Honda Odyssey

Fuel parameters

The Honda Odyssey has 4 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Fuel level ODYSSEY_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 70 29
  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every30 s
  • Testing for 2019, 2022, 2026

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 L
Unit
L

Confirmed for 2018, 2020 to 2021, 2023 to 2025. In testing for 2019, 2022, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Fuel level ODYSSEY_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 70 29
  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every30 s
  • Testing for 2019, 2022, 2026

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 L
Unit
L

Confirmed for 2018, 2020 to 2021, 2023 to 2025. In testing for 2019, 2022, 2026.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2011. Supported for 2007, 2010, 2012 to 2015, 2018 to 2025.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2011. Supported for 2007, 2010, 2012 to 2015, 2018 to 2025.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012, 2014 to 2015, 2020. Supported for 2007, 2010, 2013, 2018 to 2019, 2021 to 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.