Škoda Citigo e iV

Battery parameters

The Škoda Citigo e iV has 188 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage CITIGO_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 5A
  • Service 22DID 105A
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20)
Range
0 to 1310700 mV
Unit
mV

In testing for 2019 to 2020.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery voltage CITIGO_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 5A
  • Service 22DID 105A
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20)
Range
0 to 1310700 mV
Unit
mV

In testing for 2019 to 2020.

Charger AC input current CITIGO_CHG_AC_I

  • Request22 1D A8
  • Service 22DID 1DA8
  • Module744
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 A
Unit
A

In testing for 2019 to 2020.

Charger AC input current setpoint CITIGO_CHG_AC_I_SET

  • Request22 15 D3
  • Service 22DID 15D3
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 A
Unit
A

In testing for 2019 to 2020.

Charger AC input voltage CITIGO_CHG_AC_V

  • Request22 1D A9
  • Service 22DID 1DA9
  • Module744
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2019 to 2020.

Charger DC to DC coil temperature CITIGO_CHG_DCDC_COIL_T

  • Request22 15 DA
  • Service 22DID 15DA
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2020.

Charger DC to DC gate driver voltage CITIGO_CHG_DCDC_GATE_V

  • Request22 15 DD
  • Service 22DID 15DD
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2019 to 2020.

Charger DC to DC power line temperature CITIGO_CHG_DCDC_LINE_T

  • Request22 15 EC
  • Service 22DID 15EC
  • Module744
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2020.

Charger output current CITIGO_CHG_HV_I

  • Request22 42 37
  • Service 22DID 4237
  • Module744
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.749 A
Unit
A

In testing for 2019 to 2020.

Charger output current setpoint CITIGO_CHG_HV_I_SET

  • Request22 42 38
  • Service 22DID 4238
  • Module744
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.749 A
Unit
A

In testing for 2019 to 2020.

Charger output voltage CITIGO_CHG_OUT_V

  • Request22 1D A7
  • Service 22DID 1DA7
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2019 to 2020.

Charger power factor coil temperature CITIGO_CHG_PFC_COIL_T

  • Request22 15 D9
  • Service 22DID 15D9
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2020.

Charger power factor gate driver voltage CITIGO_CHG_PFC_GATE_V

  • Request22 15 DC
  • Service 22DID 15DC
  • Module744
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2019 to 2020.

Charger power loss CITIGO_CHG_PWR_LOSS

  • Request22 15 E1
  • Service 22DID 15E1
  • Module744
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20)
Range
0 to 5100 W
Unit
W

In testing for 2019 to 2020.

Charger temperature CITIGO_CHG_T

  • Request22 15 D8
  • Service 22DID 15D8
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2020.

Charging efficiency CITIGO_CHG_EFFICIENCY

  • Request22 15 D6
  • Service 22DID 15D6
  • Module744
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10 + 75)
Range
0 to 100.499 %
Unit
%

In testing for 2019 to 2020.

DC to DC converter circuit board temperature CITIGO_DCDC_PCB_T

  • Request22 46 4E
  • Service 22DID 464E
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

DC to DC converter high-voltage side voltage CITIGO_DCDC_HV_V

  • Request22 15 87
  • Service 22DID 1587
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.968 V
Unit
V

In testing for 2019 to 2020.

DC to DC converter power stage temperature CITIGO_DCDC_PWR_T

  • Request22 46 4F
  • Service 22DID 464F
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

DC to DC converter regulated output voltage CITIGO_PE_DCDC_KL30_V

  • Request22 46 5C
  • Service 22DID 465C
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 512)
Range
-64 to 63.998 V
Unit
V

In testing for 2019 to 2020.

DC to DC converter temperature CITIGO_PE_DCDC_T

  • Request22 3E B5
  • Service 22DID 3EB5
  • Module7E6
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

DC to DC converter traction current CITIGO_DCDC_HV_I

  • Request22 46 50
  • Service 22DID 4650
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 512)
Range
-64 to 63.998 A
Unit
A

In testing for 2019 to 2020.

