Battery parameters
The Acura TSX has 202 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery coolant temperature ACURA_BATTERY_COOLANT_TEMPERATURE
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2014.
Battery module power ACURA_BATTERY_MODULE_POWER
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 168 to 183 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.016)- Range
- -524.288 to 524.272 kW
- Unit
- kW
In testing for 2004 to 2014.
Cell voltage limit during charge ACURA_CEL_V_LIM
- Request
22 20 29 - Service 22
DID 2029 - Module
DA15 → 15 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Charging voltage target ACURA_CHG_V_TGT
- Request
22 20 29 - Service 22
DID 2029 - Module
DA15 → 15 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2014. Supported for 2010, 2012.
Distance traveled since last charge ACURA_BAT_DIST
- Request
22 22 40 - Service 22
DID 2240 - Module
DA0E → 0E - Every
30 s - Testing
Bits 80 to 111 of the reply, 32 bits.
- Formula
val- Range
- 0 to 250000 km
- Unit
- km
In testing for 2004 to 2014.
High voltage battery cells, max state of charge ACURA_CELL_MAX_SOC
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2014.
High voltage battery cells, max state of charge ACURA_CELL_MIN_SOC
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2014.
High voltage battery module 1A temperature ACURA_HVB_MOD_1A_T
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2014.
High voltage battery module 1B temperature ACURA_HVB_MOD_1B_T
- Request
22 20 2C - Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2014.
High voltage battery module 2A temperature ACURA_HVB_MOD_2A_T
- Request
22 20 2C - Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 488 to 503 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2014.
High voltage battery module 3A temperature ACURA_HVB_MOD_3A_T
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2014.
High voltage battery module 3B temperature ACURA_HVB_MOD_3B_T
- Request
22 20 2C - Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2014.
High voltage battery module 4B temperature ACURA_HVB_MOD_4B_T
- Request
22 20 2C - Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 520 to 535 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2004 to 2014.
High voltage battery total capacity ACURA_HVB_CAP
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2004 to 2014.
High voltage battery total current ACURA_HVB_C_TOTAL
Pelican can show this parameter as the traction battery current.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -100 to 200 A
- Unit
- A
In testing for 2004 to 2014.
High voltage battery voltage ACURA_HVB_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 400 V
- Unit
- V
In testing for 2004 to 2014.
High voltage battery voltage, line B ACURA_HVB_V_B
Pelican can show this parameter as the starter battery voltage.
- Request
22 20 2A - Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 400 V
- Unit
- V
In testing for 2004 to 2014.
HV battery cell max state of charge ACURA_HV_BATTERY_CELL_MAX_STATE_OF_CHARGE
- Request
22 20 12 - Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2004 to 2014.
HV battery current ACURA_HV_BATTERY_CURRENT
- Request
22 20 10 - Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2004 to 2014.
HV battery fan 3 speed ACURA_HV_BATTERY_FAN_3_SPEED
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 288 to 295 of the reply, 8 bits.
- Formula
(val × 100)- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2004 to 2014.
HV battery max cell voltage ACURA_HV_BATTERY_MAX_CELL_VOLTAGE
- Request
22 22 22 - Service 22
DID 2222 - Module
DBEF - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2004 to 2014.
HV battery usable capacity ACURA_HV_BATTERY_USABLE_CAPACITY
- Request
22 20 12 - Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2014.
Motor assist battery temperature ACURA_IMA_BAT_T
- Request
22 26 14 - Service 22
DID 2614 - Module
DA11 → 11 - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 40)- Range
- -40 to 419 °C
- Unit
- °C
In testing for 2004 to 2014.
Motor assist battery temperature ACURA_IMA_BAT_T_DA10
- Request
22 26 14 - Service 22
DID 2614 - Module
DA10 → 10 - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 40)- Range
- -40 to 419 °C
- Unit
- °C
In testing for 2004 to 2014.
Normal charger input voltage ACURA_CHG_V_IN
- Request
22 20 21 - Service 22
DID 2021 - Module
DA15 → 15 - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 500 V
- Unit
- V
In testing for 2004 to 2014.
Normal charger output voltage ACURA_CHG_V_OUT
- Request
22 20 21 - Service 22
DID 2021 - Module
DA15 → 15 - Every
5 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 500 V
- Unit
- V
In testing for 2004 to 2014.
State of charge ACURA_SOC
Pelican can show this parameter as the state of charge.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2014.
State of charge ACURA_STATE_OF_CHARGE
- Request
22 20 12 - Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2014.
State of charge, raw count ACURA_ST_CHG_RAW_CNT
- Request
22 26 14 - Service 22
DID 2614 - Module
DA11 → 11 - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2004 to 2014.
State of charge, raw count ACURA_ST_CHG_RAW_CNT_DA10
- Request
22 26 14 - Service 22
DID 2614 - Module
DA10 → 10 - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2004 to 2014.
Battery › Cells
Battery capacity, line B ACURA_HVB_CAP_B
- Request
22 20 2A - Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2004 to 2014.
