Battery parameters
The Dodge Journey has 455 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery voltage DODGE_AUX_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 A0 42 - Service 22
DID A042 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Accelerator pedal signal 1 voltage DODGE_ACCEL_PEDAL_SIG_1_V
- Request
22 D4 05 - Service 22
DID D405 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5000.000126)- Range
- -6.55 to 6.55 V
- Unit
- V
In testing for 2009 to 2020.
Accelerator pedal signal 2 voltage DODGE_ACCEL_PEDAL_SIG_2_V
- Request
22 D4 06 - Service 22
DID D406 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5000.000126)- Range
- -6.55 to 6.55 V
- Unit
- V
In testing for 2009 to 2020.
Air heater voltage DODGE_AIRHEATER_V
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2009 to 2020.
Approximate position of turbocharger actuator DODGE_APPROXIMATE_POS
- Request
22 D4 EC - Service 22
DID D4EC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 %
- Unit
- %
In testing for 2009 to 2020.
Average cell voltage value DODGE_AVG_CELL_V
- Request
22 D4 3D - Service 22
DID D43D - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery average temperature DODGE_BAT_AVG_T
- Request
22 D8 77 - Service 22
DID D877 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery cell 01 state of charge DODGE_BAT_CELL_01_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 001 voltage DODGE_BAT_CELL_001_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 01 voltage DODGE_BAT_CELL_01_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 02 state of charge DODGE_BAT_CELL_02_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 002 voltage DODGE_BAT_CELL_002_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 02 voltage DODGE_BAT_CELL_02_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 03 state of charge DODGE_BAT_CELL_03_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 003 voltage DODGE_BAT_CELL_003_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 03 voltage DODGE_BAT_CELL_03_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 04 state of charge DODGE_BAT_CELL_04_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 004 voltage DODGE_BAT_CELL_004_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 04 voltage DODGE_BAT_CELL_04_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 05 state of charge DODGE_BAT_CELL_05_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 005 voltage DODGE_BAT_CELL_005_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 05 voltage DODGE_BAT_CELL_05_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 06 state of charge DODGE_BAT_CELL_06_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 006 voltage DODGE_BAT_CELL_006_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 06 voltage DODGE_BAT_CELL_06_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 07 state of charge DODGE_BAT_CELL_07_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 007 voltage DODGE_BAT_CELL_007_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 07 voltage DODGE_BAT_CELL_07_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 08 state of charge DODGE_BAT_CELL_08_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 008 voltage DODGE_BAT_CELL_008_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 08 voltage DODGE_BAT_CELL_08_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 09 state of charge DODGE_BAT_CELL_09_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 009 voltage DODGE_BAT_CELL_009_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 09 voltage DODGE_BAT_CELL_09_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 10 state of charge DODGE_BAT_CELL_10_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 010 voltage DODGE_BAT_CELL_010_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 10 voltage DODGE_BAT_CELL_10_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 11 state of charge DODGE_BAT_CELL_11_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 011 voltage DODGE_BAT_CELL_011_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 11 voltage DODGE_BAT_CELL_11_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 12 state of charge DODGE_BAT_CELL_12_ST_CHG
- Request
22 B0 04 - Service 22
DID B004 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 012 voltage DODGE_BAT_CELL_012_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 12 voltage DODGE_BAT_CELL_12_V
- Request
22 A1 00 - Service 22
DID A100 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 13 state of charge DODGE_BAT_CELL_13_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 013 voltage DODGE_BAT_CELL_013_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 13 voltage DODGE_BAT_CELL_13_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 14 state of charge DODGE_BAT_CELL_14_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 014 voltage DODGE_BAT_CELL_014_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 14 voltage DODGE_BAT_CELL_14_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 15 state of charge DODGE_BAT_CELL_15_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 015 voltage DODGE_BAT_CELL_015_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 15 voltage DODGE_BAT_CELL_15_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 16 state of charge DODGE_BAT_CELL_16_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 016 voltage DODGE_BAT_CELL_016_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 16 voltage DODGE_BAT_CELL_16_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 17 state of charge DODGE_BAT_CELL_17_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 017 voltage DODGE_BAT_CELL_017_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 17 voltage DODGE_BAT_CELL_17_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 18 state of charge DODGE_BAT_CELL_18_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 018 voltage DODGE_BAT_CELL_018_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 18 voltage DODGE_BAT_CELL_18_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 19 state of charge DODGE_BAT_CELL_19_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 019 voltage DODGE_BAT_CELL_019_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 19 voltage DODGE_BAT_CELL_19_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 20 state of charge DODGE_BAT_CELL_20_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 020 voltage DODGE_BAT_CELL_020_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 20 voltage DODGE_BAT_CELL_20_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 21 state of charge DODGE_BAT_CELL_21_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 021 voltage DODGE_BAT_CELL_021_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 21 voltage DODGE_BAT_CELL_21_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 22 state of charge DODGE_BAT_CELL_22_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 022 voltage DODGE_BAT_CELL_022_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 22 voltage DODGE_BAT_CELL_22_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 23 state of charge DODGE_BAT_CELL_23_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 023 voltage DODGE_BAT_CELL_023_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 23 voltage DODGE_BAT_CELL_23_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 24 state of charge DODGE_BAT_CELL_24_ST_CHG
- Request
22 B0 05 - Service 22
DID B005 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 024 voltage DODGE_BAT_CELL_024_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 24 voltage DODGE_BAT_CELL_24_V
- Request
22 A1 01 - Service 22
