INFINITI Q70

Transmission parameters

The INFINITI Q70 has 48 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Acceleration sensor voltage INFINITI_TCM_G_V

  • Request22 12 08
  • Service 22DID 1208
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10000)
Range
-3.27 to 3.27 V
Unit
V

In testing for 2011 to 2019.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Acceleration sensor voltage INFINITI_TCM_G_V

  • Request22 12 08
  • Service 22DID 1208
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10000)
Range
-3.27 to 3.27 V
Unit
V

In testing for 2011 to 2019.

All-wheel drive clutch high temperature signal 1 INFINITI_AWD_CLU_HIGH_T_SIG_1

  • Request22 13 14
  • Service 22DID 1314
  • Module748 → 768
  • Every5 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

All-wheel drive clutch high temperature signal 2 INFINITI_AWD_CLU_HIGH_T_SIG_2

  • Request22 13 15
  • Service 22DID 1315
  • Module748 → 768
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Engage reverse gear INFINITI_ENGAGE_REVERSE_GEAR

  • Request22 20 79
  • Service 22DID 2079
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2019.

Engine torque INFINITI_TCM_ENG_TQ

  • Request22 12 14
  • Service 22DID 1214
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2011 to 2019.

Engine torque, active INFINITI_TCM_ENG_TQ_ACT

  • Request22 12 12
  • Service 22DID 1212
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2011 to 2019.

Engine torque, transmitted INFINITI_TCM_ENG_TQ_TX

  • Request22 12 13
  • Service 22DID 1213
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2011 to 2019.

Estimated vehicle speed INFINITI_TCM_VSS_EST

  • Request22 11 02
  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2011 to 2019.

Fluid temperature sensor voltage INFINITI_TCM_ATF_T_V

  • Request22 12 07
  • Service 22DID 1207
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1023)
Range
0 to 320 V
Unit
V

In testing for 2011 to 2019.

Gearbox ratio INFINITI_GEARBOX_RAT

  • Request22 2C 04
  • Service 22DID 2C04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Input speed, alternate INFINITI_TCM_INPUT_RPM_2

  • Request22 12 0C
  • Service 22DID 120C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2011 to 2019.

Isolation solenoid 1 current INFINITI_TCM_ISO_1_C

  • Request22 12 19
  • Service 22DID 1219
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 1000)
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Isolation solenoid 2 current INFINITI_TCM_ISO_2_C

  • Request22 12 1A
  • Service 22DID 121A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 1000)
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Line pressure INFINITI_TCM_LINE_P

  • Request22 11 0E
  • Service 22DID 110E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 kPa
Unit
kPa

In testing for 2011 to 2019.

Lubrication pressure INFINITI_TCM_LUBE_P

  • Request22 11 0D
  • Service 22DID 110D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 10)
Range
-1280 to 1270 kPa
Unit
kPa

In testing for 2011 to 2019.

Primary pressure sensor voltage INFINITI_TCM_PRI_P_V

  • Request22 12 06
  • Service 22DID 1206
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1023)
Range
0 to 320 V
Unit
V

In testing for 2011 to 2019.

Primary pulley pressure INFINITI_TCM_PRI_P

  • Request22 11 0B
  • Service 22DID 110B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25)
Range
0 to 1638375 kPa
Unit
kPa

In testing for 2011 to 2019.

Primary pulley torque INFINITI_TCM_PRI_TQ

  • Request22 12 15
  • Service 22DID 1215
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2011 to 2019.

Primary solenoid current INFINITI_TCM_PRI_SOL_C

  • Request22 12 1B
  • Service 22DID 121B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 1000)
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Primary solenoid monitor current INFINITI_TCM_PRI_SOL_MON

  • Request22 12 21
  • Service 22DID 1221
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 1000)
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Pulley ratio INFINITI_TCM_PULLEY_RAT

  • Request22 12 10
  • Service 22DID 1210
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.55
Unit
Number

In testing for 2011 to 2019.

Requested engine speed INFINITI_TCM_REQ_RPM

  • Request22 11 14
  • Service 22DID 1114
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2011 to 2019.

Requested torque INFINITI_TCM_REQ_TQ

  • Request22 11 13
  • Service 22DID 1113
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 2 + 100)
Range
-156 to 354 N·m
Unit
N·m

In testing for 2011 to 2019.

