Honda Clarity

Climate parameters

The Honda Clarity has 4 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C pressure HONDA_AC_PConfirmed

  • Request22 26 13
  • Service 22DID 2613
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 1000 kPa
Unit
kPa

Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C pressure HONDA_AC_PConfirmed

  • Request22 26 13
  • Service 22DID 2613
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 1000 kPa
Unit
kPa

Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018. Supported for 2019, 2021.

Outside air temperature HONDA_AATConfirmed

  • Request22 70 28
  • Service 22DID 7028
  • ModuleDA60 → 60
  • Every5 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018 to 2019. In testing for 2008 to 2014, 2016 to 2017, 2020 to 2021. Not supported for 2022.

Outside air temperature HONDA_AAT_FIRSTGENConfirmed

  • Request22 70 28
  • Service 22DID 7028
  • ModuleDA60 → 60
  • Every5 s
  • Testing

Bits 132 to 143 of the reply, 12 bits. The value is signed.

Formula
val
Range
-40 to 2047 °C
Unit
°C

Confirmed for 2018 to 2019. In testing for 2008 to 2014, 2016 to 2017, 2020 to 2021. Not supported for 2022.