DID A101 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 25 state of charge DODGE_BAT_CELL_25_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 025 voltage DODGE_BAT_CELL_025_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 25 voltage DODGE_BAT_CELL_25_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 26 state of charge DODGE_BAT_CELL_26_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 026 voltage DODGE_BAT_CELL_026_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 26 voltage DODGE_BAT_CELL_26_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 27 state of charge DODGE_BAT_CELL_27_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 027 voltage DODGE_BAT_CELL_027_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 27 voltage DODGE_BAT_CELL_27_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 28 state of charge DODGE_BAT_CELL_28_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 028 voltage DODGE_BAT_CELL_028_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 28 voltage DODGE_BAT_CELL_28_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 29 state of charge DODGE_BAT_CELL_29_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 029 voltage DODGE_BAT_CELL_029_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 29 voltage DODGE_BAT_CELL_29_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 30 state of charge DODGE_BAT_CELL_30_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 030 voltage DODGE_BAT_CELL_030_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 30 voltage DODGE_BAT_CELL_30_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 31 state of charge DODGE_BAT_CELL_31_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 031 voltage DODGE_BAT_CELL_031_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 31 voltage DODGE_BAT_CELL_31_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 32 state of charge DODGE_BAT_CELL_32_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 032 voltage DODGE_BAT_CELL_032_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 32 voltage DODGE_BAT_CELL_32_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 33 state of charge DODGE_BAT_CELL_33_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 033 voltage DODGE_BAT_CELL_033_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 33 voltage DODGE_BAT_CELL_33_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 34 state of charge DODGE_BAT_CELL_34_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 034 voltage DODGE_BAT_CELL_034_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 34 voltage DODGE_BAT_CELL_34_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 35 state of charge DODGE_BAT_CELL_35_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 035 voltage DODGE_BAT_CELL_035_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 35 voltage DODGE_BAT_CELL_35_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 36 state of charge DODGE_BAT_CELL_36_ST_CHG
- Request
22 B0 06 - Service 22
DID B006 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 036 voltage DODGE_BAT_CELL_036_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 36 voltage DODGE_BAT_CELL_36_V
- Request
22 A1 02 - Service 22
DID A102 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 37 state of charge DODGE_BAT_CELL_37_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 037 voltage DODGE_BAT_CELL_037_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 37 voltage DODGE_BAT_CELL_37_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 38 state of charge DODGE_BAT_CELL_38_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 038 voltage DODGE_BAT_CELL_038_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 38 voltage DODGE_BAT_CELL_38_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 39 state of charge DODGE_BAT_CELL_39_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 039 voltage DODGE_BAT_CELL_039_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 39 voltage DODGE_BAT_CELL_39_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 40 state of charge DODGE_BAT_CELL_40_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 040 voltage DODGE_BAT_CELL_040_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 40 voltage DODGE_BAT_CELL_40_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 41 state of charge DODGE_BAT_CELL_41_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 041 voltage DODGE_BAT_CELL_041_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 41 voltage DODGE_BAT_CELL_41_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 42 state of charge DODGE_BAT_CELL_42_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 042 voltage DODGE_BAT_CELL_042_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 42 voltage DODGE_BAT_CELL_42_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 43 state of charge DODGE_BAT_CELL_43_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 043 voltage DODGE_BAT_CELL_043_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 43 voltage DODGE_BAT_CELL_43_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 44 state of charge DODGE_BAT_CELL_44_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 044 voltage DODGE_BAT_CELL_044_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 44 voltage DODGE_BAT_CELL_44_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 45 state of charge DODGE_BAT_CELL_45_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 045 voltage DODGE_BAT_CELL_045_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 45 voltage DODGE_BAT_CELL_45_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 46 state of charge DODGE_BAT_CELL_46_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 046 voltage DODGE_BAT_CELL_046_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 46 voltage DODGE_BAT_CELL_46_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 47 state of charge DODGE_BAT_CELL_47_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 047 voltage DODGE_BAT_CELL_047_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 47 voltage DODGE_BAT_CELL_47_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 48 state of charge DODGE_BAT_CELL_48_ST_CHG
- Request
22 B0 07 - Service 22
DID B007 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 048 voltage DODGE_BAT_CELL_048_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 48 voltage DODGE_BAT_CELL_48_V
- Request
22 A1 03 - Service 22
DID A103 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 49 state of charge DODGE_BAT_CELL_49_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 049 voltage DODGE_BAT_CELL_049_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 49 voltage DODGE_BAT_CELL_49_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 50 state of charge DODGE_BAT_CELL_50_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 050 voltage DODGE_BAT_CELL_050_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 50 voltage DODGE_BAT_CELL_50_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 51 state of charge DODGE_BAT_CELL_51_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 051 voltage DODGE_BAT_CELL_051_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 51 voltage DODGE_BAT_CELL_51_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 52 state of charge DODGE_BAT_CELL_52_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 052 voltage DODGE_BAT_CELL_052_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 52 voltage DODGE_BAT_CELL_52_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 53 state of charge DODGE_BAT_CELL_53_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 053 voltage DODGE_BAT_CELL_053_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 53 voltage DODGE_BAT_CELL_53_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 54 state of charge DODGE_BAT_CELL_54_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 054 voltage DODGE_BAT_CELL_054_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 54 voltage DODGE_BAT_CELL_54_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 55 state of charge DODGE_BAT_CELL_55_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 055 voltage DODGE_BAT_CELL_055_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 55 voltage DODGE_BAT_CELL_55_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 56 state of charge DODGE_BAT_CELL_56_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 056 voltage DODGE_BAT_CELL_056_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 56 voltage DODGE_BAT_CELL_56_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 57 state of charge DODGE_BAT_CELL_57_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 057 voltage DODGE_BAT_CELL_057_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 57 voltage DODGE_BAT_CELL_57_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 58 state of charge DODGE_BAT_CELL_58_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 058 voltage DODGE_BAT_CELL_058_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 58 voltage DODGE_BAT_CELL_58_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 59 state of charge DODGE_BAT_CELL_59_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 059 voltage DODGE_BAT_CELL_059_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 59 voltage DODGE_BAT_CELL_59_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 60 state of charge DODGE_BAT_CELL_60_ST_CHG
