INFINITI QX80

Climate parameters

The INFINITI QX80 has 12 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Air conditioning compressor speed QX80_AC_COMP_RPM

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Air conditioning compressor speed QX80_AC_COMP_RPM

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Air conditioning on QX80_HVAC_AC_ON

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 80 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Air conditioning status QX80_AC_STATUS

  • Request22 40 07
  • Service 22DID 4007
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Off or on

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023.

Ambient air temperature QX80_AAT

  • Request22 40 08
  • Service 22DID 4008
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Ambient air temperature, climate module QX80_HVAC_AAT

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Blower on QX80_HVAC_FAN_ON

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Blower voltage QX80_HVAC_BLOWER_V

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 89 to 95 of the reply, 7 bits.

Formula
val
Range
0 to 127 V
Unit
V

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Cabin temperature QX80_HVAC_CABIN_T

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Engine coolant temperature QX80_ECT

Pelican can show this parameter as the engine coolant temperature.

  • Request22 F4 67
  • Service 22DID F467
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Evaporator temperature QX80_HVAC_EVAP_T

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Sun load QX80_HVAC_SUNLOAD

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.