Trip parameters
The Škoda Kamiq has 94 trip parameters.
● Confirmed◆ In testing○ Supported× Not supported
Analysis, clutch 1 temperature time in range 1 SKODA_ANALYSIS_CLU_1_T_1
- Request
22 10 66 - Service 22
DID 1066 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2019 to 2026.
Analysis, clutch 1 temperature time in range 2 SKODA_ANALYSIS_CLU_1_T_2
- Request
22 10 67 - Service 22
DID 1067 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2019 to 2026.
Analysis, clutch 1 temperature time in range 3 SKODA_ANALYSIS_CLU_1_T_3
- Request
22 10 68 - Service 22
DID 1068 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2019 to 2026.
Analysis, clutch 2 temperature time in range 0 SKODA_ANALYSIS_CLU_2_T_0
- Request
22 10 7A - Service 22
DID 107A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2019 to 2026.
Analysis, clutch 2 temperature time in range 1 SKODA_ANALYSIS_CLU_2_T_1
- Request
22 10 7B - Service 22
DID 107B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2019 to 2026.
Analysis, clutch 2 temperature time in range 2 SKODA_ANALYSIS_CLU_2_T_2
- Request
22 10 7C - Service 22
DID 107C - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2019 to 2026.
Analysis, clutch 2 temperature time in range 3 SKODA_ANALYSIS_CLU_2_T_3
- Request
22 10 7D - Service 22
DID 107D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2019 to 2026.
Average consumption, category 0 SKODA_AVG_CSMP_CAT0
- Request
22 2A B7 - Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2019 to 2026.
Average consumption, category 1 SKODA_AVG_CSMP_CAT1
- Request
22 2A B7 - Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2019 to 2026.
Average consumption, category 2 SKODA_AVG_CSMP_CAT2
- Request
22 2A B7 - Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2019 to 2026.
Average consumption, category 3 SKODA_AVG_CSMP_CAT3
- Request
22 2A B7 - Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2019 to 2026.
Average consumption, category 4 SKODA_AVG_CSMP_CAT4
- Request
22 2A B7 - Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2019 to 2026.
Average consumption, category 5 SKODA_AVG_CSMP_CAT5
- Request
22 2A B7 - Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2019 to 2026.
Average consumption, category 6 SKODA_AVG_CSMP_CAT6
- Request
22 2A B7 - Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2019 to 2026.
Clutch 1 adaptation kiss point part 1 odometer reading SKODA_PQ35_CLUTCH_1_ADAPT_KISS_POINT_PART_1_ODO_READING
- Request
22 10 CA - Service 22
DID 10CA - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 10)- Range
- 0 to 655350 km
- Unit
- km
In testing for 2019 to 2026.
Clutch 1 temperature time in range 0 SKODA_CLU_1_T_TIME_RANGE_0
- Request
22 10 65 - Service 22
DID 1065 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2019 to 2026.
Clutch 2 adaptation kiss point part 1 odometer reading SKODA_PQ35_CLUTCH_2_ADAPT_KISS_POINT_PART_1_ODO_READING
- Request
22 10 EB - Service 22
DID 10EB - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 10)- Range
- 0 to 655350 km
- Unit
- km
In testing for 2019 to 2026.
Diesel particulate filter distance since last regeneration SKODA_DPF_DIST_SINCE_REGEN
- Request
22 20 8D - Service 22
DID 208D - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2019 to 2026.
Diesel particulate filter distance since last regeneration, bank 1 SKODA_DPF_DIST_SINCE_REGEN_1
- Request
22 14 B8 - Service 22
DID 14B8 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2019 to 2026.
Diesel particulate filter distance since last regeneration, bank 2 SKODA_DPF_DIST_SINCE_REGEN_2
- Request
22 14 60 - Service 22
DID 1460 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2019 to 2026.
Distance since last regeneration SKODA_DIST_SINCE_REGEN
- Request
22 20 8D - Service 22
DID 208D - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 2019 to 2026.
Distance to detected pedestrian SKODA_DIST_DETECTED
- Request
22 F4 1B - Service 22
DID F41B - Module
74F → 7B9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 m
- Unit
- m
In testing for 2019 to 2026.
Distance to empty SKODA_PQ35_DIST_EMPTY
Pelican can show this parameter as the fuel range.
- Request
22 22 94 - Service 22
DID 2294 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2019 to 2026.
