Battery parameters
The MG EHS has 110 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
HV battery coolant temperature EHS_HVBAT_COOLANT_TEMPConfirmed
- Request
22 B0 5C - Service 22
DID B05C - Module
7DF → 7ED - Every
60 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 7 of the reply, 8 bits.
0x6C = 108 → (108 ÷ 2 − 40) = 14 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery current EHS_HVBAT_CURRENTConfirmed
- Request
22 B0 43 - Service 22
DID B043 - Module
7DF → 7ED - Every
250 ms - Testing for 2020 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 − 1000)- Range
- 0 to 250 A
- Unit
- A
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery health EHS_HVBAT_SOHConfirmed
Pelican can show this parameter as the state of health.
- Request
22 B0 61 - Service 22
DID B061 - Module
7DF → 7ED - Every
30 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x2565 = 9573 → (9573 ÷ 100) = 95.73 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery is charging? EHS_HVBAT_CHARGINGConfirmed
Pelican can show this parameter as the charging state.
- Request
22 B0 48 - Service 22
DID B048 - Module
7DF → 7ED - Every
1 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bit 7 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery temperature EHS_HVBAT_TEMPConfirmed
- Request
22 B0 56 - Service 22
DID B056 - Module
7DF → 7ED - Every
60 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 7 of the reply, 8 bits.
0x70 = 112 → (112 ÷ 2 − 40) = 16 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery voltage EHS_HVBAT_VOLTAGEConfirmed
- Request
22 B0 42 - Service 22
DID B042 - Module
7DF → 7ED - Every
250 ms - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x04E1 = 1249 → (1249 ÷ 4) = 312.25 V
- Formula
(val ÷ 4)- Range
- 0 to 500 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Knock sensor voltage EHS_KNOCK_SNS_V
- Request
22 B1 40 - Service 22
DID B140 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 255)- Range
- 0 to 5 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › EVCC
Charging EHS_EVCC_CHARGING
- Request
22 B0 0F - Service 22
DID B00F - Module
7DF → 7EC - Every
4 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Current EHS_EVCC_CURRENT
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5 − 409.6)- Range
- 0 to 250 A
- Unit
- A
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Max current EHS_EVCC_MAX_CURRENT
- Request
22 B0 03 - Service 22
DID B003 - Module
7DF → 7EC - Every
180 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.434782609)- Range
- 0 to 110.869565 A
- Unit
- A
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Voltage EHS_EVCC_VOLTAGE
- Request
22 B0 10 - Service 22
DID B010 - Module
7DF → 7EC - Every
4 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 97)- Range
- 0 to 675.618556 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Internal
HV battery bus voltage EHS_HVBAT_BUS_VOLTAGEConfirmed
- Request
22 B0 41 - Service 22
DID B041 - Module
7DF → 7ED - Every
30 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x027F = 639 → (639 ÷ 4) = 159.75 V
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery internal resistance EHS_HVBAT_RESISTANCEConfirmed
- Request
22 B0 45 - Service 22
DID B045 - Module
7DF → 7ED - Every
60 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x1C9D = 7325 → (7325 ÷ 2) = 3,662.5
- Formula
(val ÷ 2)- Range
- 0 to 32767.5
- Unit
- Number
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery raw charge EHS_HVBAT_RAW_SOCConfirmed
HV battery raw charge
- Request
22 B0 46 - Service 22
DID B046 - Module
7DF → 7ED - Every
30 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x00A5 = 165 → (165 ÷ 10) = 16.5 %
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Battery › Modules › 01
HV battery module 01 max temperature EHS_HVBAT_CMU01_MAXTEMPConfirmed
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
0x80 = 128 → (128 ÷ 2 − 40) = 24 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 01 max voltage EHS_HVBAT_CMU01_MAXVOLTConfirmed
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
0x164C = 5708 → (5708 ÷ 2000 + 1) = 3.854 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 01 min temperature EHS_HVBAT_CMU01_MINTEMPConfirmed
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
0x80 = 128 → (128 ÷ 2 − 40) = 24 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 01 min voltage EHS_HVBAT_CMU01_MINVOLTConfirmed
