Acura TLX

Fuel parameters

The Acura TLX has 24 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine exhaust flow rate EXH_RATEConfirmed

  • Request01 9E
  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Request01 9E
  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2021.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2021.

Fuel level TLX_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 70 29
  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every30 s
  • Testing for 2016 to 2024

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 L
Unit
L

Confirmed for 2015, 2025. In testing for 2016 to 2024.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2015, 2021. Supported for 2018, 2020, 2022, 2024 to 2025.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2015, 2021. Supported for 2018, 2020, 2022, 2024 to 2025.

Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 63 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 71 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2015, 2020 to 2021, 2025. Supported for 2018, 2022, 2024.

Fuel/air commanded equivalence ratio TLX_FUEL_AIR_RATIOConfirmed

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 2016 to 2019, 2022 to 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2015, 2020 to 2021, 2025. In testing for 2016 to 2019, 2022 to 2024.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2021.

Fuel › Internal

Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.