Battery parameters
The Renault Clio III has 245 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
AC charging power available RENAULT_AC_P_AVAIL
- Request
22 30 0F - Service 22
DID 300F - Module
DADA → DA - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40)- Range
- 0 to 1638.375 kW
- Unit
- kW
In testing for 2005 to 2014.
AC mains current RENAULT_AC_A
- Request
22 30 0D - Service 22
DID 300D - Module
DADA → DA - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2005 to 2014.
AC mains phases RENAULT_AC_PHASES
- Request
22 30 0B - Service 22
DID 300B - Module
DADA → DA - Every
2 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | ONE | One phase |
1 | TWO | Two phase |
2 | THREE | Three phase |
3 | NONE | Not detected |
In testing for 2005 to 2014.
AC mains voltage RENAULT_AC_V
- Request
22 2B 8A - Service 22
DID 2B8A - Module
DADA → DA - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 2005 to 2014.
Battery module 1 temperature RENAULT_MOD_T1
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 2 temperature RENAULT_MOD_T2
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 3 temperature RENAULT_MOD_T3
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 4 temperature RENAULT_MOD_T4
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 5 temperature RENAULT_MOD_T5
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 6 temperature RENAULT_MOD_T6
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 7 temperature RENAULT_MOD_T7
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 8 temperature RENAULT_MOD_T8
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 9 temperature RENAULT_MOD_T9
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 10 temperature RENAULT_MOD_T10
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 11 temperature RENAULT_MOD_T11
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery module 12 temperature RENAULT_MOD_T12
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
60 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2014.
Battery voltage, 12V RENAULT_12V_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 30 01 - Service 22
DID 3001 - Module
748 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2005 to 2014.
Charge plug present RENAULT_PLUG
Pelican can show this parameter as the plug state.
- Request
22 2B 85 - Service 22
DID 2B85 - Module
DADA → DA - Every
2 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2005 to 2014.
Charge state RENAULT_CHG_STATE
- Request
22 2B 6D - Service 22
DID 2B6D - Module
DADA → DA - Every
2 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STOPPED | Stopped |
1 | TIMER_WAIT | Waiting for timer |
2 | DONE | Done |
3 | CHARGING | Battery |
4 | INTERRUPTED | Interrupted |
5 | POWER_WAIT | Waiting for power |
6 | FLAP_OPEN | Charge flap open |
8 | PREPARING | Preparing |
In testing for 2005 to 2014.
Charge type RENAULT_CHG_TYPE
- Request
22 2B 7A - Service 22
DID 2B7A - Module
DADA → DA - Every
2 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | UNDEFINED | Undefined |
1 | TYPE2 | Type 2 |
2 | TYPE2 | Type 2 |
3 | CHADEMO | CHAdeMO |
4 | CCS |
In testing for 2005 to 2014.
Complete charge cycles RENAULT_CYCLES
- Request
22 92 10 - Service 22
DID 9210 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2005 to 2014.
Computer supply voltage RENAULT_ECU_V
- Request
22 01 2F - Service 22
DID 012F - Module
740 → 760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2005 to 2014.
Energy charged, total RENAULT_E_CHG
- Request
22 92 43 - Service 22
DID 9243 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
In testing for 2005 to 2014.
Energy discharged, total RENAULT_E_DISCHG
- Request
22 92 45 - Service 22
DID 9245 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
In testing for 2005 to 2014.
Energy regenerated, total RENAULT_E_REGEN
- Request
22 92 47 - Service 22
DID 9247 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967.295 kWh
- Unit
- kWh
In testing for 2005 to 2014.
High voltage battery available energy RENAULT_HV_E_AVAIL
- Request
22 91 C8 - Service 22
DID 91C8 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 16777.215 kWh
- Unit
- kWh
In testing for 2005 to 2014.
