MG EHS

Battery parameters

The MG EHS has 110 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

HV battery health EHS_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Request22 B0 61
  • Service 22DID B061
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x2565 = 9573 → (9573 ÷ 100) = 95.73 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

HV battery coolant temperature EHS_HVBAT_COOLANT_TEMPConfirmed

  • Request22 B0 5C
  • Service 22DID B05C
  • Module7DF → 7ED
  • Every60 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 7 of the reply, 8 bits.

0x6C = 108 → (108 ÷ 2 − 40) = 14 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery current EHS_HVBAT_CURRENTConfirmed

  • Request22 B0 43
  • Service 22DID B043
  • Module7DF → 7ED
  • Every250 ms
  • Testing for 2020 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40 − 1000)
Range
0 to 250 A
Unit
A

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery health EHS_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Request22 B0 61
  • Service 22DID B061
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x2565 = 9573 → (9573 ÷ 100) = 95.73 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery is charging? EHS_HVBAT_CHARGINGConfirmed

Pelican can show this parameter as the charging state.

  • Request22 B0 48
  • Service 22DID B048
  • Module7DF → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bit 7 of the reply.

0b1 = 1 → 1

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery temperature EHS_HVBAT_TEMPConfirmed

  • Request22 B0 56
  • Service 22DID B056
  • Module7DF → 7ED
  • Every60 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 7 of the reply, 8 bits.

0x70 = 112 → (112 ÷ 2 − 40) = 16 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery voltage EHS_HVBAT_VOLTAGEConfirmed

  • Request22 B0 42
  • Service 22DID B042
  • Module7DF → 7ED
  • Every250 ms
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x04E1 = 1249 → (1249 ÷ 4) = 312.25 V

Formula
(val ÷ 4)
Range
0 to 500 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Knock sensor voltage EHS_KNOCK_SNS_V

  • Request22 B1 40
  • Service 22DID B140
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 255)
Range
0 to 5 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › EVCC

Charging EHS_EVCC_CHARGING

  • Request22 B0 0F
  • Service 22DID B00F
  • Module7DF → 7EC
  • Every4 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Current EHS_EVCC_CURRENT

  • Request22 B0 01
  • Service 22DID B001
  • Module7DF → 7EC
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5 − 409.6)
Range
0 to 250 A
Unit
A

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Max current EHS_EVCC_MAX_CURRENT

  • Request22 B0 03
  • Service 22DID B003
  • Module7DF → 7EC
  • Every180 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.434782609)
Range
0 to 110.869565 A
Unit
A

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Voltage EHS_EVCC_VOLTAGE

  • Request22 B0 10
  • Service 22DID B010
  • Module7DF → 7EC
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 97)
Range
0 to 675.618556 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Internal

HV battery bus voltage EHS_HVBAT_BUS_VOLTAGEConfirmed

  • Request22 B0 41
  • Service 22DID B041
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x027F = 639 → (639 ÷ 4) = 159.75 V

Formula
(val ÷ 4)
Range
0 to 1000 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery internal resistance EHS_HVBAT_RESISTANCEConfirmed

  • Request22 B0 45
  • Service 22DID B045
  • Module7DF → 7ED
  • Every60 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x1C9D = 7325 → (7325 ÷ 2) = 3,662.5

Formula
(val ÷ 2)
Range
0 to 32767.5
Unit
Number

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery raw charge EHS_HVBAT_RAW_SOCConfirmed

HV battery raw charge

  • Request22 B0 46
  • Service 22DID B046
  • Module7DF → 7ED
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x00A5 = 165 → (165 ÷ 10) = 16.5 %

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Battery › Modules › 01

HV battery module 01 max temperature EHS_HVBAT_CMU01_MAXTEMPConfirmed

  • Request22 B0 01
  • Service 22DID B001
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 40 to 47 of the reply, 8 bits.

0x80 = 128 → (128 ÷ 2 − 40) = 24 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 01 max voltage EHS_HVBAT_CMU01_MAXVOLTConfirmed

  • Request22 B0 01
  • Service 22DID B001
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 16 to 31 of the reply, 16 bits.

0x164C = 5708 → (5708 ÷ 2000 + 1) = 3.854 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 01 min temperature EHS_HVBAT_CMU01_MINTEMPConfirmed

  • Request22 B0 01
  • Service 22DID B001
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 32 to 39 of the reply, 8 bits.

