BASIC_CORR_FACTOR_2
- Request
22 17 1D - Service 22
DID 171D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 65535000)- Range
- 0 to 7.999
- Unit
- Number
In testing for 2001 to 2026.
Basic correction factor:, cylinder 3, filtered SKODA_BASIC_CORR_FACTOR_3
- Request
22 17 1B - Service 22
DID 171B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 65535000)- Range
- 0 to 7.999
- Unit
- Number
In testing for 2001 to 2026.
Basic correction factor:, cylinder 4, filtered SKODA_BASIC_CORR_FACTOR_4
- Request
22 17 1C - Service 22
DID 171C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 65535000)- Range
- 0 to 7.999
- Unit
- Number
In testing for 2001 to 2026.
BMC-E temperature, 1 SKODA_BMS_BMCE_T1
- Request
22 18 0C - Service 22
DID 180C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
BMC-E temperature, 2 SKODA_BMS_BMCE_T2
- Request
22 18 0D - Service 22
DID 180D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
BMC-E temperature, 3 SKODA_BMS_BMCE_T3
- Request
22 18 0E - Service 22
DID 180E - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
BMC-E temperature, 4 SKODA_BMS_BMCE_T_CAN
- Request
22 18 10 - Service 22
DID 1810 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
Boost press before throttle: calculated actual value SKODA_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACT
- Request
22 18 1A - Service 22
DID 181A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2500)- Range
- -81920000 to 81917500
- Unit
- Raw value
In testing for 2001 to 2026.
Boost pressure actuator, commanded duty SKODA_BOOST_P_ACTUATOR_CMD
- Request
22 16 EE - Service 22
DID 16EE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.0122068184)- Range
- -399.993 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Boost pressure commanded SKODA_BOOST_P_CMD
- Request
22 11 49 - Service 22
DID 1149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Boost pressure, actual SKODA_BOOST_P_ACT
- Request
22 11 F0 - Service 22
DID 11F0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2001 to 2026.
Boost pressure, actual SKODA_BOOST_P_ACT_V2
- Request
22 11 1E - Service 22
DID 111E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 5242
- Unit
- Raw value
In testing for 2001 to 2026.
Boost pressure, target SKODA_BOOST_P_TGT
- Request
22 11 18 - Service 22
DID 1118 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550
- Unit
- Raw value
In testing for 2001 to 2026.
Boost regulation duty, commanded value SKODA_BOOST_REGULATION_CMD
- Request
22 12 19 - Service 22
DID 1219 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0234384354)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Boost regulator feedback SKODA_BOOST_REGULATOR
- Request
22 11 CC - Service 22
DID 11CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Boost regulator feedback SKODA_BOOST_REGULATOR_FEEDBACK
- Request
22 11 CC - Service 22
DID 11CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Break pressure SKODA_BREAK_P
- Request
22 2B 21 - Service 22
DID 2B21 - Module
713 → 77D - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 152999 ÷ 10000000 − 42.503)- Range
- -543 to 458 bar
- Unit
- bar
In testing for 2001 to 2026.
Bypass valve high pressure turbine inlet, activation SKODA_BYPASS_VLV_HIGH_P_TURBINE_INLET_V2
- Request
22 39 FF - Service 22
DID 39FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Bypass valve high pressure turbine inlet, activation SKODA_BYPASS_VLV_HIGH_P_V2
- Request
22 39 FF - Service 22
DID 39FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Bypass valve high pressure turbine inlet, actual value SKODA_BYPASS_VLV_HIGH_P_ACT
- Request
22 39 FC - Service 22
DID 39FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 25 ÷ 2048)- Range
- -400 to 399 %
- Unit
- %
In testing for 2001 to 2026.
Bypass valve high pressure turbine inlet, offset closed SKODA_BYPASS_VLV_HIGH_P
- Request
22 39 FD - Service 22
DID 39FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.012207)- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Bypass valve high pressure turbine inlet, offset closed SKODA_BYPASS_VLV_HIGH_P_TURBINE
- Request
22 39 FD - Service 22
DID 39FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.012207)- Range
- -399 to 399 %
- Unit
- %
In testing for 2001 to 2026.
Bypass valve high pressure turbine inlet, offset open SKODA_BYPASS_VLV_HIGH_P_TURBINE_INLET
- Request
22 39 FE - Service 22
DID 39FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.012207)- Range
- -399 to 399 %
- Unit
- %
In testing for 2001 to 2026.
Bypass valve high pressure turbine inlet, offset open SKODA_BYPASS_VLV_HIGH_P_TURBINE_V2
- Request
22 39 FE - Service 22
DID 39FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.012207)- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Bypass valve high pressure turbine inlet, target value SKODA_BYPASS_VLV_HIGH_P_TGT
- Request
22 39 FB - Service 22
DID 39FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 25 ÷ 2048)- Range
- -400 to 399 %
- Unit
- %
In testing for 2001 to 2026.
Bze_q_elad SKODA_BZE_Q_ELAD
- Request
22 12 3A - Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2001 to 2026.
Bze_q_lad SKODA_BZE_Q_LAD
- Request
22 12 3A - Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2001 to 2026.
Cabin temperature SKODA_C7_CABIN_T
- Request
22 26 13 - Service 22
DID 2613 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 256)- Range
- -128 to 127.99 °C
- Unit
- °C
In testing for 2001 to 2026.
Cabin temperature SKODA_CABIN_T
- Request
22 26 13 - Service 22
DID 2613 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Calculated oil temperature SKODA_PQ35_CALCULATED_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 20 A1 - Service 22
DID 20A1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
Camshaft adaptation exhaust bank 1, phase position SKODA_CAM_ADPT_EXH_BANK_1_PHASE
- Request
22 20 23 - Service 22
DID 2023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adaptation intake bank 1, phase position SKODA_CAM_ADPT_INT_BANK_1_PHASE
- Request
22 12 FE - Service 22
DID 12FE - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720 to 719 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adaptation intake bank 1, phase position SKODA_CAM_ADPT_INT_BANK_1_PHASE_V2
- Request
22 20 21 - Service 22
DID 2021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adaptation intake, phase position SKODA_CAM_ADPT_INT_PHASE
- Request
22 10 93 - Service 22
DID 1093 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 35999 ÷ 1638350)- Range
- -720 to 719 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adaptation, counter due to knock SKODA_CAM_ADPT_CNT_KNOCK
- Request
22 52 3B - Service 22
DID 523B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Camshaft adaptation, exhaust bank 1, phase position SKODA_CAM_ADPT_EXH_BANK_1
- Request
22 11 28 - Service 22
DID 1128 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adaptation, intake bank 1, phase position SKODA_CAM_ADPT_INT_BANK_1
- Request
22 11 25 - Service 22
DID 1125 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adaptation, intake deviation SKODA_CAM_ADPT_INT_DEV
- Request
22 4F F5 - Service 22
DID 4FF5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 128)- Range
- -256 to 255.9921 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adjustment intake bank 1, activation % SKODA_CAM_ADJ_INT_BANK_1
- Request
22 29 30 - Service 22
DID 2930 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Camshaft adjustment intake test bank 1 SKODA_CAM_ADJ_INT_TEST_1
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
Camshaft adjustment outlet test bank 1 SKODA_CAM_ADJ_OUTLET_TEST_1
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
Camshaft adjustment, exhaust bank 1, actual value SKODA_CAM_ADJ_EXH_BANK_1_ACT
- Request
22 13 6C - Service 22
DID 136C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adjustment, exhaust bank 1, specified value SKODA_CAM_ADJ_EXH_BANK_1_SPEC
- Request
22 13 71 - Service 22
DID 1371 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adjustment, exhaust bank 2, actual value SKODA_CAM_ADJ_EXH_BANK_2_ACT
- Request
22 13 6D - Service 22
DID 136D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adjustment, exhaust bank 2, specified value SKODA_CAM_ADJ_EXH_BANK_2_SPEC
- Request
22 13 72 - Service 22
DID 1372 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262 to 262 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adjustment, exhaust, activation SKODA_CAM_ADJ_EXH
- Request
22 12 7B - Service 22
DID 127B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Camshaft adjustment, exhaust, actual value SKODA_CAM_ADJ_EXH_ACT
- Request
22 20 1A - Service 22
DID 201A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adjustment, exhaust, specified value SKODA_CAM_ADJ_EXH_SPEC
- Request
22 20 19 - Service 22
DID 2019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adjustment, intake bank 1, actual value SKODA_CAM_ADJ_INT_BANK_1_ACT
- Request
22 13 6E - Service 22
DID 136E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adjustment, intake bank 1, specified value SKODA_CAM_ADJ_INT_BANK_1_SPEC
- Request
22 13 73 - Service 22
DID 1373 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262 to 262 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adjustment, intake, actual value SKODA_CAM_ADJ_INT_ACT
- Request
22 20 1E - Service 22
DID 201E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft adjustment, intake, specified value SKODA_CAM_ADJ_INT_SPEC
- Request
22 20 1D - Service 22
DID 201D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft end position SKODA_CAMS_END
- Request
22 13 41 - Service 22
DID 1341 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft position, deviation from the base position SKODA_CAM_POS_DEV_BASE_POS
- Request
22 13 85 - Service 22
DID 1385 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft position, start of phase window SKODA_CAM_POS_START_PHASE
- Request
22 10 07 - Service 22
DID 1007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720 to 719 °
- Unit
- °
In testing for 2001 to 2026.
Camshaft start position SKODA_PQ35_CAMS_START
- Request
22 10 07 - Service 22
DID 1007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 °
- Unit
- °
In testing for 2001 to 2026.
Cat. converter oxygen storage capacity measured SKODA_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED
- Request
22 15 07 - Service 22
DID 1507 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 10000)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2001 to 2026.
Cat. converter oxygen storage capacity measured SKODA_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED_V2
- Request
22 15 07 - Service 22
DID 1507 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 10000)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2001 to 2026.
Cat. temperature, bank 1 SKODA_CAT_T_BANK_1
- Request
22 12 98 - Service 22
DID 1298 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 273.15)- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2001 to 2026.
Cat. temperature, bank 2 SKODA_CAT_T_BANK_2
- Request
22 12 99 - Service 22
DID 1299 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 273.15)- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2001 to 2026.
Catalyst temperature, calculated SKODA_CAT_T_CALC
- Request
22 15 15 - Service 22
DID 1515 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 − 50)- Range
- -50 to 1225 °C
- Unit
- °C
In testing for 2001 to 2026.
Centrifugal oil temperature SKODA_PQ35_CENTRIFUGAL_OIL_T
- Request
22 38 B2 - Service 22
DID 38B2 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127
- Unit
- Number
In testing for 2001 to 2026.
Chain elongation inlet, mileage at last adaptation SKODA_CHAIN_ELONGATION_INLET
- Request
22 51 6C - Service 22
DID 516C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2001 to 2026.
Chain elongation outlet, mileage at last adaptation SKODA_CHAIN_ELONGATION
- Request
22 51 49 - Service 22
DID 5149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2001 to 2026.
Chain elongation, no of valid initial values, exhaust bank 1 SKODA_CHAIN_ELONGATION_NO_VALID_1
- Request
22 41 89 - Service 22
DID 4189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Chain elongation, no of valid initial values, intake bank 1 SKODA_CHAIN_ELONGATION_NO_1
- Request
22 41 87 - Service 22
DID 4187 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Clutch #1 maximum temperature SKODA_PQ35_CLUTCH_1_MAXIMUM_T
- Request
22 11 18 - Service 22
DID 1118 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2001 to 2026.
Clutch #2 maximum temperature SKODA_PQ35_CLUTCH_2_MAXIMUM_T
- Request
22 11 18 - Service 22
DID 1118 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2001 to 2026.
Clutch 0 temperature calculated SKODA_C7_CLUTCH_0_T_CALCULATED
- Request
22 12 0F - Service 22
DID 120F - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 600 °C
- Unit
- °C
In testing for 2001 to 2026.
Clutch 0 temperature calculated SKODA_MQB_DL382_CLUTCH_0_T_CALCULATED
- Request
22 12 0F - Service 22
DID 120F - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -40 to 600 °C
- Unit
- °C
In testing for 2001 to 2026.
Clutch 1 temperature SKODA_CLUTCH_1_T
- Request
22 10 2B - Service 22
DID 102B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2001 to 2026.
Clutch 1 temperature SKODA_PQ35_CLUTCH_1_T
- Request
22 10 2B - Service 22
DID 102B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2001 to 2026.
Clutch 1 temperature protection overheat protection 1 quantity SKODA_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY
- Request
22 38 81 - Service 22
DID 3881 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Clutch 1 temperature protection warning 1 quantity SKODA_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTY
- Request
22 38 7F - Service 22
DID 387F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Clutch 1 temperature protection warning 2 quantity SKODA_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTY
- Request
22 38 80 - Service 22
DID 3880 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Clutch 2 temperature SKODA_CLUTCH_2_T
- Request
22 10 2C - Service 22
DID 102C - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2001 to 2026.
Clutch 2 temperature SKODA_PQ35_CLUTCH_2_T
- Request
22 10 2C - Service 22
DID 102C - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2001 to 2026.
Clutch 2 temperature protection overheat protection 1 quantity SKODA_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY
- Request
22 38 85 - Service 22
DID 3885 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Clutch 2 temperature protection warning 1 quantity SKODA_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTY
- Request
22 38 83 - Service 22
DID 3883 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Clutch 2 temperature protection warning 2 quantity SKODA_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTY
- Request
22 38 84 - Service 22
DID 3884 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Clutch center central plate temperature SKODA_CLU_CENTER_CENTRAL_T
- Request
22 10 2A - Service 22
DID 102A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2001 to 2026.
Clutch temperature SKODA_DIFF_CLUTCH_T
- Request
22 F1 05 - Service 22
DID F105 - Module
71E → 788 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 2 − 50)- Range
- -50 to 460 °C
- Unit
- °C
In testing for 2001 to 2026.
Commanded crankshaft torque SKODA_CMD_CRANK_TQ
- Request
22 11 E0 - Service 22
DID 11E0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Compression test cylinder 1 SKODA_COMPRESSION_TEST_CYL_1
- Request
22 11 29 - Service 22
DID 1129 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Compression test cylinder 2 SKODA_PQ35_COMP_TEST_CYL_2
- Request
22 11 2A - Service 22
DID 112A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Compression test cylinder 3 SKODA_PQ35_COMP_TEST_CYL_3
- Request
22 11 2B - Service 22
DID 112B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Compression test cylinder 4 SKODA_PQ35_COMP_TEST_CYL_4
- Request
22 11 2C - Service 22
DID 112C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Compression test, cylinder 1 SKODA_COMPRESSION_TEST_CYL_1_V2
- Request
22 29 9B - Service 22
DID 299B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Compression test, cylinder 2 SKODA_COMPRESSION_TEST_CYL_2
- Request
22 29 9C - Service 22
DID 299C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Compression test, cylinder 3 SKODA_COMPRESSION_TEST_CYL_3
- Request
22 29 9D - Service 22
DID 299D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Compression test, cylinder 4 SKODA_COMPRESSION_TEST_CYL_4
- Request
22 29 9E - Service 22
DID 299E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Control module temperature SKODA_CTRL_MODULE_T
- Request
22 03 01 - Service 22
DID 0301 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
Control module temperature SKODA_CTRL_MODULE_T_V2
- Request
22 02 8D - Service 22
DID 028D - Module
71D → 787 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
Control module temperature SKODA_ECU_TEMP
- Request
22 02 8D - Service 22
DID 028D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Control module temperature SKODA_ECU_TEMP_K
- Request
22 02 8D - Service 22
DID 028D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Control module temperature SKODA_ECU_TEMP_KELVIN
- Request
22 02 8D - Service 22
DID 028D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -40 to 150 °C
- Unit
- °C
In testing for 2001 to 2026.
Control module temperature SKODA_MQB_TCM_ECU_T
- Request
22 02 8D - Service 22
DID 028D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2001 to 2026.
Converter loss torque SKODA_TCM_CONVERTER_LOSS_TORQUE
- Request
22 10 10 - Service 22
DID 1010 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Coolant circulation pump duty SKODA_COOLANT_CIRC_PUMP_DUTY
- Request
22 27 6D - Service 22
DID 276D - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Coolant circulation pump, activation SKODA_CLT_CIRCULATION_PMP_ACTIVATION
- Request
22 27 6D - Service 22
DID 276D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Coolant circulation pump, control SKODA_CLT_CIRCULATION_PMP
- Request
22 16 7E - Service 22
DID 167E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan 1 activation, $1117 SKODA_CLT_FAN_1_ACTIVATION_1117
- Request
22 11 17 - Service 22
DID 1117 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan 1 duty cycle SKODA_COOL_FAN_1_DUTY
- Request
22 11 16 - Service 22
DID 1116 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan 1, activation SKODA_CLT_FAN_1_ACTIVATION
- Request
22 20 55 - Service 22
DID 2055 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan 1, activation SKODA_COOLANT_FAN_1_ACTIVATION
- Request
22 11 30 - Service 22
DID 1130 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan 1, activation SKODA_COOLANT_FAN_1_ACTIVATION_V2
- Request
22 11 30 - Service 22
DID 1130 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan 2 duty SKODA_CLT_FAN_2_DUTY
- Request
22 11 14 - Service 22
DID 1114 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan 2 duty cycle SKODA_PQ35_COOL_FAN_2_DUTY
- Request
22 11 14 - Service 22
DID 1114 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan 2, activation SKODA_CLT_FAN_2_ACTIVATION
- Request
22 20 56 - Service 22
DID 2056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan activation, actual value SKODA_CLT_FAN_ACTIVATION_ACT
- Request
22 26 06 - Service 22
DID 2606 - Module
70E → 778 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan activation, specified value SKODA_CLT_FAN_ACTIVATION_SPEC
- Request
22 26 07 - Service 22
DID 2607 - Module
70E → 778 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2001 to 2026.
Coolant fan, requested by A/C SKODA_CLT_FAN_REQ_AC
- Request
22 10 18 - Service 22
DID 1018 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 1000000)- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Coolant shut-off valve, closed SKODA_CLT_SHUT_OFF_VLV
- Request
22 26 82 - Service 22
DID 2682 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127
- Unit
- Number
In testing for 2001 to 2026.
Coolant temperature at engine outlet, calculated SKODA_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED
- Request
22 44 90 - Service 22
DID 4490 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at engine outlet, calculated SKODA_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED_V2
- Request
22 44 90 - Service 22
DID 4490 - Module
FC00 → FE0076 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at engine outlet, calculated SKODA_ECT_ENG_OUTLET_CALC
- Request
22 10 64 - Service 22
DID 1064 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at engine start SKODA_COOLANT_T_AT_ENGINE_START
- Request
22 12 91 - Service 22
DID 1291 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at engine start SKODA_COOLANT_T_AT_ENGINE_START_V2
- Request
22 12 91 - Service 22
DID 1291 - Module
FC00 → FE0076 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at engine start SKODA_ECT_ENG_START
- Request
22 29 35 - Service 22
DID 2935 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at radiator outlet SKODA_COOLANT_T
- Request
22 11 35 - Service 22
DID 1135 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at radiator outlet SKODA_EARLY_COOLANT_T
- Request
22 11 35 - Service 22
DID 1135 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 300 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at radiator outlet SKODA_ECT_RADIATOR_OUTLET
- Request
22 11 B5 - Service 22
DID 11B5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at radiator outlet 2 SKODA_ECT_RAD_OUT_2
- Request
22 10 9B - Service 22
DID 109B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at radiator outlet v.1 SKODA_ECT_RADIATOR_OUTLET_V_1
- Request
22 15 CD - Service 22
DID 15CD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at radiator outlet, actual value SKODA_ECT_RADIATOR_OUTLET_ACT
- Request
22 20 2B - Service 22
DID 202B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at radiator outlet, actual value SKODA_ECT_RADIATOR_OUTLET_ACT_7E0
- Request
22 10 2C - Service 22
DID 102C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at radiator outlet, specified value SKODA_ECT_RADIATOR_OUTLET_SPEC
- Request
22 20 2C - Service 22
DID 202C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature at radiator output, specified value SKODA_COOLANT_T_AT_RADIATOR_OUTPUT_SPECIFIED_VALUE
- Request
22 11 35 - Service 22
DID 1135 - Module
FC00 → FE0076 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature difference between engine and radiator SKODA_ECT_DIFF_ENG
- Request
22 20 2E - Service 22
DID 202E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature linear SKODA_ECT_LINEAR
- Request
22 15 13 - Service 22
DID 1513 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 29297 ÷ 10000000 − 48)- Range
- -48 to 143.9978 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature modeled value SKODA_COOLANT_T_MODELED_VALUE
- Request
22 13 A0 - Service 22
DID 13A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature modeled value SKODA_COOLANT_T_MODELED_VALUE_V2
- Request
22 13 A0 - Service 22
DID 13A0 - Module
FC00 → FE0076 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature, maximum value SKODA_ECT_MAX
- Request
22 15 11 - Service 22
DID 1511 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2001 to 2026.