DC to DC converter traction voltage CITIGO_PE_DCDC_HV_V

  • Request22 46 5E
  • Service 22DID 465E
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.968 V
Unit
V

In testing for 2019 to 2020.

HV battery capacity CITIGO_HVBAT_CAP

Total possible energy in the high voltage battery

  • Request22 2A B2
  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1310770)
Range
0 to 3276 kWh
Unit
kWh

In testing for 2019 to 2020.

HV battery cell 1 voltage CITIGO_HVBAT_CELL_1_V

  • Request22 1E 40
  • Service 22DID 1E40
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 2 voltage CITIGO_HVBAT_CELL_2_V

  • Request22 1E 41
  • Service 22DID 1E41
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 3 voltage CITIGO_HVBAT_CELL_3_V

  • Request22 1E 42
  • Service 22DID 1E42
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 4 voltage CITIGO_HVBAT_CELL_4_V

  • Request22 1E 43
  • Service 22DID 1E43
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 5 voltage CITIGO_HVBAT_CELL_5_V

  • Request22 1E 44
  • Service 22DID 1E44
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 6 voltage CITIGO_HVBAT_CELL_6_V

  • Request22 1E 45
  • Service 22DID 1E45
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 7 voltage CITIGO_HVBAT_CELL_7_V

  • Request22 1E 46
  • Service 22DID 1E46
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 8 voltage CITIGO_HVBAT_CELL_8_V

  • Request22 1E 47
  • Service 22DID 1E47
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 9 voltage CITIGO_HVBAT_CELL_9_V

  • Request22 1E 48
  • Service 22DID 1E48
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 10 voltage CITIGO_HVBAT_CELL_10_V

  • Request22 1E 49
  • Service 22DID 1E49
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 11 voltage CITIGO_HVBAT_CELL_11_V

  • Request22 1E 4A
  • Service 22DID 1E4A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 12 voltage CITIGO_HVBAT_CELL_12_V

  • Request22 1E 4B
  • Service 22DID 1E4B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 13 voltage CITIGO_HVBAT_CELL_13_V

  • Request22 1E 4C
  • Service 22DID 1E4C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 14 voltage CITIGO_HVBAT_CELL_14_V

  • Request22 1E 4D
  • Service 22DID 1E4D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 15 voltage CITIGO_HVBAT_CELL_15_V

  • Request22 1E 4E
  • Service 22DID 1E4E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 16 voltage CITIGO_HVBAT_CELL_16_V

  • Request22 1E 4F
  • Service 22DID 1E4F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 17 voltage CITIGO_HVBAT_CELL_17_V

  • Request22 1E 50
  • Service 22DID 1E50
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 18 voltage CITIGO_HVBAT_CELL_18_V

  • Request22 1E 51
  • Service 22DID 1E51
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 19 voltage CITIGO_HVBAT_CELL_19_V

  • Request22 1E 52
  • Service 22DID 1E52
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 20 voltage CITIGO_HVBAT_CELL_20_V

  • Request22 1E 53
  • Service 22DID 1E53
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 21 voltage CITIGO_HVBAT_CELL_21_V

  • Request22 1E 54
  • Service 22DID 1E54
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 22 voltage CITIGO_HVBAT_CELL_22_V

  • Request22 1E 55
  • Service 22DID 1E55
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 23 voltage CITIGO_HVBAT_CELL_23_V

  • Request22 1E 56
  • Service 22DID 1E56
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 24 voltage CITIGO_HVBAT_CELL_24_V

  • Request22 1E 57
  • Service 22DID 1E57
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 25 voltage CITIGO_HVBAT_CELL_25_V

  • Request22 1E 58
  • Service 22DID 1E58
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 26 voltage CITIGO_HVBAT_CELL_26_V

  • Request22 1E 59
  • Service 22DID 1E59
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 27 voltage CITIGO_HVBAT_CELL_27_V

  • Request22 1E 5A
  • Service 22DID 1E5A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 28 voltage CITIGO_HVBAT_CELL_28_V