High voltage battery average temperature RENAULT_HV_T
- Request
22 90 12 - Service 22
DID 9012 - Module
DADB → DB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
High voltage battery current RENAULT_HV_A
Pelican can show this parameter as the traction battery current.
- Request
22 92 5D - Service 22
DID 925D - Module
DADB → DB - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × -1 ÷ 32 + 1020)- Range
- -1027.97 to 1020 A
- Unit
- A
In testing for 2005 to 2014.
High voltage battery current RENAULT_HV_A_3042
- Request
22 30 42 - Service 22
DID 3042 - Module
DADA → DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 16383.75)- Range
- -16383.75 to 16383.75 A
- Unit
- A
In testing for 2005 to 2014.
High voltage battery current, power electronics RENAULT_HV_A_PEB
- Request
22 32 04 - Service 22
DID 3204 - Module
7E4 → 7EC - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 8192)- Range
- -8192 to 8191.75 A
- Unit
- A
In testing for 2005 to 2014.
High voltage battery current, vehicle controller RENAULT_HV_A_EVC
- Request
22 21 CC - Service 22
DID 21CC - Module
DADA → DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 500)- Range
- -500 to 15883.75 A
- Unit
- A
In testing for 2005 to 2014.
High voltage battery voltage RENAULT_HV_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 90 05 - Service 22
DID 9005 - Module
DADB → DB - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2005 to 2014.
High voltage battery voltage, power electronics RENAULT_HV_V_PEB
- Request
22 32 03 - Service 22
DID 3203 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 2005 to 2014.
High voltage battery voltage, vehicle controller RENAULT_HV_V_EVC
- Request
22 20 FE - Service 22
DID 20FE - Module
DADA → DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2005 to 2014.
Maximum charge power RENAULT_CHG_P_MAX
- Request
22 90 18 - Service 22
DID 9018 - Module
DADB → DB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kW
- Unit
- kW
In testing for 2005 to 2014.
Pack temperature 1 RENAULT_PACK_T1
- Request
22 91 31 - Service 22
DID 9131 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 2 RENAULT_PACK_T2
- Request
22 91 32 - Service 22
DID 9132 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 3 RENAULT_PACK_T3
- Request
22 91 33 - Service 22
DID 9133 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 4 RENAULT_PACK_T4
- Request
22 91 34 - Service 22
DID 9134 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 5 RENAULT_PACK_T5
- Request
22 91 35 - Service 22
DID 9135 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 6 RENAULT_PACK_T6
- Request
22 91 36 - Service 22
DID 9136 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 7 RENAULT_PACK_T7
- Request
22 91 37 - Service 22
DID 9137 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 8 RENAULT_PACK_T8
- Request
22 91 38 - Service 22
DID 9138 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 9 RENAULT_PACK_T9
- Request
22 91 39 - Service 22
DID 9139 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 10 RENAULT_PACK_T10
- Request
22 91 3A - Service 22
DID 913A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 11 RENAULT_PACK_T11
- Request
22 91 3B - Service 22
DID 913B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
Pack temperature 12 RENAULT_PACK_T12
- Request
22 91 3C - Service 22
DID 913C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055.9375 °C
- Unit
- °C
In testing for 2005 to 2014.
State of charge RENAULT_SOC
Pelican can show this parameter as the state of charge.
- Request
22 90 02 - Service 22
DID 9002 - Module
DADB → DB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2005 to 2014.
State of charge RENAULT_SOC_9002
- Request
22 90 02 - Service 22
DID 9002 - Module
DADA → DA - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2005 to 2014.
State of charge, battery controller RENAULT_SOC_9001
- Request
22 90 01 - Service 22
DID 9001 - Module
DADB → DB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2005 to 2014.
State of charge, vehicle controller RENAULT_SOC_EVC
- Request
22 20 02 - Service 22
DID 2002 - Module
DADA → DA - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 %
- Unit
- %
In testing for 2005 to 2014.
State of health RENAULT_SOH
Pelican can show this parameter as the state of health.