Coolant temperature, minimum value SKODA_ECT_MIN
- Request
22 15 12 - Service 22
DID 1512 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2001 to 2026.
Cooling fan 2 SKODA_COOLING_FAN_2
- Request
22 11 2E - Service 22
DID 112E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2001 to 2026.
Cooling inlet temperature SKODA_BMS_COOL_IN_T
- Request
22 18 1C - Service 22
DID 181C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
Cooling outlet temperature SKODA_BMS_COOL_OUT_T
- Request
22 18 1D - Service 22
DID 181D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
Correction factor of oil temperature for engine protection SKODA_CORR_FACTOR_OIL_T
- Request
22 3F 4F - Service 22
DID 3F4F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12207 ÷ 100000000)- Range
- 0 to 7.99
- Unit
- Number
In testing for 2001 to 2026.
Correction values for main pressure adaptation SKODA_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT
- Request
22 11 A7 - Service 22
DID 11A7 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2001 to 2026.
Coupling solenoid current SKODA_CPL_SOL_I
- Request
22 18 00 - Service 22
DID 1800 - Module
70F → 779 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 6250000)- Range
- -63.99 to 63.99 A
- Unit
- A
In testing for 2001 to 2026.
Crankshaft rotation angle when closing the quantity control valve SKODA_CRANK_ROT_ANG
- Request
22 10 EB - Service 22
DID 10EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2001 to 2026.
Critical engine oil level SKODA_PQ35_OIL_LVL_CRIT
- Request
22 11 BD - Service 22
DID 11BD - Module
7E0 → 7E8 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 250)- Range
- -131.072 to 131.068 mm
- Unit
- mm
In testing for 2001 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 0 SKODA_CTR_MIS_DC_MMV_CYL_0
- Request
22 14 8D - Service 22
DID 148D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 1 SKODA_CTR_MIS_DC_MMV_CYL_1
- Request
22 14 8E - Service 22
DID 148E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 2 SKODA_CTR_MIS_DC_MMV_CYL_2
- Request
22 14 8F - Service 22
DID 148F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Current N215 pressure control valve 1 SKODA_CURRENT_N215_P_CTRL_1
- Request
22 10 24 - Service 22
DID 1024 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2001 to 2026.
Current N216 pressure control valve 2 SKODA_CURRENT_N216_P_CTRL_2
- Request
22 10 26 - Service 22
DID 1026 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2001 to 2026.
Current N217 pressure control valve 3 SKODA_CURRENT_N217_P_CTRL_3
- Request
22 10 28 - Service 22
DID 1028 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2001 to 2026.
Current N218 pressure control valve 4 SKODA_CURRENT_N218_P_CTRL_4
- Request
22 10 25 - Service 22
DID 1025 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2001 to 2026.
Current N233 pressure control valve 5 SKODA_CURRENT_N233_P_CTRL_5
- Request
22 10 27 - Service 22
DID 1027 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2001 to 2026.
Current N443 pressure control valve 7 main pressure SKODA_CURRENT_N443_P_CTRL_7_P
- Request
22 10 2A - Service 22
DID 102A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2001 to 2026.
Current solenoid SKODA_CURRENT_SOLENOID
- Request
22 10 37 - Service 22
DID 1037 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2001 to 2026.
Current type of driver counter SKODA_CURRENT_TYPE_DRIVER
- Request
22 10 13 - Service 22
DID 1013 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Cylinder 1 internal torque SKODA_CYL_1_INTERNAL_TQ
- Request
22 58 47 - Service 22
DID 5847 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Cylinder 2 internal torque SKODA_CYL_2_INTERNAL_TQ
- Request
22 58 49 - Service 22
DID 5849 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Cylinder 3 internal torque SKODA_CYL_3_INTERNAL_TQ
- Request
22 58 4B - Service 22
DID 584B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Cylinder 4 internal torque SKODA_CYL_4_INTERNAL_TQ
- Request
22 58 4D - Service 22
DID 584D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Cylinder block temperature sensor SKODA_CYL_BLOCK_T_SENS
- Request
22 51 D4 - Service 22
DID 51D4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Cylinder head temperature SKODA_CYL_HEAD_T
- Request
22 10 65 - Service 22
DID 1065 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 460)- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2001 to 2026.
Cylinder head temperature, actual SKODA_CYL_HEAD_T_ACT
- Request
22 10 65 - Service 22
DID 1065 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Desired torque filtered SKODA_DES_TQ_FILTERED
- Request
22 10 64 - Service 22
DID 1064 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Desired torque raw SKODA_DES_TQ_RAW
- Request
22 10 61 - Service 22
DID 1061 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Diesel particulate filter air pressure sensor raw value SKODA_DPF_AIR_P_SENS_RAW
- Request
22 44 94 - Service 22
DID 4494 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter ash load limit SKODA_DPF_ASH_LOAD_LIM
- Request
22 40 6B - Service 22
DID 406B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter cleaning deviation reaction time SKODA_DPF_CLEANING_DEV
- Request
22 44 F5 - Service 22
DID 44F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -32.768 to 32.767
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter counter for regeneration time SKODA_DPF_CNT_REGEN_TIME
- Request
22 39 F9 - Service 22
DID 39F9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100)- Range
- 0 to 42949672 s
- Unit
- s
In testing for 2001 to 2026.
Diesel particulate filter differential pressure SKODA_DPF_DIFF_P
- Request
22 20 84 - Service 22
DID 2084 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter differential pressure offset SKODA_PQ35_DPF_DIFF_P_OFFSET
- Request
22 10 F1 - Service 22
DID 10F1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter differential pressure raw value, bank 1 SKODA_DPF_DIFF_P_RAW_BANK_1
- Request
22 16 6B - Service 22
DID 166B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter differential pressure raw value, bank 2 SKODA_DPF_DIFF_P_RAW_BANK_2
- Request
22 16 6C - Service 22
DID 166C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter differential pressure sensor temperature SKODA_DPF_DIFF_P_SENS_T
- Request
22 43 C0 - Service 22
DID 43C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 19531 ÷ 1000000 − 50)- Range
- -689.9918 to 589.9722 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter differential pressure variant 2 SKODA_PQ35_DPF_DIFF_P_2
- Request
22 10 F3 - Service 22
DID 10F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter differential pressure, raw value 1 SKODA_DPF_DIFF_P_RAW_1
- Request
22 43 BC - Service 22
DID 43BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter differential pressure, raw value 2 SKODA_DPF_DIFF_P_RAW_2
- Request
22 43 BF - Service 22
DID 43BF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter exhaust gas flow volume SKODA_DPF_EXH_VOL
- Request
22 11 E6 - Service 22
DID 11E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter exhaust temperature SKODA_DPF_EXH_T
- Request
22 44 F8 - Service 22
DID 44F8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter field regeneration, cancel conditions SKODA_DPF_FIELD_REGEN
- Request
22 29 F7 - Service 22
DID 29F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter field regeneration, lock status SKODA_DPF_FIELD_REGEN_LOCK_V2
- Request
22 20 88 - Service 22
DID 2088 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter field regeneration, request status SKODA_DPF_FIELD_REGEN_REQ
- Request
22 20 87 - Service 22
DID 2087 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter inlet temperature SKODA_PQ35_DPF_IN_T
- Request
22 11 B2 - Service 22
DID 11B2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter input gas temperature SKODA_DPF_INPUT_GAS_T
- Request
22 29 7B - Service 22
DID 297B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4 − 20)- Range
- -20 to 1000 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter input gas temperature SKODA_DPF_INPUT_GAS_T_7E0
- Request
22 44 9B - Service 22
DID 449B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter input temperature raw value SKODA_DPF_INPUT_T_RAW
- Request
22 44 9B - Service 22
DID 449B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter offset for differential pressure SKODA_DPF_OFFSET_DIFF_P
- Request
22 20 85 - Service 22
DID 2085 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter oil ash mass SKODA_DPF_OIL_ASH_MASS
- Request
22 40 6C - Service 22
DID 406C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter oil ash mass SKODA_MQB_DPF_OIL_ASH_MASS
- Request
22 1A BD - Service 22
DID 1ABD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0011921 ÷ 10000)- Range
- 0 to 512
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter oil ash volume SKODA_DPF_OIL_ASH_VOLUME
- Request
22 20 8B - Service 22
DID 208B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 L
- Unit
- L
In testing for 2001 to 2026.
Diesel particulate filter oil ash volume, bank 1 SKODA_DPF_OIL_ASH_VOLUME_1
- Request
22 14 B9 - Service 22
DID 14B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 L
- Unit
- L
In testing for 2001 to 2026.
Diesel particulate filter oil ash volume, bank 2 SKODA_DPF_OIL_ASH_VOLUME_2
- Request
22 14 5F - Service 22
DID 145F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 L
- Unit
- L
In testing for 2001 to 2026.
Diesel particulate filter outlet temperature SKODA_EARLY_DPF_OUT_T
- Request
22 10 F9 - Service 22
DID 10F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1200 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter outlet temperature SKODA_PQ35_DPF_OUT_T
- Request
22 10 F9 - Service 22
DID 10F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter output gas temperature SKODA_DPF_OUTPUT_GAS_T
- Request
22 29 7D - Service 22
DID 297D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4 − 20)- Range
- -20 to 1000 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter output temperature raw value SKODA_DPF_OUTPUT_T_RAW
- Request
22 44 9A - Service 22
DID 449A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter regeneration cancel conditions SKODA_DPF_REGEN_CANCEL
- Request
22 13 7C - Service 22
DID 137C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter regeneration level current SKODA_DPF_REGEN_LEVEL
- Request
22 08 0D - Service 22
DID 080D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter regeneration request status SKODA_DPF_REGEN_REQ_STAT
- Request
22 20 87 - Service 22
DID 2087 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter regeneration status SKODA_DPF_REGEN_STAT
- Request
22 08 09 - Service 22
DID 0809 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter soot mass calculated, bank 1 SKODA_DPF_SOOT_MASS_CALC_1
- Request
22 14 BA - Service 22
DID 14BA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter soot mass calculated, bank 2 SKODA_DPF_SOOT_MASS_CALC_2
- Request
22 14 5E - Service 22
DID 145E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter soot mass measured, bank 1 SKODA_DPF_SOOT_MASS_MEAS_1
- Request
22 14 BB - Service 22
DID 14BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter soot mass measured, bank 2 SKODA_DPF_SOOT_MASS_MEAS_2
- Request
22 14 5D - Service 22
DID 145D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter soot measured SKODA_DPF_SOOT_MEAS
- Request
22 20 8C - Service 22
DID 208C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter soot volume in exhaust, mg/m^3 SKODA_DPF_SOOT_VOLUME_EXH_M_3
- Request
22 18 C0 - Service 22
DID 18C0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter statistics current avg. temperature after DPF SKODA_DPF_STATISTICS_T
- Request
22 15 7C - Service 22
DID 157C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter statistics current avg. temperature after part.filter SKODA_DPF_STATISTICS_CURRENT_AVG_T
- Request
22 40 01 - Service 22
DID 4001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter statistics current calculated charging rate, g/km SKODA_DPF_STATISTICS_CURRENT_G
- Request
22 40 07 - Service 22
DID 4007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 100000000)- Range
- -3.99 to 3.99
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter statistics current measured charging rate, g/km SKODA_DPF_STATISTICS_G
- Request
22 40 05 - Service 22
DID 4005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 100000000)- Range
- -3.99 to 3.99
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter statistics, regeneration time SKODA_DPF_STATISTICS_REGEN
- Request
22 40 1F - Service 22
DID 401F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 64)- Range
- 0 to 16320 s
- Unit
- s
In testing for 2001 to 2026.
Diesel particulate filter surface gas temperature SKODA_DPF_SURFACE_GAS_T
- Request
22 3D 7F - Service 22
DID 3D7F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter surface temperature SKODA_DPF_SFC_T
- Request
22 10 44 - Service 22
DID 1044 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter surface temperature SKODA_DPF_SURFACE_T
- Request
22 44 FB - Service 22
DID 44FB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16 − 273.15)- Range
- -2321.15 to 1774.7875 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter surface temperature SKODA_PQ35_DPF_SURF_T
- Request
22 10 44 - Service 22
DID 1044 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Diesel particulate filter time since last regeneration SKODA_DPF_TIME_SINCE_REGEN
- Request
22 20 89 - Service 22
DID 2089 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 1193046 h
- Unit
- h
In testing for 2001 to 2026.
Diesel particulate filter time since last regeneration, h, bank 1 SKODA_DPF_TIME_SINCE_REGEN_H_1
- Request
22 14 34 - Service 22
DID 1434 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 1193046
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter time since last regeneration, h, bank 2 SKODA_DPF_TIME_SINCE_REGEN_H_2
- Request
22 14 64 - Service 22
DID 1464 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 1193046
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter, differential pressure sensor, adapted value SKODA_DPF_DIFF_P_SENS_ADAPTED
- Request
22 44 B2 - Service 22
DID 44B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter, differential pressure sensor, dynamic offset SKODA_DPF_DIFF_P_SENS
- Request
22 44 A3 - Service 22
DID 44A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter, service regeneration while driving SKODA_DPF_SERVICE_REGEN_WHILE
- Request
22 29 10 - Service 22
DID 2910 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter, service regeneration, current duration SKODA_DPF_SERVICE_REGEN
- Request
22 20 7D - Service 22
DID 207D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2001 to 2026.
Differential pressure SKODA_DIFF_P
- Request
22 14 F5 - Service 22
DID 14F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Direct injections counter SKODA_DIRECT_INJECTIONS
- Request
22 42 67 - Service 22
DID 4267 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2001 to 2026.
Drive motor current SKODA_MOTOR_I
- Request
22 14 7D - Service 22
DID 147D - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 A
- Unit
- A
In testing for 2001 to 2026.
Drive motor effective current SKODA_MOTOR_I_RMS
- Request
22 46 65 - Service 22
DID 4665 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.937 A
- Unit
- A
In testing for 2001 to 2026.
Drive motor phase U current SKODA_MOTOR_U_I
- Request
22 3E F9 - Service 22
DID 3EF9 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2001 to 2026.
Drive motor phase U current, unlimited SKODA_MOTOR_U_I_RAW
- Request
22 46 71 - Service 22
DID 4671 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2001 to 2026.
Drive motor phase V current SKODA_MOTOR_V_I
- Request
22 3E FA - Service 22
DID 3EFA - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2001 to 2026.
Drive motor phase V current, unlimited SKODA_MOTOR_V_I_RAW
- Request
22 46 70 - Service 22
DID 4670 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2001 to 2026.
Drive motor phase W current SKODA_MOTOR_W_I
- Request
22 3E FB - Service 22
DID 3EFB - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2001 to 2026.
Drive motor phase W current, unlimited SKODA_MOTOR_W_I_RAW
- Request
22 46 6F - Service 22
DID 466F - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2001 to 2026.
Drive motor power SKODA_MOTOR_PWR
- Request
22 14 7E - Service 22
DID 147E - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 250)- Range
- -131.072 to 131.068 kW
- Unit
- kW
In testing for 2001 to 2026.
Drive motor power, actual SKODA_MOTOR_PWR_PE
- Request
22 46 56 - Service 22
DID 4656 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.984 kW
- Unit
- kW
In testing for 2001 to 2026.
Drive motor power, calculated SKODA_MOTOR_PWR_CALC
- Request
22 46 58 - Service 22
DID 4658 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.984 kW
- Unit
- kW
In testing for 2001 to 2026.
Drive motor speed SKODA_MOTOR_RPM_ECM
- Request
22 14 9A - Service 22
DID 149A - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Drive motor speed 2 SKODA_MOTOR_RPM_2
- Request
22 3E EC - Service 22
DID 3EEC - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Drive motor speed, actual SKODA_MOTOR_RPM
Pelican can show this parameter as the engine speed.
- Request
22 3E 97 - Service 22
DID 3E97 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Drive motor speed, measured SKODA_MOTOR_RPM_ACT
- Request
22 46 59 - Service 22
DID 4659 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Drive motor speed, standard SKODA_MOTOR_RPM_SAE
- Request
22 F4 0C - Service 22
DID F40C - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Drive motor stator temperature SKODA_MOTOR_STATOR_T
- Request
22 46 72 - Service 22
DID 4672 - Module
7E6 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2001 to 2026.
Drive motor temperature SKODA_MOTOR_T
- Request
22 3E 94 - Service 22
DID 3E94 - Module
7E6 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2001 to 2026.
Drive motor torque SKODA_MOTOR_TQ
- Request
22 14 7F - Service 22
DID 147F - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 3)- Range
- -10922.666 to 10922.333 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Drive motor torque, actual SKODA_MOTOR_TQ_PE
- Request
22 3E E9 - Service 22
DID 3EE9 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Drive motor torque, calculated SKODA_MOTOR_TQ_CALC
- Request
22 03 08 - Service 22
DID 0308 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Drive motor voltage SKODA_MOTOR_V
- Request
22 14 84 - Service 22
DID 1484 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2001 to 2026.
Driver demand torque SKODA_TCM_DRIVER_DEMAND_TORQUE
- Request
22 10 0B - Service 22
DID 100B - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Driving mode sensor, hall sensor a SKODA_DRIVING_MODE_SENS
- Request
22 21 0D - Service 22
DID 210D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Driving position SKODA_DRIVING_POS
- Request
22 21 0E - Service 22
DID 210E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Driving resistance index SKODA_DRIVING_RES_INDEX
- Request
22 21 08 - Service 22
DID 2108 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127
- Unit
- Number
In testing for 2001 to 2026.
Dynamic average of ignition angle delay adjustment SKODA_DYNAMIC_AVG_IGN_ANG
- Request
22 29 4A - Service 22
DID 294A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2001 to 2026.
Dynamic torque limitation SKODA_DYNAMIC_TQ_LIM
- Request
22 10 67 - Service 22
DID 1067 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Ea888b boost pressure control, adaptation value 0 SKODA_EA888B_BOOST_P_CTRL_0
- Request
22 11 FF - Service 22
DID 11FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2001 to 2026.
Ea888b boost pressure control, adaptation value 1 SKODA_EA888B_BOOST_P_CTRL_1
- Request
22 12 00 - Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2001 to 2026.
Ea888b boost pressure control, adaptation value 2 SKODA_EA888B_BOOST_P_CTRL_2
- Request
22 12 01 - Service 22
DID 1201 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359 to 356
- Unit
- Raw value
In testing for 2001 to 2026.
Ea888b boost pressure control, adaptation value 3 SKODA_EA888B_BOOST_P_CTRL_3
- Request
22 12 02 - Service 22
DID 1202 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359 to 356
- Unit
- Raw value
In testing for 2001 to 2026.
