Transmission parameters
The Mazda CX-30 has 26 transmission parameters.
● Confirmed◆ In testing○ Supported× Not supported
Axle gear ratio, measured CX30_AXLE_GEAR_RATIO_MEAS
- Request
22 1E 16 - Service 22
DID 1E16 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 10
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Clutch pedal position switch CX30_CPP_SW
- Request
22 A2 11 - Service 22
DID A211 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Converter speed ratio CX30_CONV_SPD_RAT
- Request
22 11 BA - Service 22
DID 11BA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 82)- Range
- 0 to 3996.0365
- Unit
- Number
In testing for 2020, 2022 to 2024, 2026. Not supported for 2021, 2025.
Current gear CX30_GEAR
The automatic transmission gear.
- Request
22 1E 12 - Service 22
DID 1E12 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Gear CX30_GEAR_7E1Confirmed
- Request
22 1E 12 - Service 22
DID 1E12 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Gear ratio, commanded CX30_PCM_CMD_TRANS_GEAR_RATIO
- Request
22 1E 19 - Service 22
DID 1E19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 16 ÷ 65535)- Range
- 0 to 16
- Unit
- Number
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Gear, engaged CX30_GEAR_ENGConfirmed
- Request
22 1E 1F - Service 22
DID 1E1F - Module
7E0 → 7E8 - Every
250 ms - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 6
- Unit
- Number
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
In gear switch CX30_INGEAR_SW
- Request
22 11 01 - Service 22
DID 1101 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Park neutral position switch CX30_PNP_SW
- Request
22 A2 11 - Service 22
DID A211 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Shift gear CX30_GEAR_SHFT
- Request
22 1E 23 - Service 22
DID 1E23 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
10 | MANUAL | Manual |
46 | DRIVE | Drive |
50 | NEUTRAL | Neutral |
60 | REVERSE | Reverse |
70 | PARK | Park |
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Torque converter line pressure CX30_TQ_CONV_LINE_P
- Request
22 11 C0 - Service 22
DID 11C0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 172369 ÷ 5000)- Range
- 0 to 8790.819 kPa
- Unit
- kPa
In testing for 2020, 2022 to 2024, 2026. Not supported for 2021, 2025.
Torque into torque converter, variant 2 CX30_TQ_INTO_TQ_CONV_VAR_2
- Request
22 16 3A - Service 22
DID 163A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.2711635897)- Range
- 0 to 69.1467 N·m
- Unit
- N·m
In testing for 2020, 2022 to 2024, 2026. Not supported for 2021, 2025.
Transmission fluid temperature CX30_TRANS_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 1E 1C - Service 22
DID 1E1C - Module
7E1 → 7E9 - Every
5 s - Testing for 2020, 2024
Example reply from a 2026 Mazda CX-30.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x01F2 = 498 → (498 ÷ 16) = 31.125 °C
- Formula
(val ÷ 16)- Range
- -40 to 300 °C
- Unit
- °C
Confirmed for 2021 to 2023, 2025 to 2026. In testing for 2020, 2024.
Transmission gear CX30_TRANS_GEAR
- Request
22 11 B3 - Service 22
DID 11B3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5
- Unit
- Number
In testing for 2020, 2022 to 2024, 2026. Not supported for 2021, 2025.
Transmission gear CX30_TRANS_GEAR_7E1
- Request
22 11 B3 - Service 22
DID 11B3 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5
- Unit
- Number
In testing for 2020, 2022 to 2024, 2026. Not supported for 2021, 2025.
Transmission gear ratio CX30_TRANS_GEAR_RAT
- Request
22 16 3B - Service 22
DID 163B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 15.7480315)- Range
- 0 to 4015.748
- Unit
- Number
In testing for 2020, 2022 to 2024, 2026. Not supported for 2021, 2025.
Transmission odometer CX30_TRANS_ODOConfirmed
Pelican can show this parameter as the odometer.
- Request
22 DD 01 - Service 22
DID DD01 - Module
7E1 → 7E9 - Every
30 s - Testing for 2020, 2022, 2024, 2026
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
Confirmed for 2021, 2023, 2025. In testing for 2020, 2022, 2024, 2026.
Transmission output shaft speed CX30_TRANS_OUTPUT_SHFT
- Request
22 11 B5 - Service 22
DID 11B5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40)- Range
- 0 to 1638.375 rpm
- Unit
- rpm
In testing for 2020, 2022 to 2024, 2026. Not supported for 2021, 2025.
Transmission pressure, commanded CX30_PCM_CMD_TRANS_MAIN_LINE_P
- Request
22 1E 1A - Service 22
DID 1E1A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534 kPa
- Unit
- kPa
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Transmission temperature CX30_TT
- Request
22 1E 1C - Service 22
DID 1E1C - Module
7E6 → 7EE - Every
5 s - Testing for 2020 to 2022, 2024 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -300 to 300 °C
- Unit
- °C
In testing for 2020, 2024. Supported for 2023. Not supported for 2021 to 2022, 2025 to 2026.
Transmission temperature v5 CX30_TRANS_T_V5
- Request
22 17 B3 - Service 22
DID 17B3 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 42 ÷ 25 − 57)- Range
- -57 to 371.4 °F
- Unit
- °F
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Transmission temperature, pan CX30_ATF_PAN_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 82 - Service 21
PID 82 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Transmission temperature, torque converter CX30_ATF_TQC_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 82 - Service 21
PID 82 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2024. Not supported for 2021 to 2023, 2025 to 2026.
Transmission temperature, variant 1 CX30_TRANS_T_VAR_1
- Request
22 17 B3 - Service 22
DID 17B3 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 42 ÷ 25 − 57)- Range
- -57 to 371.4 °F
- Unit
- °F
In testing for 2020, 2022 to 2024, 2026. Not supported for 2021, 2025.
Transmission temperature, variant 5 CX30_TRANS_T_VAR_5
- Request
22 11 BD - Service 22
DID 11BD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 80 + 32)- Range
- 0 to 7404.6875 °F
- Unit
- °F
In testing for 2020, 2022 to 2024, 2026. Not supported for 2021, 2025.
Transmission temperature, variant 6 CX30_TRANS_T_VAR_6
- Request
22 11 BD - Service 22
DID 11BD - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 80 + 32)- Range
- 0 to 7404.6875 °F
- Unit
- °F
In testing for 2020, 2022 to 2024, 2026. Not supported for 2021, 2025.