Drive cycles counter SKODA_MQB_TCM_DRIVE_CYCLES_COUNTER
- Request
22 38 8B - Service 22
DID 388B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Driving time ecological SKODA_MQB_TCM_DRIVING_TIME_ECOLOGICAL
- Request
22 38 88 - Service 22
DID 3888 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Driving time manual SKODA_MQB_TCM_DRIVING_TIME_MANUAL
- Request
22 38 8A - Service 22
DID 388A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Driving time sporty SKODA_MQB_TCM_DRIVING_TIME_SPORTY
- Request
22 38 89 - Service 22
DID 3889 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Engine control unit distance driven SKODA_ECU_DIST_DRIVEN
- Request
22 11 60 - Service 22
DID 1160 - Module
FC00 → FE0076 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2019 to 2026.
Ignition cycles SKODA_MQB_TCM_IGNITION_CYCLES
- Request
22 38 8C - Service 22
DID 388C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Mixture variation in adapted part load range 1 SKODA_MIXTURE_VARIATION_1
- Request
22 39 BC - Service 22
DID 39BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Odometer SKODA_ENG_ODO
Pelican can show this parameter as the odometer.
- Request
22 29 5A - Service 22
DID 295A - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 200000 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_MQB_ODO
Pelican can show this parameter as the odometer.
- Request
22 2A 0A - Service 22
DID 2A0A - Module
710 → 77A - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777175 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_MQB_TCM_ODO
Pelican can show this parameter as the odometer.
- Request
22 38 41 - Service 22
DID 3841 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_ODO
Pelican can show this parameter as the odometer.
- Request
22 22 03 - Service 22
DID 2203 - Module
714 → 77E - Every
10 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_ODO_3
Pelican can show this parameter as the odometer.
- Request
22 2A 0A - Service 22
DID 2A0A - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 255 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_ODO_3_V2
- Request
22 10 3D - Service 22
DID 103D - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_ODO_7E0
Pelican can show this parameter as the odometer.
- Request
22 10 8C - Service 22
DID 108C - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_ODO_7E1
Pelican can show this parameter as the odometer.
- Request
22 10 3D - Service 22
DID 103D - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_ODO_ECM
Pelican can show this parameter as the odometer.
- Request
22 29 5A - Service 22
DID 295A - Module
7E0 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 1048575 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_ODO_V1
- Request
22 38 41 - Service 22
DID 3841 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_ODO_V2
Pelican can show this parameter as the odometer.
- Request
22 2A 0A - Service 22
DID 2A0A - Module
710 → 77A - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
(val − 40)- Range
- -40 to 16777175 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_ODO_V3
Pelican can show this parameter as the odometer.
- Request
22 10 E0 - Service 22
DID 10E0 - Module
7E0 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4000000000 km
- Unit
- km
In testing for 2019 to 2026.
Odometer SKODA_PQ35_ODO
Pelican can show this parameter as the odometer.
- Request
22 22 03 - Service 22
DID 2203 - Module
714 → 77E - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 km
- Unit
- km
In testing for 2019 to 2026.
Odometer (TCM #1) SKODA_ODO_TCM_1
Pelican can show this parameter as the odometer.
- Request
22 38 41 - Service 22
DID 3841 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer (TCM #2 high res) SKODA_ODO_TCM_2_HD
Pelican can show this parameter as the odometer.
- Request
22 38 87 - Service 22
DID 3887 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 km
- Unit
- km
In testing for 2019 to 2026.
Odometer (TCM #2) SKODA_ODO_TCM_2
Pelican can show this parameter as the odometer.
- Request
22 10 1A - Service 22
DID 101A - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019 to 2026.
Odometer #2 SKODA_MQB_TCM_ODO_2
Pelican can show this parameter as the odometer.
- Request
22 38 87 - Service 22
DID 3887 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 km
- Unit
- km
In testing for 2019 to 2026.
Odometer #3 SKODA_PQ35_ODO_3
Pelican can show this parameter as the odometer.
- Request
22 10 1A - Service 22
DID 101A - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019 to 2026.
Odometer at oxidation catalytic converter replacement SKODA_ODO_OXYDATION
- Request
22 4F 3F - Service 22
DID 4F3F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer at SCR catalytic converter replacement SKODA_ODO_SCR_CATALYTIC
- Request
22 4F 41 - Service 22
DID 4F41 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer reading at DPF replace SKODA_ODO_READING_DPF
- Request
22 25 FE - Service 22
DID 25FE - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer reading at fourth-to-last warning SKODA_TPMS_ODO_RDG_AT_FOURTH_TO_LAST_WARN
Pelican can show this parameter as the odometer.
