Battery parameters
The Ford Fusion Hybrid has 46 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery age FUSIONH_12V_AGEConfirmed
- Request
22 40 27 - Service 22
DID 4027 - Module
726 → 72E - Every
3600 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x087A = 2170 → (2170 × 24) = 52,080 h
- Formula
(val × 24)- Range
- 0 to 1572840 h
- Unit
- h
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
12V battery state of charge FUSIONH_12V_SOCConfirmed
- Request
22 40 28 - Service 22
DID 4028 - Module
726 → 72E - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x2E = 46 → 46 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
12V battery temperature FUSIONH_12V_TConfirmed
- Request
22 40 29 - Service 22
DID 4029 - Module
726 → 72E - Every
5 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x31 = 49 → (49 − 40) = 9 °C
- Formula
(val − 40)- Range
- -40 to 100 °C
- Unit
- °C
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
12V battery voltage FUSIONH_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 2A - Service 22
DID 402A - Module
726 → 72E - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x74 = 116 → (116 ÷ 20 + 6) = 11.8 V
- Formula
(val ÷ 20 + 6)- Range
- 0 to 18.75 V
- Unit
- V
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
Average battery module voltage FUSIONH_AVG_BAT_MODULE_VConfirmed
- Request
22 48 41 - Service 22
DID 4841 - Module
7E4 → 7EC - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0D3B = 3387 → (3387 ÷ 1000) = 3.387 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
Battery capacity too low for start/stop FUSIONH_BAT_CAP_TOO_LOWConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bit 5 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Battery current too high for start/stop FUSIONH_BAT_CURRENT_TOO_HIGHConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bit 2 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Battery quiescent current, low range FUSIONH_BAT_QUIESCENTConfirmed
- Request
22 40 25 - Service 22
DID 4025 - Module
726 → 72E - Every
1 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0850 = 2128 → (2128 ÷ 2 − 1000) = 64 mA
- Formula
(val ÷ 2 − 1000)- Range
- -1000 to 31767.5 mA
- Unit
- mA
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Battery refresh cycle in progress for start/stop FUSIONH_BAT_REFRESH_CYCLEConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bit 14 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Battery state detection status FUSIONH_BAT_ST_DETECTIONConfirmed
- Request
22 42 0A - Service 22
DID 420A - Module
726 → 72E - Every
1 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x03 = 3 → 3
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Battery state of charge too low for start/stop FUSIONH_BAT_ST_CHG_TOO_LOWConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bit 4 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Battery temperature too low for auto stop FUSIONH_BAT_T_TOO_LOW_AUTOConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bit 13 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Battery voltage FUSIONH_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 11 72 - Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.9375 V
- Unit
- V
In testing for 2010 to 2016, 2018. Not supported for 2017, 2019 to 2020.
Battery voltage too low for auto restart FUSIONH_BAT_V_TOO_LOW_AUTOConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bit 12 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Battery voltage too low for cold cranking capability FUSIONH_BAT_V_TOO_LOW_COLDConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bit 6 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Battery voltage too low for start/stop FUSIONH_BAT_V_TOO_LOW_STARTConfirmed
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bit 3 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Charging state FUSIONH_CHRG_STATE
Pelican can show this parameter as the charging state.
- Request
22 48 4F - Service 22
DID 484F - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_READY | Not ready |
1 | READY | Ready |
2 | FAULT | Fault |
3 | WAIT | Wait Check |
4 | PRE_COND | Pre-condition |
5 | CHARGING | Charging |
6 | DONE | Done |
7 | EXT | External Charger |
8 | INIT | Initializing |
In testing for 2010 to 2012, 2014 to 2016, 2018. Not supported for 2013, 2017, 2019 to 2020.
