Climate parameters
The Nissan Maxima has 16 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C state NISSAN_AC_ON
- Request
22 11 06 - Service 22
DID 1106 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2013, 2015 to 2023. Not supported for 2014.
Air conditioning compressor speed NISSAN_AC_COMP_RPM
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 1988 to 2023.
Air conditioning on NISSAN_HVAC_AC_ON
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bit 80 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2023.
Air conditioning status NISSAN_AC_STATUS
- Request
22 40 07 - Service 22
DID 4007 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Off or on
In testing for 1988 to 2013, 2015 to 2016, 2018 to 2023. Not supported for 2014, 2017.
Ambient air temperature AATSAE J1979Confirmed
- Request
01 46 - Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017.
Ambient air temperature NISSAN_AAT
- Request
22 40 08 - Service 22
DID 4008 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2013, 2015 to 2016, 2018 to 2023. Not supported for 2014, 2017.
Ambient air temperature NISSAN_AAT_V2
- Request
22 11 5D - Service 22
DID 115D - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.9 − 40.9)- Range
- -36.81 to 192.69 °F
- Unit
- °F
In testing for 1988 to 2013, 2015 to 2016, 2018 to 2023. Not supported for 2014, 2017.
Ambient air temperature, climate module NISSAN_HVAC_AAT
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2023.
Blower on NISSAN_HVAC_FAN_ON
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bit 88 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2023.
Blower voltage NISSAN_HVAC_BLOWER_V
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 89 to 95 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127 V
- Unit
- V
In testing for 1988 to 2023.
Cabin temperature NISSAN_HVAC_CABIN_T
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2023.
Coolant temperature NISSAN_ECT
- Request
22 F4 67 - Service 22
DID F467 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2013, 2015 to 2016, 2018 to 2023. Not supported for 2014, 2017.
ECO mode state NISSAN_ECO_MODE
- Request
22 13 18 - Service 22
DID 1318 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | ECO_OFF | ECO is off |
16 | ECO_ON_1 | ECO is on |
17 | ECO_ON_2 | ECO is on |
In testing for 1988 to 2013, 2015 to 2016, 2018 to 2023. Not supported for 2014, 2017.
Evaporator temperature NISSAN_HVAC_EVAP_T
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2023.
Rear heater state NISSAN_HTR_REAR
- Request
22 11 0F - Service 22
DID 110F - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
162 | HEATER_ON | Heater is on |
In testing for 1988 to 2013, 2015 to 2016, 2018 to 2023. Not supported for 2014, 2017.
Sun load NISSAN_HVAC_SUNLOAD
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2023.