- Request
22 18 21 - Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 232 to 263 of the reply, 32 bits.
- Formula
val- Range
- 0 to 200000 km
- Unit
- km
In testing for 2019 to 2026.
Odometer reading at last adaptation SKODA_TPMS_ODO_RDG_AT_LAST_ADAPT
Pelican can show this parameter as the odometer.
- Request
22 18 21 - Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 8 to 39 of the reply, 32 bits.
- Formula
val- Range
- 0 to 200000 km
- Unit
- km
In testing for 2019 to 2026.
Odometer reading at last warning SKODA_TPMS_ODO_RDG_AT_LAST_WARN
Pelican can show this parameter as the odometer.
- Request
22 18 21 - Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 136 to 167 of the reply, 32 bits.
- Formula
val- Range
- 0 to 200000 km
- Unit
- km
In testing for 2019 to 2026.
Odometer reading at next-to-last warning SKODA_TPMS_ODO_RDG_AT_NEXT_TO_LAST_WARN
Pelican can show this parameter as the odometer.
- Request
22 18 21 - Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 168 to 199 of the reply, 32 bits.
- Formula
val- Range
- 0 to 200000 km
- Unit
- km
In testing for 2019 to 2026.
Odometer reading at third-to-last warning SKODA_TPMS_ODO_RDG_AT_THIRD_TO_LAST_WARN
Pelican can show this parameter as the odometer.
- Request
22 18 21 - Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 200 to 231 of the reply, 32 bits.
- Formula
val- Range
- 0 to 200000 km
- Unit
- km
In testing for 2019 to 2026.
Odometer reading four adaptations ago SKODA_TPMS_ODO_RDG_FOUR_ADAPTATIONS_AGO
Pelican can show this parameter as the odometer.
- Request
22 18 21 - Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 104 to 135 of the reply, 32 bits.
- Formula
val- Range
- 0 to 200000 km
- Unit
- km
In testing for 2019 to 2026.
Odometer reading three adaptations ago SKODA_TPMS_ODO_RDG_THREE_ADAPTATIONS_AGO
Pelican can show this parameter as the odometer.
- Request
22 18 21 - Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 72 to 103 of the reply, 32 bits.
- Formula
val- Range
- 0 to 200000 km
- Unit
- km
In testing for 2019 to 2026.
Odometer reading two adaptations ago SKODA_TPMS_ODO_RDG_TWO_ADAPTATIONS_AGO
Pelican can show this parameter as the odometer.
- Request
22 18 21 - Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 40 to 71 of the reply, 32 bits.
- Formula
val- Range
- 0 to 200000 km
- Unit
- km
In testing for 2019 to 2026.
Odometer reading when changing DPF SKODA_ODO_READING_CHANGING
- Request
22 4F 40 - Service 22
DID 4F40 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer with ECU installed SKODA_ODO_ECU_INSTALLED
- Request
22 29 5B - Service 22
DID 295B - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 m
- Unit
- m
In testing for 2019 to 2026.
Odometer, alternate SKODA_PQ35_ODO_2
Pelican can show this parameter as the odometer.
- Request
22 16 A9 - Service 22
DID 16A9 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, alternative SKODA_ODO_2
Pelican can show this parameter as the odometer.
- Request
22 10 E0 - Service 22
DID 10E0 - Module
7E0 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, alternative SKODA_ODO_2_V2
Pelican can show this parameter as the odometer.
- Request
22 29 5A - Service 22
DID 295A - Module
7E0 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, battery management system SKODA_BMS_ODO
- Request
22 02 BD - Service 22
DID 02BD - Module
FC00 → FE007B - Every
1 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, battery management system, second read SKODA_ODO_BMS2
Pelican can show this parameter as the odometer.
- Request
22 58 67 - Service 22
DID 5867 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, dash SKODA_ODO_DASH
Pelican can show this parameter as the odometer.
- Request
22 22 03 - Service 22
DID 2203 - Module
714 → 77E - Every
10 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 255 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, high resolution SKODA_ODO_HD
Pelican can show this parameter as the odometer.
