Mazda BT50

Door parameters

The Mazda BT50 has 11 door parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Driver door ajar MAZDA_DRIVER_DOOR_OPEN

  • Request22 C1 50
  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Driver door ajar MAZDA_DRIVER_DOOR_OPEN

  • Request22 C1 50
  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2026.

Drivers door rear mirror x-axis MAZDA_DRIVERS_DOOR_REAR_X

  • Request22 A4 A7
  • Service 22DID A4A7
  • Module740
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2006 to 2026.

Drivers door rear mirror y-axis MAZDA_DRIVERS_DOOR_REAR_Y

  • Request22 A4 A8
  • Service 22DID A4A8
  • Module740
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2006 to 2026.

Hood ajar MAZDA_HOOD_OPEN

  • Request22 C1 54
  • Service 22DID C154
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2026.

Lock status MAZDA_CENTRAL_LOCK_STATUS

  • Request22 C2 59
  • Service 22DID C259
  • Module726 → 72E
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNLOCKEDUnlocked
2LOCKEDLocked

In testing for 2006 to 2026.

Passenger door ajar MAZDA_PASSENGER_DOOR_OPEN

  • Request22 C1 50
  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2026.

Passenger door rear mirror x-axis MAZDA_PASSENGER_DOOR_REAR_MIRROR_X

  • Request22 A4 A8
  • Service 22DID A4A8
  • Module741
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2006 to 2026.

Passenger door rear mirror x-axis MAZDA_PASSENGER_DOOR_REAR_X

  • Request22 A4 A7
  • Service 22DID A4A7
  • Module741
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2006 to 2026.

Rear left door ajar MAZDA_RLD_OPEN

  • Request22 C1 50
  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2026.

Rear right door ajar MAZDA_RRD_OPEN

  • Request22 C1 50
  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2026.

Trunk ajar MAZDA_TRUNK_OPEN

  • Request22 C1 50
  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.