  • Request22 1E 5B
  • Service 22DID 1E5B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 29 voltage CITIGO_HVBAT_CELL_29_V

  • Request22 1E 5C
  • Service 22DID 1E5C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 30 voltage CITIGO_HVBAT_CELL_30_V

  • Request22 1E 5D
  • Service 22DID 1E5D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 31 voltage CITIGO_HVBAT_CELL_31_V

  • Request22 1E 5E
  • Service 22DID 1E5E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 32 voltage CITIGO_HVBAT_CELL_32_V

  • Request22 1E 5F
  • Service 22DID 1E5F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 33 voltage CITIGO_HVBAT_CELL_33_V

  • Request22 1E 60
  • Service 22DID 1E60
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 34 voltage CITIGO_HVBAT_CELL_34_V

  • Request22 1E 61
  • Service 22DID 1E61
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 35 voltage CITIGO_HVBAT_CELL_35_V

  • Request22 1E 62
  • Service 22DID 1E62
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 36 voltage CITIGO_HVBAT_CELL_36_V

  • Request22 1E 63
  • Service 22DID 1E63
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 37 voltage CITIGO_HVBAT_CELL_37_V

  • Request22 1E 64
  • Service 22DID 1E64
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 38 voltage CITIGO_HVBAT_CELL_38_V

  • Request22 1E 65
  • Service 22DID 1E65
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 39 voltage CITIGO_HVBAT_CELL_39_V

  • Request22 1E 66
  • Service 22DID 1E66
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 40 voltage CITIGO_HVBAT_CELL_40_V

  • Request22 1E 67
  • Service 22DID 1E67
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 41 voltage CITIGO_HVBAT_CELL_41_V

  • Request22 1E 68
  • Service 22DID 1E68
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 42 voltage CITIGO_HVBAT_CELL_42_V

  • Request22 1E 69
  • Service 22DID 1E69
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 43 voltage CITIGO_HVBAT_CELL_43_V

  • Request22 1E 6A
  • Service 22DID 1E6A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 44 voltage CITIGO_HVBAT_CELL_44_V

  • Request22 1E 6B
  • Service 22DID 1E6B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 45 voltage CITIGO_HVBAT_CELL_45_V

  • Request22 1E 6C
  • Service 22DID 1E6C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 46 voltage CITIGO_HVBAT_CELL_46_V

  • Request22 1E 6D
  • Service 22DID 1E6D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 47 voltage CITIGO_HVBAT_CELL_47_V

  • Request22 1E 6E
  • Service 22DID 1E6E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 48 voltage CITIGO_HVBAT_CELL_48_V

  • Request22 1E 6F
  • Service 22DID 1E6F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 49 voltage CITIGO_HVBAT_CELL_49_V

  • Request22 1E 70
  • Service 22DID 1E70
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 50 voltage CITIGO_HVBAT_CELL_50_V

  • Request22 1E 71
  • Service 22DID 1E71
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 51 voltage CITIGO_HVBAT_CELL_51_V

  • Request22 1E 72
  • Service 22DID 1E72
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 52 voltage CITIGO_HVBAT_CELL_52_V

  • Request22 1E 73
  • Service 22DID 1E73
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 53 voltage CITIGO_HVBAT_CELL_53_V

  • Request22 1E 74
  • Service 22DID 1E74
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 54 voltage CITIGO_HVBAT_CELL_54_V

  • Request22 1E 75
  • Service 22DID 1E75
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 55 voltage CITIGO_HVBAT_CELL_55_V

  • Request22 1E 76
  • Service 22DID 1E76
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 56 voltage CITIGO_HVBAT_CELL_56_V

  • Request22 1E 77
  • Service 22DID 1E77
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 57 voltage CITIGO_HVBAT_CELL_57_V

  • Request22 1E 78
  • Service 22DID 1E78
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 58 voltage CITIGO_HVBAT_CELL_58_V

  • Request22 1E 79
  • Service 22DID 1E79
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 59 voltage CITIGO_HVBAT_CELL_59_V