Requested torque delta INFINITI_TCM_REQ_TQ_D

  • Request22 11 12
  • Service 22DID 1112
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 2 + 100)
Range
-156 to 354 N·m
Unit
N·m

In testing for 2011 to 2019.

Secondary pressure sensor voltage INFINITI_TCM_SEC_P_V

  • Request22 12 05
  • Service 22DID 1205
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1023)
Range
0 to 320 V
Unit
V

In testing for 2011 to 2019.

Secondary pulley pressure INFINITI_TCM_SEC_P

  • Request22 11 0A
  • Service 22DID 110A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25)
Range
0 to 1638375 kPa
Unit
kPa

In testing for 2011 to 2019.

Secondary solenoid current INFINITI_TCM_SEC_SOL_C

  • Request22 12 1C
  • Service 22DID 121C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 1000)
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Secondary solenoid monitor current INFINITI_TCM_SEC_SOL_MON

  • Request22 12 22
  • Service 22DID 1222
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 1000)
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Select solenoid current INFINITI_TCM_SEL_SOL_C

  • Request22 12 1D
  • Service 22DID 121D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 1000)
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Select solenoid monitor current INFINITI_TCM_SEL_SOL_MON

  • Request22 12 23
  • Service 22DID 1223
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 1000)
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Solenoid 1 monitor current INFINITI_TCM_SOL_MON_1

  • Request22 12 1E
  • Service 22DID 121E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 1000)
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Solenoid 2 monitor current INFINITI_TCM_SOL_MON_2

  • Request22 12 1F
  • Service 22DID 121F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 1000)
Range
0 to 0.255 A
Unit
A

In testing for 2011 to 2019.

Target primary pulley pressure INFINITI_TCM_PRI_P_TGT

  • Request22 11 0F
  • Service 22DID 110F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 kPa
Unit
kPa

In testing for 2011 to 2019.

Target pulley ratio INFINITI_TCM_PULLEY_RAT_TGT

  • Request22 12 18
  • Service 22DID 1218
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10000)
Range
0 to 6.55
Unit
Number

In testing for 2011 to 2019.

Target secondary pulley pressure INFINITI_TCM_SEC_P_TGT

  • Request22 11 11
  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 kPa
Unit
kPa

In testing for 2011 to 2019.

Target select pressure INFINITI_TCM_SEL_P_TGT

  • Request22 11 10
  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 kPa
Unit
kPa

In testing for 2011 to 2019.

Torque converter slip INFINITI_TQ_CONV_SLIP

  • Request21 01
  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2011 to 2019.

Torque ratio INFINITI_TCM_TQ_RAT

  • Request22 12 16
  • Service 22DID 1216
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 577 ÷ 160000)
Range
0 to 236
Unit
Number

In testing for 2011 to 2019.

Transmission ATF deterioration date INFINITI_TRANS_ATF

  • Request21 03
  • Service 21PID 03
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2011 to 2019.

Transmission fluid temperature INFINITI_ATF_T

  • Request22 21 70
  • Service 22DID 2170
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

Transmission fluid temperature INFINITI_TCM_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 11 0C
  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2011 to 2019.

Transmission fluid temperature, variant 1 INFINITI_ATF_T_VAR_1

  • Request21 01
  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 67)
Range
-67 to 392 °F
Unit
°F

In testing for 2011 to 2019.

Transmission fluid temperature, variant 2 INFINITI_ATF_T_VAR_2

  • Request21 01
  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 67)
Range
-67 to 392 °F
Unit
°F

In testing for 2011 to 2019.

Transmission work hours INFINITI_TRANS_WORK_HOURS

  • Request21 10
  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 6)
Range
0 to 10922 h
Unit
h

In testing for 2011 to 2019.

Transmission work hours warm engine INFINITI_TRANS_WORK_HOURS_WARM_ENG

  • Request21 10
  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 6)
Range
0 to 10922 h
Unit
h

In testing for 2011 to 2019.

Transmission-A INFINITI_TRANS

  • Request21 10
  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2011 to 2019.

Transmission-B INFINITI_TRANS_B

  • Request21 10
  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2011 to 2019.

Vehicle speed sensor INFINITI_TCM_VSS_SENS

  • Request22 11 01
  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2011 to 2019.