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x1644 = 5700 → (5700 ÷ 2000 + 1) = 3.85 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Battery › Modules › 02
HV battery module 02 max temperature EHS_HVBAT_CMU02_MAXTEMPConfirmed
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
0x78 = 120 → (120 ÷ 2 − 40) = 20 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 02 max voltage EHS_HVBAT_CMU02_MAXVOLTConfirmed
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
0x1370 = 4976 → (4976 ÷ 2000 + 1) = 3.488 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 02 min temperature EHS_HVBAT_CMU02_MINTEMPConfirmed
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
0x78 = 120 → (120 ÷ 2 − 40) = 20 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 02 min voltage EHS_HVBAT_CMU02_MINVOLTConfirmed
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x135A = 4954 → (4954 ÷ 2000 + 1) = 3.477 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Battery › Modules › 03
HV battery module 03 max temperature EHS_HVBAT_CMU03_MAXTEMPConfirmed
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
0x8A = 138 → (138 ÷ 2 − 40) = 29 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 03 max voltage EHS_HVBAT_CMU03_MAXVOLTConfirmed
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
0x1344 = 4932 → (4932 ÷ 2000 + 1) = 3.466 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 03 min temperature EHS_HVBAT_CMU03_MINTEMPConfirmed
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
0x8A = 138 → (138 ÷ 2 − 40) = 29 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 03 min voltage EHS_HVBAT_CMU03_MINVOLTConfirmed
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x132A = 4906 → (4906 ÷ 2000 + 1) = 3.453 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Battery › Modules › 04
HV battery module 04 max temperature EHS_HVBAT_CMU04_MAXTEMPConfirmed
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
0x78 = 120 → (120 ÷ 2 − 40) = 20 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 04 max voltage EHS_HVBAT_CMU04_MAXVOLTConfirmed
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
0x1358 = 4952 → (4952 ÷ 2000 + 1) = 3.476 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 04 min temperature EHS_HVBAT_CMU04_MINTEMPConfirmed
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
0x78 = 120 → (120 ÷ 2 − 40) = 20 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 04 min voltage EHS_HVBAT_CMU04_MINVOLTConfirmed
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x131A = 4890 → (4890 ÷ 2000 + 1) = 3.445 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Battery › Modules › 05
HV battery module 05 max temperature EHS_HVBAT_CMU05_MAXTEMPConfirmed
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
0x8A = 138 → (138 ÷ 2 − 40) = 29 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 05 max voltage EHS_HVBAT_CMU05_MAXVOLTConfirmed
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
0x133A = 4922 → (4922 ÷ 2000 + 1) = 3.461 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 05 min temperature EHS_HVBAT_CMU05_MINTEMPConfirmed
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
0x8A = 138 → (138 ÷ 2 − 40) = 29 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 05 min voltage EHS_HVBAT_CMU05_MINVOLTConfirmed
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x1328 = 4904 → (4904 ÷ 2000 + 1) = 3.452 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Battery › Modules › 06
HV battery module 06 max temperature EHS_HVBAT_CMU06_MAXTEMPConfirmed
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 40 to 47 of the reply, 8 bits.
0x94 = 148 → (148 ÷ 2 − 40) = 34 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 06 max voltage EHS_HVBAT_CMU06_MAXVOLTConfirmed
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 16 to 31 of the reply, 16 bits.
0x136E = 4974 → (4974 ÷ 2000 + 1) = 3.487 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 06 min temperature EHS_HVBAT_CMU06_MINTEMPConfirmed
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 32 to 39 of the reply, 8 bits.
0x92 = 146 → (146 ÷ 2 − 40) = 33 °C
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
HV battery module 06 min voltage EHS_HVBAT_CMU06_MINVOLTConfirmed
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 MG EHS.
Bits 0 to 15 of the reply, 16 bits.