Ea888b boost pressure regulator, commanded SKODA_EA888B_BOOST_P_CMD
- Request
22 11 A3 - Service 22
DID 11A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Early ignition counter for toque reduction, cylinder 1 SKODA_EARLY_IGN_CNT_TOQUE_1
- Request
22 4E 4A - Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter for toque reduction, cylinder 2 SKODA_EARLY_IGN_CNT_TOQUE_2
- Request
22 4E 4A - Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter for toque reduction, cylinder 3 SKODA_EARLY_IGN_CNT_TOQUE_3
- Request
22 4E 4A - Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter for toque reduction, cylinder 4 SKODA_EARLY_IGN_CNT_TOQUE_4
- Request
22 4E 4A - Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder 1 SKODA_EARLY_IGN_CNT_CYL_1
- Request
22 17 22 - Service 22
DID 1722 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder 2 SKODA_EARLY_IGN_CNT_CYL_2
- Request
22 17 25 - Service 22
DID 1725 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder 3 SKODA_EARLY_IGN_CNT_CYL_3
- Request
22 17 23 - Service 22
DID 1723 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder 4 SKODA_EARLY_IGN_CNT_CYL_4
- Request
22 17 24 - Service 22
DID 1724 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 1 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_1
- Request
22 4E 49 - Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 2 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_2
- Request
22 4E 49 - Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 3 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_3
- Request
22 4E 49 - Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 4 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_4
- Request
22 4E 49 - Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 1 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_1
- Request
22 4E 4B - Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 2 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_2
- Request
22 4E 4B - Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 3 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_3
- Request
22 4E 4B - Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, cylinder suppress glow ignition, cylinder 4 SKODA_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_4
- Request
22 4E 4B - Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, total, cylinder 1 SKODA_EARLY_IGN_CNT_TOT_1
- Request
22 17 15 - Service 22
DID 1715 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, total, cylinder 2 SKODA_EARLY_IGN_CNT_TOT_2
- Request
22 17 18 - Service 22
DID 1718 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, total, cylinder 3 SKODA_EARLY_IGN_CNT_TOT_3
- Request
22 17 16 - Service 22
DID 1716 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Early ignition counter, total, cylinder 4 SKODA_EARLY_IGN_CNT_TOT_4
- Request
22 17 17 - Service 22
DID 1717 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Effective injection duration SKODA_EFFECTIVE_INJ_DUR
- Request
22 15 E7 - Service 22
DID 15E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2001 to 2026.
EGT after catalyst, model bank 1 SKODA_EGT_AFTER_CAT_MODEL_1
- Request
22 2A E9 - Service 22
DID 2AE9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.023438 − 273.15)- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 2001 to 2026.
EGT after catalyst, model bank b SKODA_EGT_AFTER_CAT_MODEL_B
- Request
22 2A E3 - Service 22
DID 2AE3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.023438 − 273.15)- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 2001 to 2026.
Elector motor 1 torque SKODA_EM_TORQ_1
- Request
22 11 53 - Service 22
DID 1153 - Module
7E0 → 7E8 - Every
10.25 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1000 to 1000 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Elector motor 2 torque SKODA_EM_TORQ_2
- Request
22 11 54 - Service 22
DID 1154 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1000 to 1000 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Elector motor 3 torque SKODA_EM_TORQ_3
- Request
22 11 55 - Service 22
DID 1155 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1000 to 1000 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Electric additional coolant pump control, high circle SKODA_ELEC_ADDITIONAL_CLT
- Request
22 14 88 - Service 22
DID 1488 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 1000000)- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Electric motor 1 rpm SKODA_EM_RPM_1
- Request
22 11 51 - Service 22
DID 1151 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -100 to 100 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Electric motor 2 rpm SKODA_EM_RPM_2
- Request
22 11 52 - Service 22
DID 1152 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -100 to 100 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Electric motor non-vehicle power limitation SKODA_EM_NV_PWR_LIM
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 W
- Unit
- W
In testing for 2001 to 2026.
Electric motor power limitation SKODA_EM_PWR_LIM
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 50)- Range
- 0 to 3276750 W
- Unit
- W
In testing for 2001 to 2026.
Electric motor RPM SKODA_ENG_MOTOR_RPM
- Request
22 3D F8 - Service 22
DID 3DF8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Electronic differential lock active SKODA_ELEC_DIFF_ACT
- Request
22 18 0C - Service 22
DID 180C - Module
713 → 77D - Every
5 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
Electronic differential lock front left brake temperature SKODA_ELEC_DIFF_FL_BRK_T
- Request
22 18 0C - Service 22
DID 180C - Module
713 → 77D - Every
5 s - Testing
Bits 8 to 23 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -20 to 300 °C
- Unit
- °C
In testing for 2001 to 2026.
Electronic differential lock front right brake temperature SKODA_ELEC_DIFF_FR_BRK_T
- Request
22 18 0C - Service 22
DID 180C - Module
713 → 77D - Every
5 s - Testing
Bits 24 to 39 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -20 to 300 °C
- Unit
- °C
In testing for 2001 to 2026.
Electronic differential lock rear left brake temperature SKODA_ELEC_DIFF_RL_BRK_T
- Request
22 18 0C - Service 22
DID 180C - Module
713 → 77D - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -20 to 300 °C
- Unit
- °C
In testing for 2001 to 2026.
Electronic differential lock rear right brake temperature SKODA_ELEC_DIFF_RR_BRK_T
- Request
22 18 0C - Service 22
DID 180C - Module
713 → 77D - Every
5 s - Testing
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -20 to 300 °C
- Unit
- °C
In testing for 2001 to 2026.
Energy balance of last driving cycle SKODA_ENERGY_BALANCE_LAST
- Request
22 2A 15 - Service 22
DID 2A15 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 Ah
- Unit
- Ah
In testing for 2001 to 2026.
Energy content SKODA_ENERGY_CONTENT
- Request
22 22 E4 - Service 22
DID 22E4 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2001 to 2026.
Engine air mass, specified value SKODA_ENG_AIR_MASS_SPEC
- Request
22 20 37 - Service 22
DID 2037 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2001 to 2026.
Engine compartment temperature raw value SKODA_ENG_COMPARTMENT_T
- Request
22 46 B1 - Service 22
DID 46B1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine control module temperature SKODA_ENG_CTRL_MODULE_T
- Request
22 02 8D - Service 22
DID 028D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine drag torque SKODA_ENG_DRAG_TQ
- Request
22 20 9C - Service 22
DID 209C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine oil level SKODA_ENG_OIL_LEVEL_7E0
- Request
22 15 04 - Service 22
DID 1504 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mm
- Unit
- mm
In testing for 2001 to 2026.
Engine oil level SKODA_ENG_OIL_LEVEL_7E0_2
- Request
22 11 BC - Service 22
DID 11BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 250)- Range
- -131 to 131 mm
- Unit
- mm
In testing for 2001 to 2026.
Engine oil level SKODA_PQ35_OIL_LVL
- Request
22 11 BC - Service 22
DID 11BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 250)- Range
- -131.072 to 131.068 mm
- Unit
- mm
In testing for 2001 to 2026.
Engine oil level current value SKODA_ENG_OIL_LEVEL
- Request
22 58 D1 - Service 22
DID 58D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Engine oil pressure SKODA_EOP
- Request
22 15 03 - Service 22
DID 1503 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 416)- Range
- 0 to 157 psi
- Unit
- psi
In testing for 2001 to 2026.
Engine oil sump temperature SKODA_ENG_OIL_SUMP_T
- Request
22 15 B7 - Service 22
DID 15B7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 460)- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2001 to 2026.
Engine oil temperature SKODA_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
22 10 E6 - Service 22
DID 10E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 60)- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature SKODA_EOT_714
- Request
22 20 2F - Service 22
DID 202F - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 58)- Range
- 0 to 197
- Unit
- Number
In testing for 2001 to 2026.
Engine oil temperature SKODA_EOT_7E0
- Request
22 11 02 - Service 22
DID 1102 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature SKODA_EOT_7E0_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 20 2F - Service 22
DID 202F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature SKODA_EOT_FC00
Pelican can show this parameter as the engine oil temperature.
- Request
22 11 BD - Service 22
DID 11BD - Module
FC00 → FE0076 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature SKODA_EOT_V2
Scaling is unknown, needs further validation.
- Request
22 11 BE - Service 22
DID 11BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Engine oil temperature SKODA_EOT_V3
- Request
22 20 2F - Service 22
DID 202F - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 58)- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Engine oil temperature SKODA_EOT_V4
- Request
22 20 2F - Service 22
DID 202F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature 2 SKODA_PQ35_ENGINE_OIL_T_2
Pelican can show this parameter as the engine oil temperature.
- Request
22 17 9C - Service 22
DID 179C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature measured value SKODA_EOT_MEAS
Pelican can show this parameter as the engine oil temperature.
- Request
22 16 32 - Service 22
DID 1632 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature sensor 2 SKODA_EOT_SENS_2
Pelican can show this parameter as the engine oil temperature.
- Request
22 40 D5 - Service 22
DID 40D5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature, calculated SKODA_EOT_CALC
- Request
22 20 1A - Service 22
DID 201A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature, engine control module SKODA_EOT_ECM
- Request
22 11 BD - Service 22
DID 11BD - Module
7E0 → 7E8 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature, pulse sensor SKODA_EOT_PULS
- Request
22 17 9E - Service 22
DID 179E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine oil temperature, variant 4 SKODA_EOT_VAR_4
- Request
22 40 D5 - Service 22
DID 40D5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine outlet coolant temperature calculated SKODA_ENG_OUTLET_ECT_CALC
- Request
22 10 63 - Service 22
DID 1063 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Engine protection, torque limit SKODA_ENG_PROTECTION_TQ
- Request
22 2B C0 - Service 22
DID 2BC0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine radiator fan request SKODA_ENG_RADIATOR_FAN_REQ
- Request
22 10 0B - Service 22
DID 100B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Engine start quantity SKODA_PQ35_ENG_START_QTY
- Request
22 10 69 - Service 22
DID 1069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Engine temperature control actuator SKODA_ENG_T_CTRL_ACTUATOR
- Request
22 3D 73 - Service 22
DID 3D73 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Engine temperature management actuator, after-run stop SKODA_ENG_T_MANAGEMENT_ACTUATOR_AFTER
- Request
22 44 1D - Service 22
DID 441D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Engine temperature management actuator, duty cycle activation SKODA_ENG_T_MANAGEMENT_ACTUATOR
- Request
22 44 1A - Service 22
DID 441A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Engine temperature management actuator, raw value SKODA_ENG_T_MANAGEMENT
- Request
22 44 19 - Service 22
DID 4419 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Engine temperature management actuator, specified value SKODA_ENG_T_MANAGEMENT_SPEC
- Request
22 3F E4 - Service 22
DID 3FE4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 1000000)- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Engine temperature management actuator, stop open SKODA_ENG_T_MANAGEMENT_ACTUATOR_STOP
- Request
22 44 1C - Service 22
DID 441C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Engine torque SKODA_ENG_TORQUE
- Request
22 15 5A - Service 22
DID 155A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque SKODA_ENG_TQ
- Request
22 20 02 - Service 22
DID 2002 - Module
71D → 787 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 49 ÷ 625)- Range
- 0 to 5137
- Unit
- Number
In testing for 2001 to 2026.
Engine torque SKODA_ENG_TQ_7E0
- Request
22 10 47 - Service 22
DID 1047 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque SKODA_ENG_TQ_7E0_V2
- Request
22 43 7C - Service 22
DID 437C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque SKODA_ENG_TQ_7E1
- Request
22 70 64 - Service 22
DID 7064 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque SKODA_ENG_TQ_7E1_V2
- Request
22 20 02 - Service 22
DID 2002 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque SKODA_ENG_TQ_V3
- Request
22 20 02 - Service 22
DID 2002 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque SKODA_ENGINE_TORQUE
- Request
22 10 10 - Service 22
DID 1010 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque SKODA_ENGINE_TORQUE_V2
- Request
22 10 10 - Service 22
DID 1010 - Module
FC00 → FE0076 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque SKODA_PQ35_ENG_TORQUE
- Request
22 15 5A - Service 22
DID 155A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.96875 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque SKODA_PQ35_ENG_TRQ
- Request
22 10 47 - Service 22
DID 1047 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque SKODA_TCM_ENGINE_TORQUE
- Request
22 10 0C - Service 22
DID 100C - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque limitation SKODA_ENG_TQ_LIM
- Request
22 10 8F - Service 22
DID 108F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque limitation SKODA_TCM_ENGINE_TORQUE_LIMITATION
- Request
22 10 0E - Service 22
DID 100E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Engine torque loss SKODA_TCM_ENGINE_TORQUE_LOSS
- Request
22 10 0F - Service 22
DID 100F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Environment data camshaft input 1 SKODA_ENVD_CAM_IN_1
- Request
22 12 13 - Service 22
DID 1213 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Evaporator temperature SKODA_EVAPORATOR_T
- Request
22 42 BB - Service 22
DID 42BB - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Excessive temperature protection SKODA_EXCESSIVE_T
- Request
22 21 17 - Service 22
DID 2117 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Exhaust camshaft, adaptation bias SKODA_EXH_CAM_ADPT_BIAS
- Request
22 17 4A - Service 22
DID 174A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2001 to 2026.
Exhaust camshaft, adaptation sensor tolerance SKODA_EXH_CAM_ADPT_SENS
- Request
22 17 55 - Service 22
DID 1755 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2001 to 2026.
Exhaust gas jet volume in particle filter SKODA_EXH_GAS_JET_VOLUME
- Request
22 3D 7E - Service 22
DID 3D7E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100)- Range
- -3276800 to 3276700 L
- Unit
- L
In testing for 2001 to 2026.
Exhaust gas jet volume in particle filter, m^3/h SKODA_EXH_GAS_JET_VOLUME_M_3_H
- Request
22 3D 7E - Service 22
DID 3D7E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364
- Unit
- Number
In testing for 2001 to 2026.
Exhaust gas recirculation valve 2 bank 1 mass flow SKODA_MQB_EGR_VALVE_2_B1_FLOW
- Request
22 13 13 - Service 22
DID 1313 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2001 to 2026.
Exhaust gas recirculation valve duty SKODA_PQ35_EGR_DUTY
- Request
22 10 C2 - Service 22
DID 10C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Exhaust gas temperature SKODA_EXH_GAS_T
- Request
22 F4 3C - Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature - calculated after catalyst SKODA_EXH_GAS_T_CALC_AFTER
- Request
22 2A E9 - Service 22
DID 2AE9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 293 ÷ 12500 − 273.15)- Range
- -273.15 to 1262.9904 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature at probe before the front catalytic converter, model value SKODA_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE
- Request
22 13 9C - Service 22
DID 139C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature at the probe before the front catalytic converter, model value SKODA_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE_V2
- Request
22 13 9C - Service 22
DID 139C - Module
FC00 → FE0076 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature before catalyst SKODA_EXHAUST_GAS_T_BEFORE_CATALYST
- Request
22 12 82 - Service 22
DID 1282 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50 − 193.93)- Range
- -193.93 to 1116.77 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature before catalyst, modeled SKODA_EGT_PRE_CAT_MODELED
- Request
22 14 21 - Service 22
DID 1421 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature before catalytic converter SKODA_EXH_GAS_T_BEFORE
- Request
22 29 6F - Service 22
DID 296F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature before gasoline particulate filter SKODA_EXH_GAS_T_BEFORE_GPF
- Request
22 08 2D - Service 22
DID 082D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature sensor 1 SKODA_EXH_GAS_T_SENS_1
- Request
22 16 6F - Service 22
DID 166F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature sensor 1 SKODA_EXH_GAS_T_SENS_1_V2
- Request
22 29 76 - Service 22
DID 2976 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature sensor 1 SKODA_PQ35_EXH_GAS_T_1
- Request
22 10 FB - Service 22
DID 10FB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature sensor 1, bank 2 SKODA_EXH_GAS_T_SENS_1_2
- Request
22 16 70 - Service 22
DID 1670 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature sensor 2 SKODA_PQ35_EXHAUST_GAS_T_SENSOR_2
- Request
22 14 F7 - Service 22
DID 14F7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature sensor 3 SKODA_EXH_GAS_T_SENS_3
- Request
22 14 BE - Service 22
DID 14BE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature sensor 3 SKODA_EXH_GAS_T_SENS_3_V2
- Request
22 11 B2 - Service 22
DID 11B2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature sensor 3, bank 2 SKODA_EXH_GAS_T_SENS_3_2
- Request
22 15 6F - Service 22
DID 156F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature sensor 4 SKODA_EXH_GAS_T_SENS_4
- Request
22 16 6D - Service 22
DID 166D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust gas temperature, sensor 4, bank 2 SKODA_EXH_GAS_T_S4_B2
- Request
22 16 6E - Service 22
DID 166E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust phase deviation, actual value SKODA_EXH_PHASE_DEV_ACT
- Request
22 41 85 - Service 22
DID 4185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2001 to 2026.
Exhaust phase deviation, after chain replacement SKODA_EXH_PHASE_DEV_AFTER
- Request
22 41 7D - Service 22
DID 417D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2001 to 2026.
Exhaust phase deviation, after repair SKODA_EXH_PHASE_DEV_AFTER_REPAIR
- Request
22 41 81 - Service 22
DID 4181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2001 to 2026.
Exhaust temperature before the catalyst, modeled SKODA_EXH_T_BEFORE_CAT
- Request
22 14 21 - Service 22
DID 1421 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust temperature control downstream oxidation catalyst filtered model error SKODA_MQB_EXH_TEMP_CTRL_AFTER_CAT_MODEL_ERR
- Request
22 1A D7 - Service 22
DID 1AD7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Exhaust timing chain extension, mileage since last adaptation SKODA_EXH_TIM_CHAIN
- Request
22 51 49 - Service 22
DID 5149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2001 to 2026.
Field limit SKODA_FIELD_LIM
- Request
22 11 F6 - Service 22
DID 11F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655
- Unit
- Raw value
In testing for 2001 to 2026.
Field limit value SKODA_PQ35_FIELD_LIM
- Request
22 11 F6 - Service 22
DID 11F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2001 to 2026.
First pilot injection, duration SKODA_PRE_INJ_1_DUR
- Request
22 14 D0 - Service 22
DID 14D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2500)- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 2001 to 2026.
First pilot injection, start SKODA_PRE_INJ_1_START
- Request
22 14 C7 - Service 22
DID 14C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 °
- Unit
- °
In testing for 2001 to 2026.
Friction torque SKODA_FRICTION_TQ
- Request
22 10 65 - Service 22
DID 1065 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Front defrost flap air outlet temperature SKODA_FRONT_DEFROST_FLAP_T
- Request
22 42 C8 - Service 22
DID 42C8 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Front left deflector temperature SKODA_CLIMATE_FR_L_DEFL_T
- Request
22 26 0C - Service 22
DID 260C - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 3)- Range
- 0 to 84.915 °C
- Unit
- °C
In testing for 2001 to 2026.
Front left temperature flap actual value SKODA_CLIMATE_FR_L_T_FLP_ACT_VALUE
- Request
22 26 22 - Service 22
DID 2622 - Module
746 → 7B0 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 0.5)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Front right deflector temperature SKODA_CLIMATE_FR_R_DEFL_T
- Request
22 26 0D - Service 22
DID 260D - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 3)- Range
- 0 to 84.915 °C
- Unit
- °C
In testing for 2001 to 2026.
Front right temperature flap actual value SKODA_CLIMATE_FR_R_T_FLP_ACT_VALUE
- Request
22 26 26 - Service 22
DID 2626 - Module
746 → 7B0 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 0.5)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Fuel metering valve position SKODA_FUEL_METER
- Request
22 11 48 - Service 22
DID 1148 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Fuel temperature SKODA_FUEL_T_7E0
- Request
22 16 2D - Service 22
DID 162D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -40 to 300 °C
- Unit
- °C
In testing for 2001 to 2026.
Fuel temperature SKODA_PQ35_FUEL_T
- Request
22 16 2D - Service 22
DID 162D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Gasoline particulate filter blockage rate calculated SKODA_GPF_BLOCKAGE_RATE_CALC
- Request
22 2A FB - Service 22
DID 2AFB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1280)- Range
- 0 to 51.1992
- Unit
- Number
In testing for 2001 to 2026.
Gasoline particulate filter blockage rate threshold calculated SKODA_GPF_BLOCKAGE_RATE
- Request
22 2A F9 - Service 22
DID 2AF9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1280)- Range
- 0 to 51.1992
- Unit
- Number
In testing for 2001 to 2026.
Gasoline particulate filter blockage ratio calculated absolute SKODA_GPF_BLOCKAGE_RAT
- Request
22 08 27 - Service 22
DID 0827 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100
- Unit
- Number
In testing for 2001 to 2026.
Gasoline particulate filter blockage ratio calculated relative SKODA_GPF_BLOCKAGE_RAT_CALC_REL
- Request
22 08 28 - Service 22
DID 0828 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100
- Unit
- Number
In testing for 2001 to 2026.
Gasoline particulate filter high level moisture build-up SKODA_GPF_HIGH_LEVEL
- Request
22 24 B2 - Service 22
DID 24B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107
- Unit
- Raw value
In testing for 2001 to 2026.