  • Request22 1E 7A
  • Service 22DID 1E7A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 60 voltage CITIGO_HVBAT_CELL_60_V

  • Request22 1E 7B
  • Service 22DID 1E7B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 61 voltage CITIGO_HVBAT_CELL_61_V

  • Request22 1E 7C
  • Service 22DID 1E7C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 62 voltage CITIGO_HVBAT_CELL_62_V

  • Request22 1E 7D
  • Service 22DID 1E7D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 63 voltage CITIGO_HVBAT_CELL_63_V

  • Request22 1E 7E
  • Service 22DID 1E7E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 64 voltage CITIGO_HVBAT_CELL_64_V

  • Request22 1E 7F
  • Service 22DID 1E7F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 65 voltage CITIGO_HVBAT_CELL_65_V

  • Request22 1E 80
  • Service 22DID 1E80
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 66 voltage CITIGO_HVBAT_CELL_66_V

  • Request22 1E 81
  • Service 22DID 1E81
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 67 voltage CITIGO_HVBAT_CELL_67_V

  • Request22 1E 82
  • Service 22DID 1E82
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 68 voltage CITIGO_HVBAT_CELL_68_V

  • Request22 1E 83
  • Service 22DID 1E83
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 69 voltage CITIGO_HVBAT_CELL_69_V

  • Request22 1E 84
  • Service 22DID 1E84
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 70 voltage CITIGO_HVBAT_CELL_70_V

  • Request22 1E 85
  • Service 22DID 1E85
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 71 voltage CITIGO_HVBAT_CELL_71_V

  • Request22 1E 86
  • Service 22DID 1E86
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 72 voltage CITIGO_HVBAT_CELL_72_V

  • Request22 1E 87
  • Service 22DID 1E87
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 73 voltage CITIGO_HVBAT_CELL_73_V

  • Request22 1E 88
  • Service 22DID 1E88
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 74 voltage CITIGO_HVBAT_CELL_74_V

  • Request22 1E 89
  • Service 22DID 1E89
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 75 voltage CITIGO_HVBAT_CELL_75_V

  • Request22 1E 8A
  • Service 22DID 1E8A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 76 voltage CITIGO_HVBAT_CELL_76_V

  • Request22 1E 8B
  • Service 22DID 1E8B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 77 voltage CITIGO_HVBAT_CELL_77_V

  • Request22 1E 8C
  • Service 22DID 1E8C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 78 voltage CITIGO_HVBAT_CELL_78_V

  • Request22 1E 8D
  • Service 22DID 1E8D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 79 voltage CITIGO_HVBAT_CELL_79_V

  • Request22 1E 8E
  • Service 22DID 1E8E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 80 voltage CITIGO_HVBAT_CELL_80_V

  • Request22 1E 8F
  • Service 22DID 1E8F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 81 voltage CITIGO_HVBAT_CELL_81_V

  • Request22 1E 90
  • Service 22DID 1E90
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 82 voltage CITIGO_HVBAT_CELL_82_V

  • Request22 1E 91
  • Service 22DID 1E91
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 83 voltage CITIGO_HVBAT_CELL_83_V

  • Request22 1E 92
  • Service 22DID 1E92
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 84 voltage CITIGO_HVBAT_CELL_84_V

  • Request22 1E 93
  • Service 22DID 1E93
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 85 voltage CITIGO_HVBAT_CELL_85_V

  • Request22 1E 94
  • Service 22DID 1E94
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 86 voltage CITIGO_HVBAT_CELL_86_V

  • Request22 1E 95
  • Service 22DID 1E95
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 87 voltage CITIGO_HVBAT_CELL_87_V

  • Request22 1E 96
  • Service 22DID 1E96
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 88 voltage CITIGO_HVBAT_CELL_88_V

  • Request22 1E 97
  • Service 22DID 1E97
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 89 voltage CITIGO_HVBAT_CELL_89_V

  • Request22 1E 98
  • Service 22DID 1E98
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 90 voltage CITIGO_HVBAT_CELL_90_V