0x1366 = 4966 → (4966 ÷ 2000 + 1) = 3.483 V
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Battery › Modules › 07
HV battery module 07 max temperature EHS_HVBAT_CMU07_MAXTEMP
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 07 max voltage EHS_HVBAT_CMU07_MAXVOLT
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 07 min temperature EHS_HVBAT_CMU07_MINTEMP
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 07 min voltage EHS_HVBAT_CMU07_MINVOLT
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 08
HV battery module 08 max temperature EHS_HVBAT_CMU08_MAXTEMP
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 08 max voltage EHS_HVBAT_CMU08_MAXVOLT
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 08 min temperature EHS_HVBAT_CMU08_MINTEMP
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 08 min voltage EHS_HVBAT_CMU08_MINVOLT
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 09
HV battery module 09 max temperature EHS_HVBAT_CMU09_MAXTEMP
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 09 max voltage EHS_HVBAT_CMU09_MAXVOLT
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 09 min temperature EHS_HVBAT_CMU09_MINTEMP
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 09 min voltage EHS_HVBAT_CMU09_MINVOLT
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 10
HV battery module 10 max temperature EHS_HVBAT_CMU10_MAXTEMP
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 10 max voltage EHS_HVBAT_CMU10_MAXVOLT
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 10 min temperature EHS_HVBAT_CMU10_MINTEMP
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 10 min voltage EHS_HVBAT_CMU10_MINVOLT
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 11
HV battery module 11 max temperature EHS_HVBAT_CMU11_MAXTEMP
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 11 max voltage EHS_HVBAT_CMU11_MAXVOLT
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 11 min temperature EHS_HVBAT_CMU11_MINTEMP
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 11 min voltage EHS_HVBAT_CMU11_MINVOLT
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 12
HV battery module 12 max temperature EHS_HVBAT_CMU12_MAXTEMP
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 12 max voltage EHS_HVBAT_CMU12_MAXVOLT
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 12 min temperature EHS_HVBAT_CMU12_MINTEMP
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 12 min voltage EHS_HVBAT_CMU12_MINVOLT
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 13
HV battery module 13 max temperature EHS_HVBAT_CMU13_MAXTEMP
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 13 max voltage EHS_HVBAT_CMU13_MAXVOLT
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 13 min temperature EHS_HVBAT_CMU13_MINTEMP
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 13 min voltage EHS_HVBAT_CMU13_MINVOLT
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 14
HV battery module 14 max temperature EHS_HVBAT_CMU14_MAXTEMP
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 14 max voltage EHS_HVBAT_CMU14_MAXVOLT
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 14 min temperature EHS_HVBAT_CMU14_MINTEMP
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 14 min voltage EHS_HVBAT_CMU14_MINVOLT
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 15
HV battery module 15 max temperature EHS_HVBAT_CMU15_MAXTEMP
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 15 max voltage EHS_HVBAT_CMU15_MAXVOLT
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 15 min temperature EHS_HVBAT_CMU15_MINTEMP
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 15 min voltage EHS_HVBAT_CMU15_MINVOLT
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 16
HV battery module 16 max temperature EHS_HVBAT_CMU16_MAXTEMP
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 16 max voltage EHS_HVBAT_CMU16_MAXVOLT
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 16 min temperature EHS_HVBAT_CMU16_MINTEMP
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 16 min voltage EHS_HVBAT_CMU16_MINVOLT
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 17
HV battery module 17 max temperature EHS_HVBAT_CMU17_MAXTEMP
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 17 max voltage EHS_HVBAT_CMU17_MAXVOLT
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 17 min temperature EHS_HVBAT_CMU17_MINTEMP
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 17 min voltage EHS_HVBAT_CMU17_MINVOLT
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 18
HV battery module 18 max temperature EHS_HVBAT_CMU18_MAXTEMP
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 18 max voltage EHS_HVBAT_CMU18_MAXVOLT
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 18 min temperature EHS_HVBAT_CMU18_MINTEMP
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 18 min voltage EHS_HVBAT_CMU18_MINVOLT
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 19
HV battery module 19 max temperature EHS_HVBAT_CMU19_MAXTEMP
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 19 max voltage EHS_HVBAT_CMU19_MAXVOLT
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 19 min temperature EHS_HVBAT_CMU19_MINTEMP
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 19 min voltage EHS_HVBAT_CMU19_MINVOLT
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 20
HV battery module 20 max temperature EHS_HVBAT_CMU20_MAXTEMP
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 20 max voltage EHS_HVBAT_CMU20_MAXVOLT
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 20 min temperature EHS_HVBAT_CMU20_MINTEMP
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 20 min voltage EHS_HVBAT_CMU20_MINVOLT
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 21
HV battery module 21 max temperature EHS_HVBAT_CMU21_MAXTEMP
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 21 max voltage EHS_HVBAT_CMU21_MAXVOLT
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 21 min temperature EHS_HVBAT_CMU21_MINTEMP
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 21 min voltage EHS_HVBAT_CMU21_MINVOLT
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 22
HV battery module 22 max temperature EHS_HVBAT_CMU22_MAXTEMP
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 22 max voltage EHS_HVBAT_CMU22_MAXVOLT
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 22 min temperature EHS_HVBAT_CMU22_MINTEMP
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 22 min voltage EHS_HVBAT_CMU22_MINVOLT
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 23
HV battery module 23 max temperature EHS_HVBAT_CMU23_MAXTEMP
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 23 max voltage EHS_HVBAT_CMU23_MAXVOLT
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 23 min temperature EHS_HVBAT_CMU23_MINTEMP
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 23 min voltage EHS_HVBAT_CMU23_MINVOLT
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
Battery › Modules › 24
HV battery module 24 max temperature EHS_HVBAT_CMU24_MAXTEMP
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 24 max voltage EHS_HVBAT_CMU24_MAXVOLT
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 24 min temperature EHS_HVBAT_CMU24_MINTEMP
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.
HV battery module 24 min voltage EHS_HVBAT_CMU24_MINVOLT
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.