- Request
22 B0 08 - Service 22
DID B008 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 060 voltage DODGE_BAT_CELL_060_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 60 voltage DODGE_BAT_CELL_60_V
- Request
22 A1 04 - Service 22
DID A104 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 61 state of charge DODGE_BAT_CELL_61_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 061 voltage DODGE_BAT_CELL_061_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 61 voltage DODGE_BAT_CELL_61_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 62 state of charge DODGE_BAT_CELL_62_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 062 voltage DODGE_BAT_CELL_062_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 62 voltage DODGE_BAT_CELL_62_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 63 state of charge DODGE_BAT_CELL_63_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 063 voltage DODGE_BAT_CELL_063_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 63 voltage DODGE_BAT_CELL_63_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 64 state of charge DODGE_BAT_CELL_64_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 064 voltage DODGE_BAT_CELL_064_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 64 voltage DODGE_BAT_CELL_64_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 65 state of charge DODGE_BAT_CELL_65_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 065 voltage DODGE_BAT_CELL_065_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 65 voltage DODGE_BAT_CELL_65_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 66 state of charge DODGE_BAT_CELL_66_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 066 voltage DODGE_BAT_CELL_066_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 66 voltage DODGE_BAT_CELL_66_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 67 state of charge DODGE_BAT_CELL_67_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 067 voltage DODGE_BAT_CELL_067_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 67 voltage DODGE_BAT_CELL_67_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 68 state of charge DODGE_BAT_CELL_68_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 068 voltage DODGE_BAT_CELL_068_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 68 voltage DODGE_BAT_CELL_68_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 69 state of charge DODGE_BAT_CELL_69_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 069 voltage DODGE_BAT_CELL_069_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 69 voltage DODGE_BAT_CELL_69_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 70 state of charge DODGE_BAT_CELL_70_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 070 voltage DODGE_BAT_CELL_070_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 70 voltage DODGE_BAT_CELL_70_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 71 state of charge DODGE_BAT_CELL_71_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 071 voltage DODGE_BAT_CELL_071_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 71 voltage DODGE_BAT_CELL_71_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 72 state of charge DODGE_BAT_CELL_72_ST_CHG
- Request
22 B0 09 - Service 22
DID B009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 072 voltage DODGE_BAT_CELL_072_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 72 voltage DODGE_BAT_CELL_72_V
- Request
22 A1 05 - Service 22
DID A105 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 73 state of charge DODGE_BAT_CELL_73_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 073 voltage DODGE_BAT_CELL_073_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 73 voltage DODGE_BAT_CELL_73_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 74 state of charge DODGE_BAT_CELL_74_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 074 voltage DODGE_BAT_CELL_074_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 74 voltage DODGE_BAT_CELL_74_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 75 state of charge DODGE_BAT_CELL_75_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 075 voltage DODGE_BAT_CELL_075_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 75 voltage DODGE_BAT_CELL_75_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 76 state of charge DODGE_BAT_CELL_76_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 076 voltage DODGE_BAT_CELL_076_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 76 voltage DODGE_BAT_CELL_76_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 77 state of charge DODGE_BAT_CELL_77_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 077 voltage DODGE_BAT_CELL_077_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 77 voltage DODGE_BAT_CELL_77_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 78 state of charge DODGE_BAT_CELL_78_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 078 voltage DODGE_BAT_CELL_078_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 78 voltage DODGE_BAT_CELL_78_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 79 state of charge DODGE_BAT_CELL_79_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 079 voltage DODGE_BAT_CELL_079_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 79 voltage DODGE_BAT_CELL_79_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 80 state of charge DODGE_BAT_CELL_80_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 080 voltage DODGE_BAT_CELL_080_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 80 voltage DODGE_BAT_CELL_80_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 81 state of charge DODGE_BAT_CELL_81_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 081 voltage DODGE_BAT_CELL_081_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 81 voltage DODGE_BAT_CELL_81_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 82 state of charge DODGE_BAT_CELL_82_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 082 voltage DODGE_BAT_CELL_082_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 82 voltage DODGE_BAT_CELL_82_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 83 state of charge DODGE_BAT_CELL_83_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 083 voltage DODGE_BAT_CELL_083_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 83 voltage DODGE_BAT_CELL_83_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 84 state of charge DODGE_BAT_CELL_84_ST_CHG
- Request
22 B0 0A - Service 22
DID B00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 084 voltage DODGE_BAT_CELL_084_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 84 voltage DODGE_BAT_CELL_84_V
- Request
22 A1 06 - Service 22
