Ford E-Series Wagon

Battery parameters

The Ford E-Series Wagon has 116 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery age FORD_12V_AGE

  • Request22 40 27
  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 24)
Range
0 to 1572840 h
Unit
h

In testing for 1988 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery age FORD_12V_AGE

  • Request22 40 27
  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 24)
Range
0 to 1572840 h
Unit
h

In testing for 1988 to 2026.

12V battery current FORD_VEH_BAT_CURRENT

  • Request22 40 2B
  • Service 22DID 402B
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 127)
Range
-127 to 128 A
Unit
A

In testing for 1988 to 2026.

12V battery state of charge FORD_12V_SOC

  • Request22 40 28
  • Service 22DID 4028
  • Module726 → 72E
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1988 to 2026.

12V battery voltage FORD_VEH_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 40 2A
  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 20 + 6)
Range
0 to 18.75 V
Unit
V

In testing for 1988 to 2026.

Aux 12V battery control mode FORD_AUX_12V_BAT_CTRL

  • Request22 40 D1
  • Service 22DID 40D1
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2026.

Average battery module voltage FORD_AVG_BAT_MODULE_V

  • Request22 48 41
  • Service 22DID 4841
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 V
Unit
V

In testing for 1988 to 2026.

Battery age FORD_BATT_AGE

  • Request22 40 27
  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1825
Unit
Number

In testing for 1988 to 2026.

Battery capacity FORD_BAT_CAP

  • Request22 48 5C
  • Service 22DID 485C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 Ah
Unit
Ah

In testing for 1988 to 2026.

Battery capacity too low for start/stop FORD_BAT_CAP_TOO_LOW

  • Request22 41 A9
  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Battery charge FORD_BATT_SOC

  • Request22 40 28
  • Service 22DID 4028
  • Module726 → 72E
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2026.

Battery current too high for start/stop FORD_BAT_CURRENT_TOO_HIGH

  • Request22 41 A9
  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Battery current, predicted FORD_BAT_CURRENT

  • Request22 42 09
  • Service 22DID 4209
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 4)
Range
0 to 4194303.75 A
Unit
A

In testing for 1988 to 2026.

Battery discharge power limit FORD_BAT_DCHG_POWER_LIM

  • Request22 48 52
  • Service 22DID 4852
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kW
Unit
kW

In testing for 1988 to 2026.

Battery pack lifetime charge out, throughput FORD_BAT_PACK_LIFETIME

  • Request22 48 5D
  • Service 22DID 485D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 Ah
Unit
Ah

In testing for 1988 to 2026.

Battery percentage, state of charge FORD_BAT_PERCENTAGE_ST

  • Request22 40 28
  • Service 22DID 4028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1988 to 2026.

Battery quiescent current, low range FORD_BAT_QUIESCENT

  • Request22 40 25
  • Service 22DID 4025
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 1000)
Range
-1000 to 31767.5 mA
Unit
mA

In testing for 1988 to 2026.

Battery refresh cycle in progress for start/stop FORD_BAT_REFRESH_CYCLE

  • Request22 41 A9
  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Battery state detection status FORD_BAT_ST_DETECTION

  • Request22 42 0A
  • Service 22DID 420A
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2026.

Battery state of charge too low for start/stop FORD_BAT_ST_CHG_TOO_LOW

  • Request22 41 A9
  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Battery temperature FORD_BATT_TEMP

  • Request22 40 29
  • Service 22DID 4029
  • Module726 → 72E
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 100 °C
Unit
°C

In testing for 1988 to 2026.

Battery temperature too low for auto stop FORD_BAT_T_TOO_LOW_AUTO

  • Request22 41 A9
  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Battery voltage FORD_BAT_V

  • Request22 11 72
  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.9375 V
Unit
V

In testing for 1988 to 2026.

Battery voltage too low for auto restart FORD_BAT_V_TOO_LOW_AUTO

  • Request22 41 A9
  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Battery voltage too low for cold cranking capability FORD_BAT_V_TOO_LOW_COLD

  • Request22 41 A9
  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Battery voltage too low for start/stop FORD_BAT_V_TOO_LOW_START

  • Request22 41 A9
  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

Charge air cooler temperature FORD_CHG_AIR_COOLER_T

  • Request22 05 08
  • Service 22DID 0508
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 8)
Range
0 to 524280
Unit
Raw value

In testing for 1988 to 2026.

Charge air temperature FORD_CHG_AIR_T

  • Request22 05 1C
  • Service 22DID 051C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2026.