  • Request22 1E 99
  • Service 22DID 1E99
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 91 voltage CITIGO_HVBAT_CELL_91_V

  • Request22 1E 9A
  • Service 22DID 1E9A
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 92 voltage CITIGO_HVBAT_CELL_92_V

  • Request22 1E 9B
  • Service 22DID 1E9B
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 93 voltage CITIGO_HVBAT_CELL_93_V

  • Request22 1E 9C
  • Service 22DID 1E9C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 94 voltage CITIGO_HVBAT_CELL_94_V

  • Request22 1E 9D
  • Service 22DID 1E9D
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 95 voltage CITIGO_HVBAT_CELL_95_V

  • Request22 1E 9E
  • Service 22DID 1E9E
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 96 voltage CITIGO_HVBAT_CELL_96_V

  • Request22 1E 9F
  • Service 22DID 1E9F
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 97 voltage CITIGO_HVBAT_CELL_97_V

  • Request22 1E A0
  • Service 22DID 1EA0
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 98 voltage CITIGO_HVBAT_CELL_98_V

  • Request22 1E A1
  • Service 22DID 1EA1
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 99 voltage CITIGO_HVBAT_CELL_99_V

  • Request22 1E A2
  • Service 22DID 1EA2
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 100 voltage CITIGO_HVBAT_CELL_100_V

  • Request22 1E A3
  • Service 22DID 1EA3
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 101 voltage CITIGO_HVBAT_CELL_101_V

  • Request22 1E A4
  • Service 22DID 1EA4
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell 102 voltage CITIGO_HVBAT_CELL_102_V

  • Request22 1E A5
  • Service 22DID 1EA5
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell voltage sum CITIGO_HVBAT_CELL_SUM_V

  • Request22 1E 3C
  • Service 22DID 1E3C
  • Module7E5
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 4096)
Range
0 to 4095.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell voltage, maximum CITIGO_HVBAT_CELL_V_MAX

  • Request22 1E 33
  • Service 22DID 1E33
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery cell voltage, minimum CITIGO_HVBAT_CELL_V_MIN

  • Request22 1E 34
  • Service 22DID 1E34
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.999 V
Unit
V

In testing for 2019 to 2020.

HV battery charge CITIGO_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Request22 02 8C
  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2020.

HV battery charge current limit CITIGO_HVBAT_CHG_I_LIM

  • Request22 1E 1B
  • Service 22DID 1E1B
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2019 to 2020.

HV battery charge current limit, predicted CITIGO_HVBAT_CHG_I_LIM_PRED

  • Request22 1E 1D
  • Service 22DID 1E1D
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2019 to 2020.

HV battery charge throughput CITIGO_HVBAT_AH_CHG

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 549.31642)
Range
0 to 7818700 Ah
Unit
Ah

In testing for 2019 to 2020.

HV battery charge, displayed CITIGO_HVBAT_SOC_DISP

Pelican can show this parameter as the state of charge.

  • Request22 11 64
  • Service 22DID 1164
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2020.

HV battery charge, normalized CITIGO_PE_SOC

  • Request22 F4 04
  • Service 22DID F404
  • Module7E6
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2020.

HV battery coldest sensor CITIGO_HVBAT_T_MIN_NO

  • Request22 1E 0F
  • Service 22DID 1E0F
  • Module7E5
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2020.

HV battery current CITIGO_HVBAT_I

Pelican can show this parameter as the traction battery current.

  • Request22 1E 3D
  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4 − 511)
Range
-200 to 200 A
Unit
A

In testing for 2019 to 2020.

HV battery discharge current limit CITIGO_HVBAT_DISCHG_I_LIM

  • Request22 1E 1C
  • Service 22DID 1E1C
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2019 to 2020.

HV battery discharge current limit, predicted CITIGO_HVBAT_DISCHG_I_LIM_PRED

  • Request22 1E 1E
  • Service 22DID 1E1E
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2019 to 2020.

HV battery discharge throughput CITIGO_HVBAT_AH_DISCHG

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 32 to 63 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 549.31642)
Range
-3909350 to 3909350 Ah
Unit
Ah

In testing for 2019 to 2020.