DID A106 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 85 state of charge DODGE_BAT_CELL_85_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 085 voltage DODGE_BAT_CELL_085_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 85 voltage DODGE_BAT_CELL_85_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 86 state of charge DODGE_BAT_CELL_86_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 086 voltage DODGE_BAT_CELL_086_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 86 voltage DODGE_BAT_CELL_86_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 87 state of charge DODGE_BAT_CELL_87_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 087 voltage DODGE_BAT_CELL_087_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 87 voltage DODGE_BAT_CELL_87_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 88 state of charge DODGE_BAT_CELL_88_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 088 voltage DODGE_BAT_CELL_088_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 88 voltage DODGE_BAT_CELL_88_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 89 state of charge DODGE_BAT_CELL_89_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 089 voltage DODGE_BAT_CELL_089_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 89 voltage DODGE_BAT_CELL_89_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 90 state of charge DODGE_BAT_CELL_90_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 090 voltage DODGE_BAT_CELL_090_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 90 voltage DODGE_BAT_CELL_90_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 91 state of charge DODGE_BAT_CELL_91_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 091 voltage DODGE_BAT_CELL_091_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 91 voltage DODGE_BAT_CELL_91_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 92 state of charge DODGE_BAT_CELL_92_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 092 voltage DODGE_BAT_CELL_092_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 92 voltage DODGE_BAT_CELL_92_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 93 state of charge DODGE_BAT_CELL_93_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 093 voltage DODGE_BAT_CELL_093_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 93 voltage DODGE_BAT_CELL_93_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 94 state of charge DODGE_BAT_CELL_94_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 094 voltage DODGE_BAT_CELL_094_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 94 voltage DODGE_BAT_CELL_94_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 95 state of charge DODGE_BAT_CELL_95_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 095 voltage DODGE_BAT_CELL_095_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 95 voltage DODGE_BAT_CELL_95_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 96 state of charge DODGE_BAT_CELL_96_ST_CHG
- Request
22 B0 0B - Service 22
DID B00B - Module
DA44 → 44 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 096 voltage DODGE_BAT_CELL_096_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 96 voltage DODGE_BAT_CELL_96_V
- Request
22 A1 07 - Service 22
DID A107 - Module
DA44 → 44 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Battery cell 97 state of charge DODGE_BAT_CELL_97_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 097 voltage DODGE_BAT_CELL_097_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,536 to 1,551 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 98 state of charge DODGE_BAT_CELL_98_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 098 voltage DODGE_BAT_CELL_098_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,552 to 1,567 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 99 state of charge DODGE_BAT_CELL_99_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 099 voltage DODGE_BAT_CELL_099_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,568 to 1,583 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 100 state of charge DODGE_BAT_CELL_100_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 100 voltage DODGE_BAT_CELL_100_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,584 to 1,599 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 101 state of charge DODGE_BAT_CELL_101_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 101 voltage DODGE_BAT_CELL_101_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,600 to 1,615 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 102 state of charge DODGE_BAT_CELL_102_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 102 voltage DODGE_BAT_CELL_102_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,616 to 1,631 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 103 state of charge DODGE_BAT_CELL_103_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 103 voltage DODGE_BAT_CELL_103_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,632 to 1,647 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 104 state of charge DODGE_BAT_CELL_104_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 104 voltage DODGE_BAT_CELL_104_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,648 to 1,663 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 105 state of charge DODGE_BAT_CELL_105_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 105 voltage DODGE_BAT_CELL_105_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,664 to 1,679 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 106 state of charge DODGE_BAT_CELL_106_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 106 voltage DODGE_BAT_CELL_106_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,680 to 1,695 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 107 state of charge DODGE_BAT_CELL_107_ST_CHG
- Request
22 B0 0C - Service 22
DID B00C - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Battery cell 107 voltage DODGE_BAT_CELL_107_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,696 to 1,711 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 108 voltage DODGE_BAT_CELL_108_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,712 to 1,727 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 109 voltage DODGE_BAT_CELL_109_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,728 to 1,743 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 110 voltage DODGE_BAT_CELL_110_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,744 to 1,759 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 111 voltage DODGE_BAT_CELL_111_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,760 to 1,775 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 112 voltage DODGE_BAT_CELL_112_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,776 to 1,791 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 113 voltage DODGE_BAT_CELL_113_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,792 to 1,807 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 114 voltage DODGE_BAT_CELL_114_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,808 to 1,823 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 115 voltage DODGE_BAT_CELL_115_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,824 to 1,839 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 116 voltage DODGE_BAT_CELL_116_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,840 to 1,855 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 117 voltage DODGE_BAT_CELL_117_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,856 to 1,871 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 118 voltage DODGE_BAT_CELL_118_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,872 to 1,887 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 119 voltage DODGE_BAT_CELL_119_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,888 to 1,903 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery cell 120 voltage DODGE_BAT_CELL_120_V
- Request
22 D4 40 - Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,904 to 1,919 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Battery coolant inlet temperature DODGE_BAT_COOLING_INLET_T
- Request
22 A0 21 - Service 22
DID A021 - Module
DA44 → 44 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery coolant outlet temperature DODGE_BAT_COOLING_OUTLET_T
- Request
22 A0 21 - Service 22
DID A021 - Module
DA44 → 44 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery current DODGE_BAT_CURRENT
- Request
22 D4 97 - Service 22
DID D497 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 1024)- Range
- -2097152 to 2097151 A
- Unit
- A
In testing for 2009 to 2020.
