Electrical parameters
The Honda Accord Hybrid has 6 electrical parameters.
● Confirmed◆ In testing○ Supported× Not supported
Brake fluid pressure HONDA_BRK_FLD_PConfirmed
- Request
22 42 01 - Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 5
- Unit
- Raw value
Confirmed for 2018, 2020 to 2021, 2025. In testing for 2005 to 2007, 2014, 2017, 2019, 2022 to 2024, 2026. Not supported for 2015.
Brake pedal stroke HONDA_BRK_PED_STKConfirmed
- Request
22 42 01 - Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 50 mm
- Unit
- mm
Confirmed for 2018, 2020 to 2021, 2025. In testing for 2005 to 2007, 2014, 2017, 2019, 2022 to 2024, 2026. Not supported for 2015.
Brake pressure HONDA_BRK_PConfirmed
- Request
22 40 05 - Service 22
DID 4005 - Module
DA28 → 28 - Every
250 ms - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val − 25)- Range
- 0 to 120 bar
- Unit
- bar
Confirmed for 2018, 2020 to 2021, 2025. In testing for 2005 to 2007, 2014, 2017, 2019, 2022 to 2024, 2026. Not supported for 2015.
Brake switch HONDA_BRK_SWConfirmed
- Request
22 40 04 - Service 22
DID 4004 - Module
DA28 → 28 - Every
250 ms - Testing
Bit 127 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018, 2020 to 2021, 2025. In testing for 2005 to 2007, 2014, 2017, 2019, 2022 to 2024, 2026. Not supported for 2015.
Master cylinder stroke HONDA_MSTR_CYL_STKConfirmed
- Request
22 42 01 - Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing
Bits 232 to 247 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 mm
- Unit
- mm
Confirmed for 2018, 2020 to 2021, 2025. In testing for 2005 to 2007, 2014, 2017, 2019, 2022 to 2024, 2026. Not supported for 2015.
Slave cylinder stroke HONDA_SLV_CYL_STKConfirmed
- Request
22 42 01 - Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 mm
- Unit
- mm
Confirmed for 2018, 2020 to 2021, 2025. In testing for 2005 to 2007, 2014, 2017, 2019, 2022 to 2024, 2026. Not supported for 2015.