Charger digital mode FORD_EVSE_DIGITAL_MODE

  • Request22 48 B7
  • Service 22DID 48B7
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1DC_E_MINUSDC E-
2DC_MINUS_PDC -P
3DC_EPDC EP
4AC_E_MINUSAC E-
5AC_MINUS_PAC -P
6AC_EPAC EP
7RESETReset
8OFFOff
9ESTABLISHEstablish
10FAULTFault

In testing for 1988 to 2026.

Charger type FORD_EVSE_TYPE

  • Request22 48 51
  • Service 22DID 4851
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1LEVEL_1Level 1
2LEVEL_2Level 2
3DC
4BASICBasic
5HIGH_LEVELHigh Level
6BASIC_ACBasic AC
7HIGH_LEVEL_ACHigh Level AC
8HIGH_LEVEL_DCHigh Level DC
10NO_COMMNo communication
11FAULTFault
12HANDSHAKE_ENDHandshake end

In testing for 1988 to 2026.

Charging state FORD_CHRG_STATE

Pelican can show this parameter as the charging state.

  • Request22 48 4F
  • Service 22DID 484F
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_READYNot ready
1READYReady
2FAULTFault
3WAITWait Check
4PRE_CONDPre-condition
5CHARGINGCharging
6DONEDone
7EXTExternal Charger
8INITInitializing

In testing for 1988 to 2026.

Commanded generator voltage FORD_CMD_GEN_V

  • Request22 03 04
  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000488)
Range
0 to 16 V
Unit
V

In testing for 1988 to 2026.

Contactor voltage negative FORD_CONTACTOR_V_NEG

  • Request22 48 06
  • Service 22DID 4806
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 300 V
Unit
V

In testing for 1988 to 2026.

Contactor voltage negative FORD_CONTACTOR_V_NEGATIVE

  • Request22 48 06
  • Service 22DID 4806
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.34 V
Unit
V

In testing for 1988 to 2026.

Contactor voltage positive FORD_CONTACTOR_V_POS

  • Request22 48 05
  • Service 22DID 4805
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 300 V
Unit
V

In testing for 1988 to 2026.

Contactor voltage positive FORD_CONTACTOR_V_POSITIVE

  • Request22 48 05
  • Service 22DID 4805
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.34 V
Unit
V

In testing for 1988 to 2026.

DC-DC converter FORD_DCDC_ENABLED

  • Request22 48 3D
  • Service 22DID 483D
  • Module746 → 74E
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2026.

High voltage AC charger coupler temperature FORD_HIGH_V_AC_CHARGER_T

  • Request22 48 88
  • Service 22DID 4888
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 40)
Range
-40 to 419 °F
Unit
°F

In testing for 1988 to 2026.

High voltage AC charger coupler temperature FORD_HIGH_V_AC_CHARGER_T_V2

  • Request22 D1 17
  • Service 22DID D117
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 40)
Range
-40 to 419 °F
Unit
°F

In testing for 1988 to 2026.

High voltage battery intake air temperature FORD_HVBAT_IAT

  • Request22 00 0F
  • Service 22DID 000F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 39.8)
Range
-39.8 to 419 °F
Unit
°F

In testing for 1988 to 2026.

High voltage charger current, requested FORD_HIGH_V_CHARGER

  • Request22 48 42
  • Service 22DID 4842
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 1988 to 2026.

High voltage charger input power available, raw count FORD_HIGH_V_CHARGER_INPUT

  • Request22 48 4E
  • Service 22DID 484E
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 2026.

High voltage charger output current measured FORD_HIGH_V_CHARGER_OUTPUT

  • Request22 48 50
  • Service 22DID 4850
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 1988 to 2026.

High voltage charger output reduction temperature FORD_HIGH_V_CHARGER_T

  • Request22 48 A5
  • Service 22DID 48A5
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1988 to 2026.

High voltage charger output voltage, raw count FORD_HIGH_V_CHARGER_V

  • Request22 48 4A
  • Service 22DID 484A
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 2026.

High voltage charger pilot voltage FORD_HIGH_V_CHARGER_PILOT_V

  • Request22 48 B6
  • Service 22DID 48B6
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1988 to 2026.

High voltage charger pilot voltage, raw count FORD_HIGH_V_CHARGER_PILOT_V_RAW

  • Request22 48 BC
  • Service 22DID 48BC
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 2026.

High voltage charger status FORD_HIGH_V_CHARGER_STAT

  • Request22 48 4D
  • Service 22DID 484D
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2026.