Battery DC current DODGE_BAT_DC_CURRENT
- Request
22 D8 16 - Service 22
DID D816 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 64 − 1200)- Range
- -1200 to 67107663 A
- Unit
- A
In testing for 2009 to 2020.
Battery heater inlet temperature DODGE_BAT_HEATER_INLET_T
- Request
22 40 53 - Service 22
DID 4053 - Module
DA42 → 42 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery heater outlet temperature DODGE_BAT_HEATER_OUTLET_T
- Request
22 40 53 - Service 22
DID 4053 - Module
DA42 → 42 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery heater, actual power consumption DODGE_BAT_HEATER_ACT_POWER
- Request
22 40 52 - Service 22
DID 4052 - Module
DA42 → 42 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700
- Unit
- Number
In testing for 2009 to 2020.
Battery heater, desired power consumption DODGE_BAT_HEATER_DES_POWER
- Request
22 40 52 - Service 22
DID 4052 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700
- Unit
- Number
In testing for 2009 to 2020.
Battery insulation resistance DODGE_BAT_INSULATION_RES
- Request
22 D4 7A - Service 22
DID D47A - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 kΩ
- Unit
- kΩ
In testing for 2009 to 2020.
Battery max unit temperature DODGE_BAT_MAX_UNIT_T
- Request
22 D8 17 - Service 22
DID D817 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery max unit temperature number DODGE_BAT_MAX_UNIT_T_NUMBER
- Request
22 D4 45 - Service 22
DID D445 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 2009 to 2020.
Battery min unit temperature DODGE_BAT_MIN_UNIT_T
- Request
22 D8 7D - Service 22
DID D87D - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery min unit temperature number DODGE_BAT_MIN_UNIT_T_NUMBER
- Request
22 D4 46 - Service 22
DID D446 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 2009 to 2020.
Battery module temperature sensor 1 DODGE_BAT_MODULE_T_SENS_1
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 2 DODGE_BAT_MODULE_T_SENS_2
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 3 DODGE_BAT_MODULE_T_SENS_3
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 4 DODGE_BAT_MODULE_T_SENS_4
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 5 DODGE_BAT_MODULE_T_SENS_5
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 6 DODGE_BAT_MODULE_T_SENS_6
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 7 DODGE_BAT_MODULE_T_SENS_7
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 8 DODGE_BAT_MODULE_T_SENS_8
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 9 DODGE_BAT_MODULE_T_SENS_9
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 10 DODGE_BAT_MODULE_T_SENS_10
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 11 DODGE_BAT_MODULE_T_SENS_11
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 12 DODGE_BAT_MODULE_T_SENS_12
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 13 DODGE_BAT_MODULE_T_SENS_13
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 14 DODGE_BAT_MODULE_T_SENS_14
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 15 DODGE_BAT_MODULE_T_SENS_15
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 16 DODGE_BAT_MODULE_T_SENS_16
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 17 DODGE_BAT_MODULE_T_SENS_17
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery module temperature sensor 18 DODGE_BAT_MODULE_T_SENS_18
- Request
22 A2 00 - Service 22
DID A200 - Module
DA44 → 44 - Every
5 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery pack link voltage DODGE_BAT_PACK_LINK_V
- Request
22 A0 11 - Service 22
DID A011 - Module
DA44 → 44 - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2009 to 2020.
Battery temperature DODGE_BAT_T
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2009 to 2020.
Battery temperature DODGE_BAT_T_V2
- Request
22 D8 EF - Service 22
DID D8EF - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery temperature 3 DODGE_BAT_T_3
- Request
22 A0 21 - Service 22
DID A021 - Module
DA44 → 44 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2009 to 2020.
Battery voltage DODGE_BAT_V
- Request
22 01 9E - Service 22
DID 019E - Module
DA42 → 42 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 43 ÷ 2500)- Range
- 0 to 1127 V
- Unit
- V
In testing for 2009 to 2020.
Battery voltage DODGE_BATT_V_ECU
- Request
22 19 55 - Service 22
DID 1955 - Module
DA10 → 10 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000)- Range
- 0 to 20 V
- Unit
- V
In testing for 2009 to 2020.
Battery voltage, BCM DODGE_BATT_V_BCM
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 04 - Service 22
DID 1004 - Module
DA40 → 40 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2009 to 2020.
Battery voltage, cell sum DODGE_BAT_V_CELL_SUM
Pelican can show this parameter as the traction battery voltage.
- Request
22 A0 11 - Service 22
DID A011 - Module
DA44 → 44 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2009 to 2020.
Battery voltage, module sum DODGE_BAT_V_MODULE_SUM
- Request
22 A0 11 - Service 22
DID A011 - Module
DA44 → 44 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2009 to 2020.