0x80 = 128 → (128 ÷ 2 − 40) = 24 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 01 min voltage EHS_HVBAT_CMU01_MINVOLTConfirmed

  • Request22 B0 01
  • Service 22DID B001
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x1644 = 5700 → (5700 ÷ 2000 + 1) = 3.85 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Battery › Modules › 02

HV battery module 02 max temperature EHS_HVBAT_CMU02_MAXTEMPConfirmed

  • Request22 B0 09
  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 40 to 47 of the reply, 8 bits.

0x78 = 120 → (120 ÷ 2 − 40) = 20 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 02 max voltage EHS_HVBAT_CMU02_MAXVOLTConfirmed

  • Request22 B0 09
  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 16 to 31 of the reply, 16 bits.

0x1370 = 4976 → (4976 ÷ 2000 + 1) = 3.488 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 02 min temperature EHS_HVBAT_CMU02_MINTEMPConfirmed

  • Request22 B0 09
  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 32 to 39 of the reply, 8 bits.

0x78 = 120 → (120 ÷ 2 − 40) = 20 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 02 min voltage EHS_HVBAT_CMU02_MINVOLTConfirmed

  • Request22 B0 09
  • Service 22DID B009
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x135A = 4954 → (4954 ÷ 2000 + 1) = 3.477 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Battery › Modules › 03

HV battery module 03 max temperature EHS_HVBAT_CMU03_MAXTEMPConfirmed

  • Request22 B0 11
  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 40 to 47 of the reply, 8 bits.

0x8A = 138 → (138 ÷ 2 − 40) = 29 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 03 max voltage EHS_HVBAT_CMU03_MAXVOLTConfirmed

  • Request22 B0 11
  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 16 to 31 of the reply, 16 bits.

0x1344 = 4932 → (4932 ÷ 2000 + 1) = 3.466 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 03 min temperature EHS_HVBAT_CMU03_MINTEMPConfirmed

  • Request22 B0 11
  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 32 to 39 of the reply, 8 bits.

0x8A = 138 → (138 ÷ 2 − 40) = 29 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 03 min voltage EHS_HVBAT_CMU03_MINVOLTConfirmed

  • Request22 B0 11
  • Service 22DID B011
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x132A = 4906 → (4906 ÷ 2000 + 1) = 3.453 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Battery › Modules › 04

HV battery module 04 max temperature EHS_HVBAT_CMU04_MAXTEMPConfirmed

  • Request22 B0 19
  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 40 to 47 of the reply, 8 bits.

0x78 = 120 → (120 ÷ 2 − 40) = 20 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 04 max voltage EHS_HVBAT_CMU04_MAXVOLTConfirmed

  • Request22 B0 19
  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 16 to 31 of the reply, 16 bits.

0x1358 = 4952 → (4952 ÷ 2000 + 1) = 3.476 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 04 min temperature EHS_HVBAT_CMU04_MINTEMPConfirmed

  • Request22 B0 19
  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 32 to 39 of the reply, 8 bits.

0x78 = 120 → (120 ÷ 2 − 40) = 20 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 04 min voltage EHS_HVBAT_CMU04_MINVOLTConfirmed

  • Request22 B0 19
  • Service 22DID B019
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x131A = 4890 → (4890 ÷ 2000 + 1) = 3.445 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Battery › Modules › 05

HV battery module 05 max temperature EHS_HVBAT_CMU05_MAXTEMPConfirmed

  • Request22 B0 21
  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 40 to 47 of the reply, 8 bits.

0x8A = 138 → (138 ÷ 2 − 40) = 29 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 05 max voltage EHS_HVBAT_CMU05_MAXVOLTConfirmed

  • Request22 B0 21
  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 16 to 31 of the reply, 16 bits.

0x133A = 4922 → (4922 ÷ 2000 + 1) = 3.461 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 05 min temperature EHS_HVBAT_CMU05_MINTEMPConfirmed

  • Request22 B0 21
  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 32 to 39 of the reply, 8 bits.

0x8A = 138 → (138 ÷ 2 − 40) = 29 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 05 min voltage EHS_HVBAT_CMU05_MINVOLTConfirmed

  • Request22 B0 21
  • Service 22DID B021
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x1328 = 4904 → (4904 ÷ 2000 + 1) = 3.452 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Battery › Modules › 06

HV battery module 06 max temperature EHS_HVBAT_CMU06_MAXTEMPConfirmed

  • Request22 B0 29
  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 40 to 47 of the reply, 8 bits.