High voltage charger status FORD_HIGH_V_CHARGER_STAT_7E2

  • Request22 48 4F
  • Service 22DID 484F
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2026.

High voltage charger voltage, requested FORD_HIGH_V_CHARGER_V_REQ

  • Request22 48 44
  • Service 22DID 4844
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 1988 to 2026.

High voltage charger, maximum power FORD_HIGH_V_CHARGER_MAX

  • Request22 48 C4
  • Service 22DID 48C4
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kW
Unit
kW

In testing for 1988 to 2026.

High voltage DC charger coupler temperature FORD_HIGH_V_DC_CHARGER_T

  • Request22 D0 0C
  • Service 22DID D00C
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 40)
Range
-40 to 419 °F
Unit
°F

In testing for 1988 to 2026.

High voltage DC charger coupler temperature 1 FORD_HIGH_V_DC_CHARGER_T_1

  • Request22 48 97
  • Service 22DID 4897
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 40)
Range
-40 to 419 °F
Unit
°F

In testing for 1988 to 2026.

High voltage DC charger coupler temperature 3 FORD_HIGH_V_DC_CHARGER_T_3

  • Request22 48 A4
  • Service 22DID 48A4
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 40)
Range
-40 to 419 °F
Unit
°F

In testing for 1988 to 2026.

High voltage DC charger status FORD_HIGH_V_DC_CHARGER

  • Request22 48 9E
  • Service 22DID 489E
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2026.

High-voltage battery current FORD_HVB_CURRENT

  • Request22 48 F9
  • Service 22DID 48F9
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 A
Unit
A

In testing for 1988 to 2026.

HV AC charger coupler temperature FORD_AC_CHG_COUPLER_T

  • Request22 48 88
  • Service 22DID 4888
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2026.

HV AC charger input current FORD_AC_CHG_IN_A

  • Request22 48 5F
  • Service 22DID 485F
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 A
Unit
A

In testing for 1988 to 2026.

HV AC charger input frequency FORD_AC_CHG_IN_FREQ

  • Request22 48 60
  • Service 22DID 4860
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
30 to 90 Hz
Unit
Hz

In testing for 1988 to 2026.

HV AC charger input voltage FORD_AC_CHG_IN_V

  • Request22 48 5E
  • Service 22DID 485E
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 V
Unit
V

In testing for 1988 to 2026.

HV battery age FORD_HVBAT_AGE

  • Request22 48 10
  • Service 22DID 4810
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 720 ÷ 200)
Range
0 to 235926 h
Unit
h

In testing for 1988 to 2026.

HV battery average module voltage FORD_HVBAT_AVG_MOD_V

  • Request22 48 41
  • Service 22DID 4841
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 50 V
Unit
V

In testing for 1988 to 2026.

HV battery charge FORD_HVBAT_SOC

High resolution state of charge.

Pelican can show this parameter as the state of charge.

  • Request22 48 01
  • Service 22DID 4801
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 500)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2026.

HV battery charge (displayed) FORD_HVBAT_SOC_DISP

The state of charge displayed on the vehicle's dashboard.

Pelican can show this parameter as the state of charge.

  • Request22 48 45
  • Service 22DID 4845
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2026.

HV battery charge current requested FORD_HVBAT_CCR

  • Request22 48 42
  • Service 22DID 4842
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 600 A
Unit
A

In testing for 1988 to 2026.

HV battery charge power limit FORD_HVBAT_CHG_PWR_LIM

  • Request22 48 FB
  • Service 22DID 48FB
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 300 kW
Unit
kW

In testing for 1988 to 2026.

HV battery charge voltage requested FORD_HVBAT_CVR

  • Request22 48 44
  • Service 22DID 4844
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 500 V
Unit
V

In testing for 1988 to 2026.

HV battery charging status FORD_HVBAT_CHG_STATUS

  • Request22 48 4D
  • Service 22DID 484D
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_READYNot ready
1WAITWait
2READYReady
3CHARGINGCharging
4DONEDone
5FAULTFault

In testing for 1988 to 2026.

HV battery coolant inlet temperature FORD_HVBAT_COOLANT_INLET_T

  • Request22 48 46
  • Service 22DID 4846
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1988 to 2026.

HV battery current FORD_HVBAT_A

Pelican can show this parameter as the traction battery current.

  • Request22 48 F9
  • Service 22DID 48F9
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-600 to 600 A
Unit
A

In testing for 1988 to 2026.

