Fuel parameters
The Chevrolet Volt has 28 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2016 to 2017. Supported for 2018.
Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2016 to 2017. Supported for 2018.
Ethanol content of fuel VOLT_ETHANOL_CONTENT_FUEL
- Request
22 00 52 - Service 22
DID 0052 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2011 to 2019, 2022.
Fuel consumption rate VOLT_FUEL_RATE
- Request
22 00 5E - Service 22
DID 005E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 500 ÷ 10000)- Range
- 0 to 3276.75 L
- Unit
- L
In testing for 2011 to 2019, 2022.
Fuel injection, cylinder 1 VOLT_FUEL_INJECTION_C1
- Request
22 20 AC - Service 22
DID 20AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10 ÷ 10000)- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2011 to 2019, 2022.
Fuel injection, cylinder 2 VOLT_FUEL_INJECTION_C2
- Request
22 11 94 - Service 22
DID 1194 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 65535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2011 to 2019, 2022.
Fuel injection, cylinder 3 VOLT_FUEL_INJECTION_C3
- Request
22 11 95 - Service 22
DID 1195 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 65535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2011 to 2019, 2022.
Fuel injection, cylinder 4 VOLT_FUEL_INJECTION_C4
- Request
22 11 96 - Service 22
DID 1196 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 65535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2011 to 2019, 2022.
Fuel injection, cylinder 5 VOLT_FUEL_INJECTION_C5
- Request
22 11 97 - Service 22
DID 1197 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 65535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2011 to 2019, 2022.
Fuel injection, cylinder 6 VOLT_FUEL_INJECTION_C6
- Request
22 11 98 - Service 22
DID 1198 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 65535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2011 to 2019, 2022.
Fuel injection, cylinder 8 VOLT_FUEL_INJECTION_C8
- Request
22 20 B3 - Service 22
DID 20B3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10 ÷ 10000)- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2011 to 2019, 2022.
Fuel Rail Pressure A FRP_ASAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2016 to 2017. Supported for 2018.
Fuel Rail Pressure B FRP_BSAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2016 to 2017. Supported for 2018.
Fuel Rail Temperature A FRT_ASAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2016 to 2017. Supported for 2018.
Fuel Rail Temperature B FRT_BSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2016 to 2017. Supported for 2018.
Fuel remaining VOLT_FLIConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 00 2F - Service 22
DID 002F - Module
7E0 → 7E8 - Every
30 s - Testing for 2011 to 2015, 2017 to 2019, 2022
Example reply from a 2016 Chevrolet Volt.
Bits 0 to 7 of the reply, 8 bits.
0x9D = 157 → (157 × 100 ÷ 255) = 61.568627 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016. In testing for 2011 to 2015, 2017 to 2019, 2022.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2016 to 2017. Supported for 2011 to 2014, 2018 to 2019.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2016 to 2017. Supported for 2011 to 2014, 2018 to 2019.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012, 2014, 2016 to 2018. Supported for 2011, 2013, 2019.
Fuel tank pressure VOLT_FUEL_TANK_P
- Request
22 F4 32 - Service 22
DID F432 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 33333.33333)- Range
- 0 to 1.96 psi
- Unit
- psi
In testing for 2011 to 2019, 2022.
Fuel temperature VOLT_FUEL_T
- Request
22 32 18 - Service 22
DID 3218 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 50 ÷ 100)- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2011 to 2019, 2022.
Total fuel consumption rate VOLT_TOTAL_FUEL_CONSUMPTION_RATE
- Request
22 00 9D - Service 22
DID 009D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 200 ÷ 10000)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
In testing for 2011 to 2019, 2022.
Fuel › Internal
Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2017. Supported for 2018.
Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2017. Supported for 2018.
Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2017. Supported for 2018.
Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2017. Supported for 2018.
Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2017. Supported for 2018.
Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016 to 2017. Supported for 2018.