Gasoline particulate filter high level of soot build-up SKODA_GPF_HIGH_LEVEL_SOOT
- Request
22 24 B3 - Service 22
DID 24B3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2001 to 2026.
Gasoline particulate filter loading stage SKODA_GPF_LOADING_STAGE
- Request
22 08 2B - Service 22
DID 082B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Gasoline particulate filter maximum ash build-up reached SKODA_GPF_MAX_ASH_BUILD_UP
- Request
22 24 B5 - Service 22
DID 24B5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510
- Unit
- Raw value
In testing for 2001 to 2026.
Gasoline particulate filter maximum soot build-up reached SKODA_GPF_MAX_SOOT_BUILD
- Request
22 24 B4 - Service 22
DID 24B4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2001 to 2026.
Gasoline particulate filter oil ash load calculated SKODA_GPF_OIL_ASH_LOAD
- Request
22 08 04 - Service 22
DID 0804 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Gasoline particulate filter oil ash mass SKODA_GPF_OIL_ASH_MASS
- Request
22 40 6C - Service 22
DID 406C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2001 to 2026.
Gasoline particulate filter soot load calculated SKODA_GPF_SOOT_LOAD_CALC
- Request
22 08 29 - Service 22
DID 0829 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Gasoline particulate filter soot mass calculated SKODA_GPF_SOOT_MASS_CALC
- Request
22 20 8B - Service 22
DID 208B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2001 to 2026.
Gasoline particulate filter water load SKODA_GPF_WATER_LOAD
- Request
22 08 02 - Service 22
DID 0802 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Gasoline particulate filter water mass SKODA_GPF_WATER_MASS
- Request
22 21 39 - Service 22
DID 2139 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107
- Unit
- Raw value
In testing for 2001 to 2026.
Generator current SKODA_GEN_CURRENT
- Request
22 2A 1C - Service 22
DID 2A1C - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 + 9)- Range
- 0 to 6562.5 A
- Unit
- A
In testing for 2001 to 2026.
Generator load SKODA_GEN_LOAD
- Request
22 10 5C - Service 22
DID 105C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Generator load normalized value SKODA_GENERATOR_LOAD_NORMALIZED_VALUE
- Request
22 15 CA - Service 22
DID 15CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Generator load normalized value SKODA_GENERATOR_LOAD_NORMALIZED_VALUE_V2
- Request
22 15 CA - Service 22
DID 15CA - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Generator load signal SKODA_GEN_LOAD_SIG
- Request
22 10 33 - Service 22
DID 1033 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Generator load signal SKODA_GEN_LOAD_SIG_V3
- Request
22 20 50 - Service 22
DID 2050 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Generator load signal SKODA_GENERATOR_LOAD_SIG
- Request
22 10 1C - Service 22
DID 101C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Generator load signal SKODA_GENERATOR_LOAD_SIG_V2
- Request
22 10 1C - Service 22
DID 101C - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Generator performance SKODA_GENERATOR_PERFORMANCE
- Request
22 10 97 - Service 22
DID 1097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 94248 ÷ 10000)- Range
- -308831.8464 to 308822.421 W
- Unit
- W
In testing for 2001 to 2026.
Generator performance SKODA_GENERATOR_PERFORMANCE_V2
- Request
22 10 97 - Service 22
DID 1097 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 94248 ÷ 10000)- Range
- -308831.8464 to 308822.4216 W
- Unit
- W
In testing for 2001 to 2026.
Generator torque request SKODA_GENERATOR_TORQUE_REQUEST
- Request
22 10 1B - Service 22
DID 101B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Generator torque request SKODA_GENERATOR_TORQUE_REQUEST_V2
- Request
22 10 1B - Service 22
DID 101B - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Heater circulation pump, nominal value SKODA_HEATER_CIRCULATION
- Request
22 16 7F - Service 22
DID 167F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Heater support pump, specified value SKODA_HEATER_SUPPORT_PMP_SPEC
- Request
22 43 36 - Service 22
DID 4336 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Height correction SKODA_HEIGHT_CORR
- Request
22 11 36 - Service 22
DID 1136 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0000610348)- Range
- 0 to 3.9999
- Unit
- Number
In testing for 2001 to 2026.
High pressure control, adaptation SKODA_HIGH_P_CTRL_ADPT
- Request
22 11 D2 - Service 22
DID 11D2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2000)- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 2001 to 2026.
High pressure EGR actuator, activation SKODA_HIGH_P_EGR_ACTUATOR
- Request
22 13 34 - Service 22
DID 1334 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
High pressure regulation, adaptation value SKODA_HIGH_P_REGULATION
- Request
22 43 84 - Service 22
DID 4384 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
High-pressure exhaust gas recirculation closing, variant 1 SKODA_HIGH_P_EGR_CLOSING_1
- Request
22 F4 69 - Service 22
DID F469 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × -25 ÷ 64 + 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
High-pressure exhaust gas recirculation closing, variant 2 SKODA_HIGH_P_EGR_CLOSING_2
- Request
22 F4 2C - Service 22
DID F42C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × -25 ÷ 64 + 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Humidity sensor, relative humidity SKODA_HUMIDITY_SENS_REL
- Request
22 50 36 - Service 22
DID 5036 - Module
70E → 778 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 99 ÷ 200)- Range
- 0 to 32439 %
- Unit
- %
In testing for 2001 to 2026.
Hybrid temperature SKODA_HYBRID_T
- Request
22 11 96 - Service 22
DID 1196 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2001 to 2026.
Hydraulic brake booster active SKODA_HYD_BRK_BST_ACT
- Request
22 18 10 - Service 22
DID 1810 - Module
713 → 77D - Every
5 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
ID of current driving program SKODA_ID_CURRENT_DRIVING
- Request
22 10 12 - Service 22
DID 1012 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
IGA_CYL_KNK, 0 SKODA_IGA_CYL_KNK_0
- Request
22 13 F2 - Service 22
DID 13F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2001 to 2026.
IGA_CYL_KNK, 1 SKODA_IGA_CYL_KNK_1
- Request
22 13 F3 - Service 22
DID 13F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2001 to 2026.
IGA_CYL_KNK, 2 SKODA_IGA_CYL_KNK_2
- Request
22 13 F4 - Service 22
DID 13F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2001 to 2026.
IGA_CYL_KNK, 3 SKODA_IGA_CYL_KNK_3
- Request
22 13 F5 - Service 22
DID 13F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2001 to 2026.
IGA_IGC, 0 SKODA_IGA_IGC_0
- Request
22 13 8A - Service 22
DID 138A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1499 ÷ 4000 − 35.625)- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2001 to 2026.
IGA_IGC, 1 SKODA_IGA_IGC_1
- Request
22 13 8B - Service 22
DID 138B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1499 ÷ 4000 − 35.625)- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2001 to 2026.
IGA_IGC, 2 SKODA_IGA_IGC_2
- Request
22 13 8C - Service 22
DID 138C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1499 ÷ 4000 − 35.625)- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2001 to 2026.
IGA_IGC, 3 SKODA_IGA_IGC_3
- Request
22 13 8D - Service 22
DID 138D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1499 ÷ 4000 − 35.625)- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2001 to 2026.
Ignition angle current cylinder, actual value SKODA_IGN_ANG_CURRENT_CYL_ACT
- Request
22 20 04 - Service 22
DID 2004 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -25 to 25 °
- Unit
- °
In testing for 2001 to 2026.
Ignition timing angle retard, cylinder 1 SKODA_IGNITION_TIMING_ANGLE_RETARD_C1
- Request
22 10 E2 - Service 22
DID 10E2 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 75 ÷ 100)- Range
- -24576 to 24575.25 °
- Unit
- °
In testing for 2001 to 2026.
Ignition timing angle retard, cylinder 2 SKODA_IGNITION_TIMING_ANGLE_RETARD_C2
- Request
22 10 E3 - Service 22
DID 10E3 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 75 ÷ 100)- Range
- -24576 to 24575.25 °
- Unit
- °
In testing for 2001 to 2026.
Ignition timing angle retard, cylinder 3 SKODA_IGNITION_TIMING_ANGLE_RETARD_C3
- Request
22 10 E4 - Service 22
DID 10E4 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 75 ÷ 100)- Range
- -24576 to 24575.25 °
- Unit
- °
In testing for 2001 to 2026.
Ignition timing angle retard, cylinder 4 SKODA_IGNITION_TIMING_ANGLE_RETARD_C4
- Request
22 10 E5 - Service 22
DID 10E5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 75 ÷ 100)- Range
- -24576 to 24575.25 °
- Unit
- °
In testing for 2001 to 2026.
Ignition timing angle retard, cylinder 4 SKODA_IGNITION_TIMING_ANGLE_RETARD_C4_V2
- Request
22 10 E5 - Service 22
DID 10E5 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 75 ÷ 100)- Range
- -24576 to 24575.25 °
- Unit
- °
In testing for 2001 to 2026.
Injection amount deviation cylinder 1 SKODA_INJ_AMOUNT_DEV_CYL_1
- Request
22 20 46 - Service 22
DID 2046 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.00036623)- Range
- -12 to 12
- Unit
- Raw value
In testing for 2001 to 2026.
Injection amount deviation cylinder 1 SKODA_PQ35_INJ_DEV_CYL_1
- Request
22 10 FF - Service 22
DID 10FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Injection amount deviation cylinder 2 SKODA_INJ_AMOUNT_DEV_CYL_2
- Request
22 20 47 - Service 22
DID 2047 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.00036623)- Range
- -12 to 12
- Unit
- Raw value
In testing for 2001 to 2026.
Injection amount deviation cylinder 2 SKODA_PQ35_INJ_DEV_CYL_2
- Request
22 11 05 - Service 22
DID 1105 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Injection amount deviation cylinder 3 SKODA_INJ_AMOUNT_DEV_CYL_3
- Request
22 20 48 - Service 22
DID 2048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.00036623)- Range
- -12 to 12
- Unit
- Raw value
In testing for 2001 to 2026.
Injection amount deviation cylinder 3 SKODA_PQ35_INJ_DEV_CYL_3
- Request
22 11 00 - Service 22
DID 1100 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Injection amount deviation cylinder 4 SKODA_INJ_AMOUNT_DEV_CYL_4
- Request
22 20 49 - Service 22
DID 2049 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.00036623)- Range
- -12 to 12
- Unit
- Raw value
In testing for 2001 to 2026.
Injection amount deviation cylinder 4 SKODA_PQ35_INJ_DEV_CYL_4
- Request
22 11 04 - Service 22
DID 1104 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation cylinder 1 SKODA_INJ_QTY_DEV_CYL_1
- Request
22 10 FF - Service 22
DID 10FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation cylinder 2 SKODA_INJ_QTY_DEV_CYL_2
- Request
22 11 06 - Service 22
DID 1106 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation cylinder 3 SKODA_INJ_QTY_DEV_CYL_3
- Request
22 11 04 - Service 22
DID 1104 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation cylinder 4 SKODA_INJ_QTY_DEV_CYL_4
- Request
22 11 00 - Service 22
DID 1100 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation cylinder 5 SKODA_INJ_QTY_DEV_CYL_5
- Request
22 11 07 - Service 22
DID 1107 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation cylinder 6 SKODA_INJ_QTY_DEV_CYL_6
- Request
22 11 05 - Service 22
DID 1105 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation, cylinder 1 SKODA_INJ_QTY_DEV_CYL_1_V2
- Request
22 20 46 - Service 22
DID 2046 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation, cylinder 2 SKODA_INJ_QTY_DEV_CYL_2_V2
- Request
22 20 4A - Service 22
DID 204A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation, cylinder 3 SKODA_INJ_QTY_DEV_CYL_3_V2
- Request
22 20 48 - Service 22
DID 2048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation, cylinder 4 SKODA_INJ_QTY_DEV_CYL_4_V2
- Request
22 20 47 - Service 22
DID 2047 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation, cylinder 5 SKODA_INJ_QTY_DEV_CYL_5_V2
- Request
22 20 4B - Service 22
DID 204B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injection quantity deviation, cylinder 6 SKODA_INJ_QTY_DEV_CYL_6_V2
- Request
22 20 49 - Service 22
DID 2049 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Injector 1 rail pressure calibration point 1 SKODA_PQ35_INJ_1_RAIL_P_1
- Request
22 10 D0 - Service 22
DID 10D0 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 1 rail pressure calibration point 2 SKODA_INJ_1_RAIL_P_2
- Request
22 10 D6 - Service 22
DID 10D6 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 1 rail pressure calibration point 2 SKODA_PQ35_INJ_1_RAIL_P_2
- Request
22 10 D6 - Service 22
DID 10D6 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.05 ÷ 1000)- Range
- -1.6384 to 1.63835 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 1 rail pressure calibration point 3 SKODA_PQ35_INJ_1_RAIL_P_3
- Request
22 10 DC - Service 22
DID 10DC - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 2 rail pressure calibration point 1 SKODA_INJ_2_RAIL_P_1
- Request
22 10 D3 - Service 22
DID 10D3 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 2 rail pressure calibration point 1 SKODA_PQ35_INJ_2_RAIL_P_1
- Request
22 10 D3 - Service 22
DID 10D3 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.05 ÷ 1000)- Range
- -1.6384 to 1.63835 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 2 rail pressure calibration point 2 SKODA_PQ35_INJ_2_RAIL_P_2
- Request
22 10 D9 - Service 22
DID 10D9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 2 rail pressure calibration point 3 SKODA_PQ35_INJ_2_RAIL_P_3
- Request
22 10 DF - Service 22
DID 10DF - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 2, rail pressure calibration point 1 SKODA_INJ_2_RAIL_P_1_V2
- Request
22 10 D4 - Service 22
DID 10D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 2, rail pressure calibration point 2 SKODA_INJ_2_RAIL_P_2
- Request
22 10 DA - Service 22
DID 10DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 2: rail pressure calibration point 1 SKODA_INJ_2_RAIL_P_CAL_PT_1_146E
- Request
22 14 6E - Service 22
DID 146E - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2001 to 2026.
Injector 2: rail pressure calibration point 2 SKODA_INJ_2_RAIL_P_CAL_PT_2_1474
- Request
22 14 74 - Service 22
DID 1474 - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2001 to 2026.
Injector 2: rail pressure calibration point 3 SKODA_INJ_2_RAIL_P_CAL_PT_3_147A
- Request
22 14 7A - Service 22
DID 147A - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2001 to 2026.
Injector 3 rail pressure calibration point 1 SKODA_INJ_3_RAIL_P_1
- Request
22 10 D1 - Service 22
DID 10D1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 3 rail pressure calibration point 1 SKODA_PQ35_INJ_3_RAIL_P_1
- Request
22 10 D1 - Service 22
DID 10D1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.05 ÷ 1000)- Range
- -1.6384 to 1.63835 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 3 rail pressure calibration point 2 SKODA_PQ35_INJ_3_RAIL_P_2
- Request
22 10 D2 - Service 22
DID 10D2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 3 rail pressure calibration point 3 SKODA_PQ35_INJ_3_RAIL_P_3
- Request
22 10 DD - Service 22
DID 10DD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 4 rail pressure calibration point 2 SKODA_PQ35_INJ_4_RAIL_P_2
- Request
22 10 D8 - Service 22
DID 10D8 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 4 rail pressure calibration point 3 SKODA_INJ_4_RAIL_P_3
- Request
22 10 DE - Service 22
DID 10DE - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 4 rail pressure calibration point 3 SKODA_PQ35_INJ_4_RAIL_P_3
- Request
22 10 DE - Service 22
DID 10DE - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.05 ÷ 1000)- Range
- -1.6384 to 1.63835 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 4, rail pressure calibration point 2 SKODA_INJ_4_RAIL_P_2
- Request
22 10 D7 - Service 22
DID 10D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 5, rail pressure calibration point 1 SKODA_INJ_5_RAIL_P_1
- Request
22 10 D5 - Service 22
DID 10D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 5, rail pressure calibration point 2 SKODA_INJ_5_RAIL_P_2
- Request
22 10 DB - Service 22
DID 10DB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 5, rail pressure calibration point 3 SKODA_INJ_5_RAIL_P_3
- Request
22 10 E1 - Service 22
DID 10E1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2001 to 2026.
Injector 7: rail pressure calibration point 1 SKODA_INJ_7_RAIL_P_CAL_PT_1
- Request
22 14 6D - Service 22
DID 146D - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2001 to 2026.
Injector 7: rail pressure calibration point 2 SKODA_INJ_7_RAIL_P_CAL_PT_2
- Request
22 14 73 - Service 22
DID 1473 - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2001 to 2026.
Injector 7: rail pressure calibration point 3 SKODA_INJ_7_RAIL_P_CAL_PT_3
- Request
22 14 79 - Service 22
DID 1479 - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2001 to 2026.
Inlet flaps - actual value SKODA_INLET_FLAPS_ACT
- Request
22 11 9D - Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Inlet flaps - requested value SKODA_INLET_FLAPS_REQ
- Request
22 11 A0 - Service 22
DID 11A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Inside temperature SKODA_INSIDE_T
- Request
22 26 13 - Service 22
DID 2613 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 50)- Range
- -50 to 6503 °C
- Unit
- °C
In testing for 2001 to 2026.
Intake air temperature SKODA_IAT_7E0
- Request
22 10 01 - Service 22
DID 1001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2001 to 2026.
Intake air temperature before throttle valve, raw value SKODA_IAT_BEFORE_THROTTLE
- Request
22 15 C1 - Service 22
DID 15C1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2001 to 2026.
Intake air temperature in intake manifold SKODA_INTAKE_AIR_T_IN_INTAKE_MANIFOLD
- Request
22 14 9E - Service 22
DID 149E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2001 to 2026.
Intake air temperature in intake manifold SKODA_INTAKE_AIR_T_IN_INTAKE_MANIFOLD_V2
- Request
22 14 9E - Service 22
DID 149E - Module
FC00 → FE0076 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2001 to 2026.
Intake air temperature in intake manifold raw value SKODA_IAT_INT_MANIFOLD_RAW
- Request
22 15 C0 - Service 22
DID 15C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2001 to 2026.
Intake air temperature raw value SKODA_IAT_RAW
- Request
22 15 C0 - Service 22
DID 15C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Intake camshaft adaptation unit 1 phase length SKODA_PQ35_CAMS_ADAPT_PHASE_1
- Request
22 12 FE - Service 22
DID 12FE - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft signal edge position adapted edge 2 SKODA_CAMS_EDGE_POS_2
- Request
22 11 89 - Service 22
DID 1189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft signal edge position adapted edge 2 SKODA_PQ35_CAMS_EDGE_POS_2
- Request
22 11 89 - Service 22
DID 1189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.9375 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft signal edge position adapted edge 3 SKODA_CAMS_EDGE_POS_3
- Request
22 11 8A - Service 22
DID 118A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft signal edge position adapted edge 3 SKODA_PQ35_CAMS_EDGE_POS_3
- Request
22 11 8A - Service 22
DID 118A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.9375 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft signal edge position adapted edge 4 SKODA_PQ35_CAMS_EDGE_POS_4
- Request
22 11 8B - Service 22
DID 118B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft signal edge position adapted edge 5 SKODA_PQ35_CAMS_EDGE_POS_5
- Request
22 11 8C - Service 22
DID 118C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft signal edge position adapted edge 6 SKODA_PQ35_CAMS_EDGE_POS_6
- Request
22 11 8D - Service 22
DID 118D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft signal edge position adapted edge 7 SKODA_PQ35_CAMS_EDGE_POS_7
- Request
22 11 8E - Service 22
DID 118E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft signal edge position adapted edge 8 SKODA_PQ35_CAMS_EDGE_POS_8
- Request
22 11 8F - Service 22
DID 118F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft signal edge position adapted value edge 1 SKODA_PQ35_INTAKE_CAMSHAFT_SIGNAL_EDGE_POS_ADAPTED_VALUE_EDGE_1
- Request
22 17 3A - Service 22
DID 173A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft, adaptation bias SKODA_INT_CAM_ADPT_BIAS
- Request
22 17 4B - Service 22
DID 174B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2001 to 2026.
Intake camshaft, adaptation sensor tolerance SKODA_INT_CAM_ADPT_SENS
- Request
22 17 40 - Service 22
DID 1740 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2001 to 2026.
