Aiways U5

Battery parameters

The Aiways U5 has 20 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

High voltage battery current U5_HVB_CConfirmed

Pelican can show this parameter as the traction battery current.

  • Request22 10 05
  • Service 22DID 1005
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 15 of the reply, 16 bits.

0x1B90 = 7056 → (7056 ÷ 10 − 700) = 5.6 A

Formula
(val ÷ 10 − 700)
Range
-500 to 500 A
Unit
A

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2021. Supported for 2022 to 2023.

High voltage battery current U5_HVB_CConfirmed

Pelican can show this parameter as the traction battery current.

  • Request22 10 05
  • Service 22DID 1005
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 15 of the reply, 16 bits.

0x1B90 = 7056 → (7056 ÷ 10 − 700) = 5.6 A

Formula
(val ÷ 10 − 700)
Range
-500 to 500 A
Unit
A

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

High voltage battery pack voltage U5_HVB_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Request22 10 04
  • Service 22DID 1004
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 15 of the reply, 16 bits.

0x0F05 = 3845 → (3845 ÷ 10) = 384.5 V

Formula
(val ÷ 10)
Range
0 to 500 V
Unit
V

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Request01 5B
  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Insulation resistance U5_ISO_RESConfirmed

  • Request22 10 20
  • Service 22DID 1020
  • Module703
  • Every60 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 15 of the reply, 16 bits.

0x1B58 = 7000 → 7,000 kΩ

Formula
val
Range
0 to 10000 kΩ
Unit
kΩ

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

State of charge, actual U5_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 10 07
  • Service 22DID 1007
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x4F = 79 → 79 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

State of charge, displayed U5_SOC_DISPConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 10 06
  • Service 22DID 1006
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x50 = 80 → 80 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

State of health U5_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Request22 10 12
  • Service 22DID 1012
  • Module703
  • Every3600 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x64 = 100 → 100 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

State of health, alternative U5_SOH_ALTConfirmed

Pelican can show this parameter as the state of health.

  • Request22 10 10
  • Service 22DID 1010
  • Module703
  • Every3600 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 15 of the reply, 16 bits.

0x0390 = 912 → (912 ÷ 10) = 91.2 %

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Water inlet temperature U5_WATER_IN_TConfirmed

  • Request22 10 1C
  • Service 22DID 101C
  • Module703
  • Every5 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x26 = 38 → (38 − 40) = -2 °C

Formula
(val − 40)
Range
-40 to 100 °C
Unit
°C

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Water outlet temperature U5_WATER_OUT_TConfirmed

  • Request22 10 1D
  • Service 22DID 101D
  • Module703
  • Every5 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x26 = 38 → (38 − 40) = -2 °C

Formula
(val − 40)
Range
-40 to 100 °C
Unit
°C

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Battery › Cells

Max cell voltage number U5_MAX_CELL_V_NUMConfirmed

  • Request22 10 31
  • Service 22DID 1031
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x3E = 62 → (62 + 1) = 63

Formula
(val + 1)
Range
0 to 96
Unit
Number

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Maximum cell cell state of charge id U5_HVB_MAX_CELL_IDConfirmed

  • Request22 12 02
  • Service 22DID 1202
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Maximum cell state of charge U5_HVBAT_CELL_SOC_MAXConfirmed

  • Request22 10 09
  • Service 22DID 1009
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x4F = 79 → 79 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Maximum cell temperature U5_HVB_MAX_CELL_TConfirmed

  • Request22 10 03
  • Service 22DID 1003
  • Module703
  • Every5 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x26 = 38 → (38 − 40) = -2 °C

Formula
(val − 40)
Range
-40 to 80 °C
Unit
°C

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Maximum cell voltage U5_HVB_MAX_CELL_VConfirmed

  • Request22 10 01
  • Service 22DID 1001
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Minimum cell cell state of charge id U5_HVB_MIN_CELL_IDConfirmed

  • Request22 12 02
  • Service 22DID 1202
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Minimum cell state of charge U5_HVBAT_CELL_SOC_MINConfirmed

  • Request22 10 08
  • Service 22DID 1008
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x4E = 78 → 78 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Minimum cell temperature U5_HVB_MIN_CELL_TConfirmed

  • Request22 10 02
  • Service 22DID 1002
  • Module703
  • Every5 s
  • Testing for 2019 to 2020, 2022

Example reply from a 2023 Aiways U5.

Bits 0 to 7 of the reply, 8 bits.

0x25 = 37 → (37 − 40) = -3 °C

Formula
(val − 40)
Range
-40 to 100 °C
Unit
°C

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Minimum cell voltage U5_HVB_MIN_CELL_VConfirmed

  • Request22 10 00
  • Service 22DID 1000
  • Module703
  • Every1 s
  • Testing for 2019 to 2020, 2022

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
0 to 5 V
Unit
V

Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.