Lincoln Aviator

Transmission parameters

The Lincoln Aviator has 27 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

All-wheel drive clutch diagnostic signal LINCOLN_AWD_CLU_DIAGNOSTIC

  • Request22 1E 62
  • Service 22DID 1E62
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2005, 2020 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

All-wheel drive clutch diagnostic signal LINCOLN_AWD_CLU_DIAGNOSTIC

  • Request22 1E 62
  • Service 22DID 1E62
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2005, 2020 to 2026.

All-wheel drive clutch, commanded control signal LINCOLN_AWD_CLU_CMD_CTRL_SIG

  • Request22 1E 63
  • Service 22DID 1E63
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2005, 2020 to 2026.

Axle gear ratio, measured LINCOLN_AXLE_GEAR_RATIO_MEAS

  • Request22 1E 16
  • Service 22DID 1E16
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 10
Unit
Number

In testing for 2003 to 2005, 2020 to 2026.

Converter speed ratio LINCOLN_CONV_SPD_RAT

  • Request22 11 BA
  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 82)
Range
0 to 3996.0365
Unit
Number

In testing for 2003 to 2005, 2020 to 2026.

Gear LINCOLN_GEAR_7E1

  • Request22 1E 1F
  • Service 22DID 1E1F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047
Unit
Number

In testing for 2003 to 2005, 2020 to 2026.

Gear commanded LINCOLN_GEAR_CMD

  • Request22 1E 12
  • Service 22DID 1E12
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNKNOWNUnknown
20L
40D
50N
60R
70P
255FAULTFault

In testing for 2003 to 2005, 2020 to 2026.

Gear ratio, commanded LINCOLN_PCM_CMD_TRANS_GEAR_RATIO

  • Request22 1E 19
  • Service 22DID 1E19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 16 ÷ 65535)
Range
0 to 16
Unit
Number

In testing for 2003 to 2005, 2020 to 2026.

Gear, engaged LINCOLN_GEAR_ENG

  • Request22 1E 1F
  • Service 22DID 1E1F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2003 to 2005, 2020 to 2026.

Measured current of clutch a actuator LINCOLN_MEAS_CURRENT_CLU

  • Request22 1E 9E
  • Service 22DID 1E9E
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 A
Unit
A

In testing for 2003 to 2005, 2020 to 2026.

Torque converter line pressure LINCOLN_TQ_CONV_LINE_P

  • Request22 11 C0
  • Service 22DID 11C0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 172369 ÷ 5000)
Range
0 to 8790.819 kPa
Unit
kPa

In testing for 2003 to 2005, 2020 to 2026.

Torque converter slip LINCOLN_TQ_CONV_SLIP

  • Request22 11 B8
  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1.638538424)
Range
0 to 39996.0104 rpm
Unit
rpm

In testing for 2003 to 2005, 2020 to 2026.

Torque into torque converter LINCOLN_TQ_INTO_TQ_CONV

  • Request22 09 CB
  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1.35581795)
Range
0 to 48336.1353 N·m
Unit
N·m

In testing for 2003 to 2005, 2020 to 2026.

Torque into torque converter LINCOLN_TQ_INTO_TQ_CONV_7E0

  • Request22 16 3A
  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.2711635897)
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2003 to 2005, 2020 to 2026.

Torque into torque converter, variant 2 LINCOLN_TQ_INTO_TQ_CONV_VAR_2

  • Request22 16 3A
  • Service 22DID 163A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.2711635897)
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2003 to 2005, 2020 to 2026.

Transmission fluid fluid quality LINCOLN_TRANS_FLUID_FLUID

  • Request22 18 0F
  • Service 22DID 180F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2005, 2020 to 2026.

Transmission fluid temperature, variant 1 LINCOLN_ATF_T_VAR_1

  • Request22 16 74
  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8)
Range
0 to 8191 °F
Unit
°F

In testing for 2003 to 2005, 2020 to 2026.

Transmission fluid temperature, variant 2 LINCOLN_ATF_T_VAR_2

  • Request22 16 74
  • Service 22DID 1674
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2005, 2020 to 2026.

Transmission fluid temperature, variant 5 LINCOLN_ATF_T_VAR_5

  • Request22 1E 3F
  • Service 22DID 1E3F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2003 to 2005, 2020 to 2026.

Transmission fluid temperature, variant 6 LINCOLN_ATF_T_VAR_6

  • Request22 09 2C
  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2003 to 2005, 2020 to 2026.

Transmission gear LINCOLN_TRANS_GEAR

  • Request22 11 B3
  • Service 22DID 11B3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5
Unit
Number

In testing for 2003 to 2005, 2020 to 2026.

Transmission gear LINCOLN_TRANS_GEAR_7E1

  • Request22 11 B3
  • Service 22DID 11B3
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5
Unit
Number

In testing for 2003 to 2005, 2020 to 2026.

Transmission gear ratio LINCOLN_TRANS_GEAR_RAT

  • Request22 16 3B
  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 15.7480315)
Range
0 to 4015.748
Unit
Number

In testing for 2003 to 2005, 2020 to 2026.

Transmission odometer LINCOLN_TRANS_ODO

  • Request22 DD 01
  • Service 22DID DD01
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 °C
Unit
°C

In testing for 2003 to 2005, 2020 to 2026.

Transmission oil temperature LINCOLN_TOT_V2

  • Request22 1E 1C
  • Service 22DID 1E1C
  • Module7DF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 255 °C
Unit
°C

In testing for 2003 to 2005, 2020 to 2026.

Transmission output shaft speed LINCOLN_TRANS_OUTPUT_SHFT

  • Request22 11 B5
  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40)
Range
0 to 1638.375 rpm
Unit
rpm

In testing for 2003 to 2005, 2020 to 2026.

Transmission pressure, commanded LINCOLN_PCM_CMD_TRANS_MAIN_LINE_P

  • Request22 1E 1A
  • Service 22DID 1E1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 2)
Range
-65536 to 65534 kPa
Unit
kPa

In testing for 2003 to 2005, 2020 to 2026.

Transmission temperature LINCOLN_TT

  • Request22 1E 1C
  • Service 22DID 1E1C
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-300 to 300 °C
Unit
°C

In testing for 2003 to 2005, 2020 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.