Intake manifold pressure calculated SKODA_MQB_INT_MAN_P
- Request
22 10 3C - Service 22
DID 103C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Intake manifold pressure raw value SKODA_INT_MANIFOLD_P_RAW
- Request
22 11 DC - Service 22
DID 11DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 781.25 ÷ 10000)- Range
- 0 to 19.92
- Unit
- Raw value
In testing for 2001 to 2026.
Intake manifold pressure raw value SKODA_INT_MANIFOLD_P_RAW_V2
- Request
22 3E 70 - Service 22
DID 3E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2001 to 2026.
Intake manifold pressure, commanded SKODA_INT_MANIFOLD_P_CMD
- Request
22 11 DD - Service 22
DID 11DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2001 to 2026.
Intake manifold pressure, corrected SKODA_INT_MANIFOLD_P
- Request
22 11 DA - Service 22
DID 11DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2001 to 2026.
Intake manifold runner control, acknowledgment SKODA_INT_MANIFOLD_RUNNER_CTRL
- Request
22 20 6A - Service 22
DID 206A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Intake manifold runner control, activation SKODA_INT_MANIFOLD_RUNNER
- Request
22 20 69 - Service 22
DID 2069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Intake model air mass flow filtered value SKODA_INT_MODEL_AIR_MASS
- Request
22 11 AB - Service 22
DID 11AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2001 to 2026.
Intake phase deviation, actual value SKODA_INT_PHASE_DEV_ACT
- Request
22 18 00 - Service 22
DID 1800 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2001 to 2026.
Intake phase deviation, after chain replacement SKODA_INT_PHASE_DEV_AFTER
- Request
22 41 7B - Service 22
DID 417B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2001 to 2026.
Intake phase deviation, after repair SKODA_INT_PHASE_DEV_AFTER_REPAIR
- Request
22 41 7F - Service 22
DID 417F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2001 to 2026.
Intake timing chain extension, mileage since last adaptation SKODA_INT_TIM_CHAIN
- Request
22 51 6C - Service 22
DID 516C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2001 to 2026.
Integrated mass of air since engine start SKODA_INTEGRATED_MASS_AIR
- Request
22 11 75 - Service 22
DID 1175 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8889 ÷ 25000)- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2001 to 2026.
Integrated mass of air since the first engine start SKODA_INTEGRATED_MASS_AIR_SINCE
- Request
22 17 43 - Service 22
DID 1743 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8889 ÷ 25000)- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2001 to 2026.
Intercooler air output temperature SKODA_INTERCOOLER_AIR_T
- Request
22 16 28 - Service 22
DID 1628 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Intercooler air output temperature SKODA_PQ35_INTERCOOLER_AIR_OUTPUT_T
- Request
22 16 28 - Service 22
DID 1628 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Kick down SKODA_MQB_TCM_KICK_DOWN
- Request
22 21 14 - Service 22
DID 2114 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Kilometers driven since last event on K1 SKODA_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1
- Request
22 11 5A - Service 22
DID 115A - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 10)- Range
- 0 to 7000 km
- Unit
- km
In testing for 2001 to 2026.
Kilometers driven since last event on K2 SKODA_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2
- Request
22 11 5C - Service 22
DID 115C - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 10)- Range
- 0 to 7000 km
- Unit
- km
In testing for 2001 to 2026.
Knock retard 2 SKODA_KNOCK_RETARD_2
- Request
22 10 E6 - Service 22
DID 10E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2001 to 2026.
Knock retard 5 SKODA_KNOCK_RETARD_5
- Request
22 10 E7 - Service 22
DID 10E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2001 to 2026.
Knock retard:, cylinder 1 SKODA_KNOCK_RETARD_CYL_1
- Request
22 13 F2 - Service 22
DID 13F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2001 to 2026.
Knock retard:, cylinder 2 SKODA_KNOCK_RETARD_CYL_2
- Request
22 13 F3 - Service 22
DID 13F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2001 to 2026.
Knock retard:, cylinder 3 SKODA_KNOCK_RETARD_CYL_3
- Request
22 13 F4 - Service 22
DID 13F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2001 to 2026.
Knock retard:, cylinder 4 SKODA_KNOCK_RETARD_CYL_4
- Request
22 13 F5 - Service 22
DID 13F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2001 to 2026.
Knock retard:, cylinder 5 SKODA_KNOCK_RETARD_CYL_5
- Request
22 13 F6 - Service 22
DID 13F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2001 to 2026.
Knock retard:, cylinder 6 SKODA_KNOCK_RETARD_CYL_6
- Request
22 13 F7 - Service 22
DID 13F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2001 to 2026.
Knock sensor 1 test SKODA_KNOCK_SENS_1_TEST
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
Knock sensor 2 test SKODA_KNOCK_SENS_2_TEST
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
Knock sensor 3 test SKODA_KNOCK_SENS_3_TEST
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
Knock sensor 4 test SKODA_KNOCK_SENS_4_TEST
- Request
22 39 3C - Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
Knock sensor, cylinder 1 SKODA_KNOCK_SENS_CYL_1_V2
- Request
22 39 60 - Service 22
DID 3960 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2001 to 2026.
Knock sensor, cylinder 1 SKODA_KNOCK_SNS_C1_V_MS
- Request
22 12 0E - Service 22
DID 120E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2001 to 2026.
Knock sensor, cylinder 1 SKODA_KNOCK_SNS_C1_V_MS_V2
- Request
22 12 0E - Service 22
DID 120E - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2001 to 2026.
Knock sensor, cylinder 2 SKODA_KNOCK_SENS_CYL_2
- Request
22 12 12 - Service 22
DID 1212 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 7.62e-7)- Range
- 0 to 3272
- Unit
- Number
In testing for 2001 to 2026.
Knock sensor, cylinder 2 SKODA_KNOCK_SENS_CYL_2_V3
- Request
22 39 61 - Service 22
DID 3961 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2001 to 2026.
Knock sensor, cylinder 2 SKODA_KNOCK_SNS_C2_V_MS
- Request
22 12 11 - Service 22
DID 1211 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2001 to 2026.
Knock sensor, cylinder 2 SKODA_KNOCK_SNS_C2_V_MS_V2
- Request
22 12 11 - Service 22
DID 1211 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2001 to 2026.
Knock sensor, cylinder 3 SKODA_KNOCK_SENS_CYL_3_V3
- Request
22 39 62 - Service 22
DID 3962 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2001 to 2026.
Knock sensor, cylinder 3 SKODA_KNOCK_SNS_C3_V_MS
- Request
22 12 0F - Service 22
DID 120F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2001 to 2026.
Knock sensor, cylinder 3 SKODA_KNOCK_SNS_C3_V_MS_V2
- Request
22 12 0F - Service 22
DID 120F - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2001 to 2026.
Knock sensor, cylinder 4 SKODA_KNOCK_SENS_CYL_4_V3
- Request
22 39 63 - Service 22
DID 3963 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2001 to 2026.
Knock sensor, cylinder 4 SKODA_KNOCK_SNS_C4_V_MS
- Request
22 12 10 - Service 22
DID 1210 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2001 to 2026.
Knock sensor, cylinder 4 SKODA_KNOCK_SNS_C4_V_MS_V2
- Request
22 12 10 - Service 22
DID 1210 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0076294 ÷ 10000)- Range
- 0 to 3276
- Unit
- Number
In testing for 2001 to 2026.
Lambda output value SKODA_LAMBDA_OUTPUT
- Request
22 15 D4 - Service 22
DID 15D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 199997 ÷ 6553500000)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2001 to 2026.
Lambda value at DPF inlet SKODA_LAMBDA_DPF_INLET
- Request
22 08 0E - Service 22
DID 080E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -32.768 to 32.767
- Unit
- Number
In testing for 2001 to 2026.
Lambda, actual value SKODA_LAMBDA_ACT
- Request
22 10 D5 - Service 22
DID 10D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 50000000)- Range
- -7.9999 to 7.9997
- Unit
- Number
In testing for 2001 to 2026.
Launch control counter SKODA_LAUNCH_CTRL_CNT
- Request
22 38 F1 - Service 22
DID 38F1 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Launch control counter, variant 1 SKODA_LAUNCH_CTRL_CNT_VAR_1
- Request
22 12 00 - Service 22
DID 1200 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Left central air outlet temperature SKODA_LEFT_CENTRAL_AIR_T
- Request
22 42 C5 - Service 22
DID 42C5 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Left footwell air outlet temperature SKODA_LEFT_FOOTWELL_AIR_T
- Request
22 42 BC - Service 22
DID 42BC - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Left rear footwell air outlet temperature SKODA_LEFT_REAR_FOOTWELL_T
- Request
22 42 C1 - Service 22
DID 42C1 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Left rear upper air outlet temperature SKODA_LEFT_REAR_HI_AIR_T
- Request
22 42 BE - Service 22
DID 42BE - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Left side air outlet temperature SKODA_LEFT_SIDE_AIR_OUTLET_T
- Request
22 42 C3 - Service 22
DID 42C3 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Leg deflector temperature SKODA_CLIMATE_LEG_DEFL_T
- Request
22 26 11 - Service 22
DID 2611 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 3)- Range
- 0 to 84.915 °C
- Unit
- °C
In testing for 2001 to 2026.
Limitation, smoke SKODA_LIM_SMOKE
- Request
22 13 01 - Service 22
DID 1301 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Limitation, torque SKODA_LIM_TQ
- Request
22 10 6B - Service 22
DID 106B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Long term fuel trim at idle - direct injection SKODA_LONG_TERM_FUEL_TRIM_IDLE_V2
- Request
22 17 7E - Service 22
DID 177E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 3 ÷ 64)- Range
- -1536 to 1535 %
- Unit
- %
In testing for 2001 to 2026.
Long term fuel trim at idle - port injection SKODA_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ
- Request
22 17 80 - Service 22
DID 1780 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 3 ÷ 64)- Range
- -1536 to 1535 %
- Unit
- %
In testing for 2001 to 2026.
Long term throttle adaptation to MAF sensor SKODA_LONG_TERM_THROTTLE
- Request
22 11 3A - Service 22
DID 113A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0000610351)- Range
- 0 to 3.99 %
- Unit
- %
In testing for 2001 to 2026.
Long-term adaptation of intake manifold injection SKODA_LONG_TERM_ADPT_INT
- Request
22 41 4E - Service 22
DID 414E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Long-term adaptation of intake manifold injection at idle SKODA_LONG_TERM_ADPT_INT_MANIFOLD_INJ
- Request
22 41 4F - Service 22
DID 414F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Lost torque adaptation A/C + driving mode SKODA_LOST_TQ_ADPT_AC
- Request
22 43 7F - Service 22
DID 437F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Lost torque adaptation driving mode SKODA_LOST_TQ_ADPT_DRIVING
- Request
22 43 7E - Service 22
DID 437E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Low press. EGR closing SKODA_LOW_PRESS_EGR
- Request
22 13 14 - Service 22
DID 1314 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 25 ÷ 2048)- Range
- 0 to 799 %
- Unit
- %
In testing for 2001 to 2026.
Low press. EGR closing SKODA_LOW_PRESS_EGR_V2
- Request
22 40 6B - Service 22
DID 406B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Low pressure EGR closing SKODA_LOW_P_EGR_CLOSING
- Request
22 17 F4 - Service 22
DID 17F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × -25 ÷ 2048 + 100)- Range
- -699 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Lower adapted coupling point K2 from micro-slip path adaptation SKODA_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPT
- Request
22 11 0A - Service 22
DID 110A - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5)- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2001 to 2026.
M009, desired solenoid out 10 SKODA_M009_DES_SOLENOID_10
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
M009, desired solenoid out 11 SKODA_M009_DES_SOLENOID_11
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
M009, desired solenoid out 12 SKODA_M009_DES_SOLENOID_12
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
M009, desired solenoid out 13 SKODA_M009_DES_SOLENOID_13
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
M009, desired solenoid out 14 SKODA_M009_DES_SOLENOID_14
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
Main cat oxygen storage capacity age correction factor SKODA_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR
- Request
22 14 F9 - Service 22
DID 14F9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2001 to 2026.
Main catalytic converter oxygen storage capacity age correction factor SKODA_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR_V2
- Request
22 14 F9 - Service 22
DID 14F9 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2001 to 2026.
Main injection duration SKODA_PQ35_MAIN_INJ_DURATION
- Request
22 14 CF - Service 22
DID 14CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2001 to 2026.
Main injection start position SKODA_PQ35_MAIN_INJ_START
- Request
22 11 F2 - Service 22
DID 11F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2001 to 2026.
Main injection, duration SKODA_MAIN_INJ_DUR
- Request
22 14 CF - Service 22
DID 14CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2500)- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 2001 to 2026.
Main injection, start SKODA_MAIN_INJ_START
- Request
22 11 F2 - Service 22
DID 11F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 °
- Unit
- °
In testing for 2001 to 2026.
Manifold absolute pressure, raw value SKODA_MAP_RAW
- Request
22 11 DC - Service 22
DID 11DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2001 to 2026.
Manual engine starts counter SKODA_MANUAL_ENG_STARTS
- Request
22 29 98 - Service 22
DID 2998 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Mass air flow over throttle valve SKODA_MAF_OVER_THROTTLE
- Request
22 39 4F - Service 22
DID 394F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2001 to 2026.
Mass air flow through throttle SKODA_MAF_THROUGH_THROTTLE
- Request
22 11 AC - Service 22
DID 11AC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2001 to 2026.
Mass air flow, commanded SKODA_MAF_CMD
- Request
22 11 AD - Service 22
DID 11AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2001 to 2026.
Mass airflow sensor 1 bank 1 raw value SKODA_MAF_1_B1_RAW
- Request
22 10 26 - Service 22
DID 1026 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2001 to 2026.
Mass flow through throttle valve SKODA_MASS_FLOW_THROUGH
- Request
22 11 0A - Service 22
DID 110A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2001 to 2026.
Max permissible engine torque SKODA_MAX_PERMISSIBLE_ENG
- Request
22 21 1A - Service 22
DID 211A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Maximum ECU temperature SKODA_MAX_ECU_T
- Request
22 46 49 - Service 22
DID 4649 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Maximum filling correction factor from knock control SKODA_MAX_FILLING_CORR
- Request
22 10 E9 - Service 22
DID 10E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 3 ÷ 100000)- Range
- 0 to 1.96
- Unit
- Number
In testing for 2001 to 2026.
Maximum oil level for the service interval SKODA_MAX_OIL_LEVEL
- Request
22 12 30 - Service 22
DID 1230 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2001 to 2026.
Mean engine air mass SKODA_MEAN_ENG_AIR_MASS
- Request
22 20 32 - Service 22
DID 2032 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2001 to 2026.
Mean engine air mass SKODA_PQ35_MEAN_AIR_MASS
- Request
22 13 14 - Service 22
DID 1314 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968
- Unit
- Raw value
In testing for 2001 to 2026.
Mean injection quantity SKODA_MEAN_INJ_QTY
- Request
22 20 97 - Service 22
DID 2097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2001 to 2026.
Mean injection quantity SKODA_MEAN_INJ_QUANTITY
- Request
22 11 39 - Service 22
DID 1139 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Median injection timing SKODA_MEDIAN_INJ_TIM
- Request
22 12 8C - Service 22
DID 128C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2001 to 2026.
Mileage with ECU installed SKODA_MILEAGE_ECU
- Request
22 10 A2 - Service 22
DID 10A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2001 to 2026.
Minimum oil level for the service interval SKODA_MIN_OIL_LEVEL
- Request
22 12 31 - Service 22
DID 1231 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2001 to 2026.
Misfires / 1000 revolutions, cylinder 1 SKODA_MISFIRES_1000REV_C1
- Request
22 11 47 - Service 22
DID 1147 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires / 1000 revolutions, cylinder 2 SKODA_MISFIRES_1000REV_C2
- Request
22 11 4A - Service 22
DID 114A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires / 1000 revolutions, cylinder 3 SKODA_PQ35_FUEL_METER
- Request
22 11 48 - Service 22
DID 1148 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires / 1000 revolutions, cylinder 4 SKODA_PQ35_BOOST_P_CMD
- Request
22 11 49 - Service 22
DID 1149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires counter:, cylinder 1 SKODA_MIS_CNT_1
- Request
22 14 7E - Service 22
DID 147E - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires counter:, cylinder 2 SKODA_MIS_CNT_2
- Request
22 14 82 - Service 22
DID 1482 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires counter:, cylinder 3 SKODA_MIS_CNT_3
- Request
22 14 80 - Service 22
DID 1480 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires counter:, cylinder 4 SKODA_MIS_CNT_4
- Request
22 14 7F - Service 22
DID 147F - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires counter:, cylinder 5 SKODA_MIS_CNT_5
- Request
22 14 83 - Service 22
DID 1483 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires counter:, cylinder 6 SKODA_MIS_CNT_6
- Request
22 14 81 - Service 22
DID 1481 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires for 1000 revolutions, cylinder 1 SKODA_MIS_1000_REVOLUTIONS_1
- Request
22 29 1D - Service 22
DID 291D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires for 1000 revolutions, cylinder 2 SKODA_MIS_1000_REVOLUTIONS_2
- Request
22 11 4B - Service 22
DID 114B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires for 1000 revolutions, cylinder 2 SKODA_MIS_1000_REVOLUTIONS_2_V2
- Request
22 29 20 - Service 22
DID 2920 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires for 1000 revolutions, cylinder 3 SKODA_MIS_1000_REVOLUTIONS_3
- Request
22 29 1E - Service 22
DID 291E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires for 1000 revolutions, cylinder 4 SKODA_MIS_1000_REVOLUTIONS_4
- Request
22 29 1F - Service 22
DID 291F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires for 1000 revolutions, cylinder 5 SKODA_MIS_1000_REVOLUTIONS_5
- Request
22 11 4C - Service 22
DID 114C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires per 1000 revolutions, cylinder 1, port injection SKODA_MIS_PER_1000_1
- Request
22 42 6B - Service 22
DID 426B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires per 1000 revolutions, cylinder 2 SKODA_MIS_PER_1000_2
- Request
22 10 F6 - Service 22
DID 10F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires per 1000 revolutions, cylinder 2, port injection SKODA_MIS_PER_1000_2_V2
- Request
22 42 6C - Service 22
DID 426C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires per 1000 revolutions, cylinder 3 SKODA_MIS_PER_1000_3
- Request
22 10 F4 - Service 22
DID 10F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires per 1000 revolutions, cylinder 3, port injection SKODA_MIS_PER_1000_3_V2
- Request
22 42 6D - Service 22
DID 426D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires per 1000 revolutions, cylinder 4, port injection SKODA_MIS_PER_1000_4
- Request
22 42 6E - Service 22
DID 426E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires total SKODA_MIS_TOT
- Request
22 29 04 - Service 22
DID 2904 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires total SKODA_MISFIRES_TOTAL
- Request
22 11 46 - Service 22
DID 1146 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 1 SKODA_MIS_1
- Request
22 10 F7 - Service 22
DID 10F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 1 SKODA_MIS_1_V2
- Request
22 29 66 - Service 22
DID 2966 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 1 SKODA_MISFIRES_C1_FC00
- Request
22 29 66 - Service 22
DID 2966 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 2 SKODA_MIS_2
- Request
22 10 FA - Service 22
DID 10FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 2 SKODA_MIS_2_V2
- Request
22 29 69 - Service 22
DID 2969 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 2 SKODA_MISFIRES_C2_V2
- Request
22 29 69 - Service 22
DID 2969 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 3 SKODA_MIS_3
- Request
22 10 F8 - Service 22
DID 10F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 3 SKODA_MIS_3_V2
- Request
22 29 67 - Service 22
DID 2967 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 3 SKODA_MISFIRES_C3_ECM
- Request
22 11 50 - Service 22
DID 1150 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 3 SKODA_MISFIRES_C3_FC00
- Request
22 29 67 - Service 22
DID 2967 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 4 SKODA_MIS_4
- Request
22 10 F5 - Service 22
DID 10F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 4 SKODA_MIS_4_V2
- Request
22 29 68 - Service 22
DID 2968 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Misfires, cylinder 4 SKODA_MISFIRES_C4_V2
- Request
22 29 68 - Service 22
DID 2968 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Mixture adaptation factor at partial load SKODA_MIXTURE_ADPT_FACTOR
- Request
22 39 96 - Service 22
DID 3996 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Motor temperature SKODA_DIFF_MOTOR_T
- Request
22 F1 05 - Service 22
DID F105 - Module
71E → 788 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 50)- Range
- -50 to 460 °C
- Unit
- °C
In testing for 2001 to 2026.
