Lincoln Nautilus

Drivetrain parameters

The Lincoln Nautilus has 10 drivetrain parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Primary motor coil temperature LINCOLN_PRI_MOTOR_COIL_T

  • Request22 48 1F
  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Primary motor coil temperature LINCOLN_PRI_MOTOR_COIL_T

  • Request22 48 1F
  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 2019 to 2026.

Primary motor inverter temperature LINCOLN_PRI_MOTOR_INV_T

  • Request22 48 24
  • Service 22DID 4824
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 2019 to 2026.

Primary motor inverter voltage LINCOLN_PRI_MOTOR_INV_V

  • Request22 48 1D
  • Service 22DID 481D
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-400 to 400 V
Unit
V

In testing for 2019 to 2026.

Primary motor speed LINCOLN_PRI_MOTOR_RPM

  • Request22 1E 2C
  • Service 22DID 1E2C
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-6000 to 12000 rpm
Unit
rpm

In testing for 2019 to 2026.

Primary motor torque LINCOLN_PRI_MOTOR_TQ

  • Request22 48 1C
  • Service 22DID 481C
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-200 to 200 N·m
Unit
N·m

In testing for 2019 to 2026.

Secondary motor coil temperature LINCOLN_SEC_MOTOR_COIL_T

  • Request22 48 20
  • Service 22DID 4820
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 2019 to 2026.

Secondary motor inverter temperature LINCOLN_SEC_MOTOR_INV_T

  • Request22 48 1E
  • Service 22DID 481E
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 2019 to 2026.

Secondary motor inverter voltage LINCOLN_SEC_MOTOR_INV_V

  • Request22 48 23
  • Service 22DID 4823
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-400 to 400 V
Unit
V

In testing for 2019 to 2026.

Secondary motor speed LINCOLN_SEC_MOTOR_RPM

  • Request22 48 21
  • Service 22DID 4821
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-6000 to 12000 rpm
Unit
rpm

In testing for 2019 to 2026.

Secondary motor torque LINCOLN_SEC_MOTOR_TQ

  • Request22 48 1A
  • Service 22DID 481A
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-200 to 200 N·m
Unit
N·m

In testing for 2019 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.