Acura MDX

Transmission parameters

The Acura MDX has 6 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Current gear var.2 ACURA_CURRENT_GEAR_VAR_2

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every250 ms
  • Testing

Bits 352 to 359 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2020, 2022 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Current gear var.2 ACURA_CURRENT_GEAR_VAR_2

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every250 ms
  • Testing

Bits 352 to 359 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2020, 2022 to 2026.

Current gear var.3 ACURA_CURRENT_GEAR_VAR_3

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every250 ms
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2020, 2022 to 2026.

Gear ACURA_GEAR_V2

  • Request22 22 21
  • Service 22DID 2221
  • ModuleDA1D → 1D
  • Every250 ms
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2002, 2004 to 2012, 2014 to 2015, 2019 to 2020, 2023. Not supported for 2003, 2013, 2016 to 2018, 2022, 2024 to 2026.

Transmission fluid temperature ACURA_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 22 01
  • Service 22DID 2201
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2016, 2018. In testing for 2001 to 2002, 2004 to 2012, 2015, 2019 to 2020, 2023. Not supported for 2003, 2013 to 2014, 2017, 2022, 2024 to 2026.

Transmission fluid temperature ACURA_ATF_T_V2

  • Request22 30 83
  • Service 22DID 3083
  • ModuleDA1E → 1E
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 200 °C
Unit
°C

In testing for 2001 to 2020, 2022 to 2026.

Transmission gear ACURA_GEARConfirmed

  • Request22 30 86
  • Service 22DID 3086
  • ModuleDA1E → 1E
  • Every250 ms
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0PPark
1D1Drive 1
2D2Drive 2
3D3Drive 3
4D4Drive 4
5D5Drive 5
6D6Drive 6
7D7Drive 7
8D8Drive 8
9D9Drive 9
14NNeutral
15RReverse

Confirmed for 2016, 2018. In testing for 2001 to 2002, 2004 to 2012, 2015, 2019 to 2020, 2023. Not supported for 2003, 2013 to 2014, 2017, 2022, 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.