Cell voltage, 1 ACURA_CEL_V_B1
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 2 ACURA_CEL_V_B2
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 3 ACURA_CEL_V_B3
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 4 ACURA_CEL_V_B4
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 5 ACURA_CEL_V_B5
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 6 ACURA_CEL_V_B6
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 7 ACURA_CEL_V_B7
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 8 ACURA_CEL_V_B8
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 328 to 343 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 9 ACURA_CEL_V_B9
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 344 to 359 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 10 ACURA_CEL_V_B10
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 11 ACURA_CEL_V_B11
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 12 ACURA_CEL_V_B12
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 13 ACURA_CEL_V_B13
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 14 ACURA_CEL_V_B14
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 15 ACURA_CEL_V_B15
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 16 ACURA_CEL_V_B16
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 17 ACURA_CEL_V_B17
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 472 to 487 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 18 ACURA_CEL_V_B18
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 19 ACURA_CEL_V_B19
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 504 to 519 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 20 ACURA_CEL_V_B20
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 520 to 535 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 21 ACURA_CEL_V_B21
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 536 to 551 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 22 ACURA_CEL_V_B22
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 552 to 567 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 23 ACURA_CEL_V_B23
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 568 to 583 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 24 ACURA_CEL_V_B24
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 25 ACURA_CEL_V_B25
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 26 ACURA_CEL_V_B26
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 616 to 631 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 27 ACURA_CEL_V_B27
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 632 to 647 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 28 ACURA_CEL_V_B28
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 648 to 663 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 29 ACURA_CEL_V_B29
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 664 to 679 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 30 ACURA_CEL_V_B30
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 680 to 695 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 31 ACURA_CEL_V_B31
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 696 to 711 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 32 ACURA_CEL_V_B32
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 712 to 727 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 33 ACURA_CEL_V_B33
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 728 to 743 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 34 ACURA_CEL_V_B34
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 744 to 759 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 35 ACURA_CEL_V_B35
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 760 to 775 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 36 ACURA_CEL_V_B36
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 776 to 791 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 37 ACURA_CEL_V_B37
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 792 to 807 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 38 ACURA_CEL_V_B38
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 808 to 823 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 39 ACURA_CEL_V_B39
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 824 to 839 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 40 ACURA_CEL_V_B40
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 840 to 855 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 41 ACURA_CEL_V_B41
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 856 to 871 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 42 ACURA_CEL_V_B42
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 872 to 887 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 43 ACURA_CEL_V_B43
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 888 to 903 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 44 ACURA_CEL_V_B44
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 904 to 919 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 45 ACURA_CEL_V_B45
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 920 to 935 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 46 ACURA_CEL_V_B46
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 936 to 951 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 47 ACURA_CEL_V_B47
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 952 to 967 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 48 ACURA_CEL_V_B48
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 968 to 983 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 49 ACURA_CEL_V_B49
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 984 to 999 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 50 ACURA_CEL_V_B50
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 51 ACURA_CEL_V_B51
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 52 ACURA_CEL_V_B52
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 53 ACURA_CEL_V_B53
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 54 ACURA_CEL_V_B54
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 55 ACURA_CEL_V_B55
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 56 ACURA_CEL_V_B56
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 57 ACURA_CEL_V_B57
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 58 ACURA_CEL_V_B58
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 59 ACURA_CEL_V_B59
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 60 ACURA_CEL_V_B60
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 61 ACURA_CEL_V_B61
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 62 ACURA_CEL_V_B62
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 63 ACURA_CEL_V_B63
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 64 ACURA_CEL_V_B64
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 65 ACURA_CEL_V_B65
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 66 ACURA_CEL_V_B66
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 67 ACURA_CEL_V_B67
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 68 ACURA_CEL_V_B68
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 69 ACURA_CEL_V_B69
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 70 ACURA_CEL_V_B70
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 71 ACURA_CEL_V_B71
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 72 ACURA_CEL_V_B72
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 73 ACURA_CEL_V_B73
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,368 to 1,383 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 74 ACURA_CEL_V_B74
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,384 to 1,399 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 75 ACURA_CEL_V_B75
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,400 to 1,415 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 76 ACURA_CEL_V_B76
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,416 to 1,431 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 77 ACURA_CEL_V_B77
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,432 to 1,447 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 78 ACURA_CEL_V_B78
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,448 to 1,463 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 79 ACURA_CEL_V_B79
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,464 to 1,479 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 80 ACURA_CEL_V_B80
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,480 to 1,495 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 81 ACURA_CEL_V_B81
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,496 to 1,511 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 82 ACURA_CEL_V_B82
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,512 to 1,527 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 83 ACURA_CEL_V_B83
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,528 to 1,543 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Cell voltage, 84 ACURA_CEL_V_B84
- Request
22 20 28 - Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,544 to 1,559 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell max SOC, line B ACURA_CEL_MAX_SOC_B
- Request
22 20 2A - Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2014.
