Ford Maverick

Climate parameters

The Ford Maverick has 11 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor, state MAVERICK_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s

Example reply from a 2026 Ford Maverick.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2022 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor current MAVERICK_AC_COMP_AConfirmed

  • Request22 99 AB
  • Service 22DID 99AB
  • Module7C7
  • Every5 s

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 A
Unit
A

Confirmed for 2022 to 2026.

A/C compressor pressure MAVERICK_AC_P

  • Request22 03 93
  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 245251 ÷ 845473)
Range
0 to 1000 psi
Unit
psi

Not supported for 2022 to 2026.

A/C compressor pressure sensor voltage MAVERICK_AC_P_SENS_VConfirmed

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2022 to 2026.

A/C compressor, state MAVERICK_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s

Example reply from a 2026 Ford Maverick.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2022 to 2026.

A/C refrigerant pressure MAVERICK_PCM_A_C_REFRIG_PConfirmed

  • Request22 06 04
  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Confirmed for 2022 to 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. Supported for 2022, 2026.

Ambient temperature sensor voltage MAVERICK_AAT_VConfirmed

  • Request22 03 BA
  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s

Example reply from a 2026 Ford Maverick.

Bits 0 to 15 of the reply, 16 bits.

0x020D = 525 → (525 × 5 ÷ 1023) = 2.565982 V

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

Confirmed for 2022 to 2026.

Ambient temperature, alternate MAVERICK_AAT_ALTConfirmed

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s

Example reply from a 2026 Ford Maverick.

Bits 0 to 7 of the reply, 8 bits.

0x86 = 134 → (134 ÷ 2 − 40) = 27 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2022 to 2026.

Coolant heater operation mode MAVERICK_COOLANT_HTR_OP_MODEConfirmed

  • Request22 48 DF
  • Service 22DID 48DF
  • Module7E6 → 7EE
  • Every10 s

Example reply from a 2026 Ford Maverick.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → OFF

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ONOn
2DEGRADEDDegraded
3SHUTDOWNShutdown
4SHORTShort
5NO_RESPONSENo response
6UNKNOWNUnknown
7STOPStop

Confirmed for 2022 to 2026.

Exterior temperature MAVERICK_AAT

  • Request22 DD 05
  • Service 22DID DD05
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 2022 to 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Supported for 2025 to 2026. Not supported for 2022 to 2024.

Interior temperature MAVERICK_IAT

  • Request22 DD 04
  • Service 22DID DD04
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Not supported for 2022 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.