Battery parameters
The Aiways U5 has 20 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2021. Supported for 2022 to 2023.
High voltage battery current U5_HVB_CConfirmed
Pelican can show this parameter as the traction battery current.
- Request
22 10 05 - Service 22
DID 1005 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 15 of the reply, 16 bits.
0x1B90 = 7056 → (7056 ÷ 10 − 700) = 5.6 A
- Formula
(val ÷ 10 − 700)- Range
- -500 to 500 A
- Unit
- A
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
High voltage battery pack voltage U5_HVB_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 10 04 - Service 22
DID 1004 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 15 of the reply, 16 bits.
0x0F05 = 3845 → (3845 ÷ 10) = 384.5 V
- Formula
(val ÷ 10)- Range
- 0 to 500 V
- Unit
- V
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Request
01 5B - Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021.
Insulation resistance U5_ISO_RESConfirmed
- Request
22 10 20 - Service 22
DID 1020 - Module
703 - Every
60 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 15 of the reply, 16 bits.
0x1B58 = 7000 → 7,000 kΩ
- Formula
val- Range
- 0 to 10000 kΩ
- Unit
- kΩ
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
State of charge, actual U5_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 10 07 - Service 22
DID 1007 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x4F = 79 → 79 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
State of charge, displayed U5_SOC_DISPConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 10 06 - Service 22
DID 1006 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x50 = 80 → 80 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
State of health U5_SOHConfirmed
Pelican can show this parameter as the state of health.
- Request
22 10 12 - Service 22
DID 1012 - Module
703 - Every
3600 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x64 = 100 → 100 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
State of health, alternative U5_SOH_ALTConfirmed
Pelican can show this parameter as the state of health.
- Request
22 10 10 - Service 22
DID 1010 - Module
703 - Every
3600 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 15 of the reply, 16 bits.
0x0390 = 912 → (912 ÷ 10) = 91.2 %
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Water inlet temperature U5_WATER_IN_TConfirmed
- Request
22 10 1C - Service 22
DID 101C - Module
703 - Every
5 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x26 = 38 → (38 − 40) = -2 °C
- Formula
(val − 40)- Range
- -40 to 100 °C
- Unit
- °C
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Water outlet temperature U5_WATER_OUT_TConfirmed
- Request
22 10 1D - Service 22
DID 101D - Module
703 - Every
5 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x26 = 38 → (38 − 40) = -2 °C
- Formula
(val − 40)- Range
- -40 to 100 °C
- Unit
- °C
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Battery › Cells
Max cell voltage number U5_MAX_CELL_V_NUMConfirmed
- Request
22 10 31 - Service 22
DID 1031 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x3E = 62 → (62 + 1) = 63
- Formula
(val + 1)- Range
- 0 to 96
- Unit
- Number
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Maximum cell cell state of charge id U5_HVB_MAX_CELL_IDConfirmed
- Request
22 12 02 - Service 22
DID 1202 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Maximum cell state of charge U5_HVBAT_CELL_SOC_MAXConfirmed
- Request
22 10 09 - Service 22
DID 1009 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x4F = 79 → 79 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Maximum cell temperature U5_HVB_MAX_CELL_TConfirmed
- Request
22 10 03 - Service 22
DID 1003 - Module
703 - Every
5 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x26 = 38 → (38 − 40) = -2 °C
- Formula
(val − 40)- Range
- -40 to 80 °C
- Unit
- °C
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Maximum cell voltage U5_HVB_MAX_CELL_VConfirmed
- Request
22 10 01 - Service 22
DID 1001 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Minimum cell cell state of charge id U5_HVB_MIN_CELL_IDConfirmed
- Request
22 12 02 - Service 22
DID 1202 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Minimum cell state of charge U5_HVBAT_CELL_SOC_MINConfirmed
- Request
22 10 08 - Service 22
DID 1008 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x4E = 78 → 78 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Minimum cell temperature U5_HVB_MIN_CELL_TConfirmed
- Request
22 10 02 - Service 22
DID 1002 - Module
703 - Every
5 s - Testing for 2019 to 2020, 2022
Example reply from a 2023 Aiways U5.
Bits 0 to 7 of the reply, 8 bits.
0x25 = 37 → (37 − 40) = -3 °C
- Formula
(val − 40)- Range
- -40 to 100 °C
- Unit
- °C
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.
Minimum cell voltage U5_HVB_MIN_CELL_VConfirmed
- Request
22 10 00 - Service 22
DID 1000 - Module
703 - Every
1 s - Testing for 2019 to 2020, 2022
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2021, 2023. In testing for 2019 to 2020, 2022.