Bentley Bentayga

Climate parameters

The Bentley Bentayga has 46 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor load BENTLEY_HVAC_AC_LOAD

  • Request22 26 04
  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2015 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor load BENTLEY_HVAC_AC_LOAD

  • Request22 26 04
  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 N·m
Unit
N·m

In testing for 2015 to 2026.

A/C compressor power, actual BENTLEY_AC_CMPR_PWR_ACT

  • Request22 08 00
  • Service 22DID 0800
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 2015 to 2026.

A/c compressor torque, requested BENTLEY_AC_COMP_T

  • Request22 10 02
  • Service 22DID 1002
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2015 to 2026.

A/C refrigerant pressure, sensor 1 BENTLEY_AC_REFRIG_P_SENS1

  • Request22 4E EF
  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 88 ÷ 10000)
Range
0 to 576.708 bar
Unit
bar

In testing for 2015 to 2026.

A/C refrigerant temperature, sensor 1 BENTLEY_AC_REFRIG_T_SENS1

  • Request22 4E EF
  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 10 ÷ 100 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2015 to 2026.

A/C refrigerant temperature, sensor 1 interior BENTLEY_AC_REFRIG_T_SENS1_INT

  • Request22 4E EF
  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 10 ÷ 100 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2015 to 2026.

Air conditioning compressor power consumption BENTLEY_AC_COMP_PWR

  • Request22 27 D6
  • Service 22DID 27D6
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 25)
Range
0 to 10.2 kW
Unit
kW

In testing for 2015 to 2026.

Air conditioning compressor shutdown requirement BENTLEY_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENT

  • Request22 38 1A
  • Service 22DID 381A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Air conditioning compressor torque BENTLEY_PQ35_AC_COMP_TRQ

  • Request22 10 4B
  • Service 22DID 104B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2015 to 2026.

Air pollution level BENTLEY_AIR_POLUTION

0 means clean air.

  • Request22 26 ED
  • Service 22DID 26ED
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 10)
Range
-12.7 to 12.7
Unit
Number

In testing for 2015 to 2026.

Ambient air temperature BENTLEY_AAT

  • Request22 10 14
  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
0 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Ambient air temperature BENTLEY_AAT_V4

  • Request22 F4 46
  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2015 to 2026.

Barometric pressure BENTLEY_BARO

  • Request22 F4 33
  • Service 22DID F433
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2015 to 2026.

Cabin heater current BENTLEY_PTC_HEATER_I

  • Request22 16 04
  • Service 22DID 1604
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.937 A
Unit
A

In testing for 2015 to 2026.

CO2 content interior BENTLEY_CABIN_CO2

  • Request22 42 DB
  • Service 22DID 42DB
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100)
Range
0 to 25500
Unit
Number

In testing for 2015 to 2026.

Evaporator output temperature BENTLEY_HVAC_EVAP_T

  • Request22 26 12
  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2015 to 2026.

Front left temperature flap actual BENTLEY_FL_T_FLAP_ACT

  • Request22 26 22
  • Service 22DID 2622
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Front right temperature flap actual BENTLEY_FR_T_FLAP_ACT

  • Request22 26 26
  • Service 22DID 2626
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Inside humidity BENTLEY_HVAC_INSIDE_HUM

  • Request22 27 C4
  • Service 22DID 27C4
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Interior air temperature BENTLEY_IAT

  • Request22 26 13
  • Service 22DID 2613
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 255 °C
Unit
°C

In testing for 2015 to 2026.

Leg air vent temperature BENTLEY_LEG_DEFL_T

  • Request22 26 11
  • Service 22DID 2611
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.333)
Range
0 to 84.915 °C
Unit
°C

In testing for 2015 to 2026.

Outside humidity BENTLEY_HVAC_OUTSIDE_HUM

  • Request22 27 C3
  • Service 22DID 27C3
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Outside temperature BENTLEY_AAT_746

  • Request22 26 09
  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2015 to 2026.

Outside temperature BENTLEY_AAT_V2

  • Request22 26 09
  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 2)
Range
-64 to 63.5 °C
Unit
°C

In testing for 2015 to 2026.