Commanded generator voltage FUSIONH_CMD_GEN_VConfirmed
- Request
22 03 04 - Service 22
DID 0304 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x7360 = 29536 → (29536 × 0.000488) = 14.413568 V
- Formula
(val × 0.000488)- Range
- 0 to 16 V
- Unit
- V
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Contactor voltage negative FUSIONH_CONTACTOR_V_NEGConfirmed
- Request
22 48 06 - Service 22
DID 4806 - Module
7E4 → 7EC - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0019 = 25 → (25 ÷ 50) = 0.5 V
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 V
- Unit
- V
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
Contactor voltage positive FUSIONH_CONTACTOR_V_POSConfirmed
- Request
22 48 05 - Service 22
DID 4805 - Module
7E4 → 7EC - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0019 = 25 → (25 ÷ 50) = 0.5 V
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 V
- Unit
- V
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2013, 2017, 2019 to 2020.
DC-DC converter FUSIONH_DCDC_ENABLEDConfirmed
- Request
22 48 3D - Service 22
DID 483D - Module
746 → 74E - Every
10 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
High voltage battery intake air temperature FUSIONH_HVBAT_IAT
- Request
22 00 0F - Service 22
DID 000F - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 39.8)- Range
- -39.8 to 419 °F
- Unit
- °F
In testing for 2010 to 2016, 2018. Not supported for 2017, 2019 to 2020.
HV battery age FUSIONH_HVBAT_AGEConfirmed
- Request
22 48 10 - Service 22
DID 4810 - Module
7E4 → 7EC - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x3491 = 13457 → (13457 × 720 ÷ 200) = 48,445.2 h
- Formula
(val × 720 ÷ 200)- Range
- 0 to 235926 h
- Unit
- h
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
HV battery charge FUSIONH_HVBAT_SOCConfirmed
High resolution state of charge.
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
7E4 → 7EC - Every
1 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x41E1 = 16865 → (16865 ÷ 500) = 33.73 %
- Formula
(val ÷ 500)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
HV battery charge, displayed FUSIONH_HVBAT_SOC_DISPConfirmed
The state of charge displayed on the vehicle's dashboard.
Pelican can show this parameter as the state of charge.
- Request
22 48 45 - Service 22
DID 4845 - Module
7E4 → 7EC - Every
1 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x14 = 20 → (20 ÷ 2) = 10 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
HV battery coolant inlet temperature FUSIONH_HVBAT_COOLANT_INLET_TConfirmed
- Request
22 48 46 - Service 22
DID 4846 - Module
7E4 → 7EC - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x3C = 60 → (60 − 50) = 10 °C
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
HV battery energy FUSIONH_HVBAT_KWH
- Request
22 48 48 - Service 22
DID 4848 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131.07 kWh
- Unit
- kWh
In testing for 2010 to 2012, 2014 to 2016, 2018. Not supported for 2013, 2017, 2019 to 2020.
HV battery state of health FUSIONH_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 49 0C - Service 22
DID 490C - Module
7E4 → 7EC - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2012, 2014 to 2016, 2018. Not supported for 2013, 2017, 2019 to 2020.