- Request
22 90 03 - Service 22
DID 9003 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2005 to 2014.
Supply voltage, ECU RENAULT_ECU_SUPPLY_V
- Request
22 20 05 - Service 22
DID 2005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2005 to 2014.
Battery › Cells
Cell 1 voltage RENAULT_CELL_V1
- Request
22 90 21 - Service 22
DID 9021 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 1 voltage RENAULT_CELL1_V1
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 2 voltage RENAULT_CELL_V2
- Request
22 90 22 - Service 22
DID 9022 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 2 voltage RENAULT_CELL1_V2
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 3 voltage RENAULT_CELL_V3
- Request
22 90 23 - Service 22
DID 9023 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 3 voltage RENAULT_CELL1_V3
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 4 voltage RENAULT_CELL_V4
- Request
22 90 24 - Service 22
DID 9024 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 4 voltage RENAULT_CELL1_V4
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 5 voltage RENAULT_CELL_V5
- Request
22 90 25 - Service 22
DID 9025 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 5 voltage RENAULT_CELL1_V5
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 6 voltage RENAULT_CELL_V6
- Request
22 90 26 - Service 22
DID 9026 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 6 voltage RENAULT_CELL1_V6
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 7 voltage RENAULT_CELL_V7
- Request
22 90 27 - Service 22
DID 9027 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 7 voltage RENAULT_CELL1_V7
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 8 voltage RENAULT_CELL_V8
- Request
22 90 28 - Service 22
DID 9028 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 8 voltage RENAULT_CELL1_V8
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 9 voltage RENAULT_CELL_V9
- Request
22 90 29 - Service 22
DID 9029 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 9 voltage RENAULT_CELL1_V9
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 10 voltage RENAULT_CELL_V10
- Request
22 90 2A - Service 22
DID 902A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 10 voltage RENAULT_CELL1_V10
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 11 voltage RENAULT_CELL_V11
- Request
22 90 2B - Service 22
DID 902B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 11 voltage RENAULT_CELL1_V11
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 12 voltage RENAULT_CELL_V12
- Request
22 90 2C - Service 22
DID 902C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 12 voltage RENAULT_CELL1_V12
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 13 voltage RENAULT_CELL_V13
- Request
22 90 2D - Service 22
DID 902D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 13 voltage RENAULT_CELL1_V13
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 14 voltage RENAULT_CELL_V14
- Request
22 90 2E - Service 22
DID 902E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 14 voltage RENAULT_CELL1_V14
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 15 voltage RENAULT_CELL_V15
- Request
22 90 2F - Service 22
DID 902F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 15 voltage RENAULT_CELL1_V15
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 16 voltage RENAULT_CELL_V16
- Request
22 90 30 - Service 22
DID 9030 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 16 voltage RENAULT_CELL1_V16
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 17 voltage RENAULT_CELL_V17
- Request
22 90 31 - Service 22
DID 9031 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 17 voltage RENAULT_CELL1_V17
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 18 voltage RENAULT_CELL_V18
- Request
22 90 32 - Service 22
DID 9032 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 18 voltage RENAULT_CELL1_V18
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 19 voltage RENAULT_CELL_V19
- Request
22 90 33 - Service 22
DID 9033 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 19 voltage RENAULT_CELL1_V19
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 20 voltage RENAULT_CELL_V20
- Request
22 90 34 - Service 22
DID 9034 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 20 voltage RENAULT_CELL1_V20
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 21 voltage RENAULT_CELL_V21
- Request
22 90 35 - Service 22
DID 9035 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 21 voltage RENAULT_CELL1_V21
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 22 voltage RENAULT_CELL_V22
- Request
22 90 36 - Service 22
DID 9036 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 22 voltage RENAULT_CELL1_V22
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 23 voltage RENAULT_CELL_V23
- Request
22 90 37 - Service 22
DID 9037 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 23 voltage RENAULT_CELL1_V23
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 24 voltage RENAULT_CELL_V24
- Request
