BMW 1 Series

Climate parameters

The BMW 1 Series has 5 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor operating state 1SERIES_COMP_STATEConfirmed

  • Request22 D8 C5
  • Service 22DID D8C5
  • Module6F1 → 678
  • Every10 s
  • Testing for 2004 to 2018, 2020 to 2026

Example reply from a 2019 BMW 1 Series.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 2011 to 2018, 2020 to 2026. Not supported for 2008.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor operating state 1SERIES_COMP_STATEConfirmed

  • Request22 D8 C5
  • Service 22DID D8C5
  • Module6F1 → 678
  • Every10 s
  • Testing for 2004 to 2018, 2020 to 2026

Example reply from a 2019 BMW 1 Series.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 2011 to 2018, 2020 to 2026. Not supported for 2008.

Ambient air temperature 1SERIES_AATConfirmed

  • Request22 D1 12
  • Service 22DID D112
  • Module6F1 → 660
  • Every5 s
  • Testing for 2023 to 2026

Example reply from a 2022 BMW 1 Series.

Bits 0 to 7 of the reply, 8 bits.

0x4E = 78 → (78 ÷ 2 − 40) = -1 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2012 to 2022. In testing for 2023 to 2026. Not supported for 2007 to 2010.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2008, 2016 to 2019. Supported for 2013 to 2015, 2020 to 2021.

Front air distribution, left 1SERIES_AIR_DIST_LConfirmed

  • Request22 D9 1A
  • Service 22DID D91A
  • Module6F1 → 678
  • Every10 s
  • Testing for 2004 to 2018, 2020 to 2026

Example reply from a 2019 BMW 1 Series.

Bits 0 to 7 of the reply, 8 bits.

0x08 = 8 → 8

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 2011 to 2018, 2020 to 2026. Not supported for 2008.

Front air distribution, right 1SERIES_AIR_DIST_RConfirmed

  • Request22 D9 1A
  • Service 22DID D91A
  • Module6F1 → 678
  • Every10 s
  • Testing for 2004 to 2018, 2020 to 2026

Example reply from a 2019 BMW 1 Series.

Bits 8 to 15 of the reply, 8 bits.

0x08 = 8 → 8

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019. In testing for 2011 to 2018, 2020 to 2026. Not supported for 2008.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.