Drivetrain parameters
The Lincoln Corsair has 10 drivetrain parameters.
● Confirmed◆ In testing○ Supported× Not supported
Primary motor coil temperature LINCOLN_PRI_MOTOR_COIL_T
- Request
22 48 1F - Service 22
DID 481F - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -40 to 300 °C
- Unit
- °C
In testing for 2020 to 2026.
Primary motor inverter temperature LINCOLN_PRI_MOTOR_INV_T
- Request
22 48 24 - Service 22
DID 4824 - Module
7E6 → 7EE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -40 to 300 °C
- Unit
- °C
In testing for 2020 to 2026.
Primary motor inverter voltage LINCOLN_PRI_MOTOR_INV_V
- Request
22 48 1D - Service 22
DID 481D - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -400 to 400 V
- Unit
- V
In testing for 2020 to 2026.
Primary motor speed LINCOLN_PRI_MOTOR_RPM
- Request
22 1E 2C - Service 22
DID 1E2C - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -6000 to 12000 rpm
- Unit
- rpm
In testing for 2020 to 2026.
Primary motor torque LINCOLN_PRI_MOTOR_TQ
- Request
22 48 1C - Service 22
DID 481C - Module
7E6 → 7EE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -200 to 200 N·m
- Unit
- N·m
In testing for 2020 to 2026.
Secondary motor coil temperature LINCOLN_SEC_MOTOR_COIL_T
- Request
22 48 20 - Service 22
DID 4820 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -40 to 300 °C
- Unit
- °C
In testing for 2020 to 2026.
Secondary motor inverter temperature LINCOLN_SEC_MOTOR_INV_T
- Request
22 48 1E - Service 22
DID 481E - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -40 to 300 °C
- Unit
- °C
In testing for 2020 to 2026.
Secondary motor inverter voltage LINCOLN_SEC_MOTOR_INV_V
- Request
22 48 23 - Service 22
DID 4823 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -400 to 400 V
- Unit
- V
In testing for 2020 to 2026.
Secondary motor speed LINCOLN_SEC_MOTOR_RPM
- Request
22 48 21 - Service 22
DID 4821 - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -6000 to 12000 rpm
- Unit
- rpm
In testing for 2020 to 2026.
Secondary motor torque LINCOLN_SEC_MOTOR_TQ
- Request
22 48 1A - Service 22
DID 481A - Module
7E7 → 7EF - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -200 to 200 N·m
- Unit
- N·m
In testing for 2020 to 2026.