Outside temperature BENTLEY_PTC_OUTSIDE_T

  • Request22 26 09
  • Service 22DID 2609
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 50)
Range
-50 to 77.5 °C
Unit
°C

In testing for 2015 to 2026.

Outside temperature BENTLEY_TRON_AAT

  • Request22 26 09
  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 100 °C
Unit
°C

In testing for 2015 to 2026.

Outside temperature, from cabin sensor BENTLEY_AAT_CABIN

  • Request22 26 0A
  • Service 22DID 260A
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 50)
Range
-50 to 77.5 °C
Unit
°C

In testing for 2015 to 2026.

Radiator fan actual value #1 BENTLEY_HVAC_FAN1_ACT

  • Request22 26 06
  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 %
Unit
%

In testing for 2015 to 2026.

Radiator fan actual value #2 BENTLEY_HVAC_FAN2_ACT

  • Request22 26 06
  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 %
Unit
%

In testing for 2015 to 2026.

Radiator fan commanded duty BENTLEY_PQ35_RAD_FAN_CMD

  • Request22 26 07
  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.4)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Radiator fan commanded value BENTLEY_HVAC_FAN_CMD

  • Request22 26 07
  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 %
Unit
%

In testing for 2015 to 2026.

Radiator fan duty BENTLEY_PQ35_RAD_FAN_DUTY

  • Request22 26 06
  • Service 22DID 2606
  • Module746 → 7B0
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.4)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Recirculation flap stop, fresh air BENTLEY_RECIRC_STOP_FRESH

  • Request22 26 20
  • Service 22DID 2620
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Recirculation flap stop, recirculated air BENTLEY_RECIRC_STOP_RECIRC

  • Request22 26 21
  • Service 22DID 2621
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Recirculation flap, actual BENTLEY_RECIRC_ACT_PCT

  • Request22 26 1E
  • Service 22DID 261E
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Recirculation flap, actual BENTLEY_RECIRC_FLAP_ACT_PCT

  • Request22 26 1E
  • Service 22DID 261E
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 0.5)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Recirculation flap, actual steps BENTLEY_RECIRC_ACT_STEPS

  • Request22 26 1E
  • Service 22DID 261E
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Recirculation flap, commanded steps BENTLEY_RECIRC_CMD_STEPS

  • Request22 26 1F
  • Service 22DID 261F
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2015 to 2026.

Refrigerant pressure BENTLEY_REFRIG_P

  • Request22 26 05
  • Service 22DID 2605
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.2)
Range
0 to 51 bar
Unit
bar

In testing for 2015 to 2026.

Temperature, front left deflector BENTLEY_FL_DEFL_T

  • Request22 26 0C
  • Service 22DID 260C
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.333)
Range
0 to 84.915 °C
Unit
°C

In testing for 2015 to 2026.

Temperature, front right deflector BENTLEY_FR_DEFL_T

  • Request22 26 0D
  • Service 22DID 260D
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.333)
Range
0 to 84.915 °C
Unit
°C

In testing for 2015 to 2026.

Temperature, rear deflector BENTLEY_REAR_DEFL_T

  • Request22 26 3D
  • Service 22DID 263D
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.333)
Range
0 to 84.915 °C
Unit
°C

In testing for 2015 to 2026.

Windshield temperature BENTLEY_WNDSHLD_TEMP

  • Request22 27 C4
  • Service 22DID 27C4
  • Module746 → 7B0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.576 − 38.8)
Range
-38.8 to 108.08 °C
Unit
°C

In testing for 2015 to 2026.

Climate › Heater

Heater current BENTLEY_PTC_HTR_I

  • Request22 47 5F
  • Service 22DID 475F
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.74 A
Unit
A

In testing for 2015 to 2026.

Heater fluid temperature #1 BENTLEY_PTC_HTR_FLUID_T1

  • Request22 47 5F
  • Service 22DID 475F
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Heater fluid temperature #2 BENTLEY_PTC_HTR_FLUID_T2

  • Request22 47 5F
  • Service 22DID 475F
  • Module742 → 7AC
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2015 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.