N_32 SKODA_N_32
- Request
22 11 7D - Service 22
DID 117D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 32)- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2001 to 2026.
NL_PRE, 0 SKODA_NL_PRE_0
- Request
22 13 F6 - Service 22
DID 13F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38147 ÷ 500000000)- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2001 to 2026.
NL_PRE, 1 SKODA_NL_PRE_1
- Request
22 13 F7 - Service 22
DID 13F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38147 ÷ 500000000)- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2001 to 2026.
NL_PRE, 2 SKODA_NL_PRE_2
- Request
22 13 F8 - Service 22
DID 13F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38147 ÷ 500000000)- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2001 to 2026.
NL_PRE, 3 SKODA_NL_PRE_3
- Request
22 13 F9 - Service 22
DID 13F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38147 ÷ 500000000)- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2001 to 2026.
Number of injections SKODA_NUM_INJECTIONS
- Request
22 43 0E - Service 22
DID 430E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Number of times the permitted centrifugal oil temperature has been exceeded SKODA_NUM_TIMES_PERMITTED_T
- Request
22 11 54 - Service 22
DID 1154 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Number of warnings due to increased centrifugal oil temperature SKODA_NUM_WARN_HI_CENTRIF_T
- Request
22 11 55 - Service 22
DID 1155 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
NV energy requirement SKODA_NV_ENERGY
- Request
22 15 12 - Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 kWh
- Unit
- kWh
In testing for 2001 to 2026.
Oil ash limit SKODA_OIL_ASH_LIM
- Request
22 17 93 - Service 22
DID 1793 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Oil ash residue SKODA_OIL_ASH_RESIDUE
- Request
22 17 8C - Service 22
DID 178C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2001 to 2026.
Oil ash residue SKODA_OIL_ASH_RESIDUE_V2
- Request
22 20 8A - Service 22
DID 208A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 3.052e-7)- Range
- 0 to 1310
- Unit
- Raw value
In testing for 2001 to 2026.
Oil dynamic average SKODA_OIL_DYNAMIC_AVG
- Request
22 12 3F - Service 22
DID 123F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil dynamic average measurement SKODA_PQ35_OIL_DYN_AVG
- Request
22 12 3F - Service 22
DID 123F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil fill level SKODA_OIL_FILL_LEVEL
- Request
22 20 06 - Service 22
DID 2006 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.06)- Range
- -1966.08 to 1966.02 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil last dynamic measurement SKODA_PQ35_OIL_DYN_LAST
- Request
22 12 3C - Service 22
DID 123C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil last dynamic value SKODA_OIL_LAST_DYNAMIC
- Request
22 12 3C - Service 22
DID 123C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil level SKODA_OIL_LEVEL
- Request
22 11 BA - Service 22
DID 11BA - Module
7E0 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262
- Unit
- Raw value
In testing for 2001 to 2026.
Oil level SKODA_OIL_LVL
- Request
22 11 BA - Service 22
DID 11BA - Module
7E0 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2500)- Range
- 0 to 26.2 cm
- Unit
- cm
In testing for 2001 to 2026.
Oil level method 1 SKODA_OIL_LEVEL_METHOD_1
- Request
22 1A F9 - Service 22
DID 1AF9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2001 to 2026.
Oil level method 2 SKODA_OIL_LEVEL_METHOD_2
- Request
22 1A FA - Service 22
DID 1AFA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2001 to 2026.
Oil level method 3 SKODA_OIL_LEVEL_METHOD_3
- Request
22 1A FB - Service 22
DID 1AFB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2001 to 2026.
Oil level test method 1 SKODA_OIL_LEVEL_TEST_1
- Request
22 4E 51 - Service 22
DID 4E51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Oil level test method 2 SKODA_OIL_LEVEL_TEST_2
- Request
22 4E 52 - Service 22
DID 4E52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Oil level test method 3 SKODA_OIL_LEVEL_TEST_3
- Request
22 4E 53 - Service 22
DID 4E53 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Oil level, average dynamic value SKODA_OIL_LEVEL_AVG
- Request
22 15 B9 - Service 22
DID 15B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil level, last dynamic value SKODA_OIL_LEVEL_LAST
- Request
22 15 B8 - Service 22
DID 15B8 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil level, last valid dynamic value SKODA_OIL_LEVEL_LAST_VALID
- Request
22 10 F3 - Service 22
DID 10F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 127)- Range
- -127 to 3968 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil level, static measured SKODA_OIL_LEVEL_STATIC_V2
- Request
22 15 A4 - Service 22
DID 15A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil level, static measurement SKODA_OIL_LEVEL_STATIC
- Request
22 40 CE - Service 22
DID 40CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 127)- Range
- -127 to 3968 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil maximum level SKODA_PQ35_OIL_LVL_MAX
- Request
22 11 C4 - Service 22
DID 11C4 - Module
7E0 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil minimum level SKODA_PQ35_OIL_LVL_MIN
- Request
22 11 C5 - Service 22
DID 11C5 - Module
7E0 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2001 to 2026.
Oil p SKODA_OIL_P
- Request
22 25 CD - Service 22
DID 25CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2001 to 2026.
Oil pressure 1 SKODA_OIL_P_1
- Request
22 2B 05 - Service 22
DID 2B05 - Module
71D → 787 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 bar
- Unit
- bar
In testing for 2001 to 2026.
Oil pressure 2 SKODA_OIL_P_2
- Request
22 2B 06 - Service 22
DID 2B06 - Module
71D → 787 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 bar
- Unit
- bar
In testing for 2001 to 2026.
Oil pressure actual SKODA_MQB_TCM_EOP_ACTUAL
- Request
22 38 1D - Service 22
DID 381D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2001 to 2026.
Oil pressure actual current SKODA_MQB_TCM_EOP_ACTUAL_I
- Request
22 38 1E - Service 22
DID 381E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2001 to 2026.
Oil pressure control valve activation pulse duty factor SKODA_OIL_P_CTRL_VLV
- Request
22 25 D0 - Service 22
DID 25D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Oil pressure control valve, activation pulse duty factor SKODA_OIL_P_CTRL_VLV_ACTIVATION
- Request
22 4F 97 - Service 22
DID 4F97 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Oil pressure sensor raw value SKODA_OIL_P_SENS_RAW_V2
- Request
22 4F BE - Service 22
DID 4FBE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 2001 to 2026.
Oil pressure sensor-piston cooling nozzle switch, status SKODA_OIL_P_SENS_PISTON
- Request
22 15 BD - Service 22
DID 15BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Oil pressure sensor, raw value SKODA_OIL_P_SENS_RAW
- Request
22 1B 02 - Service 22
DID 1B02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Oil pressure switch activation, high pressure SKODA_OIL_P_SWITCH_P
- Request
22 20 A2 - Service 22
DID 20A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Oil pressure switch for high pressure, closed SKODA_OIL_P_SWITCH_HIGH_P
- Request
22 20 A3 - Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
Oil pressure switch for low pressure, closed SKODA_OIL_P_SWITCH_LOW_P
- Request
22 20 A3 - Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2026.
Oil pressure switch for piston-cooling jets, closed SKODA_OIL_P_SWITCH_PISTON
- Request
22 42 70 - Service 22
DID 4270 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Oil pressure switch valve activation SKODA_OIL_P_SWITCH_VLV
- Request
22 13 B8 - Service 22
DID 13B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Oil pressure target SKODA_OIL_P_TGT
- Request
22 25 CF - Service 22
DID 25CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2001 to 2026.
Oil pressure target SKODA_OIL_P_TGT_7E0
- Request
22 4F 70 - Service 22
DID 4F70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2001 to 2026.
Oil pressure target SKODA_OIL_P_TGT_V2
- Request
22 4F 70 - Service 22
DID 4F70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 2001 to 2026.
Oil pressure valve for piston cooling nozzles, control switch button ratio SKODA_OIL_P_VLV_PISTON
- Request
22 2C D8 - Service 22
DID 2CD8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Oil pressure valve switch, control SKODA_OIL_P_VLV_SWITCH
- Request
22 11 B9 - Service 22
DID 11B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Oil pressure, actual value SKODA_OIL_P_ACT
- Request
22 17 7D - Service 22
DID 177D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2001 to 2026.
Oil pressure, actual value SKODA_OIL_P_ACT_7E0_2
- Request
22 38 1D - Service 22
DID 381D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2001 to 2026.
Oil pressure, actual value SKODA_OIL_P_ACT_7E0_2_V2
- Request
22 1B 04 - Service 22
DID 1B04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Oil sensor temperature 1 SKODA_OIL_SENS_T_1
- Request
22 2B 03 - Service 22
DID 2B03 - Module
71D → 787 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
Oil sensor temperature 2 SKODA_OIL_SENS_T_2
- Request
22 2B 04 - Service 22
DID 2B04 - Module
71D → 787 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
Oil sump temperature SKODA_OIL_SUMP_T
- Request
22 15 B7 - Service 22
DID 15B7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Oil temp 2 SKODA_ENGINE_OIL_T_2
- Request
22 17 9C - Service 22
DID 179C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Oil temperature SKODA_DIFF_OIL_T
- Request
22 F1 05 - Service 22
DID F105 - Module
71E → 788 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 2 − 50)- Range
- -50 to 460 °C
- Unit
- °C
In testing for 2001 to 2026.
Oil temperature SKODA_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 10 A7 - Service 22
DID 10A7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Oil temperature SKODA_PQ35_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 20 2F - Service 22
DID 202F - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 58)- Range
- -58 to 197 °C
- Unit
- °C
In testing for 2001 to 2026.
Oil temperature variant SKODA_PQ35_OIL_T_2
- Request
22 11 BE - Service 22
DID 11BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Oil temperature variant SKODA_PQ46_OIL_T_2
Pelican can show this parameter as the engine oil temperature.
- Request
22 11 BE - Service 22
DID 11BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 300 °C
- Unit
- °C
In testing for 2001 to 2026.
Oil thermal wear SKODA_DASH_OIL_THERMAL_WEAR
- Request
22 22 4B - Service 22
DID 224B - Module
714 → 77E - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2001 to 2026.
Oil warning threshold SKODA_OIL_WARN_THR
- Request
22 20 07 - Service 22
DID 2007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 mm
- Unit
- mm
In testing for 2001 to 2026.
Open cam shaft angle at quantity control valve SKODA_OPEN_CAM_SHFT_ANG
- Request
22 10 EA - Service 22
DID 10EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2001 to 2026.
Open camshaft angle at quantity control valve SKODA_OPEN_CAM_ANG_QTY
- Request
22 10 E1 - Service 22
DID 10E1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2001 to 2026.
Outside temperature SKODA_OUTSIDE_T
- Request
22 22 0C - Service 22
DID 220C - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 50)- Range
- -50 to 77.5 °C
- Unit
- °C
In testing for 2001 to 2026.
Outside temperature, system calculated SKODA_OUTSIDE_T_SYSTEM
- Request
22 26 0A - Service 22
DID 260A - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Outside temperature, system calculated SKODA_TRON_OUTSIDE_T_SYSTEM
- Request
22 26 0A - Service 22
DID 260A - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -64 to 63.5 °C
- Unit
- °C
In testing for 2001 to 2026.
Overall energy balance SKODA_OVERALL_ENERGY
- Request
22 2A 17 - Service 22
DID 2A17 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The value is signed.
- Formula
(val × 21 ÷ 20)- Range
- -8808038 to 8808037 Ah
- Unit
- Ah
In testing for 2001 to 2026.
Oxygen control, adaptation value at part. load SKODA_OXYGEN_CTRL_ADPT
- Request
22 39 A9 - Service 22
DID 39A9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Oxygen sensor 1 bank 1 ceramic temperature SKODA_OXYGEN_SNS_1_BANK_1_CERAMIC_T
- Request
22 12 90 - Service 22
DID 1290 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 234.37 ÷ 10000 − 273.15)- Range
- -273.15 to 1262.793 °C
- Unit
- °C
In testing for 2001 to 2026.
Oxygen sensor 1 bank 1 ceramic temperature SKODA_OXYGEN_SNS_1_BANK_1_CERAMIC_T_V2
- Request
22 12 90 - Service 22
DID 1290 - Module
FC00 → FE0076 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 234.37 ÷ 10000 − 273.15)- Range
- -273.15 to 1262 °C
- Unit
- °C
In testing for 2001 to 2026.
Oxygen sensor 1 bank 1 lambda value SKODA_PQ35_O2_SEN_1_LAMBDA
- Request
22 11 3D - Service 22
DID 113D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Number
In testing for 2001 to 2026.
Particle filter, field regeneration request status SKODA_PARTICLE_FLT_FIELD
- Request
22 11 5B - Service 22
DID 115B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Particle sensor, cleaning deviation reaction time SKODA_PARTICLE_SENS
- Request
22 44 F5 - Service 22
DID 44F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -32.76 to 32.76
- Unit
- Number
In testing for 2001 to 2026.
Particle sensor, exhaust temperature SKODA_PARTICLE_SENS_EXH_T
- Request
22 44 F8 - Service 22
DID 44F8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2001 to 2026.
Particle sensor, soot volume in exhaust SKODA_PARTICLE_SENS_SOOT
- Request
22 44 F7 - Service 22
DID 44F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2001 to 2026.
Particle sensor, surface temperature SKODA_PARTICLE_SENS_T
- Request
22 44 FB - Service 22
DID 44FB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16 − 273.15)- Range
- -2321 to 1774 °C
- Unit
- °C
In testing for 2001 to 2026.
Particle sensor, time in op.mode measurement SKODA_PARTICLE_SENS_TIME
- Request
22 46 D4 - Service 22
DID 46D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 s
- Unit
- s
In testing for 2001 to 2026.
Particulate filter air pressure sensor raw value SKODA_MQB_DPF_AIR_P_SENSOR_RAW_VALUE
- Request
22 16 2F - Service 22
DID 162F - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Particulate filter differential pressure, dynamic offset SKODA_DPF_DIFF_P_DYNAMIC_OFFSET
- Request
22 15 B8 - Service 22
DID 15B8 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Particulate filter differential pressure, filtered SKODA_PF_DIFF_P_FILTERED
- Request
22 10 40 - Service 22
DID 1040 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 5000)- Range
- -5000 to 11383.75
- Unit
- Raw value
In testing for 2001 to 2026.
Pilot injection 1 duration SKODA_PQ35_PRE_INJ_1_DURATION
- Request
22 14 D0 - Service 22
DID 14D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2001 to 2026.
Pilot injection 1 start position SKODA_PQ35_PRE_INJ_1_START
- Request
22 14 C7 - Service 22
DID 14C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2001 to 2026.
Pilot injection 2 start SKODA_PQ35_PRE_INJ_2_START
- Request
22 14 C8 - Service 22
DID 14C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2001 to 2026.
Pilot injection 3 start SKODA_PRE_INJ_3_START
- Request
22 16 31 - Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 21973 ÷ 1000000)- Range
- -720 to 719 °
- Unit
- °
In testing for 2001 to 2026.
Piston cooling nozzles, control SKODA_PISTON_COOLING
- Request
22 16 F4 - Service 22
DID 16F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Piston-cooling jets, activation SKODA_PISTON_COOLING_JETS
- Request
22 42 86 - Service 22
DID 4286 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Port injection injections counter SKODA_PORT_INJ_INJECTIONS
- Request
22 42 68 - Service 22
DID 4268 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2001 to 2026.
Post injection 1 SKODA_POST_INJ_1
- Request
22 08 1A - Service 22
DID 081A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2001 to 2026.
Post injection 1 SKODA_POST_INJ_1_7E0
- Request
22 20 5D - Service 22
DID 205D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2001 to 2026.
Post injection 1, quantity specified value SKODA_POST_INJ_1_QTY_SPEC
- Request
22 16 3C - Service 22
DID 163C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655
- Unit
- Raw value
In testing for 2001 to 2026.
Post injection 1: quantity specified value SKODA_PQ35_POST_INJ_1_QTY_SPEC
- Request
22 16 3C - Service 22
DID 163C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2001 to 2026.
Post injection 2 SKODA_POST_INJ_2_7E0
- Request
22 20 5F - Service 22
DID 205F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2001 to 2026.
Post injection 2 SKODA_POST_INJ_2_V2
- Request
22 08 0C - Service 22
DID 080C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2001 to 2026.
Post injection 2, quantity specified value SKODA_POST_INJ_2_QTY_SPEC
- Request
22 16 3B - Service 22
DID 163B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655
- Unit
- Raw value
In testing for 2001 to 2026.
Post injection 2: quantity specified value SKODA_PQ35_POST_INJ_2_QTY_SPEC
- Request
22 16 3B - Service 22
DID 163B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2001 to 2026.
Post injection 3 SKODA_POST_INJ_3_7E0
- Request
22 20 C0 - Service 22
DID 20C0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2001 to 2026.
Post injection 3 SKODA_POST_INJ_3_V2
- Request
22 08 1B - Service 22
DID 081B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2001 to 2026.
Post injection 3, quantity specified value SKODA_POST_INJ_3_QTY_SPEC
- Request
22 16 7D - Service 22
DID 167D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655
- Unit
- Raw value
In testing for 2001 to 2026.
Post injection 3: quantity specified value SKODA_PQ35_POST_INJ_3_QTY_SPEC
- Request
22 16 7D - Service 22
DID 167D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2001 to 2026.
Post-injection 1 duration SKODA_PQ35_POST_INJ_1_DURATION
- Request
22 14 CC - Service 22
DID 14CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2001 to 2026.
Post-injection 1 start position SKODA_PQ35_POST_INJ_1_START
- Request
22 11 F4 - Service 22
DID 11F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2001 to 2026.
Post-injection 1, duration SKODA_POST_INJ_1_DUR
- Request
22 14 CC - Service 22
DID 14CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2500)- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 2001 to 2026.
Post-injection 1, start SKODA_POST_INJ_1_START
- Request
22 11 F4 - Service 22
DID 11F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 °
- Unit
- °
In testing for 2001 to 2026.
Post-injection 2 duration SKODA_PQ35_POST_INJ_2_DURATION
- Request
22 14 CD - Service 22
DID 14CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2001 to 2026.
Post-injection 2 start position SKODA_PQ35_POST_INJ_2_START
- Request
22 11 F3 - Service 22
DID 11F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2001 to 2026.
Post-injection 2, activation duration SKODA_POST_INJ_2
- Request
22 12 1B - Service 22
DID 121B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2500)- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 2001 to 2026.
Post-injection 2, duration SKODA_POST_INJ_2_DUR
- Request
22 14 CD - Service 22
DID 14CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2500)- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 2001 to 2026.
Post-injection 2, start SKODA_POST_INJ_2_START
- Request
22 11 F3 - Service 22
DID 11F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 °
- Unit
- °
In testing for 2001 to 2026.
Post-injection 3 activation duration SKODA_POST_INJ_3_ACTIVATION_DURATION
- Request
22 14 CE - Service 22
DID 14CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2001 to 2026.
Post-injection 3 start position SKODA_PQ35_POST_INJ_3_START
- Request
22 11 31 - Service 22
DID 1131 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2001 to 2026.
Post-injection 3, activation start SKODA_POST_INJ_3
- Request
22 11 31 - Service 22
DID 1131 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 °
- Unit
- °
In testing for 2001 to 2026.
Power electronics internal supply voltage 1 SKODA_PE_SUPPLY_V1
- Request
22 46 6C - Service 22
DID 466C - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2001 to 2026.
Power electronics internal supply voltage 2 SKODA_PE_SUPPLY_V2
- Request
22 46 6B - Service 22
DID 466B - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2001 to 2026.
Power electronics link voltage SKODA_PE_LINK_V
- Request
22 3E 93 - Service 22
DID 3E93 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2001 to 2026.
Power electronics link voltage setpoint SKODA_PE_LINK_V_SET
- Request
22 3E ED - Service 22
DID 3EED - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2001 to 2026.
Power electronics phase U transistor temperature SKODA_PE_IGBT_U_T
- Request
22 46 64 - Service 22
DID 4664 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2001 to 2026.
Power electronics phase V transistor temperature SKODA_PE_IGBT_V_T
- Request
22 46 63 - Service 22
DID 4663 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2001 to 2026.
Power electronics phase W transistor temperature SKODA_PE_IGBT_W_T
- Request
22 46 62 - Service 22
DID 4662 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2001 to 2026.