- Request
22 11 60 - Service 22
DID 1160 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967.295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, mileage SKODA_ODO_MILEAGE
- Request
22 29 5A - Service 22
DID 295A - Module
7E0 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, mileage SKODA_ODO_MILEAGE_V2
- Request
22 16 A9 - Service 22
DID 16A9 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, mileage 1 SKODA_ODO_MILEAGE_1
- Request
22 38 41 - Service 22
DID 3841 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, mileage 2 SKODA_ODO_MILEAGE_2
- Request
22 10 1A - Service 22
DID 101A - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, mileage, HR SKODA_ODO_MILEAGE_HR
- Request
22 22 B8 - Service 22
DID 22B8 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2019 to 2026.
Odometer, mileage, HR SKODA_TRON_ODO_MILEAGE_HR
Pelican can show this parameter as the odometer.
- Request
22 22 B8 - Service 22
DID 22B8 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2019 to 2026.
Operating time, temperature range 1 SKODA_OP_TIME_T_RANGE_1
- Request
22 11 11 - Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
(val × 238607 ÷ 42949672950)- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2019 to 2026.
Operating time, temperature range 2 SKODA_OP_TIME_T_RANGE_2
- Request
22 11 11 - Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
(val × 238607 ÷ 42949672950)- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2019 to 2026.
Operating time, temperature range 3 SKODA_OP_TIME_T_RANGE_3
- Request
22 11 11 - Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
(val × 238607 ÷ 42949672950)- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2019 to 2026.
Operating time, temperature range 4 SKODA_OP_TIME_T_RANGE_4
- Request
22 11 11 - Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
(val × 238607 ÷ 42949672950)- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2019 to 2026.
Operating time, temperature range 5 SKODA_OP_TIME_T_RANGE_5
- Request
22 11 11 - Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
(val × 238607 ÷ 42949672950)- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2019 to 2026.
Operating time, temperature range 6 SKODA_OP_TIME_T_RANGE_6
- Request
22 11 11 - Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
(val × 238607 ÷ 42949672950)- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2019 to 2026.
Range remaining SKODA_RANGE
Pelican can show this parameter as the electric range.
- Request
22 2A B6 - Service 22
DID 2AB6 - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mi
- Unit
- mi
In testing for 2019 to 2026.
Range remaining, displayed SKODA_RANGE_DSP
Pelican can show this parameter as the electric range.
- Request
22 22 E0 - Service 22
DID 22E0 - Module
714 → 77E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2019 to 2026.
Range remaining, unit unconfirmed SKODA_RANGE_V2
- Request
22 2A B6 - Service 22
DID 2AB6 - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mi
- Unit
- mi
In testing for 2019 to 2026.
Remaining distance until reducing agent deficiency SKODA_REMAINING_DIST_UNTIL
- Request
22 29 B1 - Service 22
DID 29B1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 20)- Range
- 0 to 214748364 km
- Unit
- km
In testing for 2019 to 2026.
Torque converter time in temperature range 1 SKODA_TQ_CONV_TIME_T_RANGE_1
- Request
22 17 FC - Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2019 to 2026.
Torque converter time in temperature range 2 SKODA_TQ_CONV_TIME_T_RANGE_2
- Request
22 17 FC - Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 47 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2019 to 2026.
Torque converter time in temperature range 3 SKODA_TQ_CONV_TIME_T_RANGE_3
- Request
22 17 FC - Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2019 to 2026.
Torque converter time in temperature range 4 SKODA_TQ_CONV_TIME_T_RANGE_4
- Request
22 17 FC - Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 72 to 95 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2019 to 2026.
Torque converter time in temperature range 5 SKODA_TQ_CONV_TIME_T_RANGE_5
- Request
22 17 FC - Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 119 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2019 to 2026.
Torque converter time in temperature range 6 SKODA_TQ_CONV_TIME_T_RANGE_6
- Request
22 17 FC - Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 120 to 143 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2019 to 2026.
Torque converter time in temperature range 7 SKODA_TQ_CONV_TIME_T_RANGE_7
- Request
22 17 FC - Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 144 to 167 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2019 to 2026.
Torque converter time in temperature range 8 SKODA_TQ_CONV_TIME_T_RANGE_8
- Request
22 17 FC - Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 168 to 191 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2019 to 2026.
Trip consumption, short SKODA_TRIP_USE_SHORT
- Request
22 05 30 - Service 22
DID 0530 - Module
714 → 77E - Every
500 ms - Testing
Bits 238 to 255 of the reply, 18 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -131 to 131 kWh/100 mi
- Unit
- kWh/100 mi
In testing for 2019 to 2026.
Vehicle distance driven SKODA_VEHICLE_DIST_DRIVEN
- Request
22 10 E0 - Service 22
DID 10E0 - Module
FC00 → FE0076 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.