Climate parameters
The INFINITI QX80 has 12 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
Air conditioning compressor speed QX80_AC_COMP_RPM
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.
Air conditioning on QX80_HVAC_AC_ON
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bit 80 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.
Air conditioning status QX80_AC_STATUS
- Request
22 40 07 - Service 22
DID 4007 - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Off or on
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.
Ambient air temperature AATSAE J1979Confirmed
- Request
01 46 - Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023.
Ambient air temperature QX80_AAT
- Request
22 40 08 - Service 22
DID 4008 - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.
Ambient air temperature, climate module QX80_HVAC_AAT
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.
Blower on QX80_HVAC_FAN_ON
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bit 88 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.
Blower voltage QX80_HVAC_BLOWER_V
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 89 to 95 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127 V
- Unit
- V
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.
Cabin temperature QX80_HVAC_CABIN_T
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.
Engine coolant temperature QX80_ECT
Pelican can show this parameter as the engine coolant temperature.
- Request
22 F4 67 - Service 22
DID F467 - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.
Evaporator temperature QX80_HVAC_EVAP_T
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.
Sun load QX80_HVAC_SUNLOAD
- Request
21 10 - Service 21
PID 10 - Module
744 → 764 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2014 to 2022, 2024 to 2026. Not supported for 2023.