Individual cell min SOC, line B ACURA_CEL_MIN_SOC_B
- Request
22 20 2A - Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2014.
Individual cell voltage A1 ACURA_CEL_V_A1
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A2 ACURA_CEL_V_A2
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A3 ACURA_CEL_V_A3
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A4 ACURA_CEL_V_A4
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A5 ACURA_CEL_V_A5
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A6 ACURA_CEL_V_A6
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A7 ACURA_CEL_V_A7
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A8 ACURA_CEL_V_A8
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 328 to 343 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A9 ACURA_CEL_V_A9
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 344 to 359 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A10 ACURA_CEL_V_A10
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A11 ACURA_CEL_V_A11
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A12 ACURA_CEL_V_A12
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A13 ACURA_CEL_V_A13
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A14 ACURA_CEL_V_A14
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A15 ACURA_CEL_V_A15
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A16 ACURA_CEL_V_A16
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A17 ACURA_CEL_V_A17
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 472 to 487 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A18 ACURA_CEL_V_A18
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A19 ACURA_CEL_V_A19
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 504 to 519 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A20 ACURA_CEL_V_A20
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 520 to 535 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A21 ACURA_CEL_V_A21
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 536 to 551 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A22 ACURA_CEL_V_A22
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 552 to 567 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A23 ACURA_CEL_V_A23
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 568 to 583 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A24 ACURA_CEL_V_A24
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A25 ACURA_CEL_V_A25
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A26 ACURA_CEL_V_A26
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 616 to 631 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A27 ACURA_CEL_V_A27
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 632 to 647 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A28 ACURA_CEL_V_A28
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 648 to 663 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A29 ACURA_CEL_V_A29
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 664 to 679 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A30 ACURA_CEL_V_A30
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 680 to 695 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A31 ACURA_CEL_V_A31
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 696 to 711 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A32 ACURA_CEL_V_A32
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 712 to 727 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A33 ACURA_CEL_V_A33
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 728 to 743 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A34 ACURA_CEL_V_A34
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 744 to 759 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A35 ACURA_CEL_V_A35
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 760 to 775 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A36 ACURA_CEL_V_A36
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 776 to 791 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A37 ACURA_CEL_V_A37
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 792 to 807 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A38 ACURA_CEL_V_A38
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 808 to 823 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A39 ACURA_CEL_V_A39
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 824 to 839 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A40 ACURA_CEL_V_A40
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 840 to 855 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A41 ACURA_CEL_V_A41
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 856 to 871 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A42 ACURA_CEL_V_A42
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 872 to 887 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A43 ACURA_CEL_V_A43
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 888 to 903 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A44 ACURA_CEL_V_A44
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 904 to 919 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A45 ACURA_CEL_V_A45
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 920 to 935 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A46 ACURA_CEL_V_A46
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 936 to 951 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A47 ACURA_CEL_V_A47
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 952 to 967 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A48 ACURA_CEL_V_A48
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 968 to 983 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A49 ACURA_CEL_V_A49
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 984 to 999 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A50 ACURA_CEL_V_A50
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A51 ACURA_CEL_V_A51
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A52 ACURA_CEL_V_A52
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A53 ACURA_CEL_V_A53
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A54 ACURA_CEL_V_A54
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A55 ACURA_CEL_V_A55
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A56 ACURA_CEL_V_A56
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A57 ACURA_CEL_V_A57
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A58 ACURA_CEL_V_A58
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A59 ACURA_CEL_V_A59
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A60 ACURA_CEL_V_A60
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A61 ACURA_CEL_V_A61
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A62 ACURA_CEL_V_A62
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A63 ACURA_CEL_V_A63
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A64 ACURA_CEL_V_A64
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A65 ACURA_CEL_V_A65
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A66 ACURA_CEL_V_A66
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A67 ACURA_CEL_V_A67
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A68 ACURA_CEL_V_A68
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A69 ACURA_CEL_V_A69
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A70 ACURA_CEL_V_A70
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A71 ACURA_CEL_V_A71
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A72 ACURA_CEL_V_A72
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A73 ACURA_CEL_V_A73
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,368 to 1,383 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A74 ACURA_CEL_V_A74
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,384 to 1,399 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A75 ACURA_CEL_V_A75
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,400 to 1,415 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A76 ACURA_CEL_V_A76
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,416 to 1,431 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A77 ACURA_CEL_V_A77
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,432 to 1,447 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A78 ACURA_CEL_V_A78
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,448 to 1,463 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A79 ACURA_CEL_V_A79
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,464 to 1,479 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A80 ACURA_CEL_V_A80
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,480 to 1,495 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A81 ACURA_CEL_V_A81
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,496 to 1,511 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A82 ACURA_CEL_V_A82
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,512 to 1,527 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A83 ACURA_CEL_V_A83
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,528 to 1,543 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.
Individual cell voltage A84 ACURA_CEL_V_A84
- Request
22 20 28 - Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,544 to 1,559 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2004 to 2014.