HV battery temperature FUSIONH_HVBAT_TConfirmed
- Request
22 48 00 - Service 22
DID 4800 - Module
7E4 → 7EC - Every
10 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x3C = 60 → (60 − 50) = 10 °C
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
HV battery voltage FUSIONH_HVBAT_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 48 0D - Service 22
DID 480D - Module
7E4 → 7EC - Every
1 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x63DE = 25566 → (25566 ÷ 100) = 255.66 V
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
HV negative leakage voltage FUSIONH_HV_NEG_LEAK_VConfirmed
- Request
22 48 04 - Service 22
DID 4804 - Module
7E4 → 7EC - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 1000) = 0 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
HV positive leakage voltage FUSIONH_HV_POS_LEAK_VConfirmed
- Request
22 48 03 - Service 22
DID 4803 - Module
7E4 → 7EC - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 1000) = 0 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
Low voltage converter input current FUSIONH_DCDC_HV_AConfirmed
- Request
22 48 3A - Service 22
DID 483A - Module
746 → 74E - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 25 A
- Unit
- A
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
Low voltage converter output current FUSIONH_DCDC_LV_AConfirmed
- Request
22 48 36 - Service 22
DID 4836 - Module
746 → 74E - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0 A
- Formula
val- Range
- 0 to 255 A
- Unit
- A
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
Maximum discharge power limit FUSIONH_MAX_DISCH_PWR_LIMConfirmed
- Request
22 48 15 - Service 22
DID 4815 - Module
7E4 → 7EC - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x1D = 29 → (29 × 25 ÷ 100) = 7.25 kW
- Formula
(val × 25 ÷ 100)- Range
- 0 to 63.75 kW
- Unit
- kW
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
Minimum battery module voltage FUSIONH_BATT_MIN_BATT_VConfirmed
- Request
22 48 40 - Service 22
DID 4840 - Module
7E4 → 7EC - Every
5 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0D25 = 3365 → (3365 ÷ 1000) = 3.365 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
Normalized cumulative charge when ignition is on FUSIONH_NORM_CUM_CHG_IGN_ONConfirmed
- Request
22 40 1E - Service 22
DID 401E - Module
726 → 72E - Every
1 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x040F = 1039 → (1039 ÷ 10) = 103.9
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Normalized cumulative discharge from battery with engine off FUSIONH_NORM_CUM_DCHG_BAT_OFFConfirmed
- Request
22 40 26 - Service 22
DID 4026 - Module
726 → 72E - Every
1 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0260 = 608 → (608 ÷ 10) = 60.8
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Normalized cumulative discharge from battery with engine on FUSIONH_NORM_CUM_DCHG_BAT_ONConfirmed
- Request
22 40 21 - Service 22
DID 4021 - Module
726 → 72E - Every
1 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0012 = 18 → (18 ÷ 10) = 1.8
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
State of charge spread across battery modules FUSIONH_BATT_SOCConfirmed
- Request
22 48 3E - Service 22
DID 483E - Module
7E4 → 7EC - Every
1 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x032E = 814 → (814 ÷ 1000) = 0.814 %
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 %
- Unit
- %
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Traction battery voltage, alternate FUSIONH_TRACTION_BAT_V_ALT
- Request
22 49 0B - Service 22
DID 490B - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 25 ÷ 8192)- Range
- 0 to 199 V
- Unit
- V
In testing for 2010 to 2016, 2018. Not supported for 2017, 2019 to 2020.
Vehicle battery b current FUSIONH_VEH_BAT_B_CURRENTConfirmed
- Request
22 42 3C - Service 22
DID 423C - Module
726 → 72E - Every
1 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0010 = 16 → (16 ÷ 32) = 0.5 A
- Formula
(val ÷ 32)- Range
- -1024 to 1023.96 A
- Unit
- A
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Vehicle battery b voltage FUSIONH_VEH_BAT_B_VConfirmed
- Request
22 41 E8 - Service 22
DID 41E8 - Module
726 → 72E - Every
1 s - Testing for 2010 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x7C = 124 → (124 ÷ 20 + 6) = 12.2 V
- Formula
(val ÷ 20 + 6)- Range
- 6 to 18.75 V
- Unit
- V
Confirmed for 2017, 2019 to 2020. In testing for 2010 to 2016, 2018.
Vehicle battery current FUSIONH_VEH_BAT_CURRENTConfirmed
- Request
22 40 2B - Service 22
DID 402B - Module
726 → 72E - Every
1 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x64 = 100 → (100 − 127) = -27 A
- Formula
(val − 127)- Range
- -127 to 128 A
- Unit
- A
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.
Voltage spread across battery modules FUSIONH_BAT_V_VARIATION_BATConfirmed
- Request
22 48 3F - Service 22
DID 483F - Module
7E4 → 7EC - Every
1 s - Testing for 2010 to 2012, 2014 to 2016, 2018
Example reply from a 2020 Ford Fusion Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x0003 = 3 → (3 ÷ 1000) = 0.003 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
Confirmed for 2013, 2017, 2019 to 2020. In testing for 2010 to 2012, 2014 to 2016, 2018.