HV battery energy CITIGO_HVBAT_KWH

Energy stored in the high voltage battery

  • Request22 2A B8
  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1310770)
Range
0 to 3276 kWh
Unit
kWh

In testing for 2019 to 2020.

HV battery energy charged CITIGO_HVBAT_KWH_CHG

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
(val ÷ 8583.07212)
Range
0 to 500300 kWh
Unit
kWh

In testing for 2019 to 2020.

HV battery energy discharged CITIGO_HVBAT_KWH_DISCHG

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every3600 s
  • Testing

Bits 96 to 127 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 8583.07212)
Range
-250199.883 to 250199.883 kWh
Unit
kWh

In testing for 2019 to 2020.

HV battery health CITIGO_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Request22 51 E0
  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.127 − 1798.574)
Range
-1798.574 to 100 %
Unit
%

In testing for 2019 to 2020.

HV battery highest cell CITIGO_HVBAT_CELL_V_MAX_NO

  • Request22 1E 33
  • Service 22DID 1E33
  • Module7E5
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2020.

HV battery hottest sensor CITIGO_HVBAT_T_MAX_NO

  • Request22 1E 0E
  • Service 22DID 1E0E
  • Module7E5
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2020.

HV battery isolation resistance, negative CITIGO_HVBAT_ISO_NEG

  • Request22 1E 1A
  • Service 22DID 1E1A
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2019 to 2020.

HV battery isolation resistance, positive CITIGO_HVBAT_ISO_POS

  • Request22 1E 18
  • Service 22DID 1E18
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2019 to 2020.

HV battery lowest cell CITIGO_HVBAT_CELL_V_MIN_NO

  • Request22 1E 34
  • Service 22DID 1E34
  • Module7E5
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2020.

HV battery maximum power CITIGO_HVBAT_PWR_MAX

  • Request22 15 02
  • Service 22DID 1502
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 4)
Range
0 to 262140 W
Unit
W

In testing for 2019 to 2020.

HV battery negative voltage before the contactors CITIGO_HVBAT_NEG_V_PRE

  • Request22 1E 35
  • Service 22DID 1E35
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1024 to 1023.968 V
Unit
V

In testing for 2019 to 2020.

HV battery positive voltage after the charging contactors CITIGO_HVBAT_POS_V_POST_CHG

  • Request22 1E 39
  • Service 22DID 1E39
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.937 V
Unit
V

In testing for 2019 to 2020.

HV battery positive voltage before the contactors CITIGO_HVBAT_POS_V_PRE

  • Request22 1E 36
  • Service 22DID 1E36
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.968 V
Unit
V

In testing for 2019 to 2020.

HV battery power CITIGO_HVBAT_PWR

  • Request22 14 85
  • Service 22DID 1485
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 250)
Range
-131.072 to 131.068 kW
Unit
kW

In testing for 2019 to 2020.

HV battery relative temperature CITIGO_HVBAT_T_REL

  • Request22 14 9B
  • Service 22DID 149B
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 %
Unit
%

In testing for 2019 to 2020.

HV battery remaining charge CITIGO_HVBAT_REMAINING

  • Request22 F4 5B
  • Service 22DID F45B
  • Module7E0
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2020.

HV battery temperature CITIGO_HVBAT_T

  • Request22 2A 0B
  • Service 22DID 2A0B
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature load CITIGO_HVBAT_T_LOAD

  • Request22 11 65
  • Service 22DID 1165
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 %
Unit
%

In testing for 2019 to 2020.