0x94 = 148 → (148 ÷ 2 − 40) = 34 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 06 max voltage EHS_HVBAT_CMU06_MAXVOLTConfirmed

  • Request22 B0 29
  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 16 to 31 of the reply, 16 bits.

0x136E = 4974 → (4974 ÷ 2000 + 1) = 3.487 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 06 min temperature EHS_HVBAT_CMU06_MINTEMPConfirmed

  • Request22 B0 29
  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 32 to 39 of the reply, 8 bits.

0x92 = 146 → (146 ÷ 2 − 40) = 33 °C

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

HV battery module 06 min voltage EHS_HVBAT_CMU06_MINVOLTConfirmed

  • Request22 B0 29
  • Service 22DID B029
  • Module7DF → 7ED
  • Every180 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 MG EHS.

Bits 0 to 15 of the reply, 16 bits.

0x1366 = 4966 → (4966 ÷ 2000 + 1) = 3.483 V

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.

Battery › Modules › 07

HV battery module 07 max temperature EHS_HVBAT_CMU07_MAXTEMP

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 07 max voltage EHS_HVBAT_CMU07_MAXVOLT

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 07 min temperature EHS_HVBAT_CMU07_MINTEMP

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 07 min voltage EHS_HVBAT_CMU07_MINVOLT

  • Request22 B0 A3
  • Service 22DID B0A3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 08

HV battery module 08 max temperature EHS_HVBAT_CMU08_MAXTEMP

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 08 max voltage EHS_HVBAT_CMU08_MAXVOLT

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 08 min temperature EHS_HVBAT_CMU08_MINTEMP

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 08 min voltage EHS_HVBAT_CMU08_MINVOLT

  • Request22 B0 AB
  • Service 22DID B0AB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 09

HV battery module 09 max temperature EHS_HVBAT_CMU09_MAXTEMP

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 09 max voltage EHS_HVBAT_CMU09_MAXVOLT

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 09 min temperature EHS_HVBAT_CMU09_MINTEMP

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 09 min voltage EHS_HVBAT_CMU09_MINVOLT

  • Request22 B0 B3
  • Service 22DID B0B3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 10

HV battery module 10 max temperature EHS_HVBAT_CMU10_MAXTEMP

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 10 max voltage EHS_HVBAT_CMU10_MAXVOLT

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 10 min temperature EHS_HVBAT_CMU10_MINTEMP

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 10 min voltage EHS_HVBAT_CMU10_MINVOLT

  • Request22 B0 BB
  • Service 22DID B0BB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 11

HV battery module 11 max temperature EHS_HVBAT_CMU11_MAXTEMP

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 11 max voltage EHS_HVBAT_CMU11_MAXVOLT

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 11 min temperature EHS_HVBAT_CMU11_MINTEMP

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 11 min voltage EHS_HVBAT_CMU11_MINVOLT

  • Request22 B0 C3
  • Service 22DID B0C3
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 12

HV battery module 12 max temperature EHS_HVBAT_CMU12_MAXTEMP

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 12 max voltage EHS_HVBAT_CMU12_MAXVOLT

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 12 min temperature EHS_HVBAT_CMU12_MINTEMP

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 12 min voltage EHS_HVBAT_CMU12_MINVOLT

  • Request22 B0 CB
  • Service 22DID B0CB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 13

HV battery module 13 max temperature EHS_HVBAT_CMU13_MAXTEMP

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 13 max voltage EHS_HVBAT_CMU13_MAXVOLT

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 13 min temperature EHS_HVBAT_CMU13_MINTEMP

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 13 min voltage EHS_HVBAT_CMU13_MINVOLT

  • Request22 B0 DB
  • Service 22DID B0DB
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 14

HV battery module 14 max temperature EHS_HVBAT_CMU14_MAXTEMP

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 14 max voltage EHS_HVBAT_CMU14_MAXVOLT

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 14 min temperature EHS_HVBAT_CMU14_MINTEMP

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 14 min voltage EHS_HVBAT_CMU14_MINVOLT

  • Request22 B0 DC
  • Service 22DID B0DC
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 15

HV battery module 15 max temperature EHS_HVBAT_CMU15_MAXTEMP

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 15 max voltage EHS_HVBAT_CMU15_MAXVOLT

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 15 min temperature EHS_HVBAT_CMU15_MINTEMP