22 90 38 - Service 22
DID 9038 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 24 voltage RENAULT_CELL1_V24
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 25 voltage RENAULT_CELL_V25
- Request
22 90 39 - Service 22
DID 9039 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 25 voltage RENAULT_CELL1_V25
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 26 voltage RENAULT_CELL_V26
- Request
22 90 3A - Service 22
DID 903A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 26 voltage RENAULT_CELL1_V26
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 27 voltage RENAULT_CELL_V27
- Request
22 90 3B - Service 22
DID 903B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 27 voltage RENAULT_CELL1_V27
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 28 voltage RENAULT_CELL_V28
- Request
22 90 3C - Service 22
DID 903C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 28 voltage RENAULT_CELL1_V28
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 29 voltage RENAULT_CELL_V29
- Request
22 90 3D - Service 22
DID 903D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 29 voltage RENAULT_CELL1_V29
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 30 voltage RENAULT_CELL_V30
- Request
22 90 3E - Service 22
DID 903E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 30 voltage RENAULT_CELL1_V30
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 31 voltage RENAULT_CELL_V31
- Request
22 90 3F - Service 22
DID 903F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 31 voltage RENAULT_CELL1_V31
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 32 voltage RENAULT_CELL_V32
- Request
22 90 41 - Service 22
DID 9041 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 32 voltage RENAULT_CELL1_V32
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 33 voltage RENAULT_CELL_V33
- Request
22 90 42 - Service 22
DID 9042 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 33 voltage RENAULT_CELL1_V33
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 34 voltage RENAULT_CELL_V34
- Request
22 90 43 - Service 22
DID 9043 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 34 voltage RENAULT_CELL1_V34
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 35 voltage RENAULT_CELL_V35
- Request
22 90 44 - Service 22
DID 9044 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 35 voltage RENAULT_CELL1_V35
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 36 voltage RENAULT_CELL_V36
- Request
22 90 45 - Service 22
DID 9045 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 36 voltage RENAULT_CELL1_V36
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 37 voltage RENAULT_CELL_V37
- Request
22 90 46 - Service 22
DID 9046 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 37 voltage RENAULT_CELL1_V37
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 38 voltage RENAULT_CELL_V38
- Request
22 90 47 - Service 22
DID 9047 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 38 voltage RENAULT_CELL1_V38
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 39 voltage RENAULT_CELL_V39
- Request
22 90 48 - Service 22
DID 9048 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 39 voltage RENAULT_CELL1_V39
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 40 voltage RENAULT_CELL_V40
- Request
22 90 49 - Service 22
DID 9049 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 40 voltage RENAULT_CELL1_V40
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 41 voltage RENAULT_CELL_V41
- Request
22 90 4A - Service 22
DID 904A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 41 voltage RENAULT_CELL1_V41
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 42 voltage RENAULT_CELL_V42
- Request
22 90 4B - Service 22
DID 904B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 42 voltage RENAULT_CELL1_V42
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 43 voltage RENAULT_CELL_V43
- Request
22 90 4C - Service 22
DID 904C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 43 voltage RENAULT_CELL1_V43
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 44 voltage RENAULT_CELL_V44
- Request
22 90 4D - Service 22
DID 904D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 44 voltage RENAULT_CELL1_V44
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 45 voltage RENAULT_CELL_V45
- Request
22 90 4E - Service 22
DID 904E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 45 voltage RENAULT_CELL1_V45
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 46 voltage RENAULT_CELL_V46
- Request
22 90 4F - Service 22
DID 904F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 46 voltage RENAULT_CELL1_V46
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 47 voltage RENAULT_CELL_V47
- Request
22 90 50 - Service 22
DID 9050 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 47 voltage RENAULT_CELL1_V47
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 48 voltage RENAULT_CELL_V48
- Request
22 90 51 - Service 22
DID 9051 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 48 voltage RENAULT_CELL1_V48