HV battery temperature sensor 1 CITIGO_HVBAT_T_1

  • Request22 1E AE
  • Service 22DID 1EAE
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 2 CITIGO_HVBAT_T_2

  • Request22 1E AF
  • Service 22DID 1EAF
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 3 CITIGO_HVBAT_T_3

  • Request22 1E B0
  • Service 22DID 1EB0
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 4 CITIGO_HVBAT_T_4

  • Request22 1E B1
  • Service 22DID 1EB1
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 5 CITIGO_HVBAT_T_5

  • Request22 1E B2
  • Service 22DID 1EB2
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 6 CITIGO_HVBAT_T_6

  • Request22 1E B3
  • Service 22DID 1EB3
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 7 CITIGO_HVBAT_T_7

  • Request22 1E B4
  • Service 22DID 1EB4
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 8 CITIGO_HVBAT_T_8

  • Request22 1E B5
  • Service 22DID 1EB5
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 9 CITIGO_HVBAT_T_9

  • Request22 1E B6
  • Service 22DID 1EB6
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 10 CITIGO_HVBAT_T_10

  • Request22 1E B7
  • Service 22DID 1EB7
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 11 CITIGO_HVBAT_T_11

  • Request22 1E B8
  • Service 22DID 1EB8
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 12 CITIGO_HVBAT_T_12

  • Request22 1E B9
  • Service 22DID 1EB9
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 13 CITIGO_HVBAT_T_13

  • Request22 1E BA
  • Service 22DID 1EBA
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 15 CITIGO_HVBAT_T_15

  • Request22 1E BC
  • Service 22DID 1EBC
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 16 CITIGO_HVBAT_T_16

  • Request22 1E BD
  • Service 22DID 1EBD
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature sensor 17 CITIGO_HVBAT_T_17

  • Request22 74 25
  • Service 22DID 7425
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery temperature, maximum CITIGO_HVBAT_T_MAX

  • Request22 1E 0E
  • Service 22DID 1E0E
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.984 °C
Unit
°C

In testing for 2019 to 2020.

HV battery voltage CITIGO_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 1E 3B
  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 1000 V
Unit
V

In testing for 2019 to 2020.

HV interlock detector voltage CITIGO_HV_INTERLOCK_DET_V

  • Request22 74 B9
  • Service 22DID 74B9
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 3276)
Range
0 to 20.004 V
Unit
V

In testing for 2019 to 2020.

HV interlock source current CITIGO_HV_INTERLOCK_SRC_I

  • Request22 74 BC
  • Service 22DID 74BC
  • Module7E5
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.999 mA
Unit
mA

In testing for 2019 to 2020.

HV interlock source voltage CITIGO_HV_INTERLOCK_SRC_V

  • Request22 74 BA
  • Service 22DID 74BA
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 3276)
Range
0 to 20.004 V
Unit
V

In testing for 2019 to 2020.

HV system isolation resistance, negative CITIGO_HV_ISO_NEG_SYS

  • Request22 1E 19
  • Service 22DID 1E19
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2019 to 2020.

HV system isolation resistance, positive CITIGO_HV_ISO_POS_SYS

  • Request22 1E 17
  • Service 22DID 1E17
  • Module7E5
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kΩ
Unit
kΩ

In testing for 2019 to 2020.

Onboard electrical system current CITIGO_AUX_I

  • Request22 16 17
  • Service 22DID 1617
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1024 to 1023.968 A
Unit
A

In testing for 2019 to 2020.

Onboard electrical system power CITIGO_AUX_PWR

  • Request22 10 77
  • Service 22DID 1077
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 4)
Range
0 to 262140 W
Unit
W

In testing for 2019 to 2020.

Power electronics terminal 30 voltage CITIGO_PE_KL30_V

  • Request22 46 5D
  • Service 22DID 465D
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 512)
Range
-64 to 63.998 V
Unit
V

In testing for 2019 to 2020.

Terminal 30 voltage CITIGO_KL30_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 F4 42
  • Service 22DID F442
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65 V
Unit
V

In testing for 2019 to 2020.

Traction current reported by the battery management system CITIGO_PE_BMS_HV_I

  • Request22 46 5F
  • Service 22DID 465F
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.937 A
Unit
A

In testing for 2019 to 2020.

Traction voltage reported by the battery management system CITIGO_PE_BMS_HV_V

  • Request22 46 6E
  • Service 22DID 466E
  • Module7E6
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.968 V
Unit
V

In testing for 2019 to 2020.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.