Cell voltage sum DODGE_CELL_V_SUMM
- Request
22 D4 38 - Service 22
DID D438 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 V
- Unit
- V
In testing for 2009 to 2020.
Centralized voltage maintenance device temperature limiter state DODGE_CENTRALIZED_V_T
- Request
22 D7 59 - Service 22
DID D759 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.
Charge air cooler outlet temperature DODGE_CHG_AIR_COOLER_T
- Request
21 B4 - Service 21
PID B4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 9 ÷ 320 + 32)- Range
- 0 to 1875 °F
- Unit
- °F
In testing for 2009 to 2020.
Charge air temperature DODGE_CHG_AIR_T
- Request
22 12 50 - Service 22
DID 1250 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 83)- Range
- -83 to 376 °F
- Unit
- °F
In testing for 2009 to 2020.
Charge pressure DODGE_CHG_P
- Request
21 B2 - Service 21
PID B2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 221)- Range
- 0 to 296 psi
- Unit
- psi
In testing for 2009 to 2020.
Charge temperature DODGE_CHG_T
- Request
21 B2 - Service 21
PID B2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 10 ÷ 711 + 32)- Range
- 0 to 953 °F
- Unit
- °F
In testing for 2009 to 2020.
Charged air cooler outlet temperature DODGE_CHARGED_AIR_COOLER_T
- Request
22 A0 EE - Service 22
DID A0EE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 36 ÷ 125 + 32)- Range
- 0 to 18906 °F
- Unit
- °F
In testing for 2009 to 2020.
Computer power supply voltage DODGE_COMPUTER_POWER_SUP_V
- Request
22 D5 51 - Service 22
DID D551 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2009 to 2020.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2016. Supported for 2009, 2014 to 2015, 2017.
Distance since last charge events 1 DODGE_DIST_SINCE_CHG_1
- Request
22 A0 70 - Service 22
DID A070 - Module
DA44 → 44 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 0.160935)- Range
- 0 to 10546 km
- Unit
- km
In testing for 2009 to 2020.
Distance since last charge events 2 DODGE_DIST_SINCE_CHG_2
- Request
22 A0 71 - Service 22
DID A071 - Module
DA44 → 44 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 0.160935)- Range
- 0 to 10546 km
- Unit
- km
In testing for 2009 to 2020.
Drive motor HV battery voltage DODGE_EMOTOR_HVBAT_V
- Request
22 30 62 - Service 22
DID 3062 - Module
DA42 → 42 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310 V
- Unit
- V
In testing for 2009 to 2020.
Drive motor HV input voltage DODGE_EMOTOR_HV_INPUT_V
- Request
22 B5 62 - Service 22
DID B562 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310 V
- Unit
- V
In testing for 2009 to 2020.
Electric A/C compressor HV input voltage DODGE_EAC_HV_V_INPUT
- Request
22 40 12 - Service 22
DID 4012 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 V
- Unit
- V
In testing for 2009 to 2020.
Energy accumulator discharge permission state DODGE_ENERGY_ACCUMULATOR
- Request
22 D7 4F - Service 22
DID D74F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.
Engine control computer supply voltage DODGE_ENG_CTRL_COMPUTER_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 D4 22 - Service 22
DID D422 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 V
- Unit
- V
In testing for 2009 to 2020.
Engine oil level sensor voltage DODGE_ENG_OIL_LEVEL_SENS_V
- Request
22 D4 1E - Service 22
DID D41E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2009 to 2020.
Evaluation of the total resistance of the voltage maintaining device DODGE_EVALUATION_TOT_RES_V
- Request
22 D7 2D - Service 22
DID D72D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128040.9703)- Range
- 0 to 0.511
- Unit
- Number
In testing for 2009 to 2020.
Glow plug unit supply voltage DODGE_PREHEATING_V
- Request
22 D5 0E - Service 22
DID D50E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 V
- Unit
- V
In testing for 2009 to 2020.
High voltage battery charge DODGE_HVBAT_SOC_RAW
Pelican can show this parameter as the state of charge.
- Request
22 D8 10 - Service 22
DID D810 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
High voltage battery charge (calibrated) DODGE_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Request
22 D4 10 - Service 22
DID D410 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2015, 2018 to 2020. Not supported for 2009, 2016 to 2017.
High voltage battery current from the battery pack control module DODGE_HVBAT_CURRENT_BPCM
- Request
22 03 01 - Service 22
DID 0301 - Module
DA42 → 42 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10 − 512.1)- Range
- -512 to 6041 A
- Unit
- A
In testing for 2009 to 2020.
High voltage battery health DODGE_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 D8 60 - Service 22
DID D860 - Module
6B4 → 694 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
High voltage battery voltage DODGE_HVBAT_VOLT
- Request
22 D8 15 - Service 22
DID D815 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 V
- Unit
- V
In testing for 2009 to 2020.
High voltage maximum voltage DODGE_HVBAT_MAX_VOLT
- Request
22 D8 70 - Service 22
DID D870 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
High voltage minimum voltage DODGE_HVBAT_MIN_VOLT
- Request
22 D8 6F - Service 22
DID D86F - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Highest battery temperature DODGE_MAX_CELL_T
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2009 to 2020.