HV battery current high range FORD_HVBAT_CHR_A

  • Request22 48 09
  • Service 22DID 4809
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 A
Unit
A

In testing for 1988 to 2026.

HV battery current, alternate FORD_HVBAT_A_ALT

  • Request22 48 0B
  • Service 22DID 480B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-300 to 300 A
Unit
A

In testing for 1988 to 2026.

HV battery energy FORD_HVBAT_KWH

  • Request22 48 48
  • Service 22DID 4848
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 500)
Range
0 to 131.07 kWh
Unit
kWh

In testing for 1988 to 2026.

HV battery maximum charge current FORD_HVBAT_MAX_CHG_A

  • Request22 48 BC
  • Service 22DID 48BC
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 15 A
Unit
A

In testing for 1988 to 2026.

HV battery minimum module voltage FORD_HVBAT_MIN_MOD_V

  • Request22 48 40
  • Service 22DID 4840
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1988 to 2026.

HV battery modules voltage FORD_HVBAT_MOD_V

  • Request22 48 3F
  • Service 22DID 483F
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1988 to 2026.

HV battery state of health FORD_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Request22 49 0C
  • Service 22DID 490C
  • Module7E4 → 7EC
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2026.

HV battery temperature FORD_HVBAT_T

  • Request22 48 00
  • Service 22DID 4800
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1988 to 2026.

HV battery temperature range FORD_T_RANGE

  • Request22 48 08
  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every15 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1988 to 2026.

HV battery temperature range, average FORD_T_RANGE_AVG

  • Request22 48 08
  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every15 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1988 to 2026.

HV battery temperature range, maximum FORD_T_RANGE_MAX

  • Request22 48 08
  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1988 to 2026.

HV battery temperature range, minimum FORD_T_RANGE_MIN

  • Request22 48 08
  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1988 to 2026.

HV battery thermal operation mode FORD_HVBAT_THERMAL_OP_MODE

  • Request22 48 E0
  • Service 22DID 48E0
  • Module7E6 → 7EE
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1EQUALIZEEqualize
2COOLANT_FLOWCoolant flow
3COOLANT_FANCoolant fan
4COOLANT_MODERATECoolant moderate
5COOLANT_MAXCoolant maximum
15HEATHeat

In testing for 1988 to 2026.

HV battery voltage FORD_HVBAT_V

  • Request22 48 0D
  • Service 22DID 480D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 1988 to 2026.

HV battery voltage, raw count FORD_HVB_V_RAW_CNT

  • Request22 48 0D
  • Service 22DID 480D
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 2026.

HV charger input power available FORD_CHG_PWR_AVAIL

  • Request22 48 4E
  • Service 22DID 484E
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kW
Unit
kW

In testing for 1988 to 2026.

HV charger maximum power FORD_CHG_MAX_PWR

  • Request22 48 C4
  • Service 22DID 48C4
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 500 kW
Unit
kW

In testing for 1988 to 2026.

HV charger output current measured FORD_CHG_OUT_A

  • Request22 48 50
  • Service 22DID 4850
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 600 A
Unit
A

In testing for 1988 to 2026.

HV charger output reduction temperature FORD_CHG_OUT_REDUCT_T

  • Request22 48 A5
  • Service 22DID 48A5
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1988 to 2026.

HV charger output voltage FORD_CHG_OUT_V

  • Request22 48 4A
  • Service 22DID 484A
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 600 V
Unit
V

In testing for 1988 to 2026.

HV charger pilot duty cycle FORD_CHG_PILOT_DUTY

  • Request22 48 61
  • Service 22DID 4861
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2026.

HV charger pilot voltage FORD_CHG_PILOT_V

  • Request22 48 B6
  • Service 22DID 48B6
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 15 V
Unit
V

In testing for 1988 to 2026.

HV charger proximity status FORD_CHG_PROX_STATUS

  • Request22 48 62
  • Service 22DID 4862
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ON_S3On S3
2ONOn
310A10 A
413A13 A
516A16 A
620A20 A
7FAULTFault
832A32 A
963A63 A
16DC
17OPENOpen
18SHORTShort
19SHORT_PWRShort to power
20OUT_OF_RANGEOut of range
21OPEN_CIRCUITOpen circuit

In testing for 1988 to 2026.

HV charger proximity voltage FORD_CHG_PROX_V

  • Request22 48 A0
  • Service 22DID 48A0
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 1988 to 2026.

HV DC charger coupler temperature 1 FORD_DC_CHG_COUPLER_T1

  • Request22 48 97
  • Service 22DID 4897
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2026.