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 49 voltage RENAULT_CELL_V49
- Request
22 90 52 - Service 22
DID 9052 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 49 voltage RENAULT_CELL1_V49
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 50 voltage RENAULT_CELL_V50
- Request
22 90 53 - Service 22
DID 9053 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 50 voltage RENAULT_CELL1_V50
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 51 voltage RENAULT_CELL_V51
- Request
22 90 54 - Service 22
DID 9054 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 51 voltage RENAULT_CELL1_V51
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 52 voltage RENAULT_CELL_V52
- Request
22 90 55 - Service 22
DID 9055 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 52 voltage RENAULT_CELL1_V52
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 53 voltage RENAULT_CELL_V53
- Request
22 90 56 - Service 22
DID 9056 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 53 voltage RENAULT_CELL1_V53
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 54 voltage RENAULT_CELL_V54
- Request
22 90 57 - Service 22
DID 9057 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 54 voltage RENAULT_CELL1_V54
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 55 voltage RENAULT_CELL_V55
- Request
22 90 58 - Service 22
DID 9058 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 55 voltage RENAULT_CELL1_V55
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 56 voltage RENAULT_CELL_V56
- Request
22 90 59 - Service 22
DID 9059 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 56 voltage RENAULT_CELL1_V56
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 57 voltage RENAULT_CELL_V57
- Request
22 90 5A - Service 22
DID 905A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 57 voltage RENAULT_CELL1_V57
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 58 voltage RENAULT_CELL_V58
- Request
22 90 5B - Service 22
DID 905B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 58 voltage RENAULT_CELL1_V58
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 59 voltage RENAULT_CELL_V59
- Request
22 90 5C - Service 22
DID 905C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 59 voltage RENAULT_CELL1_V59
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 60 voltage RENAULT_CELL_V60
- Request
22 90 5D - Service 22
DID 905D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 60 voltage RENAULT_CELL1_V60
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 61 voltage RENAULT_CELL_V61
- Request
22 90 5E - Service 22
DID 905E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 61 voltage RENAULT_CELL1_V61
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 62 voltage RENAULT_CELL_V62
- Request
22 90 5F - Service 22
DID 905F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 62 voltage RENAULT_CELL1_V62
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 63 voltage RENAULT_CELL_V63
- Request
22 90 61 - Service 22
DID 9061 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 63 voltage RENAULT_CELL1_V63
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 64 voltage RENAULT_CELL_V64
- Request
22 90 62 - Service 22
DID 9062 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 64 voltage RENAULT_CELL1_V64
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 65 voltage RENAULT_CELL_V65
- Request
22 90 63 - Service 22
DID 9063 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 65 voltage RENAULT_CELL1_V65
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 66 voltage RENAULT_CELL_V66
- Request
22 90 64 - Service 22
DID 9064 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 66 voltage RENAULT_CELL1_V66
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 67 voltage RENAULT_CELL_V67
- Request
22 90 65 - Service 22
DID 9065 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 67 voltage RENAULT_CELL1_V67
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 68 voltage RENAULT_CELL_V68
- Request
22 90 66 - Service 22
DID 9066 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 68 voltage RENAULT_CELL1_V68
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 69 voltage RENAULT_CELL_V69
- Request
22 90 67 - Service 22
DID 9067 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 69 voltage RENAULT_CELL1_V69
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 70 voltage RENAULT_CELL_V70
- Request
22 90 68 - Service 22
DID 9068 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 70 voltage RENAULT_CELL1_V70
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 71 voltage RENAULT_CELL_V71
- Request
22 90 69 - Service 22
DID 9069 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 71 voltage RENAULT_CELL1_V71
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 72 voltage RENAULT_CELL_V72
- Request
22 90 6A - Service 22
DID 906A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 72 voltage RENAULT_CELL1_V72
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 73 voltage RENAULT_CELL_V73