Highest cell state of charge DODGE_MAX_CELL_ST_CHG
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Highest cell voltage DODGE_MAX_CELL_V
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Highest voltage cell number DODGE_HIGHEST_V_CELL
- Request
22 D4 3B - Service 22
DID D43B - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 2009 to 2020.
Highest voltage cell number DODGE_MAX_V_CELL_NUMBER
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.
HV battery current DODGE_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 A0 0A - Service 22
DID A00A - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20 − 1638.4)- Range
- -1638 to 1638 A
- Unit
- A
In testing for 2009 to 2020.
HV battery current capacity DODGE_HVBAT_CAP
- Request
22 A0 29 - Service 22
DID A029 - Module
DA44 → 44 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 Ah
- Unit
- Ah
In testing for 2009 to 2020.
HV battery energy DODGE_HVBAT_KWH
Energy stored in the high voltage battery
- Request
22 D8 65 - Service 22
DID D865 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 3276.75 kWh
- Unit
- kWh
In testing for 2009 to 2020.
HV battery lifetime amp-hours 1 DODGE_HVBAT_AH_1
- Request
22 A0 01 - Service 22
DID A001 - Module
DA44 → 44 - Every
30 s - Testing
Bits 24 to 47 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 Ah
- Unit
- Ah
In testing for 2009 to 2020.
HV battery lifetime amp-hours 2 DODGE_HVBAT_AH_2
- Request
22 A0 01 - Service 22
DID A001 - Module
DA44 → 44 - Every
30 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 Ah
- Unit
- Ah
In testing for 2009 to 2020.
HV battery lifetime energy 1 DODGE_HVBAT_KWH_1
- Request
22 A0 01 - Service 22
DID A001 - Module
DA44 → 44 - Every
30 s - Testing
Bits 72 to 95 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 kWh
- Unit
- kWh
In testing for 2009 to 2020.
HV battery lifetime energy 2 DODGE_HVBAT_KWH_2
- Request
22 A0 01 - Service 22
DID A001 - Module
DA44 → 44 - Every
30 s - Testing
Bits 96 to 119 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 kWh
- Unit
- kWh
In testing for 2009 to 2020.
HV battery nominal capacity DODGE_HVBAT_CAP_NOMINAL
- Request
22 A0 29 - Service 22
DID A029 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 Ah
- Unit
- Ah
In testing for 2009 to 2020.
HV battery state of charge DODGE_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
HV battery state of charge, estimate 1 DODGE_HVBAT_ST_CHG_EST_1
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
HV battery state of charge, estimate 3 DODGE_HVBAT_ST_CHG_EST_3
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
HV battery state of health DODGE_HVBAT_SOH_V2
Pelican can show this parameter as the state of health.
- Request
22 A0 29 - Service 22
DID A029 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 655.35)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
HV bus voltage DODGE_HV_BUS_V
- Request
22 40 52 - Service 22
DID 4052 - Module
DA42 → 42 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2009 to 2020.
Low temperature/charge air coolant pump speed DODGE_LOW_T_CHG_AIR_CLT
- Request
22 15 D4 - Service 22
DID 15D4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2009 to 2020.
Lowest battery temperature DODGE_MIN_CELL_T
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2009 to 2020.
Lowest cell state of charge DODGE_MIN_CELL_ST_CHG
- Request
22 A0 10 - Service 22
DID A010 - Module
DA44 → 44 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2009 to 2020.
Lowest cell voltage DODGE_MIN_CELL_V
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2009 to 2020.
Lowest voltage cell number DODGE_LOWEST_V_CELL_NUMBER
- Request
22 D4 3C - Service 22
DID D43C - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 2009 to 2020.
Lowest voltage cell number DODGE_MIN_V_CELL_NUMBER
- Request
22 A0 09 - Service 22
DID A009 - Module
DA44 → 44 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.
Maximum power the battery can provide for 10 seconds DODGE_MAX_POWER_BAT_CAN_PROVIDE_10
- Request
22 D8 73 - Service 22
DID D873 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 1953 ÷ 250000 − 500)- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2009 to 2020.
Maximum power the battery can provide for 30 seconds DODGE_MAX_POWER_BAT_CAN_PROVIDE_30
- Request
22 D8 74 - Service 22
DID D874 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 1953 ÷ 250000 − 500)- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2009 to 2020.
Maximum power the battery can withstand for 10 seconds DODGE_MAX_POWER_BAT_CAN_10
- Request
22 D8 71 - Service 22
DID D871 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 1953 ÷ 250000 − 500)- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2009 to 2020.
Maximum power the battery can withstand for 30 seconds DODGE_MAX_POWER_BAT_CAN_30
- Request
22 D8 72 - Service 22
DID D872 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 1953 ÷ 250000 − 500)- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2009 to 2020.
Minimum battery voltage at startup DODGE_MIN_BAT_V_STARTUP
- Request
22 D4 D4 - Service 22
DID D4D4 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50.00000112)- Range
- -655 to 655 V
- Unit
- V
In testing for 2009 to 2020.
On-board charger temperature DODGE_ON_BOARD_CHARGER_T
- Request
22 D8 E1 - Service 22
DID D8E1 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2009 to 2020.
Required fuel charge, cylinder 1 DODGE_REQUIRED_FUEL_CHG_1
- Request
22 02 B2 - Service 22
DID 02B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843
- Unit
- Raw value
In testing for 2009 to 2020.