HV DC charger coupler temperature 3 FORD_DC_CHG_COUPLER_T3

  • Request22 48 A4
  • Service 22DID 48A4
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2026.

HV DC charger maximum current FORD_HVDC_CHG_MAX_C

  • Request22 48 99
  • Service 22DID 4899
  • Module6F5 → 6FD
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 A
Unit
A

In testing for 1988 to 2026.

HV DC charger maximum voltage FORD_HVDC_CHG_MAX_V

  • Request22 48 9D
  • Service 22DID 489D
  • Module6F5 → 6FD
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

In testing for 1988 to 2026.

HV DC charger status FORD_DC_CHG_STATUS

  • Request22 48 9E
  • Service 22DID 489E
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_READYNot ready
1INITInitialize
2READYReady
3WAIT_CHECKWait check
4PRE_CONDITIONPre-condition
5CHARGINGCharging
6DONEDone
8WAITWait
9NOT_CAPABLENot capable
10FAULTFault
11CHARGER_CHECKCharger check

In testing for 1988 to 2026.

HV negative leakage voltage FORD_HV_NEG_LEAK_V

  • Request22 48 04
  • Service 22DID 4804
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1988 to 2026.

HV positive leakage voltage FORD_HV_POS_LEAK_V

  • Request22 48 03
  • Service 22DID 4803
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 1988 to 2026.

Hybrid battery pack remaining charge FORD_HYBRID_BAT_PACK

  • Request22 F4 5B
  • Service 22DID F45B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2026.

Injection control pressure sensor voltage FORD_ICP_V

  • Request22 16 AD
  • Service 22DID 16AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2026.

Low voltage converter input current FORD_DCDC_HV_A

  • Request22 48 3A
  • Service 22DID 483A
  • Module746 → 74E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25 A
Unit
A

In testing for 1988 to 2026.

Low voltage converter output current FORD_DCDC_LV_A

  • Request22 48 36
  • Service 22DID 4836
  • Module746 → 74E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 1988 to 2026.

Maximum discharge power limit FORD_MAX_DISCH_PWR_LIM

  • Request22 48 15
  • Service 22DID 4815
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25 ÷ 100)
Range
0 to 63.75 kW
Unit
kW

In testing for 1988 to 2026.

Minimum battery module voltage FORD_BATT_MIN_BATT_V

  • Request22 48 40
  • Service 22DID 4840
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 V
Unit
V

In testing for 1988 to 2026.

Normalized cumulative charge when ignition is on FORD_NORM_CUM_CHG_IGN_ON

  • Request22 40 1E
  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Number

In testing for 1988 to 2026.

Normalized cumulative discharge from battery with engine off FORD_NORM_CUM_DCHG_BAT_OFF

  • Request22 40 26
  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Number

In testing for 1988 to 2026.

Normalized cumulative discharge from battery with engine on FORD_NORM_CUM_DCHG_BAT_ON

  • Request22 40 21
  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Number

In testing for 1988 to 2026.

PF differential pressure feedback EGR sensor voltage FORD_PF_DIFF_P_FEEDBACK_V

  • Request22 03 E3
  • Service 22DID 03E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 977 ÷ 1000000)
Range
-32.01 to 32.01 V
Unit
V

In testing for 1988 to 2026.

Second battery current FORD_VEH_BAT_B_CURRENT

  • Request22 42 3C
  • Service 22DID 423C
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 32)
Range
-1024 to 1023.96 A
Unit
A

In testing for 1988 to 2026.

Second battery voltage FORD_VEH_BAT_B_V

  • Request22 41 E8
  • Service 22DID 41E8
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 20 + 6)
Range
6 to 18.75 V
Unit
V

In testing for 1988 to 2026.

State of charge spread across battery modules FORD_HVB_SOC_VARIATION

  • Request22 48 3E
  • Service 22DID 483E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 %
Unit
%

In testing for 1988 to 2026.

Target/desired state of charge FORD_TARGET_SOC

  • Request22 05 A1
  • Service 22DID 05A1
  • Module7E4 → 7EC
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1988 to 2026.

Traction battery voltage, alternate FORD_TRACTION_BAT_V_ALT

  • Request22 49 0B
  • Service 22DID 490B
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25 ÷ 8192)
Range
0 to 199 V
Unit
V

In testing for 1988 to 2026.

Voltage spread across battery modules FORD_BAT_V_VARIATION_BAT

  • Request22 48 3F
  • Service 22DID 483F
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 V
Unit
V

In testing for 1988 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.