Transmission parameters
The Cadillac CT5 has 7 transmission parameters.
● Confirmed◆ In testing○ Supported× Not supported
Current gear CT5_CURRENT_GEAR
- Request
22 19 9A - Service 22
DID 199A - Module
DA11 → 2AF111 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Current gear, variant 3 CT5_CURRENT_GEAR_VAR_3
- Request
22 32 01 - Service 22
DID 3201 - Module
DA11 → 2AF111 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Gear, AT position CT5_GEAR_POS
- Request
22 28 89 - Service 22
DID 2889 - Module
DA18 → 2AF118 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2020 to 2026.
Shift gear CT5_CURRENT_GEAR_2
- Request
22 1B 30 - Service 22
DID 1B30 - Module
DA18 → 2AF118 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | NEUTRAL | Neutral |
2 | PARK | Park |
3 | REVERSE | Reverse |
4 | D1 | Drive, gear 1 |
5 | D2 | Drive, gear 2 |
6 | D3 | Drive, gear 3 |
7 | D4 | Drive, gear 4 |
8 | D5 | Drive, gear 5 |
9 | D6 | Drive, gear 6 |
10 | D7 | Drive, gear 7 |
11 | D8 | Drive, gear 8 |
12 | D9 | Drive, gear 9 |
13 | D10 | Drive, gear 10 |
In testing for 2020 to 2026.
Transmission fluid temperature, filtered CT5_TF_T_FLTED
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 29 5A - Service 22
DID 295A - Module
DA18 → 2AF118 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Transmission fluid temperature, variant 1 CT5_TFT
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 19 40 - Service 22
DID 1940 - Module
DA18 → 2AF118 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Transmission pressure CT5_TRANS_P
- Request
22 28 62 - Service 22
DID 2862 - Module
DA18 → 2AF118 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 2020 to 2026.