Fuel parameters
The Honda CR-V has 24 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Request
01 9E - Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2022 to 2023. Supported for 2019.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2022 to 2023. Supported for 2019.
Fuel level CRV_FLVConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 70 29 - Service 22
DID 7029 - Module
DA60 → 60 - Every
30 s - Testing for 1995 to 2022, 2025 to 2026
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 L
- Unit
- L
Confirmed for 2023 to 2024, 2027. In testing for 1995 to 2009, 2011 to 2022, 2025 to 2026. Not supported for 2010.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2007 to 2010, 2014 to 2016, 2018, 2022 to 2023. Supported for 2011 to 2013, 2017, 2019 to 2021, 2024 to 2025.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2007 to 2010, 2014 to 2016, 2018, 2022 to 2023. Supported for 2011 to 2013, 2017, 2019 to 2021, 2024 to 2025.
Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2007 to 2012, 2014 to 2020, 2022 to 2025. Supported for 2013, 2021.
Fuel/air commanded equivalence ratio CRV_FUEL_AIR_RATIOConfirmed
- Request
22 26 11 - Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing for 1995 to 2022, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023 to 2024, 2027. In testing for 1995 to 2009, 2011 to 2019, 2021 to 2022, 2025 to 2026. Not supported for 2010, 2020.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2022 to 2023. Supported for 2019.
Fuel › Internal
Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022 to 2023. Supported for 2017.
Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed
- Request
01 9F - Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022 to 2023. Supported for 2017.