Power electronics traction voltage SKODA_PE_HV_V
- Request
22 46 75 - Service 22
DID 4675 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2001 to 2026.
Power electronics transistor supply voltage SKODA_PE_IGBT_SUPPLY_V
- Request
22 46 5A - Service 22
DID 465A - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 V
- Unit
- V
In testing for 2001 to 2026.
Pre-injection 1, activation start SKODA_PRE_INJ_1_ACTIVATION
- Request
22 12 C8 - Service 22
DID 12C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 °
- Unit
- °
In testing for 2001 to 2026.
Pre-injection 2, activation start SKODA_PRE_INJ_2_ACTIVATION
- Request
22 12 C7 - Service 22
DID 12C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 °
- Unit
- °
In testing for 2001 to 2026.
Pre-injection 3, activation duration SKODA_PRE_INJ_3_ACTIVATION
- Request
22 12 1A - Service 22
DID 121A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2500)- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 2001 to 2026.
Pre-injection 3, activation start SKODA_PRE_INJ_3_ACTIVATION_START
- Request
22 12 1D - Service 22
DID 121D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 °
- Unit
- °
In testing for 2001 to 2026.
Preheat time SKODA_PREHEAT_TIME
- Request
22 11 1F - Service 22
DID 111F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100)- Range
- -3276800 to 3276700 ms
- Unit
- ms
In testing for 2001 to 2026.
Pressure before throttle valve - actual value SKODA_P_BEFORE_THROTTLE_ACT
- Request
22 11 EE - Service 22
DID 11EE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2001 to 2026.
Pressure before throttle valve - sensor measured SKODA_P_BEFORE_THROTTLE
- Request
22 11 EF - Service 22
DID 11EF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 21333 ÷ 546125)- Range
- 0 to 2559.96
- Unit
- Raw value
In testing for 2001 to 2026.
Pressure sensor 1 temperature SKODA_P_SENS_1_T
- Request
22 13 2A - Service 22
DID 132A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2001 to 2026.
Pressure sensor 2 temperature SKODA_P_SENS_2_T
- Request
22 13 2B - Service 22
DID 132B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2001 to 2026.
Pressure supply actual pressure SKODA_MQB_DQ200_P_SUPPLY_ACTUAL_P
- Request
22 11 91 - Service 22
DID 1191 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2001 to 2026.
Pressure supply actual pressure analog digital value SKODA_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE
- Request
22 10 2D - Service 22
DID 102D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_1 SKODA_PSN_EDGE_REL_AD_CAM_1
- Request
22 11 84 - Service 22
DID 1184 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2001 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_2 SKODA_PSN_EDGE_REL_AD_CAM_2
- Request
22 11 85 - Service 22
DID 1185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2001 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_IN_1 SKODA_PSN_EDGE_REL_AD_CAM_SAVE_1
- Request
22 11 86 - Service 22
DID 1186 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2001 to 2026.
Radiator fan 1, commanded duty SKODA_RADIATOR_FAN_1_CMD
- Request
22 10 9E - Service 22
DID 109E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Radiator fan 2, commanded duty SKODA_RADIATOR_FAN_2_CMD
- Request
22 10 9C - Service 22
DID 109C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
Radiator fan actual duty SKODA_CLIMATE_RAD_FAN_ACT_DUTY
- Request
22 26 06 - Service 22
DID 2606 - Module
746 → 7B0 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.5)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Radiator fan commanded duty SKODA_CLIMATE_RAD_FAN_CMD_DUTY
- Request
22 26 07 - Service 22
DID 2607 - Module
746 → 7B0 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.5)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Radiator fan duty SKODA_RADIATOR_FAN_DUTY
- Request
22 20 55 - Service 22
DID 2055 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Radiator outlet coolant temperature commanded SKODA_PQ35_RAD_COOL_T_CMD
- Request
22 11 11 - Service 22
DID 1111 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Radiator output coolant temp: actual SKODA_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUAL
- Request
22 16 26 - Service 22
DID 1626 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2001 to 2026.
Radiator output coolant temperature, actual SKODA_RADIATOR_OUTPUT_ECT_ACT
- Request
22 16 26 - Service 22
DID 1626 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Radiator output coolant temperature, commanded SKODA_RADIATOR_OUTPUT_ECT_CMD
- Request
22 11 11 - Service 22
DID 1111 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Rated drive torque SKODA_RATED_DRIVE_TQ
- Request
22 14 A1 - Service 22
DID 14A1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Reached maximum temperature SKODA_REACHED_MAXIMUM_T
- Request
22 11 17 - Service 22
DID 1117 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2001 to 2026.
Rear cat converter temperature, main catalytic converter model value SKODA_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE
- Request
22 12 72 - Service 22
DID 1272 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Rear catalytic converter temperature, main catalytic converter model value SKODA_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE_V2
- Request
22 12 72 - Service 22
DID 1272 - Module
FC00 → FE0076 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2001 to 2026.
Rear deflector temperature SKODA_CLIMATE_RR_DEFL_T
- Request
22 26 3D - Service 22
DID 263D - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 3)- Range
- 0 to 84.915 °C
- Unit
- °C
In testing for 2001 to 2026.
Reducing agent tank volume, act. value filtered SKODA_REDUCING_AGENT_TANK_ACT
- Request
22 1A 6C - Service 22
DID 1A6C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131 L
- Unit
- L
In testing for 2001 to 2026.
Refrigerant pressure SKODA_CLIMATE_REFRIG_P
- Request
22 26 05 - Service 22
DID 2605 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 bar
- Unit
- bar
In testing for 2001 to 2026.
Refrigerant pressure SKODA_REFRIGERANT_P
- Request
22 26 05 - Service 22
DID 2605 - Module
70E → 778 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 bar
- Unit
- bar
In testing for 2001 to 2026.
Regen. duration SKODA_REGEN_DUR
- Request
22 13 47 - Service 22
DID 1347 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 6000)- Range
- 0 to 715827 min
- Unit
- min
In testing for 2001 to 2026.
Regeneration duration SKODA_REGEN_DUR_V2
- Request
22 39 F9 - Service 22
DID 39F9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 60)- Range
- 0 to 1092.25 min
- Unit
- min
In testing for 2001 to 2026.
Regulation factor total SKODA_PQ35_REG_FACTOR
- Request
22 10 E4 - Service 22
DID 10E4 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10000)- Range
- 0 to 3.276 %
- Unit
- %
In testing for 2001 to 2026.
Relative load value SKODA_REL_LOAD
- Request
22 12 16 - Service 22
DID 1216 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0234403081)- Range
- 0 to 1536.1605
- Unit
- Number
In testing for 2001 to 2026.
Relay for reserve coolant pump status SKODA_RELAY_RESERVE_CLT
- Request
22 39 99 - Service 22
DID 3999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Requested torque, amount for auxiliary units SKODA_REQ_TQ_AMOUNT
- Request
22 10 BE - Service 22
DID 10BE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Reserve torque SKODA_RESERVE_TQ
- Request
22 10 6A - Service 22
DID 106A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Result of crankcase ventilation test, fail SKODA_RESULT_CRANKCASE
- Request
22 15 CC - Service 22
DID 15CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Result of crankcase ventilation test, successful SKODA_RESULT_CRANKCASE_VENTILATION_TEST
- Request
22 15 CB - Service 22
DID 15CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Right central air outlet temperature SKODA_RIGHT_CENTRAL_AIR_T
- Request
22 42 C6 - Service 22
DID 42C6 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Right footwell air outlet temperature SKODA_RIGHT_FOOTWELL_AIR_T
- Request
22 42 BD - Service 22
DID 42BD - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Right rear footwell air outlet temperature SKODA_RIGHT_REAR_FOOTWELL_T
- Request
22 42 C2 - Service 22
DID 42C2 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Right rear upper air outlet temperature SKODA_RIGHT_REAR_HI_AIR_T
- Request
22 42 C0 - Service 22
DID 42C0 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Right side air outlet temperature SKODA_RIGHT_SIDE_AIR_T
- Request
22 42 C4 - Service 22
DID 42C4 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2001 to 2026.
Rotor position sensor cosine amplitude SKODA_ROTOR_COS_AMP_V
- Request
22 4E 91 - Service 22
DID 4E91 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2001 to 2026.
Rotor position sensor cosine offset SKODA_ROTOR_COS_OFS_V
- Request
22 4E 93 - Service 22
DID 4E93 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2001 to 2026.
Rotor position sensor cosine track SKODA_ROTOR_COS
- Request
22 46 61 - Service 22
DID 4661 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Rotor position sensor sine amplitude SKODA_ROTOR_SIN_AMP_V
- Request
22 4E 90 - Service 22
DID 4E90 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2001 to 2026.
Rotor position sensor sine track SKODA_ROTOR_SIN
- Request
22 46 60 - Service 22
DID 4660 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Rotor position sensor sine voltage SKODA_ROTOR_SIN_V
- Request
22 4E 92 - Service 22
DID 4E92 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2001 to 2026.
Rotor temperature model SKODA_ROTOR_T_MODEL
- Request
22 2C CC - Service 22
DID 2CCC - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 1000 °C
- Unit
- °C
In testing for 2001 to 2026.
Route data, active SKODA_ROUTE_DATA_ACTIVE
- Request
22 28 2C - Service 22
DID 282C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Second pilot injection, duration SKODA_PRE_INJ_2_DURATION
- Request
22 14 D1 - Service 22
DID 14D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2001 to 2026.
Second pilot injection, start SKODA_PRE_INJ_2_START
- Request
22 14 C8 - Service 22
DID 14C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 °
- Unit
- °
In testing for 2001 to 2026.
Secondary air injection sensor 1 SKODA_SECONDARY_AIR_INJ_1
- Request
22 3F 68 - Service 22
DID 3F68 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2001 to 2026.
SEG_AD_MMV_ER_H, 0 SKODA_SEG_AD_MMV_ER_H_0
- Request
22 11 38 - Service 22
DID 1138 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER_H, 2 SKODA_SEG_AD_MMV_ER_H_2
- Request
22 11 3A - Service 22
DID 113A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER_H, 3 SKODA_SEG_AD_MMV_ER_H_3
- Request
22 11 3B - Service 22
DID 113B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER_L, 0 SKODA_SEG_AD_MMV_ER_L_0
- Request
22 11 3E - Service 22
DID 113E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER_L, 2 SKODA_SEG_AD_MMV_ER_L_2
- Request
22 11 40 - Service 22
DID 1140 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER_L, 3 SKODA_SEG_AD_MMV_ER_L_3
- Request
22 11 41 - Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER_MID, 0 SKODA_SEG_AD_MMV_ER_MID_0
- Request
22 11 32 - Service 22
DID 1132 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER_MID, 1 SKODA_SEG_AD_MMV_ER_MID_1
- Request
22 11 33 - Service 22
DID 1133 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER_MID, 2 SKODA_SEG_AD_MMV_ER_MID_2
- Request
22 11 34 - Service 22
DID 1134 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER, 1 SKODA_SEG_AD_MMV_ER_1
- Request
22 11 2D - Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER, 2 SKODA_SEG_AD_MMV_ER_2
- Request
22 11 2E - Service 22
DID 112E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
SEG_AD_MMV_ER, 3 SKODA_SEG_AD_MMV_ER_3
- Request
22 11 2F - Service 22
DID 112F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 78123 ÷ 327670000)- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2001 to 2026.
Sensor for particle filter differential pressure, raw value SKODA_SENS_PARTICLE_FLT_P
- Request
22 39 E9 - Service 22
DID 39E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Service interval extension, max oil level SKODA_WIV_MAX_OIL_LEVEL
- Request
22 12 30 - Service 22
DID 1230 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 mm
- Unit
- mm
In testing for 2001 to 2026.
Service interval extension, min oil level SKODA_WIV_MIN_OIL_LEVEL
- Request
22 12 31 - Service 22
DID 1231 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 mm
- Unit
- mm
In testing for 2001 to 2026.
Service limit SKODA_SERVICE_LIM
- Request
22 12 CB - Service 22
DID 12CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655
- Unit
- Raw value
In testing for 2001 to 2026.
Service limit SKODA_SERVICE_LIM_7E0
- Request
22 58 51 - Service 22
DID 5851 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Service limit SKODA_SERVICE_LIM_V2
- Request
22 20 DA - Service 22
DID 20DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Service limit value SKODA_PQ35_SRV_LIM
- Request
22 12 CB - Service 22
DID 12CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2001 to 2026.
Service regeneration current duration SKODA_SERVICE_REGEN
- Request
22 11 C3 - Service 22
DID 11C3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100)- Range
- 0 to 42949672 s
- Unit
- s
In testing for 2001 to 2026.
Shunt temperature SKODA_BMS_SHUNT_T
- Request
22 18 0F - Service 22
DID 180F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
SIM card, SIM card in main unit SKODA_SIM_CARD_SIM_CARD
- Request
22 18 14 - Service 22
DID 1814 - Module
773 → 7DD - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Simulated DPF temperature SKODA_SIMULATED_DPF_T
- Request
22 3D 7F - Service 22
DID 3D7F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2001 to 2026.
Smoke limit SKODA_PQ35_LIM_SMOKE
- Request
22 13 01 - Service 22
DID 1301 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Soot mass calculated SKODA_SOOT_MASS_CALC
- Request
22 20 8B - Service 22
DID 208B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Soot mass measured SKODA_SOOT_MASS_MEAS_V2
- Request
22 20 8C - Service 22
DID 208C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127
- Unit
- Raw value
In testing for 2001 to 2026.
Spark efficiency deviation at idle SKODA_SPARK_EFFICIENCY_DEV
- Request
22 11 2C - Service 22
DID 112C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 781 ÷ 1000)- Range
- 0 to 199 %
- Unit
- %
In testing for 2001 to 2026.
Spark efficiency deviation at idle, maximum SKODA_SPARK_EFFICIENCY_DEV_MAX
- Request
22 15 5B - Service 22
DID 155B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Spark efficiency deviation at part load SKODA_SPARK_EFF_DEV
- Request
22 11 2D - Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 78.1 ÷ 100)- Range
- 0 to 199.14 %
- Unit
- %
In testing for 2001 to 2026.
Spark efficiency deviation at part load SKODA_SPARK_EFF_DEV_PART
- Request
22 11 2D - Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 78.1 ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Spark efficiency deviation at part load SKODA_SPARK_EFFICIENCY_DEV_V2
- Request
22 11 2D - Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 781 ÷ 1000)- Range
- 0 to 199 %
- Unit
- %
In testing for 2001 to 2026.
Spark efficiency deviation at part load, maximum SKODA_SPARK_EFFICIENCY_DEV_PART_MAX
- Request
22 15 5C - Service 22
DID 155C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Static torque limitation SKODA_STATIC_TQ_LIM
- Request
22 10 66 - Service 22
DID 1066 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Status CC ECU, temperature. st.disc SKODA_STAT_CC_ECU_T_ST
- Request
22 11 0A - Service 22
DID 110A - Module
70F → 779 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2001 to 2026.
Stop signal switch SKODA_MQB_TCM_STOP_SIGNAL_SWITCH
- Request
22 38 00 - Service 22
DID 3800 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Sum of misfires counter SKODA_SUM_MIS_CNT
- Request
22 10 F2 - Service 22
DID 10F2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Tank fill level diagnostic reference value SKODA_TANK_FILL_LEVEL
- Request
22 51 D8 - Service 22
DID 51D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2001 to 2026.
TCO_1_ST SKODA_TCO_1_ST
- Request
22 11 D0 - Service 22
DID 11D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
TCO_1_SYS SKODA_TCO_1_SYS
- Request
22 11 CD - Service 22
DID 11CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature after evaporator SKODA_CLIMATE_T_AFTER_EVAP
- Request
22 26 12 - Service 22
DID 2612 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 3)- Range
- -42.624 to 42.291 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature after evaporator SKODA_PQ35_EVAP_OUT_T
- Request
22 26 12 - Service 22
DID 2612 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.333)- Range
- -42.624 to 42.291 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature at air conditioner heat exchanger output SKODA_T_AC_HEAT_EXCHANGER
- Request
22 11 77 - Service 22
DID 1177 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature sensor 14 SKODA_T_SENS_14
- Request
22 1E BB - Service 22
DID 1EBB - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature sensor for engine temperature management SKODA_T_SENS_ENG_T
- Request
22 39 2A - Service 22
DID 392A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature sensor for engine temperature management, target value SKODA_T_SENS_ENG_T_TGT
- Request
22 40 E2 - Service 22
DID 40E2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature status, controller SKODA_STAT_NIA_T
- Request
22 11 01 - Service 22
DID 1101 - Module
70F → 779 - Every
5 s - Testing
Bits 136 to 151 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature status, RPS SKODA_STAT_NIA_T_RPS
- Request
22 11 01 - Service 22
DID 1101 - Module
70F → 779 - Every
5 s - Testing
Bits 152 to 167 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature status, SBC SKODA_STAT_NIA_T_SBC
- Request
22 11 01 - Service 22
DID 1101 - Module
70F → 779 - Every
5 s - Testing
Bits 168 to 183 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature, electric drive inflow coolant SKODA_ELEC_DRIVE_INFLOW_COOLANT_T
- Request
22 4F AE - Service 22
DID 4FAE - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 1000 °C
- Unit
- °C
In testing for 2001 to 2026.
Temperature, motor SKODA_MOTOR_T_V2
- Request
22 46 72 - Service 22
DID 4672 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 1000 °C
- Unit
- °C
In testing for 2001 to 2026.
Test of catalytic converter status, canceled SKODA_TEST_CATALYTIC_CONV_STAT
- Request
22 29 27 - Service 22
DID 2927 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Test of catalytic converter, measured value SKODA_TEST_CATALYTIC_CONV
- Request
22 29 26 - Service 22
DID 2926 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535
- Unit
- Number
In testing for 2001 to 2026.
Thermal load of AWD drive pump SKODA_THERMAL_LOAD_AWD
- Request
22 2B 09 - Service 22
DID 2B09 - Module
71D → 787 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2001 to 2026.
Thermostat, actual SKODA_THERMOSTAT_ACT
- Request
22 44 18 - Service 22
DID 4418 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12207 ÷ 1000000)- Range
- 0 to 799 %
- Unit
- %
In testing for 2001 to 2026.
Thermostat, commanded SKODA_THERMOSTAT_CMD
- Request
22 44 17 - Service 22
DID 4417 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12207 ÷ 1000000)- Range
- 0 to 799 %
- Unit
- %
In testing for 2001 to 2026.
Throttle regulator nominal value SKODA_THROTTLE_REGULATOR
- Request
22 16 C5 - Service 22
DID 16C5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Throttle valve adapter position SKODA_PQ35_THROT_VALVE_ADAPT
- Request
22 12 FC - Service 22
DID 12FC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Throttle valve adapter, actual value SKODA_THROTTLE_VLV_ADAPTER_ACT
- Request
22 12 FC - Service 22
DID 12FC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2001 to 2026.
TI_1_MPI, 0 SKODA_TI_1_MPI_0
- Request
22 13 AC - Service 22
DID 13AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_1_MPI, 1 SKODA_TI_1_MPI_1
- Request
22 13 AD - Service 22
DID 13AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_1_MPI, 2 SKODA_TI_1_MPI_2
- Request
22 13 AE - Service 22
DID 13AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_1_MPI, 3 SKODA_TI_1_MPI_3
- Request
22 13 AF - Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_1, 1 SKODA_TI_MES4_PLS_1_1
- Request
22 13 A1 - Service 22
DID 13A1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_1, 2 SKODA_TI_MES4_PLS_1_2
- Request
22 13 A2 - Service 22
DID 13A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_1, 3 SKODA_TI_MES4_PLS_1_3
- Request
22 13 A3 - Service 22
DID 13A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_2, 0 SKODA_TI_MES4_PLS_2_0
- Request
22 13 A4 - Service 22
DID 13A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_2, 1 SKODA_TI_MES4_PLS_2_1
- Request
22 13 A5 - Service 22
DID 13A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_2, 2 SKODA_TI_MES4_PLS_2_2
- Request
22 13 A6 - Service 22
DID 13A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_2, 3 SKODA_TI_MES4_PLS_2_3
- Request
22 13 A7 - Service 22
DID 13A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_3, 0 SKODA_TI_MES4_PLS_3_0
- Request
22 13 A8 - Service 22
DID 13A8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_3, 1 SKODA_TI_MES4_PLS_3_1
- Request
22 13 A9 - Service 22
DID 13A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_3, 2 SKODA_TI_MES4_PLS_3_2
- Request
22 13 AA - Service 22
DID 13AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
TI_MES4_PLS_3, 3 SKODA_TI_MES4_PLS_3_3
- Request
22 13 AB - Service 22
DID 13AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2001 to 2026.
