Nissan Versa

Fuel parameters

The Nissan Versa has 10 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Air/fuel ratio adjustment, bank 2 NISSAN_AF_ADJ_B2

  • Request22 11 24
  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 100)
Range
-100 to 155 %
Unit
%

In testing for 2006 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Air/fuel ratio adjustment, bank 2 NISSAN_AF_ADJ_B2

  • Request22 11 24
  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 100)
Range
-100 to 155 %
Unit
%

In testing for 2006 to 2026.

Fuel level input NISSAN_FLI_INPUT

  • Request22 11 14
  • Service 22DID 1114
  • ModuleDA18 → 18
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 25)
Range
0 to 10.2 V
Unit
V

In testing for 2006 to 2026.

Fuel pump flow NISSAN_FUEL_PMP_FLOW

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 8)
Range
0 to 31.87 g/s
Unit
g/s

In testing for 2006 to 2026.

Fuel rail temperature NISSAN_FUEL_RAIL_T

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2006 to 2026.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2012, 2017. Supported for 2010, 2016, 2021, 2024.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2012, 2017. Supported for 2010, 2016, 2021, 2024.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2012, 2017, 2021. Supported for 2010, 2024.

Fuel tank temperature NISSAN_FUEL_TANK_T

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2006 to 2026.

Fuel temperature NISSAN_FUEL_T

  • Request22 11 11
  • Service 22DID 1111
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2006 to 2026.

Remaining fuel NISSAN_REMAINING_FUEL

  • Request22 11 86
  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2006 to 2011, 2013 to 2020, 2022 to 2026. Not supported for 2012, 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.