BMW 7 Series

Climate parameters

The BMW 7 Series has 4 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Ambient air temperature 7SERIES_AATConfirmed

  • Request22 D1 12
  • Service 22DID D112
  • Module6F1 → 660
  • Every5 s
  • Testing for 1988 to 2010, 2013 to 2016, 2018 to 2019, 2021 to 2026

Example reply from a 2020 BMW 7 Series.

Bits 0 to 7 of the reply, 8 bits.

0x55 = 85 → (85 ÷ 2 − 40) = 2.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2011 to 2012, 2017, 2020. In testing for 1988 to 2010, 2013 to 2016, 2018 to 2019, 2021 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor operating state 7SERIES_COMP_STATE

  • Request22 D8 C5
  • Service 22DID D8C5
  • Module6F1 → 678
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2026.

Ambient air temperature 7SERIES_AATConfirmed

  • Request22 D1 12
  • Service 22DID D112
  • Module6F1 → 660
  • Every5 s
  • Testing for 1988 to 2010, 2013 to 2016, 2018 to 2019, 2021 to 2026

Example reply from a 2020 BMW 7 Series.

Bits 0 to 7 of the reply, 8 bits.

0x55 = 85 → (85 ÷ 2 − 40) = 2.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2011 to 2012, 2017, 2020. In testing for 1988 to 2010, 2013 to 2016, 2018 to 2019, 2021 to 2026.

Front air distribution, left 7SERIES_AIR_DIST_L

  • Request22 D9 1A
  • Service 22DID D91A
  • Module6F1 → 678
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2026.

Front air distribution, right 7SERIES_AIR_DIST_R

  • Request22 D9 1A
  • Service 22DID D91A
  • Module6F1 → 678
  • Every10 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.