- Request
22 90 6B - Service 22
DID 906B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 73 voltage RENAULT_CELL1_V73
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 74 voltage RENAULT_CELL_V74
- Request
22 90 6C - Service 22
DID 906C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 74 voltage RENAULT_CELL1_V74
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 75 voltage RENAULT_CELL_V75
- Request
22 90 6D - Service 22
DID 906D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 75 voltage RENAULT_CELL1_V75
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 76 voltage RENAULT_CELL_V76
- Request
22 90 6E - Service 22
DID 906E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 76 voltage RENAULT_CELL1_V76
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 77 voltage RENAULT_CELL_V77
- Request
22 90 6F - Service 22
DID 906F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 77 voltage RENAULT_CELL1_V77
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 78 voltage RENAULT_CELL_V78
- Request
22 90 70 - Service 22
DID 9070 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 78 voltage RENAULT_CELL1_V78
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 79 voltage RENAULT_CELL_V79
- Request
22 90 71 - Service 22
DID 9071 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 79 voltage RENAULT_CELL1_V79
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 80 voltage RENAULT_CELL_V80
- Request
22 90 72 - Service 22
DID 9072 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 80 voltage RENAULT_CELL1_V80
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 81 voltage RENAULT_CELL_V81
- Request
22 90 73 - Service 22
DID 9073 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 81 voltage RENAULT_CELL1_V81
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 82 voltage RENAULT_CELL_V82
- Request
22 90 74 - Service 22
DID 9074 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 82 voltage RENAULT_CELL1_V82
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 83 voltage RENAULT_CELL_V83
- Request
22 90 75 - Service 22
DID 9075 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 83 voltage RENAULT_CELL1_V83
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 84 voltage RENAULT_CELL_V84
- Request
22 90 76 - Service 22
DID 9076 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 84 voltage RENAULT_CELL1_V84
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 85 voltage RENAULT_CELL_V85
- Request
22 90 77 - Service 22
DID 9077 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 85 voltage RENAULT_CELL1_V85
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 86 voltage RENAULT_CELL_V86
- Request
22 90 78 - Service 22
DID 9078 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 86 voltage RENAULT_CELL1_V86
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 87 voltage RENAULT_CELL_V87
- Request
22 90 79 - Service 22
DID 9079 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 87 voltage RENAULT_CELL1_V87
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 88 voltage RENAULT_CELL_V88
- Request
22 90 7A - Service 22
DID 907A - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 88 voltage RENAULT_CELL1_V88
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 89 voltage RENAULT_CELL_V89
- Request
22 90 7B - Service 22
DID 907B - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 89 voltage RENAULT_CELL1_V89
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 90 voltage RENAULT_CELL_V90
- Request
22 90 7C - Service 22
DID 907C - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 90 voltage RENAULT_CELL1_V90
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 91 voltage RENAULT_CELL_V91
- Request
22 90 7D - Service 22
DID 907D - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 91 voltage RENAULT_CELL1_V91
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 92 voltage RENAULT_CELL_V92
- Request
22 90 7E - Service 22
DID 907E - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 92 voltage RENAULT_CELL1_V92
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 93 voltage RENAULT_CELL_V93
- Request
22 90 7F - Service 22
DID 907F - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 93 voltage RENAULT_CELL1_V93
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 94 voltage RENAULT_CELL_V94
- Request
22 90 81 - Service 22
DID 9081 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 94 voltage RENAULT_CELL1_V94
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 95 voltage RENAULT_CELL_V95
- Request
22 90 82 - Service 22
DID 9082 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 95 voltage RENAULT_CELL1_V95
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.
Cell 96 voltage RENAULT_CELL_V96
- Request
22 90 83 - Service 22
DID 9083 - Module
DADB → DB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2005 to 2014.
Cell 96 voltage RENAULT_CELL1_V96
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2005 to 2014.