Time in run-on after shutdown SKODA_TIME_AFTERRUN
- Request
22 10 3A - Service 22
DID 103A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2001 to 2026.
Time since last regen. SKODA_TIME_SINCE_REGEN
- Request
22 11 5E - Service 22
DID 115E - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 60)- Range
- 0 to 71582788 min
- Unit
- min
In testing for 2001 to 2026.
Time since last regeneration SKODA_TIME_SINCE_REGEN_V2
- Request
22 20 89 - Service 22
DID 2089 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 2001 to 2026.
Time since reset SKODA_TIME_SINCE_RESET
- Request
22 10 3B - Service 22
DID 103B - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 30)- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 2001 to 2026.
Time with transmission fluid above 135 degrees SKODA_ANALYSIS_40_ATF_T_135_C
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 159 of the reply, 32 bits.
- Formula
(val ÷ 5)- Range
- 0 to 858993459 s
- Unit
- s
In testing for 2001 to 2026.
Time with transmission fluid at 65 to 80 degrees SKODA_ANALYSIS_40_ATF_T_65_C_80_C
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 5)- Range
- 0 to 858993459 s
- Unit
- s
In testing for 2001 to 2026.
Time with transmission fluid at 80 to 110 degrees SKODA_ANALYSIS_40_ATF_T_80_C_110_C
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 64 to 95 of the reply, 32 bits.
- Formula
(val ÷ 5)- Range
- 0 to 858993459 s
- Unit
- s
In testing for 2001 to 2026.
Time with transmission fluid at 110 to 135 degrees SKODA_ANALYSIS_40_ATF_T_110_C_135_C
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 127 of the reply, 32 bits.
- Formula
(val ÷ 5)- Range
- 0 to 858993459 s
- Unit
- s
In testing for 2001 to 2026.
Time with transmission fluid below 65 degrees SKODA_ANALYSIS_40_ATF_T_65_C
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 5)- Range
- 0 to 858993459 s
- Unit
- s
In testing for 2001 to 2026.
Timing angle retardation cylinder 1 SKODA_TIMING_ANGLE_RETARDATION_CYL_1
- Request
22 20 0A - Service 22
DID 200A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.375 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2001 to 2026.
Timing angle retardation cylinder 2 SKODA_TIMING_ANGLE_RETARDATION_CYL_2
- Request
22 20 0B - Service 22
DID 200B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.375 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2001 to 2026.
Timing angle retardation cylinder 3 SKODA_TIMING_ANGLE_RETARDATION_CYL_3
- Request
22 20 0C - Service 22
DID 200C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.375 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2001 to 2026.
Timing angle retardation cylinder 4 SKODA_TIMING_ANGLE_RETARDATION_CYL_4
- Request
22 20 0D - Service 22
DID 200D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.375 − 48)- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2001 to 2026.
Timing deviation after chain replacement, exhaust bank 1 SKODA_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1
- Request
22 41 7D - Service 22
DID 417D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2001 to 2026.
Timing deviation after chain replacement, intake bank 1 SKODA_TIM_DEV_AFTER_CHAIN_1
- Request
22 41 7B - Service 22
DID 417B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2001 to 2026.
Timing deviation after other repairs, intake bank 1 SKODA_TIM_DEV_AFTER_OTHER_1
- Request
22 41 7F - Service 22
DID 417F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2001 to 2026.
Timing deviation after other repairs, intake bank 1 SKODA_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1
- Request
22 41 81 - Service 22
DID 4181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2001 to 2026.
Timing deviation current value exhaust bank 1 SKODA_TIM_DEV_CURRENT_EXH_1
- Request
22 41 85 - Service 22
DID 4185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2001 to 2026.
Timing deviation current value intake bank 1 SKODA_TIM_DEV_CURRENT_INT_1
- Request
22 41 83 - Service 22
DID 4183 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2001 to 2026.
Torque converter clutch status SKODA_TC_STS
- Request
22 70 78 - Service 22
DID 7078 - Module
FC00 → FE0077 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 55)- Range
- -55 to 200 °C
- Unit
- °C
In testing for 2001 to 2026.
Torque converter slip SKODA_TORQUE_CONVERTER_SLIP_FC00
- Request
22 21 31 - Service 22
DID 2131 - Module
FC00 → FE0077 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2001 to 2026.
Torque converter: torque loss SKODA_TORQUE_CONVERTER_TORQUE_LOSS
- Request
22 70 53 - Service 22
DID 7053 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque converter: torque loss SKODA_TORQUE_CONVERTER_TORQUE_LOSS_V2
- Request
22 70 53 - Service 22
DID 7053 - Module
FC00 → FE0077 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque distribution SKODA_TQ_DISTRIBUTION
- Request
22 2B 0A - Service 22
DID 2B0A - Module
71D → 787 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque factor SKODA_TQ_FACTOR
- Request
22 21 19 - Service 22
DID 2119 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Torque increase request from ESP SKODA_TQ_INCREASE_REQ_ESP
- Request
22 13 40 - Service 22
DID 1340 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque limit SKODA_PQ35_LIM_TRQ
- Request
22 10 6B - Service 22
DID 106B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque limitation SKODA_TORQUE_LIMITATION
- Request
22 20 3F - Service 22
DID 203F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque limitation SKODA_TORQUE_LIMITATION_V2
- Request
22 20 3F - Service 22
DID 203F - Module
FC00 → FE0077 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque limitation SKODA_TQ_LIM
- Request
22 10 7D - Service 22
DID 107D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque limitation SKODA_TQ_LIM_7E0
- Request
22 20 3F - Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque limitation, clutch protection SKODA_TQ_LIM_CLU
- Request
22 20 A0 - Service 22
DID 20A0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque loss adaptation SKODA_TQ_LOSS_ADPT
- Request
22 21 22 - Service 22
DID 2122 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque loss adaptation at idle SKODA_TQ_LOSS_ADPT_IDLE
- Request
22 12 25 - Service 22
DID 1225 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque loss adaptation, A/C compressor SKODA_TQ_LOSS_ADPT_AC_COMP_7E0
- Request
22 12 23 - Service 22
DID 1223 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque loss adaptation, A/C compressor SKODA_TQ_LOSS_ADPT_AC_COMP_V2
- Request
22 12 23 - Service 22
DID 1223 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque reduction due to exhaust temperature SKODA_PQ35_TRQ_RED_EXH_T
- Request
22 10 E3 - Service 22
DID 10E3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10000)- Range
- -3.2768 to 3.276
- Unit
- Number
In testing for 2001 to 2026.
Torque reduction request from ESP SKODA_TQ_REDUCTION_REQ_ESP
- Request
22 13 3F - Service 22
DID 133F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque request, sum of auxiliary aggregate SKODA_TQ_REQ_SUM_AUXILIARY
- Request
22 20 9B - Service 22
DID 209B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2001 to 2026.
Torque transmitting function SKODA_TQ_TRANSMITTING_V2
- Request
22 21 05 - Service 22
DID 2105 - Module
71D → 787 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 49 ÷ 6250)- Range
- 0 to 513
- Unit
- Number
In testing for 2001 to 2026.
Torque transmitting function, ratio SKODA_TQ_TRANSMITTING
- Request
22 21 05 - Service 22
DID 2105 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Number
In testing for 2001 to 2026.
Total mass of gasoline and ethyl alcohol in oil SKODA_TOT_MASS_GASOLINE
- Request
22 17 13 - Service 22
DID 1713 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.021333)- Range
- 0 to 1398.0581
- Unit
- Raw value
In testing for 2001 to 2026.
Transmission fluid temperature SKODA_ATF_T_FC00
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 21 04 - Service 22
DID 2104 - Module
FC00 → FE0077 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2026.
Transmission fluid temperature, calculated SKODA_ATF_T_CALCULATED
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 70 4E - Service 22
DID 704E - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
Transmission fluid temperature, calculated SKODA_ATF_T_CALCULATED_V2
- Request
22 70 4E - Service 22
DID 704E - Module
FC00 → FE0077 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
Transmission fluid temperature, dual-clutch SKODA_ATF_T_DUAL_CLU
- Request
22 21 04 - Service 22
DID 2104 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2001 to 2026.
Transmission fluid temperature, maximum reached SKODA_ATF_T_MAX_REACHED
- Request
22 70 4F - Service 22
DID 704F - Module
FC00 → FE0077 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2001 to 2026.
Transmission fluid temperature, modeled max reached SKODA_ATF_T_MODELED_MAX_REACHED_V2
- Request
22 70 51 - Service 22
DID 7051 - Module
FC00 → FE0077 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 55)- Range
- -55 to 200 °C
- Unit
- °C
In testing for 2001 to 2026.
Transmission fluid temperature, modeled maximum reached SKODA_ATF_T_MODELED_MAX_REACHED
- Request
22 70 51 - Service 22
DID 7051 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 55)- Range
- -55 to 200 °C
- Unit
- °C
In testing for 2001 to 2026.
Turbine actuator 1 bank 1 activation SKODA_PQ35_TURB_ACT_1_B1
- Request
22 11 7E - Service 22
DID 117E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Turbine actuator 1 bank 1: activation SKODA_ACT
- Request
22 11 2C - Service 22
DID 112C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Upper adapted coupling point K1 from macro slip path adaptation SKODA_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPT
- Request
22 11 0B - Service 22
DID 110B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5)- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2001 to 2026.
Upper adapted coupling point K2 from macro slip path adaptation SKODA_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPT
- Request
22 11 0C - Service 22
DID 110C - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5)- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2001 to 2026.
Valve lift system, result of last switch, intake SKODA_VLV_LIFT_SYSTEM
- Request
22 16 BE - Service 22
DID 16BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Valve lift system, valve lift, exhaust SKODA_VLV_LIFT_SYSTEM_VLV_LIFT
- Request
22 16 BB - Service 22
DID 16BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Valve lift system, valve lift, intake SKODA_VLV_LIFT_SYSTEM_VLV
- Request
22 16 BA - Service 22
DID 16BA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Valve timing, the difference between the, actual and the set angle SKODA_VLV_TIM_DIFF_ACT_SET
- Request
22 10 EC - Service 22
DID 10EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °
- Unit
- °
In testing for 2001 to 2026.
Variable valve timing, intake, bank 1, regulation SKODA_VARIABLE_VLV_TIM_INT_1
- Request
22 12 7B - Service 22
DID 127B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0030517549)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Variable valve timing, intake, bank 1, switch on SKODA_VARIABLE_VLV_TIM_INT_1_ON
- Request
22 12 7D - Service 22
DID 127D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0030517549)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Washer nozzle heater active SKODA_HTR_NOZZLE
- Request
22 19 45 - Service 22
DID 1945 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Wear index SKODA_PQ35_WEAR_IDX
- Request
22 10 E2 - Service 22
DID 10E2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 m
- Unit
- m
In testing for 2001 to 2026.
Wear index %, 0=new engine SKODA_WEAR_INDEX_0_NEW_ENG
- Request
22 20 C2 - Service 22
DID 20C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Engine › DPF
Diesel particulate filter ash load limit SKODA_MQB_DPF_ASH_LOAD_LIMIT
- Request
22 1A BF - Service 22
DID 1ABF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 78.125 ÷ 10000)- Range
- 0 to 511.992
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter diff pressure: raw value 1 SKODA_MQB_DPF_DIFF_P_RAW_VALUE_1
- Request
22 26 9A - Service 22
DID 269A - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter diff pressure: raw value 2 SKODA_MQB_DPF_DIFF_P_RAW_VALUE_2
- Request
22 26 9B - Service 22
DID 269B - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter field regeneration lock status SKODA_DPF_FIELD_REGEN_LOCK
- Request
22 11 C1 - Service 22
DID 11C1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter field regeneration request SKODA_MQB_DPF_FIELD_REGEN_REQUEST
- Request
22 1A C2 - Service 22
DID 1AC2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter fuel consumption since last regeneration SKODA_MQB_DPF_FUEL_CONSUMPTION_SINCE_LAST_REGEN
- Request
22 1A C1 - Service 22
DID 1AC1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2001 to 2026.
Diesel particulate filter fuel consumption since last regeneration SKODA_PQ35_DPF_FUEL_CON_REGEN
- Request
22 11 5A - Service 22
DID 115A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 L
- Unit
- L
In testing for 2001 to 2026.
Diesel particulate filter inlet lambda value SKODA_MQB_DPF_INLET_LAMBDA_VALUE
- Request
22 1A D5 - Service 22
DID 1AD5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 10 ÷ 10000)- Range
- -32.768 to 32.767
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter oil ash volume SKODA_PQ35_DPF_OIL_ASH_VOL
- Request
22 11 53 - Service 22
DID 1153 - Module
7E0 → 7E8 - Every
10.25 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 L
- Unit
- L
In testing for 2001 to 2026.
Diesel particulate filter regeneration level current SKODA_MQB_DPF_REGEN_LEVEL_I
- Request
22 1A D3 - Service 22
DID 1AD3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter regeneration release requirement SKODA_MQB_DPF_REGEN_RELEASE_REQUIREMENT
- Request
22 1A D2 - Service 22
DID 1AD2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter regeneration status SKODA_MQB_DPF_REGEN_STATUS
- Request
22 1A D4 - Service 22
DID 1AD4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter regeneration time counter SKODA_MQB_DPF_REGEN_TIME_COUNTER
- Request
22 1A C0 - Service 22
DID 1AC0 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 6400 ÷ 10000)- Range
- 0 to 41942.4 s
- Unit
- s
In testing for 2001 to 2026.
Diesel particulate filter service regeneration current duration SKODA_MQB_DPF_SERVICE_REGEN_I_DURATION
- Request
22 1A C4 - Service 22
DID 1AC4 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 6400 ÷ 10000)- Range
- 0 to 41942.4 s
- Unit
- s
In testing for 2001 to 2026.
Diesel particulate filter soot mass measured SKODA_MQB_DPF_SOOT_MASS_MEASURED
- Request
22 1A BE - Service 22
DID 1ABE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100 ÷ 10000)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter statistics average drive cycle time during charge cycle SKODA_MQB_DPF_STATISTICS_AVERAGE_DRIVE_CYCLE_TIME_DURING_CHARGE_CYCLE
- Request
22 1A CC - Service 22
DID 1ACC - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1600 ÷ 100)- Range
- 0 to 4080 s
- Unit
- s
In testing for 2001 to 2026.
Diesel particulate filter statistics error status SKODA_MQB_DPF_STATISTICS_ERROR_STATUS
- Request
22 1A CA - Service 22
DID 1ACA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter statistics exhaust temperature regulation average value SKODA_MQB_DPF_STATISTICS_EXHAUST_T_REGULATION_AVERAGE_VALUE
- Request
22 1A C7 - Service 22
DID 1AC7 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 1.98 ÷ 127)- Range
- -1.99 to 1.98
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter statistics number of interrupted regenerations SKODA_MQB_DPF_STATISTICS_NUMBER_INTERRUPTED_REGENS
- Request
22 1A C9 - Service 22
DID 1AC9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter statistics regeneration blocked status SKODA_MQB_DPF_STATISTICS_REGEN_BLOCKED_STATUS
- Request
22 1A C8 - Service 22
DID 1AC8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter statistics regeneration request SKODA_MQB_DPF_STATISTICS_REGEN_REQUEST
- Request
22 1A C5 - Service 22
DID 1AC5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter statistics regeneration time SKODA_MQB_DPF_STATISTICS_REGEN_TIME
- Request
22 1A CD - Service 22
DID 1ACD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 6400 ÷ 100)- Range
- 0 to 16320 s
- Unit
- s
In testing for 2001 to 2026.
Diesel particulate filter statistics regeneration time slice not possible in charge cycle SKODA_MQB_DPF_STATISTICS_REGEN_TIME_SLICE_NOT_POSS_IN_CHARGE_CYCLE
- Request
22 1A CE - Service 22
DID 1ACE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.498 ÷ 255)- Range
- 0 to 0.498
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter statistics route in charge cycle SKODA_MQB_DPF_STATISTICS_ROUTE_IN_CHARGE_CYCLE
- Request
22 1A CB - Service 22
DID 1ACB - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 800 ÷ 100)- Range
- 0 to 2040 km
- Unit
- km
In testing for 2001 to 2026.
Diesel particulate filter time since last regeneration SKODA_MQB_DPF_TIME_SINCE_LAST_REGEN
- Request
22 1A C3 - Service 22
DID 1AC3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 127.998 ÷ 65535)- Range
- 0 to 127.998 h
- Unit
- h
In testing for 2001 to 2026.
Diesel particulate filter unburned fuel calculated SKODA_MQB_DPF_UNBURNED_FUEL_CALCULATED
- Request
22 18 BB - Service 22
DID 18BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -32.768 to 32.767
- Unit
- Number
In testing for 2001 to 2026.
Diesel particulate filter, charge limit for service regeneration while driving SKODA_MQB_DPF_CHARGE_LIMIT_SERVICE_REGEN_WHILE_DRIVING
- Request
22 1A BB - Service 22
DID 1ABB - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter, charge limit over-charge SKODA_MQB_DPF_CHARGE_LIMIT_OVER_CHARGE
- Request
22 1A BC - Service 22
DID 1ABC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100 ÷ 10000)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Diesel particulate filter, distance since last regeneration SKODA_MQB_DPF_DISTANCE_SINCE_LAST_REGEN
- Request
22 1A BA - Service 22
DID 1ABA - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 2001 to 2026.
Distance since last regeneration SKODA_PQ35_DIST_LAST_REGEN
- Request
22 11 56 - Service 22
DID 1156 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2001 to 2026.
Particulate filter soot mass calculated SKODA_DPF_SOOT_MASS_CALCULATED
- Request
22 26 09 - Service 22
DID 2609 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100 ÷ 10000)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Regeneration duration SKODA_PQ35_REGEN_DUR
- Request
22 13 47 - Service 22
DID 1347 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 min
- Unit
- min
In testing for 2001 to 2026.
Service regeneration status SKODA_SRV_REGEN_STAT
- Request
22 11 5C - Service 22
DID 115C - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2026.
Soot index SKODA_PQ35_SOOT_IDX
- Request
22 13 54 - Service 22
DID 1354 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 m
- Unit
- m
In testing for 2001 to 2026.
Soot mass calculated SKODA_PQ35_SOOT_MASS_CALC
- Request
22 11 4F - Service 22
DID 114F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2001 to 2026.
Soot mass measured SKODA_SOOT_MASS_MEAS
- Request
22 11 4E - Service 22
DID 114E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2001 to 2026.
Unidentified engine value, raw count SKODA_ENG_114F_RAW
- Request
22 11 4F - Service 22
DID 114F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2026.
Engine › EGR
Exhaust gas recirculation 2: filter press loss, modeled SKODA_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_MODELED
- Request
22 2A E1 - Service 22
DID 2AE1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 500)- Range
- -3776.8 to 2776.7
- Unit
- Raw value
In testing for 2001 to 2026.
Exhaust gas recirculation 2: filter press loss, simulated SKODA_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_SIMULATED
- Request
22 2A E2 - Service 22
DID 2AE2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 500)- Range
- -3776.8 to 2776.7
- Unit
- Raw value
In testing for 2001 to 2026.
High press EGR closing v1 SKODA_PQ35_HIGH_P_EGR_CLOSING_VAR_1
- Request
22 F4 69 - Service 22
DID F469 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
High press EGR closing v2 SKODA_PQ35_HIGH_P_EGR_CLOSING_VAR_2
- Request
22 F4 2C - Service 22
DID F42C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2026.
Engine › Water pump
Water pump power SKODA_PTC_PUMP_PWR
- Request
22 27 D6 - Service 22
DID 27D6 - Module
742 → 7AC - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 40)- Range
- 0 to 10200
- Unit
- Raw value
In testing for 2001 to 2026.
Water pump RPM SKODA_PTC_PUMP_RPM
- Request
22 27 D6 - Service 22
DID 27D6 - Module
742 → 7AC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 300)- Range
- 0 to 76500 rpm
- Unit
- rpm
In testing for 2001 to 2026.