Required fuel charge, cylinder 2 DODGE_REQUIRED_FUEL_CHG_2
- Request
22 02 B3 - Service 22
DID 02B3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843
- Unit
- Raw value
In testing for 2009 to 2020.
Required fuel charge, cylinder 3 DODGE_REQUIRED_FUEL_CHG_3
- Request
22 02 B4 - Service 22
DID 02B4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843
- Unit
- Raw value
In testing for 2009 to 2020.
Required fuel charge, cylinder 4 DODGE_REQUIRED_FUEL_CHG_4
- Request
22 02 B5 - Service 22
DID 02B5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843
- Unit
- Raw value
In testing for 2009 to 2020.
Reversible generator voltage DODGE_REVERSIBLE_GEN_V
- Request
22 D7 13 - Service 22
DID D713 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 V
- Unit
- V
In testing for 2009 to 2020.
Service battery charge state DODGE_SERVICE_BAT_CHG_ST
- Request
22 D7 42 - Service 22
DID D742 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.
Service battery charge status DODGE_SERVICE_BAT_CHG_STAT
- Request
22 D4 67 - Service 22
DID D467 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 %
- Unit
- %
In testing for 2009 to 2020.
Service battery temperature DODGE_SERVICE_BAT_T
- Request
22 D4 96 - Service 22
DID D496 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 °C
- Unit
- °C
In testing for 2009 to 2020.
Service battery temperature DODGE_SERVICE_BAT_T_6A8
- Request
22 D4 96 - Service 22
DID D496 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2009 to 2020.
Service battery voltage DODGE_SERVICE_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 D7 8A - Service 22
DID D78A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 V
- Unit
- V
In testing for 2009 to 2020.
Service battery wear condition DODGE_SERVICE_BAT_WEAR
- Request
22 D7 41 - Service 22
DID D741 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.
Service cell voltage value DODGE_SERVICE_CELL_V
- Request
22 D8 22 - Service 22
DID D822 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2009 to 2020.
Set voltage of energy storage DODGE_SET_V_ENERGY_STORAGE
- Request
22 D7 34 - Service 22
DID D734 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 32)- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2009 to 2020.
Set voltage of storage battery charging DODGE_SET_V_STORAGE_BAT
- Request
22 D7 66 - Service 22
DID D766 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 V
- Unit
- V
In testing for 2009 to 2020.
Set voltage of the reversible generator DODGE_SET_V_REVERSIBLE_GEN
- Request
22 D7 12 - Service 22
DID D712 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 39.9999994 + 10.60000038)- Range
- 0 to 16.97 V
- Unit
- V
In testing for 2009 to 2020.
Stop permitted by voltage maintainer computer DODGE_STOP_PERMITTED_V
- Request
22 D7 49 - Service 22
DID D749 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.
Temperature of the electronic power unit of the voltage maintenance device DODGE_T_ELECTRONIC_POWER_V
- Request
22 D7 30 - Service 22
DID D730 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2009 to 2020.
Turbocharger control duty cycle DODGE_TURBOCHARGER_CTRL
- Request
22 D4 8A - Service 22
DID D48A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 256)- Range
- -128 to 127 %
- Unit
- %
In testing for 2009 to 2020.
Turbocharger first electronic boost DODGE_TURBOCHARGER_FIRST
- Request
22 D4 8C - Service 22
DID D48C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.
Turbocharger position information DODGE_TURBOCHARGER_POS
- Request
22 D4 EA - Service 22
DID D4EA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100.0000022)- Range
- 0 to 655 %
- Unit
- %
In testing for 2009 to 2020.
Turbocharger pressure measured DODGE_TURBOCHARGER_P_MEAS
- Request
22 D4 D9 - Service 22
DID D4D9 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2009 to 2020.
Turbocharger pressure reference DODGE_TURBOCHARGER_P
- Request
22 D5 56 - Service 22
DID D556 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2009 to 2020.
Turbocharger speed DODGE_TURBOCHARGER_SPD
- Request
22 A0 E4 - Service 22
DID A0E4 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 125 ÷ 16)- Range
- 0 to 511992 rpm
- Unit
- rpm
In testing for 2009 to 2020.
Turbocharger, target position DODGE_TURBOCHARGER_TGT_POS
- Request
22 D4 7B - Service 22
DID D47B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 2009 to 2020.
Variable geometry turbo virtual charge flow DODGE_VGT_VIRTUAL_CHG_FLOW
- Request
21 DA - Service 21
PID DA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0035436904 + 32)- Range
- 0 to 264 kg/h
- Unit
- kg/h
In testing for 2009 to 2020.
Voltage at the terminals of the energy accumulator DODGE_V_TERMINALS_ENERGY
- Request
22 D7 20 - Service 22
DID D720 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 32)- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2009 to 2020.
Voltage maintainer computer request sent DODGE_V_MAINTAINER_COMPUTER_REQ
- Request
22 D7 48 - Service 22
DID D748 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.
Voltage maintainer computer restart permission DODGE_V_MAINTAINER
- Request
22 D7 47 - Service 22
DID D747 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.
Voltage maintainer status DODGE_V_MAINTAINER_STAT
- Request
22 D7 2C - Service 22
DID D72C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2009 to 2020.