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 15 min voltage EHS_HVBAT_CMU15_MINVOLT

  • Request22 B0 DD
  • Service 22DID B0DD
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 16

HV battery module 16 max temperature EHS_HVBAT_CMU16_MAXTEMP

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 16 max voltage EHS_HVBAT_CMU16_MAXVOLT

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 16 min temperature EHS_HVBAT_CMU16_MINTEMP

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 16 min voltage EHS_HVBAT_CMU16_MINVOLT

  • Request22 B0 DE
  • Service 22DID B0DE
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 17

HV battery module 17 max temperature EHS_HVBAT_CMU17_MAXTEMP

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 17 max voltage EHS_HVBAT_CMU17_MAXVOLT

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 17 min temperature EHS_HVBAT_CMU17_MINTEMP

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 17 min voltage EHS_HVBAT_CMU17_MINVOLT

  • Request22 B1 0E
  • Service 22DID B10E
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 18

HV battery module 18 max temperature EHS_HVBAT_CMU18_MAXTEMP

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 18 max voltage EHS_HVBAT_CMU18_MAXVOLT

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 18 min temperature EHS_HVBAT_CMU18_MINTEMP

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 18 min voltage EHS_HVBAT_CMU18_MINVOLT

  • Request22 B1 0F
  • Service 22DID B10F
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 19

HV battery module 19 max temperature EHS_HVBAT_CMU19_MAXTEMP

  • Request22 B1 10
  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 19 max voltage EHS_HVBAT_CMU19_MAXVOLT

  • Request22 B1 10
  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 19 min temperature EHS_HVBAT_CMU19_MINTEMP

  • Request22 B1 10
  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 19 min voltage EHS_HVBAT_CMU19_MINVOLT

  • Request22 B1 10
  • Service 22DID B110
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 20

HV battery module 20 max temperature EHS_HVBAT_CMU20_MAXTEMP

  • Request22 B1 11
  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 20 max voltage EHS_HVBAT_CMU20_MAXVOLT

  • Request22 B1 11
  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 20 min temperature EHS_HVBAT_CMU20_MINTEMP

  • Request22 B1 11
  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 20 min voltage EHS_HVBAT_CMU20_MINVOLT

  • Request22 B1 11
  • Service 22DID B111
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 21

HV battery module 21 max temperature EHS_HVBAT_CMU21_MAXTEMP

  • Request22 B1 12
  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 21 max voltage EHS_HVBAT_CMU21_MAXVOLT

  • Request22 B1 12
  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 21 min temperature EHS_HVBAT_CMU21_MINTEMP

  • Request22 B1 12
  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 21 min voltage EHS_HVBAT_CMU21_MINVOLT

  • Request22 B1 12
  • Service 22DID B112
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 22

HV battery module 22 max temperature EHS_HVBAT_CMU22_MAXTEMP

  • Request22 B1 13
  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 22 max voltage EHS_HVBAT_CMU22_MAXVOLT

  • Request22 B1 13
  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 22 min temperature EHS_HVBAT_CMU22_MINTEMP

  • Request22 B1 13
  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 22 min voltage EHS_HVBAT_CMU22_MINVOLT

  • Request22 B1 13
  • Service 22DID B113
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 23

HV battery module 23 max temperature EHS_HVBAT_CMU23_MAXTEMP

  • Request22 B1 14
  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 23 max voltage EHS_HVBAT_CMU23_MAXVOLT

  • Request22 B1 14
  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 23 min temperature EHS_HVBAT_CMU23_MINTEMP

  • Request22 B1 14
  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 23 min voltage EHS_HVBAT_CMU23_MINVOLT

  • Request22 B1 14
  • Service 22DID B114
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

Battery › Modules › 24

HV battery module 24 max temperature EHS_HVBAT_CMU24_MAXTEMP

  • Request22 B1 15
  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 24 max voltage EHS_HVBAT_CMU24_MAXVOLT

  • Request22 B1 15
  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 24 min temperature EHS_HVBAT_CMU24_MINTEMP

  • Request22 B1 15
  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
0 to 87.5 °C
Unit
°C

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.

HV battery module 24 min voltage EHS_HVBAT_CMU24_MINVOLT

  • Request22 B1 15
  • Service 22DID B115
  • Module7DF → 7ED
  • Every180 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2000 + 1)
Range
0 to 10 V
Unit
V

In testing for 2020 to 2023, 2025 to 2026. Not supported for 2024.